Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radio frequency techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design development and manufacture of a breadboard radio frequency mass gauging system. Volume 1: Phase B final report

The applicability of the RF Mode Counting technique for gauging liquid oxygen and liquid hydrogen under all attitude conditions was demonstrated using a vacuum jacketed test tank mounted on a remotely controlled gimbaling mechanism. In addition, the technique was successfully tested using liquid oxygen in a large NASA test tank as the tank was filled and emptied. To further substantiate the capabilities of the RF Mode Counting technique as applied to applications involving zero gravity conditions, a test system using benzene as a test fluid was flight tested in a KC-135 test aircraft. This testing involved a number of zero "g" maneuvers with various quantities of the test fluid. A series of tests were also performed to evaluate the relative effects of the presence of capillary liquid retention screens on the RF Gauging technique. These tests involved considerations of system Q reductions, RF leakage through retention screens, and surface wetting effects.

Source record↗

Water vapor as an error source in microwave geodetic systems: Background and survey of calibration techniques

Water vapor as an error source in radio interferometry systems is briefly examined. At microwave frequencies, the delay imposed by tropospheric water vapor becomes a limiting error source for high accuracy geodetic systems. The mapping of tropospheric induced errors into 'solved-for' parameters depends upon baseline length and observing strategy. Simulation analysis (and experience) indicates that in some cases, errors in estimating tropospheric delay can be magnified in their effect on baseline components. The various techniques by which tropospheric water can be estimated or measured are surveyed with particular consideration to their possible use as a calibration technique in support to very long baseline interferometry experiments. The method of remote sensing using a microwave radiometer seems to be the most effective way to provide an accurate estimate of water vapor delay.

Claflin, E. S.↗

Low Power Silicon Germanium Electronics for Microwave Radiometers

Space-based radiometric observations of key hydrological parameters (e.g., soil moisture) at the spatial and temporal scales required in the post-2002 era face significant technological challenges. These measurements are based on relatively low frequency thermal microwave emission (at 1.4 GHz for soil moisture and salinity, 10 GHz and up for precipitation, and 19 and 37 GHz for snow). The long wavelengths at these frequencies coupled with the high spatial and radiometric resolutions required by the various global hydrology communities necessitate the use of very large apertures (e.g., greater than 20 m at 1.4 GHz) and highly integrated stable RF electronics on orbit. Radio-interferometric techniques such as Synthetic Thinned Array Radiometry (STAR), using silicon germanium (SiGe) low power radio frequency integrated circuits (RFIC), is one of the most promising technologies to enable very large non-rotating apertures in space. STAR instruments are composed of arrays of small antenna/receiving elements that are arranged so that the collecting area is smaller than an equivalent real aperture system, allowing very high packing densities for launch. A 20 meter aperture at L-band, for example, will require greater than 1000 of these receiving elements. SiGe RFIC's reduce power consumption enough to make an array like this possible in the power-limited environment of space flight. An overview of the state-of-the-art will be given, and current work in the area of SiGe radiometer development for soil moisture remote sensing will be discussed.

Doiron, Terence A.↗

Reduction and analysis of data collected during the electromagnetic tornado experiment

Techniques for data processing and analysis are described to support tornado detection by analysis of radio frequency interference in various frequency bands, and sea state determination from short pulse radar measurements. Activities include: strip chart recording of tornado data; the development and implementation of computer programs for digitalization and analysis of the data; data reduction techniques for short pulse radar data, and the simulation of radar returns from the sea surface by computer models.

Davisson, L. D.↗

Real-time closed-loop simulation and upset evaluation of control systems in harsh electromagnetic environments

Digital control systems for applications such as aircraft avionics and multibody systems must maintain adequate control integrity in adverse as well as nominal operating conditions. For example, control systems for advanced aircraft, and especially those with relaxed static stability, will be critical to flight and will, therefore, have very high reliability specifications which must be met regardless of operating conditions. In addition, multibody systems such as robotic manipulators performing critical functions must have control systems capable of robust performance in any operating environment in order to complete the assigned task reliably. Severe operating conditions for electronic control systems can result from electromagnetic disturbances caused by lightning, high energy radio frequency (HERF) transmitters, and nuclear electromagnetic pulses (NEMP). For this reason, techniques must be developed to evaluate the integrity of the control system in adverse operating environments. The most difficult and illusive perturbations to computer-based control systems that can be caused by an electromagnetic environment (EME) are functional error modes that involve no component damage. These error modes are collectively known as upset, can occur simultaneously in all of the channels of a redundant control system, and are software dependent. Upset studies performed to date have not addressed the assessment of fault tolerant systems and do not involve the evaluation of a control system operating in a closed-loop with the plant. A methodology for performing a real-time simulation of the closed-loop dynamics of a fault tolerant control system with a simulated plant operating in an electromagnetically harsh environment is presented. In particular, considerations for performing upset tests on the controller are discussed. Some of these considerations are the generation and coupling of analog signals representative of electromagnetic disturbances to a control system under test, analog data acquisition, and digital data acquisition from fault tolerant systems. In addition, a case study of an upset test methodology for a fault tolerant electromagnetic aircraft engine control system is presented.

Belcastro, Celeste M.↗

Fault Tolerance in ZigBee Wireless Sensor Networks

Wireless sensor networks (WSN) based on the IEEE 802.15.4 Personal Area Network standard are finding increasing use in the home automation and emerging smart energy markets. The network and application layers, based on the ZigBee 2007 PRO Standard, provide a convenient framework for component-based software that supports customer solutions from multiple vendors. This technology is supported by System-on-a-Chip solutions, resulting in extremely small and low-power nodes. The Wireless Connections in Space Project addresses the aerospace flight domain for both flight-critical and non-critical avionics. WSNs provide the inherent fault tolerance required for aerospace applications utilizing such technology. The team from Ames Research Center has developed techniques for assessing the fault tolerance of ZigBee WSNs challenged by radio frequency (RF) interference or WSN node failure.

Alena, Richard↗

Microwave Treatment for Cardiac Arrhythmias

NASA seeks to transfer the NASA developed microwave ablation technology, designed for the treatment of ventricular tachycardia (irregular heart beat), to industry. After a heart attack, many cells surrounding the resulting scar continue to live but are abnormal electrically; they may conduct impulses unusually slowly or fire when they would typically be silent. These diseased areas might disturb smooth signaling by forming a reentrant circuit in the muscle. The objective of microwave ablation is to heat and kill these diseased cells to restore appropriate electrical activity in the heart. This technology is a method and apparatus that provides for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In comparison with other methods that involve direct-current pulses or radio frequencies below 1 GHz, this method may prove more effective in treating ventricular tachycardia. This is because the present method provides for greater control of the location, cross-sectional area, and depth of a lesion via selection of the location and design of the antenna and the choice of microwave power and frequency.

Hernandez-Moya, Sonia↗

Finite element modeling of electropolishing of radio frequency dipole Nb crab cavity in hydrofluoric-sulfuric acid electrolyte

The superior performance of niobium superconducting radio frequency (SRF) cavities is achieved through meticulous surface treatment, notably via chemical electropolishing, ensuring exceptionally smooth surfaces. While this technique has been extensively employed for cylindrically symmetric structures, addressing more intricate geometries poses significant challenges in achieving uniform polishing and controlled material removal, especially when moving away from retractable cathodes. This presents a multifaceted electrochemical, thermal, and fluid dynamics conundrum. A prime example is the 197 MHz radio frequency dipole (RFD) crabbing cavity proposed for the Electron Ion Collider (EIC) project, exemplifying such complex structures. Our groundbreaking work integrates the localized oxide thickness variation, considering its impact on current distribution and Joule heating, within the framework of multi-physics modeling using the COMSOL® simulation suite. This approach was applied to a comprehensive model of the RFD cavity, allowing us to investigate optimal external cooling water flow conditions necessary for achieving desirable outcomes. In conclusion, this illustrates the increasing utility of such multi-physics codes to greatly aid in designing solutions to challenging processing requirements for increasingly complex accelerator cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-of-flight modulated intensity small-angle neutron scattering measurement of the self-diffusion constant of water

We report that the modulated intensity by zero effort small-angle neutron scattering (MI-SANS) technique is used to measure scattering with a high energy resolution on samples normally ill-suited for neutron resonance spin echo. The self-diffusion constant of water is measured over a q–t range of 0.01–0.2 Å -1 and 70–500 ps. In addition to demonstrating the methodology of using time-of-flight MI-SANS instruments to observe diffusion in liquids, the results support previous measurements on water performed with different methods. This polarized neutron technique simultaneously measures the intermediate scattering function for a wide range of time and length scales. Two radio frequency flippers were used in a spin-echo setup with a 100 kHz frequency difference in order to create a high-resolution time measurement. The results are compared with self-diffusion measurements made by other techniques and the general applicability of MI-SANS at a pulsed source is assessed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

Towards fast and accurate predictions of radio frequency power deposition and current profile via data-driven modelling: applications to lower hybrid current drive

Three machine learning techniques (multilayer perceptron, random forest and Gaussian process) provide fast surrogate models for lower hybrid current drive (LHCD) simulations. A single GENRAY/CQL3D simulation without radial diffusion of fast electrons requires several minutes of wall-clock time to complete, which is acceptable for many purposes, but too slow for integrated modelling and real-time control applications. The machine learning models use a database of more than 16 000 GENRAY/CQL3D simulations for training, validation and testing. Latin hypercube sampling methods ensure that the database covers the range of nine input parameters ( $n_{e0}$ , $T_{e0}$ , $I_p$ , $B_t$ , $R_0$ , $n_{\|}$ , $Z_{{\rm eff}}$ , $V_{{\rm loop}}$ and $P_{{\rm LHCD}}$ ) with sufficient density in all regions of parameter space. The surrogate models reduce the inference time from minutes to $\sim$ ms with high accuracy across the input parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method and apparatus for sputtering utilizing an apertured electrode and a pulsed substrate bias

The method and equipment used for sputtering by use of an apertured electrode and a pulsed substrate bias are discussed. The technique combines the advantages of ion plating with the versatility of a radio frequency sputtered source. Electroplating is accomplished by passing a pulsed high voltage direct current to the article being plated during radio frequency sputtering.

Przybyszewski, J. S.↗

A study of universal modulation techniques applied to satellite data collection

A universal modulation and frequency control system for use with data collection platform (DCP) transmitters is examined. The final design discussed can, under software/firmwave control, generate all of the specific digital data modulation formats currently used in the NASA satellite data collection service and can simultaneously synthesize the proper RF carrier frequencies employed. A novel technique for DCP time and frequency control is presented. The emissions of NBS radio station WWV/WWVH are received, detected, and finally decoded in microcomputer software to generate a highly accurate time base for the platform; with the assistance of external hardware, the microcomputer also directs the recalibration of all DCP oscillators to achieve very high frequency accuracies and low drift rates versus temperature, supply voltage, and time. The final programmable DCP design also employs direct microcomputer control of data reduction, formatting, transmitter switching, and system power management.

Source record↗

Niobium to Titanium Electron Beam Welding for SRF Cavities

Titanium and niobium are the main materials used for the fabrication of Superconducting Radio Frequency (SRF) cavities. These two metals are usually joined , using various welding techniques, using a third material in between. This contribution focuses on the development of an innovative electron beam welding technique capable of producing a strong bond between these two different materials. Several samples are produced and tested to assess the mechanical strength at room and cryogenic temperature as well as the composition of the resulting welded joint. Also, the first units of the Single Spoke Resonator type 2 (SSR2) cavities for the Proton Improvement Plan-II (PIP-II [1]) have been fabricated joining directly various grades of titanium to niobium and results gathered through the fabrication will be reported.

43 PARTICLE ACCELERATORS↗

Timing Calibration and Windowing Technique Comparison for Lightning Mapping Arrays

Abstract Since their introduction 22 years ago, lightning mapping arrays (LMA) have played a central role in the investigation of lightning physics. Even in recent years with the proliferation of digital interferometers and the introduction of the LOw Frequency ARray (LOFAR) radio telescope, LMAs still play an important role in lightning science. LMA networks use a simple windowing technique that records the highest pulse in either 80 μs or 10 μs fixed windows in order to apply a time‐of‐arrival location technique. In this work, we develop an LMA‐emulator that uses lightning data recorded by LOFAR to simulate an LMA, and we use it to test three new styles of pulse windowing. We show that they produce very similar results as the more traditional LMA windowing, implying that LMA lightning mapping results are relatively independent of windowing technique. In addition, each LMA station has its GPS‐conditioned clock. While the timing accuracy of GPS receivers has improved significantly over the years, they still significantly limit the timing measurements of the LMA. Recently, new time‐of‐arrival techniques have been introduced that can be used to self‐calibrate systematic offsets between different receiving stations. Applying this calibration technique to a set of data with 32 ns uncertainty, observed by the Colorado LMA, improves the timing uncertainty to 19 ns. This technique is not limited to LMAs and could be used to help calibrate future multi‐station lightning interferometers.

Hare, Brian M.↗