Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

An infrared/optical investigation of 100 micron 'cirrus'

IRAS Skyflux images, in conjunction with ESO/SRC photographic plates, are presently used to study a sample of 151 compact cyrrus sources. IR colors entail at least two dust components; a simple two-temperature dust model yields a mean physical temperature of 22.5 + or - 0.3 K for the warm dust, and 173 + or - 8 K for the hot dust, which constitutes 15-42 percent of total IR luminosity. A variable proportion of cold dust may contribute significantly to the optical brightness in two isolated cloud complexes.

Paley, Elizabeth S.↗

Photometric calibration of NGS/POSS and ESO/SRC plates using the NOAO PDS measuring engine. I - Stellar photometry

The PDS/Monet measuring engine at the National Optical Astronomy Observatory was used to obtain photometry of nearly 10,000 stars on the NGS/POSS and 2000 stars on the ESO/SRC Survey glass plates. These measurements have been used to show that global transformation functions exist that allow calibration of stellar photometry from any blue or red plate to equivalent Johnson B and Cousins R photoelectric magnitudes. The four transformation functions appropriate for the POSS O and E and ESO/SRC J and R plates were characterized, and it was found that, within the measurement uncertainties, they vary from plate to plate only by photometric zero-point offsets. A method is described to correct for the zero-point shifts and to obtain calibrated B and R photometry of stellar sources to an average accuracy of 0.3-0.4 mag within the range R between values of 8 and 19.5 for red plates in both surveys, B between values of 9 and 20.5 on POSS blue plates, and B between values of 10 and 20.5 on ESO/SRC blue plates. This calibration procedure makes it possible to obtain rapid photometry of very large numbers of stellar sources.

Cutri, Roc M.↗

Photometric calibration of NGS/POSS and ESO/SRC plates using the NOAO PDS measuring engine. II - Surface photometry

In this paper we present a method to calibrate surface photometry of faint sources measured from direct photographic plates, such as those of the NGS/POSS and ESO/SRC Sky Survey. This calibration procedure does not require scanning sensitometer spots on the plates, but instead uses measurements of the brightness profiles of many faint stars of known brightness to fit a linearized approximation to the characteristic curve. The approximation is valid for only low- to medium-density emulsions, so this technique is appropriate only for relatively faint emission. Comparison between measurements of representative extended sources on the NGS/POSS and CCD images indicates that surface photometry can be obtained from the Sky Survey plates accurate to 0.1-0.3 mag in the range mu(B) between 23 and 27 and mu(R) between 22 and 26 mag/sq arcsec.

Cutri, Roc M.↗

Infrared to x-ray spectral energy distributions of high redshift quasars

We have observed 14 quasars with z greater than 2.8 with the ROSAT-PSPC, and detected 12 of them, including the z=4.11 quasar 0000-263. We present the first x-ray spectrum of a radio quiet quasar with z greater than 3, 1946+768. Its x-ray spectrum is consistent with a power law with spectral index alpha(sub E)=1.8(sup +2.1, sub -1.4) and no evidence for absorption in excess of the galactic column (alpha(sub E)=1.00(sup +0.28, sub -0.32) assuming N(sub H)=N(sub H)(Gal)). A Position Sensitive Proportional Counter (PSPC) hardness ratio is used to constrain the x-ray spectral properties of the quasars for which there were less than 100 photons detected. For the radio quiet quasars, (alpha(sub E)) approximately equals 1.2, if one assumes that there is no absorption in excess of the galactic column. We combine the x-ray data with new ground based optical and near-IR spectrophotometry obtained at the Steward 2.3 m and Multiple Mirror Telescope, and data from the literature. The spectral energy distributions are compared to those of low redshift objects. For the radio quiet quasars with z greater than 2.5, the mean (alpha(sub ox)) is approximately 1.8. This is larger than the mean for quasars with z less than 2.5, but consistent with the expected value for quasars with the high optical luminosities of the objects in this sample. For the radio-loud quasars, (alpha(sub ox)) is approximately 1.4, independent of redshift. This is smaller than the expected value for the optically luminous, high redshift objects in this sample, if they are mostly GHz peaked radio sources and hence comparable to steep-spectrum, compact radio sources at lower redshift. Finally, we compare the spectral energy distributions of two representative objects to the predicted spectrum of a thin accretion disk in the Kerr geometry, and discuss the uncertainties in deriving black hole masses and mass accretion rates.

Bechtold, Jill↗

Atlas of quasar energy distributions

We present an atlas of the spectral energy distributions (SEDs) of normal, nonblazar, quasars over the whole available range (radio to 10 keV X-rays) of the electromagnetic spectrum. The primary (UVSX) sample includes 47 quasars for which the spectral energy distributions include X-ray spectral indices and UV data. Of these, 29 are radio quiet, and 18 are radio loud. The SEDs are presented both in figures and in tabular form, with additional tabular material published on CD-ROM. Previously unpublished observational data for a second set of quasars excluded from the primary sample are also tabulated. The effects of host galaxy starlight contamination and foreground extinction on the UVSX sample are considered and the sample is used to investigate the range of SED properties. Of course, the properties we derive are influenced strongly by the selection effects induced by quasar discovery techniques. We derive the mean energy distribution (MED) for radio-loud and radio-quiet objects and present the bolometric corrections derived from it. We note, however, that the dispersion about this mean is large (approximately one decade for both the infrared and ultraviolet components when the MED is normalized at the near-infrared inflection). At least part of the dispersion in the ultraviolet may be due to time variability, but this is unlikely to be important in the infrared. The existence of such a large dispersion indicates that the MED reflects only some of the properties of quasars and so should be used only with caution.

Elvis, Martin↗

X-ray spectral evolution of high redshift quasars

At z approx. equals 3, the x-ray spectra of radio-loud and radio-quiet quasars are different. High-redshift radio-quiet quasars either have large absorbing columns, N(sub H), and steeper power law spectral indices, alpha(sub epsilon), than low redshift quasars, or no absorption and similar alpha(sub epsilon)'s. In contrast, the radio-loud quasars at high redshift have substantial absorption and similar alpha(sub epsilon)'s to low redshift quasars. Implications for the interpretation of the evolution of the luminosity function of quasars are discussed. If the absorption arises outside the central engine for both radio-loud and radio-quiet quasars, then radio-quiet quasars differ from the radio-loud quasars in that their emitted power law spectrum has evolved with redshift. We argue that this favors models where quasars are numerous and short-lived, rather than rare and long-lived.

Bechtold, Jill↗

IRAS F15307+3252: A hyperluminous infrared galaxy at z = 0.93

A new hyperluminous infrared galaxy in the Infrared Astronomy Satellite (IRAS) Faint Source Catalog is identified at a redshift of 0.93. This object has a bolometric luminosity of approximately 10(exp 13) solar luminosity, a very large ratio of infrared-to-optical luminosity, warm dust emission, a ratio of infrared-to-radio flux densities consistent with other infrared galaxies, and an optical spectrum similar to a Seyfert 2 galaxy. IRAS F15307+3552 shares these characteristics and its radio-to-optical spectral energy distribution with two other infrared galaxies, F10214+4724 and P09104+4109. Discovery of a third object with these properties defines an extreme subclass of ultraluminous galaxies powered primarily by star formation. The systematic method used to find this object begins the process of determining the space density of these most luminous examples of the infrared galaxy phenomenon.

Cutri, Roc M.↗

Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions

OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.

NASA Discipline Space Human Factors↗

Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (< or =5%) patients. Obstructive coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

Non-NASA Center↗

Update on the Wide-field Infrared Survey Explorer (WISE)

The Wide-field Infrared Survey Explorer (WISE), a NASA MIDEX mission, will survey the entire sky in four bands from 3.3 to 23 microns with a sensitivity 1000 times greater than the IRAS survey. The WISE survey will extend the Two Micron All Sky Survey into the thermal infrared and will provide an important catalog for the James Webb Space Telescope. Using 1024(sup 2) HgCdTe and Si:As arrays at 3.3, 4.7, 12 and 23 microns, WISE will find the most luminous galaxies in the universe, the closest stars to the Sun, and it will detect most of the main belt asteroids larger than 3 km. The single WISE instrument consists of a 40 cm diamond-turned aluminum afocal telescope, a two-stage solid hydrogen cryostat, a scan mirror mechanism, and reimaging optics giving 5 resolution (full-width-half-maximum). The use of dichroics and beamsplitters allows four color images of a 47' x47' field of view to be taken every 8.8 seconds, synchronized with the orbital motion to provide total sky coverage with overlap between revolutions. WISE will be placed into a Sun-synchronous polar orbit on a Delta 7320-10 launch vehicle. The WISE survey approach is simple and efficient. The three-axis-stabilized spacecraft rotates at a constant rate while the scan mirror freezes the telescope line of sight during each exposure. WISE has completed its mission Preliminary Design Review and its NASA Confirmation Review, and the project is awaiting confirmation from NASA to proceed to the Critical Design phase. Much of the payload hardware is now complete, and assembly of the payload will occur over the next year. WISE is scheduled to launch in late 2009; the project web site can be found at www.wise.ssl.berkeley.edu.

aster↗

Extending the ICRF into the Infrared: 2MASS - UCAC Astrometry

An external comparison between the infrared 2MASS and the optical UCAC positions was performed, both being on the same system, the ICRS. About 48 million sources in common were identified. Random errors of the 2MASS catalog positions are about 60 to 70 mas per coordinate for the Ks = 4 to 14 range, increasing to about 100 to 150 mas for saturated and very faint stars. Systematic position differences between the 2 catalogs are very small, about 5 to 10 mas as a function of magnitude and color, with somewhat larger errors as a function of right ascension and declination. The extension of the ICRF into the infrared has become a reality.

USNO CCD Astrograph Catalog (UCAC)↗

Near-infrared Variability in the 2MASS Calibration Fields: A Search for Planetary Transit Candidates

The Two Micron All Sky Survey (2MASS) photometric calibration observations cover approximately 6 square degrees on the sky in 35 'calibration fields,' each sampled in nominal photometric conditions between 562 and 3692 times during the 4 years of the 2MASS mission. We compile a catalog of variables from the calibration observations to search for M dwarfs transited by extrasolar planets. We present our methods for measuring periodic and nonperiodic flux variability. From 7554 sources with apparent K(sub s) magnitudes between 5.6 and 16.1, we identify 247 variables, including extragalactic variables and 23 periodic variables. We have discovered three M dwarf eclipsing systems, including two candidates for transiting extrasolar planets.

statistical methods↗

The Wide-Field Infrared Survey Explorer (WISE): Mission Description and Initial On-Orbit Performance

The all sky surveys done by the Palomar Observatory Schmidt, the European Southern Observatory Schmidt, and the United Kingdom Schmidt, the InfraRed Astronomical Satellite and the 2 Micron All Sky Survey have proven to be extremely useful tools for astronomy with value that lasts for decades. The Wide-field Infrared Survey Explorer is mapping the whole sky following its launch on 14 December 2009. WISE began surveying the sky on 14 Jan 2010 and completed its first full coverage of the sky on July 17. The survey will continue to cover the sky a second time until the cryogen is exhausted (anticipated in November 2010). WISE is achieving 5 sigma point source sensitivities better than 0.08, 0.11, 1 and 6 mJy in unconfused regions on the ecliptic in bands centered at wavelengths of 3.4, 4.6, 12 and 22 micrometers. Sensitivity improves toward the ecliptic poles due to denser coverage and lower zodiacal background. The angular resolution is 6.1", 6.4", 6.5" and 12.0" at 3.4, 4.6, 12 and 22 micrometers, and the astrometric precision for high SNR sources is better than 0.15".

Wright, Edward L.↗

WISE Deep and Wide Survey at 12 Microns

We present the first results of a study of faint 12 micron sources detected with the WISE survey mission. A deep field around the north Ecliptic pole provides 5sigma sensitivity of around 100microJy, while a side field at high Galactic latitude provides an area of around 10 square degrees. Number counts for these sources are compared to smaller area and higher flux surveys carried out by ISO and IRAS. The WISE survey data show a continued increase in sources out to fainter limits.

Benford, Dominic J.↗