Residential Water Heating Demand Side Management (DSM) - South Africa

The electricity crisis in South Africa has deteriorated significantly, with the country experiencing frequent and prolonged rolling blackouts. These outages have severe economic repercussions, leading to decreased growth and productivity. Demand Side Management (DSM), particularly focusing on electric water heaters due to their significant energy consumption and peak demand contribution, is identified as a key strategy. The study aims to assess opportunities for DSM programs targeting water heating to reduce energy consumption and peak demand. It entails developing a bottom-up simulation model to establish a baseline scenario of water heating electricity load demand in 2023 and 2033, identifying technologies for energy reduction, estimating the impacts of a selected number of measures and providing recommendations to inform policy makers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

Piston Bowl Geometry Effects on Gasoline Compression Ignition in a Heavy-Duty Diesel Engine

A design optimization campaign was conducted to search for improved combustion profiles that enhance gasoline compression ignition in a heavy-duty diesel engine with a geometric compression ratio of 17.3. A large-scale design of experiments approach was used for the optimization, employing three-dimensional computational fluid dynamics simulations. The main parameters explored include geometric features, injector specifications, and swirl motion. Both stepped-lip and re-entrant bowls were included in order to assess their respective performance implications. A total of 256 design candidates were prepared using the software package CAESES for automated and simultaneous geometry generation and combustion recipe perturbation. The design optimization was conducted for three engine loads representing light to medium load conditions. The design candidates were evaluated for fuel efficiency, emissions, fuel-air mixing, and global combustion behavior. Simulation results showed that the optimum designs were all stepped-lip bowls, due to improvements in fuel-air mixing, as well as reduced heat loss and emissions formation. Improvements in indicated specific fuel consumption of up to 3.2% were achieved while meeting engine-out NOx emission targets of 1-1.5 g/kW center dot h. Re-entrant bowls performed worse compared to the baseline design, and significant performance variations occurred across the load points. Specifically, the re-entrant bowls were on par with the stepped-lip bowls under light load conditions, but significant deteriorations occurred under higher load conditions. As a final task, selected optimized designs were then evaluated under full-load conditions.

CFD↗

Assessment of Electrode Contamination Mitigation at 0.5 MA Scale

The Z Machine at Sandia National Laboratories uses current pulses with peaks up to 27 MA to drive target implosions and generate high energy density conditions of interest for stockpile stewardship programs pertinent to the NNSA program portfolio . Physical processes in the region near the Z Machine target create electrode plasmas which seed parasitic current loss that reduce the performance and output of a Z experiment. Electrode surface contaminants (hydrogen, water, hydrocarbons) are thought to be the primary constituent of electrode plasmas which contribute to loss mechanisms. The Sandia team explore d in situ heating and plasma discharge techniques by integrating requisite infrastructure into Sandia's Mykonos LTD accelerator, addressing potential impacts to accelerator operation, and reporting on the impact of these techniques on electrode plasma formation and shot performance. The in situ discharge cleaning utilizes the electrodes of the accelerator to excite an argon-oxygen plasma to sputter and chemically react contaminants from electrode surfaces. Insulating breaks are required to isolate the plasma in electrode regions where loss processes are most likely to occur. The shots on Mykonos validate that these breaks do not perturb experiment performance, reducing the uncertainty on the largest unknown about the in situ cleaning system. Preliminary observations with electrical and optical diagnostics suggest that electrode plasma formation is delayed, and overall inventory has been substantively reduced. In situ heating embeds cartridge heaters into accelerator electrodes and employs a thermal bakeout to rapidly desorb contaminants from electrode surfaces. For the first time, additively manufactured (AM) electrode assemblies were used on a low impedance accelerator to integrate cooling channels and manage thermal gradients. Challenges with poor supplier fabrication to specifications, load alignment, thermal expansion and hardware movement and warpage appears to have introduced large variability in observed loss, though, preventing strong assertions of loss reduction via in situ heating. At this time, an in situ discharge cleaning process offers the lowest risk path to reduce electrode contaminant inventories on Z, though we recommend continuing to develop both approaches. Additional engineering and testing are required to improve the implementation of both systems. .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Reduced-Order CFD Modeling to Support Waste Loading Optimization in Hanford WTP Vitrification

The U.S. DOE Hanford Site stores over 56 million gallons of radioactive liquid tank waste that must be treated and immobilized for long-term disposal The Waste Treatment and Immobilization Plant (WTP) will vitrify this waste by feeding it into Joule-heated melters, where it is incorporated into a stable borosilicate glass Computational fluid dynamics (CFD) simulations of glass melters can provide insight into the maximum achievable waste loading under varying melter operating conditions Fully resolved VOF multiphase simulations were used as the reference model to capture bubble-driven convection in the melter, including bubble formation, rise behavior, and induced glass melt circulation Effective bubble column diameter and rise velocity were extracted from the resolved simulations, compared with empirical correlations, and refit across relevant viscosity and gas flow rate conditions Explicit gas–liquid interface tracking was replaced with a single-phase momentum source term model, enabling faster steady-state CFD simulations while preserving the dominant hydrodynamic effects of bubbling New empirical correlations were developed for effective bubble column diameter and bubble rise velocity by fitting resolved simulation data across expected melter viscosity and gas flow rate ranges, providing improved inputs for the momentum source term model compared with existing literature correlations The momentum source term model reduced fluid-domain mesh size by 89% and achieved an 8.4× computational speedup relative to resolved bubbling simulations The validated momentum source term approach enables prediction of process-relevant heat transfer behavior in the integrated melter model, including heat transfer from the molten glass to the cold cap, plenum, refractory walls, and surrounding structural regions under varying melter operating conditions

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiphysics Modeling of Microreactors with NEAMS codes, and Validation Based on KRUSTY Reactivity Insertion

The NEAMS Multiphysics Applications team continues to assess code usability and functionality for microreactor design and safety analyses, while demonstrating that NEAMS tools capture both steady-state and transient behavior across distinct microreactor concepts. In FY2025, the team advanced full-core, high-fidelity, multiphysics models that solve more complex problems and strengthen verification/validation for several microreactor systems: heat-pipe microreactor (HPMR), gas-cooled microreactor (GCMR), and the KRUSTY experiment. These models employ the MOOSE MultiApp/Transfers architecture with Griffin for neutronics, BISON for heat conduction/thermomechanics, Sockeye for heat pipes, SAM/THM for coolant channels and loops, and SWIFT for hydride behavior, with meshes generated via the MOOSE Reactor Module. The graphite models available in the Grizzly code were also investigated for future analyses. For the HPMR, a Na-HPMR variant was constructed to align with recently validated heat-pipe experiments and Sockeye’s LCVF capability, enabling mechanistic heat-pipe transients and startup modeling. The Na-HPMR will serve as the primary model for HPMR investigations in upcoming tasks. The load-following and single heat-pipe failure scenarios (Griffin/BISON/Sockeye), which were previously modeled for the K-HPMR, were replicated for the Na-HPMR, showing strong negative temperature feedback and highly localized thermal effects, respectively, while the startup case captured vapor-front progression and heat-removal activation. Solid mechanics was added to the previously built K-HPMR full-core model in BISON, showing minimal impact on steady-state reactivity yet enabling stress-field predictions that prepare the path for full-core TRISO performance analyses. For the GCMR, automated steady-state and four transient scenarios were executed using Griffin/BISON/SAM/SWIFT. Results confirm robust inherent safety: power collapses promptly in loss-of-cooling events, the inlet-temperature drop settles to a new equilibrium, and a single-channel blockage yields only a ~30 K local fuel-temperature rise with <0.4% power decrease. SWIFT-predicted hydrogen redistribution affects reactivity during both steady-state and transient conditions, underscoring its importance. A Brayton-cycle balance of plant (BOP) model in SAM/THM demonstrated stable startup behavior, and xenon-driven reactivity during load following was analyzed. To improve TRISO-compact temperature fidelity, a fast multiscale Heat Source Decomposition (HSD) treatment was implemented. Against heterogeneous benchmarks, HSD reduces underprediction of kernel temperatures and lowers predicted peak powers in reactivity-insertion transients compared to previous homogenized models. KRUSTY warm-critical validation progressed from FY2024 baselines: the 15Ȼ insertion shows excellent agreement in peak power (~2% high) and temperature trends, and the 30Ȼ case was automated via a feedback controller that maintained power near 3 kW for ~150 s with close agreement to data. The successful modeling of the warm critical tests has laid a strong foundation for simulating more complex nuclear system tests in the years ahead. Throughout FY2025, developer feedback was provided (e.g., MOOSE batch mesh generation, distributed pre-split meshes, Griffin sweeper on displaced meshes), several new models were contributed to the Virtual Test Bed, and an OECD-NEA WPRS multiphysics benchmark based on the HPMR was initiated to enable broader cross-comparison and best-practice development with the nuclear community at large.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Improving solar panel durability through novel panel designs and advanced manufacturing equipment

Work in the project was spread across 4 main themes:1) Improved Understanding of Why Cracks Form and Cause Degradation in Solar Cells: We developed a finite element model which correlated well with experimental determined deflection vs load profiles and which predicted stress profiles vs load level and temperature. These profiles helped to guide brace designs and showed the high stress levels seen in the silicon near the interconnect wire locations as the temperature is cooled below -30C, likely forming "invisible" microcracks. Experiments showed how for polymer backsheet modules, a brief exposure to such low temperatures made modules extremely sensitive to propagation of these microcracks at relatively low load levels, and how thicker and softer encapsulant helped to reduce this crack sensitivity. We showed for some modules that most cracks that are seen under loading had their origin at short, hard to see, V-cracks from soldering damage, and how the shunting from cells with high densities of cracks reduces energy delivery more than Pmax. 2) Improved Durability Testing Methods With Respect to Cracked Cells: We lobbied the PV community throughout the project that IEC 61215 was insufficient to probe the sensitivity of module Pmax degradation due to cracks in that in did not have a test leg that included a crack creation step (static loading) followed by a crack opening step (cyclic loading and/or thermal cycling). We published extensively on how pre- existing cracks opened up with cyclic loading. The new IEC TS 63209-1 ED1 test sequence now include our recommendations, and this should lead to improved module designs and reduced risk for investors. We also published recommendations for a new "Cold Climate Test" sequence to probe the sensitivity of modules to degradation from short microcracks formed when modules see temperatures below -30C followed by front side loading. We participated in several USTAG meetings related to cracked cells, EL testing, and mechanical load testing and provided input to the group to improve new standards under consideration. We also showed how the act of performing an EL test can affect the test results due to heating from the injected current. 3) New Module Designs and Related Manufacturing Methods & Equipment: We demonstrated reduced crack sensitivity on encapsulated cell coupons the benefits of building protective compressive stress into the cells by laminating them in a bent state and then allowing the coupon to flatten out after lamination. Our attempts to scale this to the module level with a more manufacturable sequence did not demonstrate the same positive effects, but we hope that others will follow up with other variations on this bent lamination or bent cooling concept to make more durable modules. 4) New Module Mounting Designs: We explored a range of bracing concepts which pressed on the backsheet to slightly bow the glass outward and place cells in a state of protective compressive stress and to reduce the deflection under front side loads. These successfully reduced cell cracking and crack opening, but high static loads permanently deformed cost-effective braces, after which they provided little benefit. We settled on an elegant & effective solution – the RailPad, where lightweight bracing elements are placed between the mounting rail(s) and the backsheet, and the existing strength of the rails is used to prevent module deflection under load. New construction and retrofit designs were made, and test sites were implemented in FL and MA. We applied for RailPad patent protection.

14 SOLAR ENERGY↗

Demonstration of Super-X divertor exhaust control for transient heat load management in compact fusion reactors

Nuclear fusion could offer clean, abundant energy. However, managing the power exhausted from the core fusion plasma towards the reactor wall remains a major challenge. This is compounded in emerging compact reactor designs promising more cost-effective pathways towards commercial fusion energy. Alternative Divertor Configurations (ADCs) are a potential solution. In this work, we demonstrate exhaust control in ADCs, employing a novel method to diagnose the neutral gas buffer, which shields the target. Our work on the Mega Ampere Spherical Tokamak Upgrade shows that ADCs tackle key risks and uncertainties for fusion energy. Their highly reduced sensitivity to perturbations enables active exhaust control in otherwise unfeasible situations and facilitates an increased passive absorption of transients, which would otherwise damage the divertor. We observe a strong decoupling of each divertor from other reactor regions, enabling near-independent control of the divertors and core plasma. Our work showcases the real-world benefits of ADCs for effective heat load management in fusion power reactors.

Imaging techniques↗

Cascaded hard X-ray self-seeded free-electron laser at megahertz repetition rate

High-resolution X-ray spectroscopy in the sub-nanosecond to femtosecond time range requires ultrashort X-ray pulses and a spectral X-ray flux considerably larger than that presently available. X-ray free-electron laser (XFEL) radiation from hard X-ray self-seeding (HXRSS) setups has been demonstrated in the past and offers the necessary peak flux properties. So far, these systems could not provide high repetition rates enabling a high average flux. We report the results for a cascaded HXRSS system installed at the European XFEL, currently the only operating high-repetition-rate hard X-ray XFEL facility worldwide. A high repetition rate, combined with HXRSS, allows the generation of millijoule-level pulses in the photon energy range of 6–14 keV with a bandwidth of around 1 eV (corresponding to about 1 mJ eV –1 peak spectral density) at the rate of ten trains per second, each train including hundreds of pulses arriving at a megahertz repetition rate. At 2.25 MHz repetition rate and photon energies in the 6–7 keV range, we observed and characterized the heat-load effects on the HXRSS crystals, substantially altering the spectra of subsequent X-ray pulses. We demonstrated that our cascaded self-seeding scheme reduces this detrimental effect to below the detection level. This opens up exciting new possibilities in a wide range of scientific fields employing ultrafast X-ray spectroscopy, scattering and imaging techniques.

47 OTHER INSTRUMENTATION↗

Extending the Air and Moisture Leakage Calculator to add Residential Buildings and Additional Commercial Buildings

The DOE Windows and Building Envelope Research and Development Roadmap for Emerging Technologies shows that in 2010, infiltration was responsible for 4 quads of space conditioning primary energy use in the residential and commercial sectors. The relative contribution of air leakage in building heating and cooling load is increasing with improvement in the thermal resistance of building envelopes. Advanced air barrier technologies and construction practices have been developed to reduce air leakage in buildings. However, limited information on the impact of air barrier technologies on energy consumption and the durability of buildings has hindered their adoption. In the past Oak Ridge National Laboratory (ORNL), the National Institute of Standards and Technology (NIST), Air Barrier Association of America (ABBA), and U.S.-China Clean Energy Research Center for Building Energy Efficiency (CERC-BEE) collaborated to develop an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in air tightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. In this study, the calculator is expanded further by adding data for two additional commercial buildings (strip mall and primary school) and a residential building. The team investigated the impact of airtightness on energy consumption and moisture transfer of the added buildings. The study includes the analysis of air tightness in 52 major cities in the U.S. and 5 cities in Canada.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapidly ramp cryogenic air separation unit without loss of O2 product purity—application for low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for low-carbon, fossil-fuel power plant capable of rapid ramping. Therefore, a cryogenic air separation unit (ASU) as part of low-carbon, fossil-fuel power plant should be capable of rapid ramping. However, highly integrated and nonlinear processes of the ASU would significantly restrict this rapid ramping. To overcome this fundamental issue, we study the basic dynamic process of a state-of-the-art double-column ASU. A flow-driven dynamic model was established in Aspen Plus Dynamics, assuming perfect flow controls, to capture the basic dynamics of ramping ASU. We find the vapor-liquid counter-current flow structure in the low-pressure column is critical to the air separation when rapidly ramping the ASU. This flow structure is established based on a complicated heat integration process. It is simplified as an apparent counter-current heat transfer process in this work, which greatly reduces the complexity for studying the dynamics of ASU. For keeping this basic flow structure, the heat integration is maintained as its heat duty follows the ASU load, through several basic feed-forward and feed-back controllers on the critical stream flowrates. Moreover, we find a fundamental issue of mismatched dynamics in the low-pressure column, resulting in a significant loss of O2 product purity when rapidly ramping down the ASU and an obvious fluctuation of O2 product purity. Based on these explorations, we propose a basic control method for rapidly ramping the ASU without loss of O2 product purity. Results show the ASU basic dynamic process successfully ramps at a rate up to 10%/min (40-100% load) while maintaining the O2 product purity within 95.2-95.6 mol%.

Cheng, Mao↗

Assessing and Reducing Plug and Process Loads in Retail Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Assessing and Reducing Plug and Process Loads in Office Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗