Assessing the Performance, Application, and Cost of Retrofit Wall Systems for Residential Buildings

The Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and the University of Minnesota have been conducting a three-year study of residential retrofit wall systems. The researchers have identified, tested, and verified the hygrothermal performance of 16 wall assemblies in retrofit applications. The approach to this study includes a comprehensive literature review, the involvement of an advisory group of thermal enclosure experts, smallscale experimental in situ testing of the wall assemblies at the University of Minnesota’s Cloquet Residential Research Facility, and energy and hygrothermal simulation of wall assemblies using EnergyPlus, THERM, and WUFI. Simulation and experimental results are then combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits.This presentation summarizes the findings of this research project and is intended to guide architects and designers on how to retrofit existing wall assemblies without creating durability issues.

Desjarlais, Andre Omer↗

Development and Evaluation of Occupancy-Aware HVAC Control for Residential Building Energy Efficiency and Occupant Comfort

Occupancy-aware heating, ventilation, and air conditioning (HVAC) control offers the opportunity to reduce energy use without sacrificing thermal comfort. Residential HVAC systems often use manually-adjusted or constant setpoint temperatures, which heat and cool the house regardless of whether it is needed. By incorporating occupancy-awareness into HVAC control, heating and cooling can be used for only those time periods it is needed. Yet, bringing this technology to fruition is dependent on accurately predicting occupancy. Non-probabilistic prediction models offer an opportunity to use collected occupancy data to predict future occupancy profiles. Smart devices, such as a connected thermostat, which already include occupancy sensors, can be used to provide a continually growing collection of data that can then be harnessed for short-term occupancy prediction by compiling and creating a binary occupancy prediction. Real occupancy data from six homes located in Colorado is analyzed and investigated using this occupancy prediction model. Results show that non-probabilistic occupancy models in combination with occupancy sensors can be combined to provide a hybrid HVAC control with savings on average of 5.0% and without degradation of thermal comfort. Model predictive control provides further opportunities, with the ability to adjust the relative importance between thermal comfort and energy savings to achieve savings between 1% and 13.3% depending on the relative weighting between thermal comfort and energy savings. In all cases, occupancy prediction allows the opportunity for a more intelligent and optimized strategy to residential HVAC control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

air-source heat pumps↗

Designing for Supply and Return Air System Interaction in Residential Buildings

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms . In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology – or layout - impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This fact sheet considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold. A complete description of the modeling work and results can be found in the companion technical report.

buildings↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

27 ARPA - Advanced Research Projects Agency-Energy↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings: Preprint

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time MPC for Residential Building Water Heater Systems to Support the Electric Grid

The world of IoT (internet of things) is spawning new control options and decision making that has not been available before. This is providing a wealth of opportunities for transactive type controls and systems that can negotiate for a common goal. This paper discusses a transactive residential neighborhood with optimization at the home level utilizing a system of agents. The real-time optimization utilizes information and modeling to optimize heat pump water heater operation in occupied homes. Data is presented showing the performance of the optimization and conclusions are drawn on next steps for development.

Starke, Michael↗

Hygrothermal Performance of Bio-Based Materials in Residential Building Wall Envelope Systems

In the United States, building envelope systems contribute approximately 28% of building energy consumption, with walls being a primary factor. As the construction industry explores new approaches to lower the energy intensity needed to manufacture materials and, in turn, reduce energy consumption, bio-based materials are gaining attention as a promising alternative. While prior studies have demonstrated that bio-based materials can decrease material energy intensity, their long-term hygrothermal behavior within a whole residential wall system is not yet fully understood. This study aims to evaluate the potential of replacing Oriented Strand Board (OSB) and drywall in residential wall systems with bio-based alternatives. The research focuses on two bio-based materials, assessing their hygrothermal performance under Chicago climate condition (Climate Zone 5). To achieve that, a series of laboratory experiments were conducted to measure key properties of the bio-based materials such as thickness, dimensions, density, thermal conductivity (as a function of temperature and humidity), moisture-dependent permeance and water vapor permeability (WVP), and sorption isotherms. These properties were then used in WUFI® simulations to predict the moisture durability of a standard residential wall system in Climate Zone 5. Results show that substituting OSB and drywall with bio-based materials can achieve acceptable moisture durability, effectively mitigating risks of mold growth and structural damage over time.

Palani, Hevar [ORNL] (ORCID:0000000220211994)↗

Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings

An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the ‘direct-DC house’ with respect to today’s typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly influenced by climate. While direct-DC for residential applications will most likely arise as a spin-off of developments in the commercial sector—because of lower barriers to market entry and larger energy benefits resulting from the higher coincidence between load and insolation—this paper demonstrates that there are substantial benefits in the residential sector as well. Among residential applications, space cooling derives the largest energy savings from being delivered by a direct-DC system. It is the largest load for the average residence on a national basis and is particularly so in high-load regions. It is also the load with highest solar coincidence.

14 SOLAR ENERGY↗

FTR for: Reducing plug-load electricity footprint of residential buildings through low-cost, non-intrusive sub-metering and personalized feedback technology

The project started in October 2016 and ended in December 2022. The project's principal goals and achievements were: (i) Measure real and reactive electric power consumption in ~400 apartments in multifamily settings of varying size and vintage and publish the data; data was published according to New York State's recommended 15x15 rule continuously from Jan 2019 through December 2022 (10 second time resolution); with the combination of large number of apartments, real and reactive power, as well as high time resolution (10-seconds), the dataset is first of its kind worldwide; because the dataset New York City apartment consumption pre, during, and post pandemic, it further offers unique insights into changes in residential electricity consumption during lockdowns and after modified work from home schedules. (ii) Measure effectiveness of different feedback types to prompt residents to lower their electricity consumption; achieved 11% (kWh-weighted) reduction versus baseline consumption; confirmed previous studies that social comparisons elicit above average responses; showed, for the first time, that the so called boomerang effect in power consumption feedback projects can be explained by a previously hypothesized norm-conforming "magnet effect" (rather than a non-conforming defiance effect), thus substantially advancing the research in the field. (iii) Disaggregate apartment-level consumption to appliance level; because the hardware for electricity consumption unexpectedly allowed only for 10-second time resolution (rather than the 1-second resolution we had planned on), the disaggregation algorithms we developed on sample data could not be applied to the actual field data we collected. The project has yielded high visibility, with a total of 17 publications, from peer reviewed journals, published data sets (free access), blog posts, NY Times, National Public Radio, and CNN.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparative life cycle assessment of a modular cross-laminated timber residential building designed for disassembly and reuse versus traditional wood frame construction

There is a need for affordable housing across the U.S., with high-performance modular and prefabricated buildings providing a logical avenue for meeting some of this demand. However, there is a need to balance high performance construction – including low emissions – with affordability. To provide a proof-of-concept in meeting these goals, the Circular Home is a cross-laminated timber (CLT)-based deconstructible and reconfigurable single-family residence that meets high performance targets in moisture, energy, design, economics, and life cycle assessment (LCA). This study focuses on the LCA, presenting a cradle-to-cradle whole-building life cycle assessment (WBLCA) for the Circular Home and a functionally equivalent Baseline Home constructed with traditional materials and methods. The functional unit is 1 m 2 of gross floor area across 60 years. Revit building information models (BIM) provided material quantities and Tally LCA was utilized for impact data (inclusive of biogenic carbon sequestration), supplemented with manufacturer environmental product declarations (EPDs). The Circular Home outperforms the baseline residence in most measured impact categories, including global warming potential (GWP), producing −2.73 kgCO 2 eq/m 2 in embodied emissions, whereas the modeled baseline has an embodied GWP of 428 kgCO 2 eq/m 2 . The careful material selection and advanced building design optimizes performance, with the Circular Home containing only −0.006 times the embodied emissions and −0.02 times the operational emissions of its traditional counterpart. Finally, the unique contribution of this work is in the environmental impact comparison of a high-performance modular CLT structure that can be affordably scaled and mass produced in a U.S. market, compared to typical single family home construction.

Circularity↗

A comparative energy analysis of three electrochromic glazing technologies in commercial and residential buildings

Here, we present a simulation study of three dynamic electrochromic window glazings, including a novel glazing capable of independently modulating its optical properties in both the visible and near-infrared spectrums. This capability allows this so-called “dual-band” technology to actively manage the solar heat and visible light transmitted into a building's interior, and creates the potential for heating, cooling, and lighting savings vis-à-vis competing window technologies. In this study EnergyPlus is used to simulate annual energy performance of the dual-band electrochromic (DBEC) glazing in three building types and 16 U.S. climate regions. The savings potential of DBEC windows are presented relative to a conventional electrochromic glazing; a visibly transparent, near-infrared switching electrochromic glazings; and several static alternatives, including ASHRAE 90-2010 standard compliant windows. Results indicate that the DBEC glazings are capable of outperforming alternatives in a diverse set of locations and building types, including both heating and cooling-dominated regions. Relative to code-compliant static windows, the DBEC is capable of achieving annual primary energy savings between 6 and 30 kW h/ft 2 of window area from reduced heating, cooling, and lighting demand. Relative to other advanced glazings, the savings are significantly lower, ranging from 0 to 1.2 kW h/ft 2 . Regional DBEC energy cost savings versus high performance static windows are presented to identify early potential market entries based on energy savings. Lastly, the impacts of widespread deployment of high-efficiency LED lighting on DBEC energy savings potentials are also presented.

14 SOLAR ENERGY↗

Solar plus: A review of the end-user economics of solar PV integration with storage and load control in residential buildings

Batteries and load control devices can increase the value of distributed solar photovoltaics (PV) from multiple perspectives - end-user, utility, and social. This review paper summarizes the end-user economics of battery and load control technologies that increase the value of PV by controlling and temporally shifting PV output, an approach referred to as 'solar plus.' Solar plus can increase on-site PV use. The literature shows that these values justify the incremental costs of solar plus devices for a wide variety of technologies, geographies, and customer load profiles, especially for customers in three rate structure contexts: where PV is sold to the grid at a lower value than the customer's retail rate, in time-of-use rates where peak periods do not coincide with PV output, and in demand charge rates where load peaks do not coincide with PV output. Rate structure and policy reform may be necessary to ensure that increasing solar plus deployment provides both end-user and system-level benefits.

14 SOLAR ENERGY↗

Field measurement of moisture-buffering model inputs for residential buildings

Moisture adsorption and desorption in building materials impact indoor humidity. This effect should be included in building-energy simulations, particularly when humidity is being investigated or controlled. Several models can calculate this moisture-buffering effect, but accurate ones require model inputs that are not always known to the user of the building-energy simulation. This research developed an empirical method to extract whole-house model inputs for the effective moisture penetration depth (EMPD) model. The experimental approach was to subject the materials in the house to a square-wave relative-humidity profile, measure all of the moisture-transfer terms (e.g., infiltration, air-conditioner condensate), and calculate the only unmeasured term—the moisture sorption into the materials. We validated this method with laboratory measurements, which we used to measure the EMPD model inputs of two houses. After deriving these inputs, we measured the humidity of the same houses during tests with realistic latent and sensible loads and demonstrated the accuracy of this approach. Furthermore, these results show that the EMPD model, when given reasonable inputs, is an accurate moisture-buffering model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effective moisture penetration depth model for residential buildings: Sensitivity analysis and guidance on model inputs

Moisture buffering of building materials has a significant impact on the building's indoor humidity, and building energy simulations need to model this buffering to accurately predict the humidity. Researchers requiring a simple moisture-buffering approach typically rely on the effective-capacitance model, which has been shown to be a poor predictor of actual indoor humidity. This paper describes an alternative two-layer effective moisture penetration depth (EMPD) model and its inputs. While this model has been used previously, there is a need to understand the sensitivity of this model to uncertain inputs. In this paper, we use the moisture-adsorbent materials exposed to the interior air: drywall, wood, and carpet. We use a global sensitivity analysis to determine which inputs are most influential and how the model's prediction capability degrades due to uncertainty in these inputs. We then compare the model's humidity prediction with measured data from five houses, which shows that this model, and a set of simple inputs, can give reasonable prediction of the indoor humidity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗