Search for and investigation of extraterrestrial forms of life
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Appropriate nutrient gel solution could be used to precipitate brushite, which becomes hydroxyapatite, mineral found in bones and teeth. Gel can be made from sodium metasilicate and phosphoric acid, or gelatin, or other organic materials that polymerize in presence of acid to get gelantinous medium.
A biomathematical analysis of component interaction in biological systems is given. Two primary types of systems are discussed - open systems and closed systems. The applicability of these systems to life support equipment in spacecraft is analyzed and formulae are provided to demonstrate the effect (theoretical) of closed and open systems in life support systems.
A qualitative assessment of the tendency for pogo instability of the shuttle vehicle in the absence of suppression devices, and the effectiveness of two passive suppressors (the compliant accumulator and the resistive accumulator) in counteracting any tendency toward instability is provided. In addition, the relative effectiveness of three suppressor locations (the low pressure pump (LWOP) inlet and discharge and the high pressure pump (HPOP) inlet) is also evaluated. The primary conclusion of the study is that effective pogo suppression, with passive devices, can be accomplished at the HPOP inlet location but not at the LPOP locations. Other conclusions are drawn regarding the relative effectiveness of the two accumulator types and with respect to tentative accumulator design requirements. Finally, a number of recommendations are made regarding future studies.
An approach for studying hypersonic internal flow with the aid of a thin-shock-layer approximation is discussed, giving attention to a comparison of thin-shock-layer results with the data obtained on the basis of the imposition theory or a finite-difference integration of the Euler equations. Relations in the case of strong interaction are considered together with questions of pressure distribution and aspects of the boundary-layer solution.
The scheduling of space shuttle missions within specified window and resource constraints are reported. Models are described for selecting qualified resource units to the mission assignments.
A high energy density nickel cadmium cell of aerospace quality was designed. The approach used was to utilize manufacturing techniques which produce highly uniform and controlled starting materials in addition to improvements in the overall design. Parameters controlling the production of plaque and both positive and negative plate were studied. Quantities of these materials were produced and prototype cells were assembled to test the proposed design.
The use of active pogo suppressors on the space shuttle was qualitatively investigated. Suppressor design concepts and the effectiveness of these designs in maintaining the stability of the shuttle vehicle were the primary concerns. Suppressor design concepts were developed by means of a series of parametric stability analyses. These two designs together with two designs provided by NASA were evaluated in detail for control effectiveness, performance relative to a passive suppression device, sensitivity of performance to feedback error, suppressor volume flow requirements, and suppressor development requirements. An active device at the high pressure oxidizer pump inlet was shown to provide a simple and effective design that is insensitive to error in the feedback signal. The sizing of an active suppressor was demonstrated to be dependent upon knowledge of the dynamic characteristics of the system.
The intravenous administration of DEHP solubilized by means of a number of different detergents leads to respiratory distress and death in rats. At autopsy the lungs are grossly enlarged, edamatous, and hemorrhagic. Light and electron microscopic evaluation of the lungs indicate engorgement of the interalveolar septa with edema fluid and polymorphonuclear leucocytes, degranulation of the leukocytes, and progessive destruction of the endothelial and epithelial cells. Consistent with the conclusion that solubilized DEHP results in a syndrome of "shock lung" is the associated massive fall in arterial blood pressure and the prevention of the lung pathology by pretreatment with pharmacologic doses of an antiinflammatory steroid, methylprednisolone. Evidence is also presented that suggests that the DEHP inadvertently administered to humans during transfusions is also in a solubilized state in the plasma.
Intravenous administration of 200-300 mg/kg of di(2-ethylhexyl)phthalate (DEHP) solubilized in aqueous solutions of several Tween surfactants caused respiratory distress in rats. There was a dose-dependent lethality with death generally occurring within 90 minutes after injection. The lungs from DEHP:Tween treated animals were enlarged, generally darkened, and in some cases showed hemorrhagic congestion. Neither the overt symptoms nor the morphologic alterations resulting from DEHP:Tween administration could be reproduced by intravenous administration of aqueous Tween solutions alone. The absence of pulmonary abnormalities following the intravenous administration of DEHP as an aqueous emulsion given either alone or even as soon as 2 minutes after pretreatment with Tween 80, suggests that the specific in vivo interaction between DEHP and Tween surfactants depends on the prior formation of water-soluble micelles of DEHP.
Platelet concentrates were shown to contain 18-38 mg/100 ml of a phthalate plasticizer (DEHP) which arose by migration from the vinyl plastic packs in which the plateletes were prepared and stored. Transfusion of these platelets into 6 adult patients with leukemia resulted in peak blood plasma levels of DEHP ranging from 0.34 - 0.83 mg/100 ml. The blood levels fell mono-exponentially with a mean rate of 2.83 percent per minute and a half-life of 28.0 minutes. Urine was assayed by a method that would measure unchanged DEHP as well as all phthalic acid-containing metabolities. In two patients, at most 60 and 90% of the infused dose, respectively, was excreted in the urine collected for 24 hours post-transfusion. These estimates, however, could be high due to the simultaneous excretion of DEHP remaining from previous transfusions or arising from uncontrolled environmental exposures.
The cubic spline collocation procedure for the numerical solution of partial differential equations was reformulated so that the accuracy of the second-derivative approximation is improved and parallels that previously obtained for lower derivative terms. The final result is a numerical procedure having overall third-order accuracy for a nonuniform mesh and overall fourth-order accuracy for a uniform mesh. Application of the technique was made to the Burger's equation, to the flow around a linear corner, to the potential flow over a circular cylinder, and to boundary layer problems. The results confirmed the higher-order accuracy of the spline method and suggest that accurate solutions for more practical flow problems can be obtained with relatively coarse nonuniform meshes.
A cubic spline approximation is presented which is suited for many fluid-mechanics problems. This procedure provides a high degree of accuracy, even with a nonuniform mesh, and leads to an accurate treatment of derivative boundary conditions. The truncation errors and stability limitations of several implicit and explicit integration schemes are presented. For two-dimensional flows, a spline-alternating-direction-implicit method is evaluated. The spline procedure is assessed, and results are presented for the one-dimensional nonlinear Burgers' equation, as well as the two-dimensional diffusion equation and the vorticity-stream function system describing the viscous flow in a driven cavity. Comparisons are made with analytic solutions for the first two problems and with finite-difference calculations for the cavity flow.
A cubic spline approximation is used for the solution of several problems in fluid mechanics. This procedure provides a high degree of accuracy even with a nonuniform mesh, and leads to a more accurate treatment of derivative boundary conditions. The truncation errors and stability limitations of several typical integration schemes are presented. For two-dimensional flows a spline-alternating-direction-implicit (SADI) method is evaluated. The spline procedure is assessed and results are presented for the one-dimensional nonlinear Burgers' equation, as well as the two-dimensional diffusion equation and the vorticity-stream function system describing the viscous flow in a driven cavity. Comparisons are made with analytic solutions for the first two problems and with finite-difference calculations for the cavity flow.
A cubic spline collocation procedure has recently been developed for the numerical solution of partial differential equations. In the present paper, this spline procedure is reformulated so that the accuracy of the second-derivative approximation is improved and parallels that previously obtained for lower derivative terms. The final result is a numerical procedure having overall third-order accuracy for a non-uniform mesh and overall fourth-order accuracy for a uniform mesh. Solutions using both spline procedures, as well as three-point finite difference methods, will be presented for several model problems.-
The status of an investigation of four numerical techniques for the time-dependent compressible Navier-Stokes equations is presented. Results for free shear layer calculations in the Reynolds number range from 1000 to 81000 indicate that a sequential alternating-direction implicit (ADI) finite-difference procedure requires longer computing times to reach steady state than a low-storage hopscotch finite-difference procedure. A finite-element method with cubic approximating functions was found to require excessive computer storage and computation times. A fourth method, an alternating-direction cubic spline technique which is still being tested, is also described.
A cubic spline collocation procedure was developed for the numerical solution of partial differential equations. This spline procedure is reformulated so that the accuracy of the second-derivative approximation is improved and parallels that previously obtained for lower derivative terms. The final result is a numerical procedure having overall third-order accuracy of a nonuniform mesh. Solutions using both spline procedures, as well as three-point finite difference methods, are presented for several model problems.
Correct combinations of remote, analytic, and functional methods and measuring devices for detecting extraterrestrial life are elaborated. Considered are techniques and instruments available both on earth and aboard spacecraft and artificial planetary satellites. Emphasis is placed on the abiogenetic synthesis of organic compounds formed in photosynthesis on Mars.