Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Risk Register”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A general model for stray dose calculation of static and intensity-modulated photon radiation

Purpose: There is an increasing number of cancer survivors who are at risk of developing late effects caused by ionizing radiation such as induction of second tumors. Hence, the determination of out-of-field dose for a particular treatment plan in the patient’s anatomy is of great importance. The purpose of this study was to analytically model the stray dose according to its three major components. Methods: For patient scatter, a mechanistic model was developed. For collimator scatter and head leakage, an empirical approach was used. The models utilize a nominal beam energy of 6 MeV to describe two linear accelerator types of a single vendor. The parameters of the models were adjusted using ionization chamber measurements registering total absorbed dose in simple geometries. Whole-body dose measurements using thermoluminescent dosimeters in an anthropomorphic phantom for static and intensity-modulated treatment plans were compared to the 3D out-of-field dose distributions calculated by a combined model. Results: The absolute mean difference between the whole-body predicted and the measured out-of-field dose of four different plans was 11% with a maximum difference below 44%. Computation time of 36 000 dose points for one field was around 30 s. By combining the model-calculated stray dose with the treatment planning system dose, the whole-body dose distribution can be viewed in the treatment planning system. Conclusions: The results suggest that the model is accurate, fast and can be used for a wide range of treatment modalities to calculate the whole-body dose distribution for clinical analysis. For similar energy spectra, the mechanistic patient scatter model can be used independently of treatment machine or beam orientation.

60 APPLIED LIFE SCIENCES↗

Risk Assessment of Catastrophic Leak Of R-452b From Package Unit into A Residential Space

With the effort to find alternative refrigerants with lower global warming potential (GWP), challenges have arisen due to the flammability risk for many of the alternatives. One of the new alternatives is R-452B, which is recommended as a replacement for R410A. R-452B is classified as a mildly flammable refrigerant (A2L) by ANSI/ASHRAE Standard 34. This paper summarizes a computational fluid dynamic (CFD) simulation study of a leak incident of R-452B from a 3-ton packaged unit which serves a 167 m 2 residence. The R-452B leak is assumed to be downstream of the evaporator coil. The simulated residence has four rooms and a hallway. The packaged unit distributes the conditioned air through a supply duct system delivering the air through registers. The dispersion of R-452B is characterized for two scenarios: one with underfloor supply air ducts and another with ceiling supply air ducts. The mass flow rate of R-452B exiting the duct outlets is quantified and the refrigerant volume fraction is monitored inside the residential space.

42 ENGINEERING↗

Creating 3D Models With The Faro Scanner

The Faro Focus X 330 is a 3D scanner that combines numerous technologies in order to create a precise and life like 3D model. The technologies used by the scanner include: Time of flight (The scanner spins horizontally and vertically while emitting a class 1 laser; The laser beam then bounces off of an object and is captured by a sensor; An extremely precise chronometer tracks the beams flight time; The data is inputted into the simple formula: d=c*t/2). Point cloud system: The exact position of up to 976,000 points per second are registered and combined to form a complete model with up to ±1 mm at 330 m. Camera: Photos are taken of the surroundings that are combined to make a 165 megapixel image. The image is paired with the point cloud system. Scans have been taken of buildings 730-A and 781-A. These scans will be put into different virtual reality programs and used for tours and training. The scans also serve as a proof of concept for the Faro Focus X 330 as well as SRNL's ability to produce accurate scans with numerous useful applications. Work Scope Planning: Scanning will result in higher productivity and reduce the risk by identifying hazards; Blueprints and designs; 3D scans allow greater collaboration between engineers, construction crews, etc. by enabling them to compare blueprints to real time progress and make adjustments. Training and walk-downs: Scans can be made of places where access is not readily available, this could be due to its remote location or hazards such as radioactivity.

42 ENGINEERING↗

Automated treatment planning for a dedicated multi-source intracranial radiosurgery treatment unit using projected gradient and grassfire algorithms

Purpose: The purpose of this work is to develop a framework to the inverse problem for radiosurgery treatment planning on the Gamma Knife{sup Registered-Sign} Perfexion Trade-Mark-Sign (PFX) for intracranial targets. Methods: The approach taken in the present study consists of two parts. First, a hybrid grassfire and sphere-packing algorithm is used to obtain shot positions (isocenters) based on the geometry of the target to be treated. For the selected isocenters, a sector duration optimization (SDO) model is used to optimize the duration of radiation delivery from each collimator size from each individual source bank. The SDO model is solved using a projected gradient algorithm. This approach has been retrospectively tested on seven manually planned clinical cases (comprising 11 lesions) including acoustic neuromas and brain metastases. Results: In terms of conformity and organ-at-risk (OAR) sparing, the quality of plans achieved with the inverse planning approach were, on average, improved compared to the manually generated plans. The mean difference in conformity index between inverse and forward plans was -0.12 (range: -0.27 to +0.03) and +0.08 (range: 0.00-0.17) for classic and Paddick definitions, respectively, favoring the inverse plans. The mean difference in volume receiving the prescribed dose (V{sub 100}) between forward and inverse plans was 0.2% (range: -2.4% to +2.0%). After plan renormalization for equivalent coverage (i.e., V{sub 100}), the mean difference in dose to 1 mm{sup 3} of brainstem between forward and inverse plans was -0.24 Gy (range: -2.40 to +2.02 Gy) favoring the inverse plans. Beam-on time varied with the number of isocenters but for the most optimal plans was on average 33 min longer than manual plans (range: -17 to +91 min) when normalized to a calibration dose rate of 3.5 Gy/min. In terms of algorithm performance, the isocenter selection for all the presented plans was performed in less than 3 s, while the SDO was performed in an average of 215 min. Conclusions: PFX inverse planning can be performed using geometric isocenter selection and mathematical modeling and optimization techniques. The obtained treatment plans all meet or exceed clinical guidelines while displaying high conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-BRF-09: Integration of High-Resolution MRSI Into Glioblastoma Treatment Planning

Purpose: Identification of a metabolite signature that shows significant tumor cell infiltration into normal brain in regions that do not appear abnormal on standard MRI scans would be extremely useful for radiation oncologists to choose optimal regions of brain to treat, and to quantify response beyond the MacDonald criteria. We report on integration of high-resolution magnetic resonance spectroscopic imaging (HR-MRSI) with radiation dose escalation treatment planning to define and target regions at high risk for recurrence. Methods: We propose to supplement standard MRI with a special technique performed on an MRI scanner to measure the metabolite levels within defined volumes. Metabolite imaging was acquired using an advanced MRSI technique combining 3D echo-planar spectroscopic imaging (EPSI) with parallel acquisition (GRAPPA) using a multichannel head coil that allows acquisition of whole brain metabolite maps with 108 μl resolution in 12 minutes implemented on a 3T MR scanner. Elevation in the ratio of two metabolites, choline (Cho, elevated in proliferating high-grade gliomas) and N-acetyl aspartate (NAA, a normal neuronal metabolite), was used to image infiltrating high-grade glioma cells in vivo. Results: The metabolite images were co-registered with standard contrast-enhanced T1-weighted MR images using in-house registration software and imported into the treatment-planning system. Regions with tumor infiltration are identified on the metabolic images and used to create adaptive IMRT plans that deliver a standard dose of 60 Gy to the standard target volume and an escalated dose of 75 Gy (or higher) to the most suspicious regions, identified as areas with elevated Cho/NAA ratio. Conclusion: We have implemented a state-of-the-art HR-MRSI technology that can generate metabolite maps of the entire brain in a clinically acceptable scan time, coupled with introduction of an imaging co-registration/ analysis program that combines MRSI data with standard imaging studies in a clinically useful fashion.

60 APPLIED LIFE SCIENCES↗

Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing patients met protocol guidelines with maximum dose and dose to 100% of hippocampus (D{sub 100%}) less than 16 and 9 Gy, respectively. The dose to the optic apparatus was kept below protocol guidelines for all 5 patients. Highly conformal and homogenous radiosurgical dose distributions were achieved for all 5 patients with a total of 33 brain metastases. The m-BM PTVs had a mean HI = 0.09 ± 0.02 (range: 0.07 to 0.19) and a mean CI = 1.02 ± 0.06 (range: 0.93 to 1.2). The total number of monitor units (MU) was, on average, 1677 ± 166. The average beam-on time was 4.1 ± 0.4 minute . The IMAT plans demonstrated accurate dose delivery of 95.2 ± 0.6%, on average, for clinical gamma passing rate with 2%/2-mm criteria and 98.5 ± 0.9%, on average, with 3%/3-mm criteria. Conclusions: All hippocampal sparing plans were considered clinically acceptable per NRG-CC001 dosimetric compliance criteria. IMAT planning provided highly conformal and homogenous dose distributions for the WB-PTV and m-BM PTVs with lower doses to OAR such as the hippocampus. These results suggest that HS-WBRT with SIB is a clinically feasible, fast, and effective treatment option for patients with a relatively large numbers of m-BM lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-536: Inhomogeneity Correction in Planning of Gamma Knife Treatments for Acoustic Schwannoma

Purpose: To find out the dose difference on targets and organs at risk for the treatment of acoustic schwannoma if the inhomogeneity correction (Convolution algorithm) is applied. Methods: Images of patients treated for acoustic schwannoma with Gamma Knife using TMR 10 algorithm were retrieved from database and replanned with Convolution and TMR 10 algorithm respectively. These patients were treated using a preplan scheme in following: (1) Before the actual treatment day, using the MRI image that was taken without a head frame on the patient's skull, a pre-treatment plan was made based on the default skull coordinates in the Gamma Knife treatment planning system (LGP); (2) then on treatment day, a head frame was placed on the patient's skull, and a CT image was taken. The CT image with head frame was registered and fused with the completed preplan; (3) the treatment plan was finalized and the treatment was delivered. To find out the dosimetry impact of inhomogeneity correction, we used the retrieved CT images to replan the treatment using Convolution algorithm in LGP software version 10.1.1. The dose distributions and the dose volume histograms for targets and OARs were compared for these two dose calculation algorithms. Results: The dose calculated with the Convolution algorithm in general is slightly lower than the one from TMR 10 around the boney area. The effect from the inhomogeneity correction is observable but not significant, and varies with the location of the tumor. Conclusion: Inhomogeneity correction slightly improve the dose accuracy for acoustic schwannoma Gamma Knife treatments although the correction may not be very significant. Our Result provides evidence for dose prescription adjustment to treat acoustic schwannoma. The actual clinical outcome of switching from using TMR10 to using Convolution needs to be further investigated.

60 APPLIED LIFE SCIENCES↗

Re-Planning for Compensator-Based IMRT with Original Compensators

Compared with multileaf collimator (MLC)-based intensity-modulated radiotherapy (IMRT) for moving targets, compensator-based IMRT has advantages such as shorter beam-on time, fewer monitor units with potentially decreased secondary carcinogenesis risk, better optimization-to-deliverable dose conversion, and often better dose conformity. Some of the disadvantages include additional time for the compensators to be built and delivered, as well as extra cost. Patients undergoing treatment of abdominal cancers often experience weight loss. It would be necessary to account for this change in weight with a new plan and a second set of compensators. However, this would result in treatment delays and added costs. We have developed a method to re-plan the patient using the same set of compensators. Because the weight changes seen with the treatment of abdominal cancers are usually relatively small, a new 4D computed tomography (CT) acquired in the treatment position with markers on the original isocenter tattoos can be registered to the original planning scan. The contours of target volumes from the original scans are copied to the new scan after fusion. The original compensator set can be used together with a few field-in-field (FiF) beams defined by the MLC (or beams with cerrobend blocks for accelerators not equipped with a MLC). The weights of the beams with compensators are reduced so that the FiF or blocked beams can be optimized to mirror the original plan and dose distribution. Seven abdominal cancer cases are presented using this technique. The new plan on the new planning CT images usually has the same dosimetric quality as the original. The target coverage and dose uniformity are improved compared with the plan without FiF/block modification. Techniques combining additional FiF or blocked beams with the original compensators optimize the treatment plans when patients lose weight and save time and cost compared with generating plans with a new set of compensators.

61 RADIATION PROTECTION AND DOSIMETRY↗

Adiabatic Compression Sensitivity of Liquid Fuels and Monopropellants

Liquid rocket propellants can be sensitive to rapid compression. Such liquids may undergo decomposition and their handling may be accompanied with risk. Decomposition produces small gas bubbles in the liquid, which upon rapid compression may cause catastrophic explosions. The rapid compression can result from mechanical shocks applied on the tank containing the liquid or from rapid closure of the valves installed on the lines. It is desirable to determine the conditions that may promote explosive reactions. At Air Force Research Laboratory (AFRL), we constructed an apparatus and established a safe procedure for estimating the sensitivity of propellant materials towards mechanical shocks (Adiabatic Compression Tester). A sample is placed on a stainless steel U-tube, held isothermally at a temperature between 20 and 150 C then exposed to an abrupt mechanical shock of nitrogen gas at a pressure between 6.9 and 20.7 MPa (1000 to 3000 psi). The apparatus is computer interfaced and is driven with LABTECH NOTEBOOK-pro (registered) Software. In this presentation, the design of the apparatus is shown, the operating procedure is outlined, and the safety issues are addressed. The results obtained on different energetic materials are presented.

Ismail, Ismail M. K.↗

Growth and biochemical composition of the carrageenophyte Eucheumatopsis isiformis (Solieriaceae, Rhodophyta) under cultivation at different irradiance levels

Long-term production of a few species of Eucheuma and Kappaphycus from the Indo-Pacific Ocean supports the global carrageenan industry. The widespread use of vegetative propagation has resulted in low genetic diversity among farmed populations, making these crops increasingly vulnerable to diseases and environmental stressors, and resulting in declining yields and reduced biomass production over time. Insufficient efforts to develop and select new native cultivars, combined with the ecological risks posed by introducing nonindigenous species, underscore the urgent need to enhance cultivar diversification in eucheumatoid farming. Eucheumatopsis isiformis , a native carrageenophyte to the Atlantic Ocean, has potential for its cultivation in the Yucatán peninsula, Mexico. This study evaluated the growth and biochemical composition (pigments, elemental C and N, kappa/iota carrageenan ratio) of E. isiformis under different irradiance conditions in an indoor cultivation system. Specimens were collected in a subtidal population in Yucatán, Mexico, characterized, acclimatized to laboratory conditions, and exposed to five irradiance levels (71 ± 10.59 –1014 ± 65.85 µmol quanta m −2 s −1 ; 23.4 °C, salinity 33–34). Growth was measured weekly for six weeks, and elemental C and N content, pigment composition, and the kappa/iota-carrageenan ratio were evaluated. Growth and chromatic photoacclimation to light conditions were observed in all treatments. Highest growth rates (3.1–3.2% day −1 ) were registered between 238 ± 28.3 – 518 ± 44.3 µmol quanta m −2 s −1 , with a predominant iota-type carrageenan (0.97 ± 0.02) observed in all treatments. This study aims to provide guidelines for the successful development of the aquaculture of this carrageenophyte.

FTIR↗

The Role of 'Cutting' Balloon Angioplasty for the Treatment of Short Femoral Bifurcation Steno-Obstructive Disease

This study was designed to report our experience with 'cutting' balloon angioplasty (CBA) for the treatment of short femoral bifurcation arterial stenosis. Between March 2005 and September 2007, 18 consecutive patients who were high-risk for surgery with critical limb ischemia or severe lifestyle-limiting claudication underwent 'cutting' balloon angioplasty (4-6 mm diameter/15-20-mm length) for the treatment of 27 focal (<3 cm) severe fibro-calcified stenosis of the common femoral artery (n = 14) and/or the proximal part of the superficial femoral artery (n = 6) or profunda femoris (n = 7). Baseline patient demographic data, pre- and post-procedural patient clinical data, and procedural results were recorded. Follow-up consisted of clinical check-up and color duplex ultrasonography (CDU) examination 1, 3, 6, 12, and 18 months after the procedure. All endovascular treatments were successfully performed with clinical success obtained for all patients. No complications occurred during all treatments and no patient required surgical conversion or placement of a stent because of recoil, dissection, or arterial tears. No acute vessel closure was registered. During a mean follow-up of 9.4 (range, 6-18) months, endovascular treatment (CBA) was performed for restenosis/occlusion of seven lesions (25.9%) in four patients, whereas surgical treatment (endarterectomy with patch) for restenosis/occlusion of three lesions (11.1%) was performed in two patients with a consequent reintervention rate of 37%. Primary and secondary patency rates were 84.6 and 88.4% at 6 months and 57.9 and 79.6% at 12 months, respectively. No major limb amputation was performed, with a 12-month limb salvage rate of 88.9%. CBA seems to be a valuable tool for the endovascular treatment of focal femoral bifurcation stenotic lesions for patients who are poor candidates for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-OPERA: A Multicenter/Multivendor Validation of Magnetic Resonance Imaging–Only Prostate Treatment Planning Using Synthetic Computed Tomography Images

Purpose: To validate the dosimetric accuracy and clinical robustness of a commercially available software for magnetic resonance (MR) to synthetic computed tomography (sCT) conversion, in an MR imaging–only workflow for 170 prostate cancer patients. Methods and Materials: The 4 participating centers had MriPlanner (Spectronic Medical), an atlas-based sCT generation software, installed as a cloud-based service. A T2-weighted MR sequence, covering the body contour, was added to the clinical protocol. The MR images were sent from the MR scanner workstation to the MriPlanner platform. The sCT was automatically returned to the treatment planning system. Four MR scanners and 2 magnetic field strengths were included in the study. For each patient, a CT-treatment plan was created and approved according to clinical practice. The sCT was rigidly registered to the CT, and the clinical treatment plan was recalculated on the sCT. The dose distributions from the CT plan and the sCT plan were compared according to a set of dose-volume histogram parameters and gamma evaluation. Treatment techniques included volumetric modulated arc therapy, intensity modulated radiation therapy, and conventional treatment using 2 treatment planning systems and different dose calculation algorithms. Results: The overall (multicenter/multivendor) mean dose differences between sCT and CT dose distributions were below 0.3% for all evaluated organs and targets. Gamma evaluation showed a mean pass rate of 99.12% (0.63%, 1 SD) in the complete body volume and 99.97% (0.13%, 1 SD) in the planning target volume using a 2%/2-mm global gamma criteria. Conclusions: Results of the study show that the sCT conversion method can be used clinically, with minimal differences between sCT and CT dose distributions for target and relevant organs at risk. The small differences seen are consistent between centers, indicating that an MR imaging–only workflow using MriPlanner is robust for a variety of field strengths, vendors, and treatment techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Finding Of Adverse Effect and Proposed Mitigation for the Removal of Joshua Trees at Building 23-210, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) recently removed two fallen Joshua trees that were part of an Accessory Resource (AR) to the former Department of Defense (DOD) Motor Pool Maintenance Compound in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. C307) on the Nevada National Security Site (NNSS) in Nye County, Nevada (Figure 1). The Joshua trees were part of AR3, a landscaped feature at the entrance to the compound. There are two remaining Joshua trees at risk of falling which may require removal in the future. The NNSA/NFO is proactively consulting with the SHPO regarding the potential removal of the remaining two trees. The purpose of the undertaking is to ensure that dead or dying Joshua trees do not cause damage to the remaining landscape elements, nor injury to NNSS employees. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-210 was the DOD’s motor vehicle maintenance compound constructed in 1951. The compound included its own repair shop and fuel station. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (National Register, NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992. The former DOD Motor Pool Compound was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). The foundation for Building 23-210 was also identified in Appendix C of the Mercury PA as a Category III contributing element with three contributing ARs. Category III properties are those that may include elements for which there are several representatives in the MHD, such as foundations, and those elements which possess characteristics that are not unique to the MHD and are commonly found in other non-NNSS facilities. The former DOD compound, which is identified by the foundation for the Building 23-210 and its ARs, is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Integrating tools for non-targeted analysis research and chemical safety evaluations at the US EPA

Tens-of-thousands of chemicals are registered in the U.S. for use in countless processes and products. Recent evidence suggests that many of these chemicals are measureable in environmental and/or biological systems, indicating the potential for widespread exposures. Traditional public health research tools, including in vivo studies and targeted analytical chemistry methods, have been unable to meet the needs of screening programs designed to evaluate chemical safety. As such, new tools have been developed to enable rapid assessment of potentially harmful chemical exposures and their attendant biological responses. One group of tools, known as “nontargeted analysis” (NTA) methods, allows the rapid characterization of thousands of never-before-studied compounds in a wide variety of environmental, residential, and biological media. This article discusses current applications of NTA methods, challenges to their effective use in chemical screening studies, and ways in which shared resources (e.g., chemical standards, databases, model predictions, and media measurements) can advance their use in risk-based chemical prioritization. A brief review is provided of resources and projects within EPA’s Office of Research and Development (ORD) that provide benefit to, and receive benefits from, NTA research endeavors. A summary of EPA’s Non-Targeted Analysis Collaborative Trial (ENTACT) is also given, which makes direct use of ORD resources to benefit the global NTA research community. Finally, a research framework is described that shows how NTA methods will bridge chemical prioritization efforts within ORD. This framework exists as a guide for institutions seeking to understand the complexity of chemical exposures, and the impact of these exposures on living systems.

54 ENVIRONMENTAL SCIENCES↗

TU-FG-201-07: Development of SRS Conical Collimator Collision Prediction Software for Radiation Treatment Safety

Purpose: Stereotactic radiosurgery (SRS) treatments using conical collimators can potentially result in gantry collision with treatment table due to limited collision-clear spaces. An in-house software was developed to help the SRS treatment planner mitigate potential SRS conical collimator (Varian Medical System, Palo Alto, CA) collisions with the treatment table. This software was designed to remove treatment re-planning secondary to unexpected collisions. Methods: A BrainLAB SRS ICT Frameless Extension used for SRS treatments in our clinic was mathematically modelled using surface points registered to the 3D co-ordinate space of the couch extension. The surface points are transformed based on the treatment isocenter point and potential collisions are determined in 3D space for couch and gantry angle combinations. The distance between the SRS conical collimators and LINAC isocenter is known. The collision detection model was programmed in MATLAB (Mathwork, Natick, MA) to display graphical plots of the calculations, and the plotted data is used to avoid the gantry and couch angle combinations that would likely result in a collision. We have utilized the cone collision tool for 23 SRS cone treatment plans (8 retrospective and 15 prospective for 10 patients). Results: Twenty one plans strongly agreed with the software tool prediction for collision. However, in two plans, a collision was observed with a 0.5 cm margin when the software predicted no collision. Therefore, additional margins were added to the clearance criteria in the program to achieve a lower risk of actual collisions. Conclusion: Our in-house developed collision check software successfully avoided SRS cone re-planning by 91.3% due to a reduction in cone collisions with the treatment table. Future developments to our software will include a CT image data set based collision prediction model as well as a beam angle optimization tool to avoid normal critical tissues as well as previously treated lesions.

60 APPLIED LIFE SCIENCES↗

Methods to Register Models and Input/Output Parameters for Integrated Modeling

Significant resources can be required when constructing integrated modeling systems. In a typical application, components (e.g., models and databases) created by different developers are assimilated, requiring the framework’s functionality to bridge the gap between the user’s knowledge of the components being linked. The framework, therefore, needs the capability to assimilate a wide range of model-specific input/output requirements as well as their associated assumptions and constraints. The process of assimilating such disparate components into an integrated modeling framework varies in complexity and difficulty. Several factors influence the relative ease of assimilating components, including, but not limited to, familiarity with the components being assimilated, familiarity with the framework and its tools that support the assimilation process, level of documentation associated with the components and the framework, and design structure of the components and framework. This initial effort reviews different approaches for assimilating models and their model-specific input/output requirements: 1) modifying component models to directly communicate with the framework (i.e., through an Application Programming Interface), 2) developing model-specific external wrappers such that no component model modifications are required, 3) using parsing tools to visually map pre-existing input/output files, and 4) describing and linking models as dynamic link libraries. Most of these approaches are illustrated using the widely distributed modeling system called Framework for Risk Analysis in Multimedia Environmental Systems (FRAMES). The review concludes that each has its strengths and weakness, the factors that determine which approaches work best in a given application.

Data Transfer↗

TU-H-CAMPUS-JeP2-04: Deriving Delivered Doses to Assess the Viability of 2.5 Mm Margins in Head and Neck SBRT

Purpose: To calculate the delivered dose for head and neck SBRT patients using pre-treatment images. This delivered dose was then used to determine the viability of 2.5 mm margins. Methods: Daily cone beam CTs (CBCTs) were collected for 20 patients along with a planning CT, planned dose, and planning structures. The day 1 CBCT was aligned to the planning CT using the treatment shifts (six degrees of freedom) and then the dose and contours were transferred to the CBCT. The day 1 CBCT becomes the reference image for days 2–5. The day 2–5 CBCTs were also aligned to the planning CT using the treatment shifts given and the dose transferred. The day 2–5 CBCTs were then deformably registered to the day 1 CBCT. The doses delivered on days 2–5 were then deformed to the day 1 CBCT where they could be accumulated. This was achieved with MIM 6.5.1 (MIM Software, Cleveland OH). The accumulated doses for the 20 patients were evaluated against the planned doses using the initial planning criteria as points of comparison. Results: The delivered CTV dose conformed to the planned 98.6% coverage, with an average decrease of 2.6% between planned and delivered coverage. This implies the 2.5 mm margin was sufficient. Larger CTVs correlated to smaller differences between planned and delivered coverage. Delivered dose to critical structures including the spinal cord, mandible, brain, brainstem, and larynx was acceptable, with differences between planned and delivered max dose <5% on average. Similarly for the parotid glands, globes, cochlear, optic nerve, lens, and submandibular glands, differences between planned and delivered doses were generally <5%. Conclusion: The 2.5 mm margin provided acceptable CTV coverage, adequately accounting for setup errors. Organ at risk sparing was also satisfactory. Small tumor volumes (<20 cc) may require a larger margin to treat effectively.

60 APPLIED LIFE SCIENCES↗

Clinical Outcome of Patients Treated With 3D Conformal Radiation Therapy (3D-CRT) for Prostate Cancer on RTOG 9406

Purpose: Report of clinical cancer control outcomes on Radiation Therapy Oncology Group (RTOG) 9406, a three-dimensional conformal radiation therapy (3D-CRT) dose escalation trial for localized adenocarcinoma of the prostate. Methods and Materials: RTOG 9406 is a Phase I/II multi-institutional dose escalation study of 3D-CRT for men with localized prostate cancer. Patients were registered on five sequential dose levels: 68.4 Gy, 73.8 Gy, 79.2 Gy, 74 Gy, and 78 Gy with 1.8 Gy/day (levels I-III) or 2.0 Gy/day (levels IV and V). Neoadjuvant hormone therapy (NHT) from 2 to 6 months was allowed. Protocol-specific, American Society for Therapeutic Radiation Oncology (ASTRO), and Phoenix biochemical failure definitions are reported. Results: Thirty-four institutions enrolled 1,084 patients and 1,051 patients are analyzable. Median follow-up for levels I, II, III, IV, and V was 11.7, 10.4, 11.8, 10.4, and 9.2 years, respectively. Thirty-six percent of patients received NHT. The 5-year overall survival was 90%, 87%, 88%, 89%, and 88% for dose levels I-V, respectively. The 5-year clinical disease-free survival (excluding protocol prostate-specific antigen definition) for levels I-V is 84%, 78%, 81%, 82%, and 82%, respectively. By ASTRO definition, the 5-year disease-free survivals were 57%, 59%, 52%, 64% and 75% (low risk); 46%, 52%, 54%, 56%, and 63% (intermediate risk); and 50%, 34%, 46%, 34%, and 61% (high risk) for levels I-V, respectively. By the Phoenix definition, the 5-year disease-free survivals were 68%, 73%, 67%, 84%, and 80% (low risk); 70%, 62%, 70%, 74%, and 69% (intermediate risk); and 42%, 62%, 68%, 54%, and 67% (high risk) for levels I-V, respectively. Conclusion: Dose-escalated 3D-CRT yields favorable outcomes for localized prostate cancer. This multi-institutional experience allows comparison to other experiences with modern radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗