Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

FAST (FAST AUTONOMOUS SCANNING TOOLKIT)

SF-23-006 FAST (FAST AUTONOMOUS SCANNING TOOLKIT)The software is deployed on an edge computing device at the beamline computer attached to a scanning microscope. It iteratively analyzes the data collected, then identifies new scan positions to scan next and directs the positioners that move the sample (or probe beam) to these positions. Overall, it identifies a sparse set of scan positions that are sufficient to image the full sample. This can reduce the scan time by >60%.

KANDEL, SAUGAT↗

Bias-dependent interface roughening and its effect on electric bistability of organic devices

Atomic force microscopy (AFM), field-emission scanning electron microscopy, and energy dispersive X-Ray spectroscopy are used to study morphological and compositional variations of metal-organic interfaces in organic bistable devices. The results show that bias voltage causes rougher interfaces with new protrusions, and the switching phenomena origins from the evolution of these protrusions under external electric field. In order to exclude other possible factors, three types of bistable devices are designed and examined. In addition, metal-coated AFM probes are utilized to simulate the switching process, which yields similar results and corroborates our conclusion.

36 MATERIALS SCIENCE↗

Sci—Thur AM: YIS - 10: Use of the Microsoft Kinect for applications of patient surface data to radiotherapy

Current techniques to acquire patient surface data are often very expensive and lack flexibility. In this study, the use of the Microsoft Kinect to reliably acquire 3D scans of patient surface is investigated. A design is presented to make the system easily applicable to the clinic. Potential applications of the device to radiotherapy are also presented. Scan reproducibility was tested by repeatedly scanning an anthropomorphic phantom. Scan accuracy was tested by comparing Kinect scans to the surface extracted from a CT dataset of a Rando® anthropomorphic phantom, which was considered as the true reference surface. Average signed distances of 0.12 ± 2.34 mm and 0.13 ± 2.04 mm were obtained between the compared surfaces for reproducibility and accuracy respectively. This is conclusive, since it indicates that the variations observed come largely from noise distributed around an average distance close to 0 mm. Moreover, the range of the noise is small enough for the system to reliably capture a patient's surface. A system was also designed using two Kinects used together to acquire 3D surfaces in a quick and stable way that is applicable to the clinic. Finally, applications of the device to radiotherapy are demonstrated. Its use to detect local positioning errors is presented, where small local variations difficult to see with the naked eye are clearly visible. The system was also used to predict collisions using gantry and patient scans and thus ensure the safety of unconventional trajectories.

60 APPLIED LIFE SCIENCES↗

Spectroscopic refractometer for transparent and absorbing liquids by reflection of white light near the critical angle

We propose and evaluate a spectroscopic refractometer device to measure the refractive index dispersion of transparent and absorbing solutions. The angle-dependent reflectivity of a white beam of light in an internal reflection configuration around the critical angle is spectrally analyzed. The refractive index in a wavelength range from 400 nm to 900 nm is obtained from the angle-reflectivity curve around the critical angle at each wavelength. The device does not use angle scanning mechanisms, decreasing considerably the complexity of the instrument in comparison to previous proposals. As a result, the measurements are obtained relatively fast. Nevertheless, a good experimental resolution in refractive index of about {Delta}n Almost-Equal-To 10{sup -4} at all the wavelengths is achieved in the case of transparent solutions. The calibration procedure of the device is discussed in detail. We also present measurements of the refractive index dispersion of rhodamine 6G-methanol solutions, which has a strong absorption band in the visible spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotic automation of droplet microfluidics

Droplet microfluidics enables powerful analytic capabilities but often requires workflows involving macro- and microfluidic processing steps that are cumbersome to perform manually. Here, we demonstrate the automation of droplet microfluidics with commercial fluid-handling robotics. The workflows incorporate common microfluidic devices including droplet generators, mergers, and sorters and utilize the robot's native capabilities for thermal control, incubation, and plate scanning. The ability to automate microfluidic devices using commercial fluid handling will speed up the integration of these methods into biological workflows.

59 BASIC BIOLOGICAL SCIENCES↗

Photothermal alternative to device fabrication using atomic precision advanced manufacturing techniques

The attachment of dopant precursor molecules to depassivated areas of hydrogen-terminated silicon templated with a scanning tunneling microscope (STM) has been used to create electronic devices with subnanometer precision, typically for quantum physics experiments. This process, which we call atomic precision advanced manufacturing (APAM), dopes silicon beyond the solid-solubility limit and produces electrical and optical characteristics that may also be useful for microelectronic and plasmonic applications. However, scanned probe lithography lacks the throughput required to develop more sophisticated applications. In this work, we demonstrate and characterize an APAM device workflow where scanned probe lithography of the atomic layer resist has been replaced by photolithography. An ultraviolet laser is shown to locally and controllably heat silicon above the temperature required for hydrogen depassivation on a nanosecond timescale, a process resistant to under- and overexposure. STM images indicate a narrow range of energy density where the surface is both depassivated and undamaged. Modeling that accounts for photothermal heating and the subsequent hydrogen desorption kinetics suggests that the silicon surface temperatures reached in our patterning process exceed those required for hydrogen removal in temperature-programmed desorption experiments. A phosphorus-doped van der Pauw structure made by sequentially photodepassivating a predefined area and then exposing it to phosphine is found to have a similar mobility and higher carrier density compared with devices patterned by STM. Lastly, it is also demonstrated that photodepassivation and precursor exposure steps may be performed concomitantly, a potential route to enabling APAM outside of ultrahigh vacuum.

nanoscale devices↗

Atomic-scale control of tunneling in donor-based devices

Atomically precise donor-based quantum devices are a promising candidate for solid-state quantum computing and analog quantum simulations. However, critical challenges in atomically precise fabrication have meant systematic, atomic scale control of the tunneling rates and tunnel coupling has not been demonstrated. Here using a room temperature grown locking layer and precise control over the entire fabrication process, we reduce unintentional dopant movement while achieving high quality epitaxy in scanning tunnelling microscope (STM)-patterned devices. Using the Si(100)2 × 1 surface reconstruction as an atomically-precise ruler to characterize the tunnel gap in precision-patterned single electron transistors, we demonstrate the exponential scaling of the tunneling resistance on the tunnel gap as it is varied from 7 dimer rows to 16 dimer rows. We demonstrate the capability to reproducibly pattern devices with atomic precision and a donor-based fabrication process where atomic scale changes in the patterned tunnel gap result in the expected changes in the tunneling rates.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ni-doped α-Fe 2 O 3 as electron transporting material for planar heterojunction perovskite solar cells with improved efficiency, reduced hysteresis and ultraviolet stability

We report on high-efficiency planar heterojunction perovskite solar cells (PSCs) employing Ni-doped alpha-Fe2O3 as electron-transporting layer (ETL). The suitable addition of nickel (Ni) dopant could enhance the electron conductivity as well as induce downward shift of the conduction band minimum for alpha-Fe2O3, which facilitate electrons injection and transfer from the conduction band of the perovskite. As a consequence, a substantial reduction in the charge accumulation at the perovskite/ETL interface makes the device much less sensitive to scanning rate and direction, i.e., lower hysteresis. With a reverse scan for the optimized PSC under standard AM-1.5 sunlight illumination, it generates a competitive power conversion efficiency (PCE) of 14.2% with a large short circuit current (J(sc)) of 22.35 mA/cm(2), an open circuit photovoltage (V-oc) of 0.92 V and a fill factor (FF) of 69.1%. Due to the small J-V hysteresis behavior, a higher stabilized PCE up to 11.6% near the maximum power point can be reached for the device fabricated with 4 mol% Ni-doped alpha-Fe2O3 ETL compared with the undoped alpha-Fe2O3 based cell (9.2%). Furthermore, a good stability of devices with exposure to ambient air and high levels of ultraviolet (UV)-light can be achieved. Overall, our results demonstrate that the simple solution-processed Ni-doped alpha-Fe2O3 can be a good candidate of the n-type collection layer for commercialization of PSCs.

14 SOLAR ENERGY↗

SU-E-I-78: Improving Prostatic Delineation Using Dual-Energy CT

Purpose: Visual prostatic definition is difficult using conventional CT. This is because the prostate is surrounded closely with tissue of similar electron density. Definition is further hindered when the region contains high-Z material (such as fiducial markers). Dual-energy CT (DECT) is a technique where images are rendered using two tube voltages during a single scan session. This study evaluates DECT as a means of improving prostatic volume delineation for radiation oncology. Methods: The patients were scanned using a Definition AS20 (Siemens Healthcare, Malvern, PA). This device uses a single-tube configuration, where two scans of differing energies are performed in serial. The scans are acquired with tube voltage of 80kVp and 140kVp. Following acquisition, these scan data were used to generate effective monoenergetic scans ranging from 40keV to 190keV. In the current study, the data were presented to observers using a novel program, which allows real-time adjustment of window, level, and effective keV; all while scrolling through volumetric slices. Three patients were scanned, each with a different high-contrast material in or around the prostate: I-125 seeds, gold fiducial markers, and prostatic calcifications. These images are compared to a weighted average of the 80kVp and 140kVP scans, which yield a scan similar to that of a 120 kVp scan, which is a common tube voltage in radiation oncology. Results: Prostatic definition improved in each case. Differentiation of soft tissue from surrounding adipose improved with lower keV, while higher keV provided a reduction of high-z artifacts. Furthermore, the dynamic adjustment of the keV allowed observers to better recognize regions of differing tissue composition within this relatively homogeneous area. Conclusion: By simultaneously providing the observer with the benefits of high-energy images and low-energy images, and allowing adjustment in real-time, improved imaging in highly homogeneous regions such as the male pelvis is achievable.

60 APPLIED LIFE SCIENCES↗

Python STXM Control (pystxmcontrol) v0.1

The software is a complete solution for controlling scanning microscopes. It provides a low level interface to device hardware via drivers, communication and coordination layers for managing scan execution and data acquisition, a graphical interface and scripting interface for user interaction. With optimized hardware drivers and low software overhead this software is 10 times faster than the legacy software it is replacing.

Shapiro, David [Lawrence Berkeley National Laborat↗

Spatially-resolved mapping of history-dependent coupled electrochemical and electronical behaviors of electroresistive NiO

Bias-induced oxygen ion dynamics underpins a broad spectrum of electroresistive and memristive phenomena in oxide materials. Although widely studied by device-level and local voltage-current spectroscopies, the relationship between electroresistive phenomena, local electrochemical behaviors, and microstructures remains elusive. Here, the interplay between history-dependent electronic transport and electrochemical phenomena in a NiO single crystalline thin film with a number of well-defined defect types is explored on the nanometer scale using an atomic force microscopy-based technique. A variety of electrochemically-active regions were observed and spatially resolved relationship between the electronic and electrochemical phenomena was revealed. The regions with pronounced electroresistive activity were further correlated with defects identified by scanning transmission electron microscopy. Using fully coupled mechanical-electrochemical modeling, we illustrate that the spatial distribution of strain plays an important role in electrochemical and electroresistive phenomena. In conclusion, these studies illustrate an approach for simultaneous mapping of the electronic and ionic transport on a single defective structure level such as dislocations or interfaces, and pave the way for creating libraries of defect-specific electrochemical responses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crystallinity dependence of resistive switching in Ti/Pr(Sr{sub 0.1}Ca{sub 0.9}){sub 2}Mn{sub 2}O{sub 7}/Pt: Filamentary versus interfacial mechanisms

The resistive switching characteristics of two Pr(Sr{sub 0.1}Ca{sub 0.9}){sub 2}Mn{sub 2}O{sub 7} (PSCMO)-based devices (Ti/PSCMO-1/Pt and Ti/PSCMO-2/Pt) prepared under different conditions have been investigated. The two devices both showed bipolar switching behaviors. Scanning electron microscope measurements showed different grain boundaries in the two PSCMO films. By fitting the I-V curves and area dependence of the device resistance, we found that the Ti/PSCMO-1/Pt device indicated filamentary conduction, whereas interfacial effects dominated the conductance in Ti/PSCMO-2/Pt device. Our results suggest that the different grain boundaries may play a critical role in oxygen vacancy movement and hence result in the two different resistive switching properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gallium nitride nanoneedles grown in extremely non-equilibrium nitrogen plasma

In the present work, gallium nitride (GaN) nanoneedles are grown on quartz substrates using the high fluence ions of GaN produced by hot, dense and extremely non-equlibrium nitrogen plasma in a modified dense plasma focus device. The formation of nanoneedles is obtained from the scanning electron microscopy with mean size of the head of nanoneedles ~ 70 nm. The nanoneedles are found to be poly-crystalline when studied structurally through the X-ray diffraction. The optical properties of nanoneedles studied using absorption spectra which show more absorption for nanoneedles depsoited one shot of ions irradiation. In addition, the band gap of nanoneedles is found to be increased as compared to bulk GaN. The obtained nanoneedles with increased band gap have potential applications in detector systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy

Purpose: Measurement of actual dose delivered during radiotherapy treatment aids in checking the accuracy of dose delivered to the patient. In this study, a couch-based real time dosimetric device has been proposed to measure the exit or entrance dose to a patient during external beam radiotherapy. The utility and feasibility of such a device using a 2D array of diodes has been demonstrated. Methods: Two MAPCHECK devices: MAPCHECK (1175) and MAPCHECK 2 (both SunNuclear) were embedded in a foam block in the treatment couch of a Varian 21iX linear accelerator. The angular dependence of the detector response for both devices was studied before implementing the MAPCHECKs for experimental purposes. An Alderson Rando head phantom was scanned with the MAPCHECK and MAPCHECK 2 devices separately and four different treatment plans were generated with target volumes at three different positions simulating typical clinical situations. The analytical anisotropic algorithm (AAA) was used to compute the doses in an Eclipse treatment planning system (Varian Medical Systems). The Rando phantom with the MAPCHECK device was exposed in Clinac 21iX linear accelerator. The measured dose distribution was compared with the calculated dose distribution to check for the accuracy in dose delivery. Results: Measured and computed dose distribution were found to agree with more than 93% of pixels passing at 3% and 3 mm gamma criteria for all the treatment plans. The couch-based real time dosimetry system may also be applied for noncoplanar beams where electronic portal imaging device (EPID) is not practical to measure the dose. Other advantages include checking the beam stability during the patient treatment, performing routine morning quality assurance (QA) tests in the linear accelerator, and to perform pretreatment verification of intensity modulated radiation therapy (IMRT). One of the drawbacks of this system is that it cannot be used for measuring the dose at 90 deg. or 270 deg. gantry angles. Conclusions: This preliminary study shows that a 2D array of detectors may be used as part of the treatment couch for real time patient dosimetry in studying the dose delivered to the patient in real time and also for performing routine quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cryogenic near-field thermal diode leveraging superconducting phase transitions

Control of charge and heat transport is essential for computing and thermal management technologies. Recent work with superconducting materials has shown rectified electrical supercurrents near liquid helium temperatures. However, despite large theoretical interest and expected impact on quantum technologies, no experiments have demonstrated control of nanoscale radiative heat currents at cryogenic temperatures. Here we study photon-mediated thermal transport in nanogaps between niobium and gold. Using novel scanning calorimetric probes and nanofabricated devices, we reveal a ~20-fold suppression of radiative heat transport, when niobium transitions from the metallic to the superconducting state. Taking advantage of this effect, we also demonstrate a niobium-based cryogenic thermal diode with a heat rectification ratio of 70%. As a result, the experimental techniques and advances presented here will enable studying nanoscale thermal transport in quantum materials and advancing thermal management of superconducting devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scanning transmission electron microscopy strain measurement from millisecond frames of a direct electron charge coupled device

A high-speed direct electron detection system is introduced to the field of transmission electron microscopy and applied to strain measurements in semiconductor nanostructures. In particular, a focused electron probe with a diameter of 0.5 nm was scanned over a fourfold quantum layer stack with alternating compressive and tensile strain and diffracted discs have been recorded on a scintillator-free direct electron detector with a frame time of 1 ms. We show that the applied algorithms can accurately detect Bragg beam positions despite a significant point spread each 300 kV electron causes during detection on the scintillator-free camera. For millisecond exposures, we find that strain can be measured with a precision of 1.3 Multiplication-Sign 10{sup -3}, enabling, e.g., strain mapping in a 100 Multiplication-Sign 100 nm{sup 2} region with 0.5 nm resolution in 40 s.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Atomic-layer doping of SiGe heterostructures for atomic-precision donor devices

As a first step to porting scanning tunneling microscopy methods of atomic-precision fabrication to a strained-Si/SiGe platform, we demonstrate post-growth P atomic-layer doping of SiGe heterostructures. To preserve the substrate structure and elastic state, we use a T ≤ 800 °C process to prepare clean Si 0.86 Ge 0.14 surfaces suitable for atomic-precision fabrication. P-saturated atomic-layer doping is incorporated and capped with epitaxial Si under a thermal budget compatible with atomic-precision fabrication. Hall measurements at T = 0.3 K show that the doped heterostructure has R $\square$ = 570 ± 30 Ω , yielding an electron density n e = 2.1 ± 0.1 × 10 14 cm -2 and mobility μ e = 52 ± 3 cm 2 V -1 s -1 , similar to saturated atomic-layer doping in pure Si and Ge. The magnitude of μ e and the complete absence of Shubnikov–de Haas oscillations in magnetotransport measurements indicate that electrons are overwhelmingly localized in the donor layer, and not within a nearby buried Si well. Finally, this conclusion is supported by self-consistent Schrödinger-Poisson calculations that predict electron occupation primarily in the donor layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydrothermal synthesis and magnetic properties of {alpha}-MnO{sub 2} nanowires

Highlights: Black-Right-Pointing-Pointer {alpha}-MnO{sub 2} nanowires were synthesized through the hydrothermal method. Black-Right-Pointing-Pointer Ferromagnetism was observed in the {alpha}-MnO{sub 2} nanowires at 5 K. Black-Right-Pointing-Pointer The N{sub 2} adsorption-desorption experiment shows that surface area of {alpha}-MnO{sub 2} nanowires is 160.4 m{sup 2} g{sup -1}. -- Abstract: In the present study, one-dimensional (1D) {alpha}-MnO{sub 2} nanowires with width of 50-60 nm, length about several micrometers have been successfully prepared under hydrothermal conditions in the presence of sodium carboxymethyl cellulose. The samples were characterized by X-ray diffraction, scanning electron microscope, superconducting quantum interference device and N{sub 2} adsorption-desorption experiment. The magnetic measurement reveals that the {alpha}-MnO{sub 2} nanowires exhibit a ferromagnetic behavior at 5 K and a paramagnetic behavior at 300 K. The N{sub 2} adsorption-desorption experiment shows that surface area is 160.4 m{sup 2} g{sup -1}, which is even larger than those of mesoporous nanostructures. At the same time, the possible formation mechanism for the formation of {alpha}-MnO{sub 2} nanowires has been proposed according to the experimental results.

36 MATERIALS SCIENCE↗