Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The Correlation Radiometer - A New Application in MM-Wave Total Power Radiometry

We describe the design and performance of a 180 GHz correlation radiometer suitable for remote sensing. The radiometer provides continuous comparisons between a the observed signal and a reference load to provide stable radiometric baselines. The radiometer was assembled and tested using parts from the GeoSTAR-II instrument and is fully compatible with operation in a synthetic aperture radiometer or as a standalone technology for use in microwave sounding and imaging. This new radiometer was tested over several days easily demonstrating the required 6 hour stability requirement for observations of mean brightness temperature for a geostationary instrument.

Monolithic Microwave Integrated Circuit (MMIC)↗

Vortex Radiometry: Enabling Frequency Agile Communications

Exponential proliferation of UAVs and CubeSats puts NASA's high priority communication systems at risk. UAVs and CubeSats are easy to acquire, modify and build, making it extremely likely that some will be used in unauthorized ways. While these systems provide several benefits to society, their increased use also increases the probability of unintentional signal interference, and even deliberate jamming of NASA's communication systems.This paper presents an algorithm to determine 1) when an interference induced fade will occur, 2) how long the fade will persist for and 3) how intense the fade will be. The algorithm requires data collected from Vortex Radiometers (VRs), which probe the RF environment using annular antenna beam patterns. A set of numerical simulations show that a multi-beam VR system can instruct a cognitive antenna to switch between Ka- and X-Band communications, in order to avert interference from small diameter noise sources. Analysis of the simulation results indicate that practical VR systems will require several concentric annular beam patterns, in order to mitigate fades from noise sources of various sizes. The paper concludes by identifying technology challenges that need to be overcome to achieve these capabilities.

Orbital Angular Momentum↗

Mitigating Interference from Urban Air Mobility Vehicles on Satellite Communication Links by Using Vortex Radiometry

Vortex radiometers (VR) establish an early warning system for communication systems by generating concentric annular beam patterns around the active link. Received power peaks are monitored as interfering signals traverse overhead, allowing the VR to estimate source velocity. From this information the VR determines 1) when a fade will occur, 2) how long the fade will persist for and 3) how intense the fade will be. This paper demonstrates how VRs can be used to increase the resilience of communication systems used in urban air mobility applications.

vortex radiometry↗

Atmospheric Remote Sensing by Microwave Radiometry

The Earth's atmosphere is a puzzle and a concern. Its unpredictable weather has always been a force to be recokoned with, but until recent times, our trust was implicit in the robustness of the atmospheric system as the foundation of our biosphere. Now we are not so sure.

microwave↗

High-accuracy X-ray detector calibration based on cryogenic radiometry

Cryogenic electrical substitution radiometers (ESRs) are absolute thermal detectors, based on the equivalence of electrical power and radiant power. Their core piece is a cavity absorber, which is typically made of copper to achieve a short response time. At higher photon energies, the use of copper prevents the operation of ESRs due to increasing transmittance. A new absorber design for hard X-rays has been developed at the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II. The Monte Carlo simulation code Geant4 was applied to optimize its absorptance for photon energies of up to 60 keV. The measurement of the radiant power of monochromatized synchrotron radiation was achieved with relative standard uncertainties of less than 0.2 %, covering the entire photon energy range of three beamlines from 50 eV to 60 keV. Monochromatized synchrotron radiation of high spectral purity is used to calibrate silicon photodiodes against the ESR for photon energies up to 60 keV with relative standard uncertainties below 0.3 %. For some silicon photodiodes, the photocurrent is not linear with the incident radiant power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Cloning for Absolute Radiometry

In the quantum regime information can be copied with only a finite fidelity. This fidelity gradually increases to 1 as the system becomes classical. In this Letter we show how this fact can be used to directly measure the amount of radiated power. We demonstrate how these principles can be used to build a practical primary standard.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photothermal Infrared Radiometry in Experimental Studies of the Pyroelectric Properties of Bulk Materials

A simple and efficient method for determining the pyrolelectric coefficients of ferroelectric and pyroelectric bulk materials by taking into account the heat exchange of a sample with the environment is proposed on the basis of the radiometric registration of the variation dynamics of the temperature of the surface when it is exposed to laser radiation in the form of a temporal step.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Far infrared thermal detectors for laser radiometry using a carbon nanotube array

We present a description of a 1.5 mm long, vertically aligned carbon nanotube array (VANTA) on a thermopile and separately on a pyroelectric detector. Three VANTA samples, having average lengths of 40 {mu}m, 150 {mu}m, and 1.5 mm were evaluated with respect to reflectance at a laser wavelength of 394 {mu}m(760 GHz), and we found that the reflectance decreases substantially with increasing tube length, ranging from 0.38 to 0.23 to 0.01, respectively. The responsivity of the thermopile by electrical heating (98.4 mA/W) was equal to that by optical heating (98.0 mA/W) within the uncertainty of the measurement. We analyzed the frequency response and temporal response and found a thermal decay period of 500 ms, which is consistent with the specific heat of comparable VANTAs in the literature. The extremely low (0.01) reflectance of the 1.5 mm VANTAs and the fact that the array is readily transferable to the detector's surface is, to our knowledge, unprecedented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARM Shortwave Spectral Radiometry Strategy Review Report

A meeting of experts in shortwave (SW) spectral measurements was held in February 2019 to discuss the current state of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrumentation and the potential scientific impact of these measurements. Instrument mentors and users reported significant progress in hyperspectral measurement quality, with good-quality data sets now possible at several field campaigns and fixed sites. Ongoing filter-based measurement improvements, including addition of the 1.6-micron channel to the multifilter rotating shadowband radiometer (MFRSR) and lunar tracking mode of the Cimel sun photometers, were also lauded as exciting developments to improve retrievals of aerosol radiative properties and size distributions.

54 ENVIRONMENTAL SCIENCES↗

ARM Shortwave Spectral Radiometry Strategy Review Report

A meeting of experts in shortwave (SW) spectral measurements was held in February 2019 to discuss the current state of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrumentation and the potential scientific impact of these measurements. Instrument mentors and users reported significant progress in hyperspectral measurement quality, with good-quality data sets now possible at several field campaigns and fixed sites. Ongoing filter-based measurement improvements, including addition of the 1.6-micron channel to the multifilter rotating shadowband radiometer (MFRSR) and lunar tracking mode of the Cimel sun photometers, were also lauded as exciting developments to improve retrievals of aerosol radiative properties and size distributions.

54 ENVIRONMENTAL SCIENCES↗

Thin ice clouds in the Arctic: cloud optical depth and particle size retrieved from ground-based thermal infrared radiometry

Multiband downwelling thermal measurements of zenith sky radiance, along with cloud boundary heights, were used in a retrieval algorithm to estimate cloud optical depth and effective particle diameter of thin ice clouds in the Canadian High Arctic. Ground-based thermal infrared (IR) radiances for 150 semitransparent ice clouds cases were acquired at the Polar Environment Atmospheric Research Laboratory (PEARL) in Eureka, Nunavut, Canada (80° N, 86° W). We analyzed and quantified the sensitivity of downwelling thermal radiance to several cloud parameters including optical depth, effective particle diameter and shape, water vapor content, cloud geometric thickness and cloud base altitude. A lookup table retrieval method was used to successfully extract, through an optimal estimation method, cloud optical depth up to a maximum value of 2.6 and to separate thin ice clouds into two classes: (1) TIC1 clouds characterized by small crystals (effective particle diameter ≤ 30 µm), and (2) TIC2 clouds characterized by large ice crystals (effective particle diameter > 30 µm). The retrieval technique was validated using data from the Arctic High Spectral Resolution Lidar (AHSRL) and Millimeter Wave Cloud Radar (MMCR). Inversions were performed over three polar winters and results showed a significant correlation ( R 2 = 0.95) for cloud optical depth retrievals and an overall accuracy of 83 % for the classification of TIC1 and TIC2 clouds. A partial validation relative to an algorithm based on high spectral resolution downwelling IR radiance measurements between 8 and 21µm was also performed. It confirms the robustness of the optical depth retrieval and the fact that the broadband thermal radiometer retrieval was sensitive to small particle (TIC1) sizes.

54 ENVIRONMENTAL SCIENCES↗