Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Accelerated 133 Xe Quantification in Samples Containing Significant 133 mXe

The quantification of 133 Xe in the presence of its mother radionuclide 133 mXe requires the full quantification of both to perform the ingrowth correction for 133 Xe. Due to the nature of both of these radionuclides, the 133 mXe requires significantly more time to quantify by High Purity Germanium (HPGe) detectors due to lower production yields, lower gamma emission probabilities, and lower detection efficiencies. This work shows that 133 Xe and 133 mXe quantification can be accelerated by measuring the 133m:133 activity ratio for a large batch of material and applying this activity ratio to assays of lower activity subsamples of the same batch of material. Included in this report are derivations of the required decay correction equations, and experiments using actual samples to validate the performance of these equations. A detector calibration method is also shown that leverages this method as an alternative to existing calibration methods for 133 mXe quantification.

133mXe↗

The Association of Age-Related and Off-Target Retention with Longitudinal Quantification of [ 18 F]MK6240 Tau PET in Target Regions

6-(fluoro- 18 F)-3-(1H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine ([ 18 F]MK6240) tau PET tracer quantifies the brain tau neurofibrillary tangle load in Alzheimer disease. The aims of our study were to test the stability of common reference region estimates in the cerebellum over time and across diagnoses and evaluate the effects of age-related and off-target retention on the longitudinal quantification of [ 18 F]MK6240 in target regions. Methods: We assessed reference, target, age-related, and off-target regions in 125 individuals across the aging and Alzheimer disease spectrum with longitudinal [ 18 F]MK6240 SUVs and SUV ratios (SUVRs) (mean ± SD, 2.25 ± 0.40 y of follow-up). We obtained SUVR from meninges, exhibiting frequent off-target retention with [ 18 F]MK6240. Additionally, we compared tracer uptake between 37 cognitively unimpaired young (CUY) (mean age, 23.41 ± 3.33 y) and 27 cognitively unimpaired older (CU) adults (amyloid-β–negative and tau-negative, 58.50 ± 9.01 y) to identify possible nonvisually apparent, age-related signal. Two-tailed t testing and Pearson correlation testing were used to determine the difference between groups and associations between changes in region uptake, respectively. Results: Inferior cerebellar gray matter SUV did not differ on the basis of diagnosis and amyloid-β status, cross-sectionally and over time. [ 18 F]MK6240 uptake significantly differed between CUY and CU adults in the putamen or pallidum (affecting ~75% of the region) and in the Braak II region (affecting ~35%). Changes in meningeal and putamen or pallidum SUVRs did not significantly differ from zero, nor did they vary across diagnostic groups. We did not observe significant correlations between longitudinal changes in age-related or meningeal off-target retention and changes in target regions, whereas changes in all target regions were strongly correlated. Conclusion: Inferior cerebellar gray matter was similar across diagnostic groups cross-sectionally and stable over time and thus was deemed a suitable reference region for quantification. Despite not being visually perceptible, [ 18 F]MK6240 has age-related retention in subcortical regions, at a much lower magnitude but topographically colocalized with significant off-target signal of the first-generation tau tracers. The lack of correlation between changes in age-related or meningeal and target retention suggests little influence of possible off-target signals on longitudinal tracer quantification. Nevertheless, the age-related retention in the Braak II region needs to be further investigated. Future postmortem studies should elucidate the source of the newly reported age-related [ 18 F]MK6240 signal, and in vivo studies should further explore its impact on tracer quantification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rare Earth Element Detection and Quantification in Coal and Rock Mineral Matrices

As global demand for rare earth elements (REEs) increases, maintaining the production and supply chain is critical. Technologies capable of being used in the field and in situ in the subsurface for rapid REE detection and quantification facilitates the efficient mining of known resources and exploration of new and unconventional resources. Laser-induced breakdown spectroscopy (LIBS) is a promising technique for rapid elemental analysis both in the laboratory and in the field. Multiple articles have been published evaluating LIBS for detection and quantification of REEs; however, REEs in their natural deposits have not been adequately studied. In this work, detection and quantification of two REEs, La and Nd, have been studied in both synthetic and natural mineral matrices at concentrations relevant to REE extraction. Measurements were performed on REE-containing rock and coal samples (natural and synthetic) utilizing different LIBS instruments and techniques, specifically a commercial benchtop instrument, a custom benchtop instrument (single- and double-pulse modes), and a custom LIBS probe currently being developed for in situ, subsurface, borehole wall detection and quantification of REEs. Plasma expansion, emission intensity, detection limits, and double-pulse signal enhancement were studied. The limits of detection (LOD) were found to be 10/14 ppm for La and 15/25 ppm for Nd in simulated coal/rock matrices in single-pulse mode. Signal enhancement of 3.5 to 6-fold was obtained with double-pulse mode as compared to single-pulse operation.

La detection↗

Colour thresholding and objective quantification in bioimaging

Computer imaging is rapidly becoming an indispensable tool for the quantification of variables in research and medicine. Whilst its use in medicine has largely been limited to qualitative observations, imaging in applied basic sciences, medical research and biotechnology demands objective quantification of the variables in question. In black and white densitometry (0-256 levels of intensity) the separation of subtle differences between closely related hues from stains is sometimes very difficult. True-colour and real-time video microscopy analysis offer choices not previously available with monochrome systems. In this paper we demonstrate the usefulness of colour thresholding, which has so far proven indispensable for proper objective quantification of the products of histochemical reactions and/or subtle differences in tissue and cells. In addition, we provide interested, but untrained readers with basic information that may assist decisions regarding the most suitable set-up for a project under consideration. Data from projects in progress at Tulane are shown to illustrate the advantage of colour thresholding over monochrome densitometry and for objective quantification of subtle colour differences between experimental and control samples.

NASA Discipline Neuroscience↗

Uncertainty Quantification of CFD Data Generated for a Model Scramjet Isolator Flowfield

Computational fluid dynamics is now considered to be an indispensable tool for the design and development of scramjet engine components. Unfortunately, the quantification of uncertainties is rarely addressed with anything other than sensitivity studies, so the degree of confidence associated with the numerical results remains exclusively with the subject matter expert that generated them. This practice must be replaced with a formal uncertainty quantification process for computational fluid dynamics to play an expanded role in the system design, development, and flight certification process. Given the limitations of current hypersonic ground test facilities, this expanded role is believed to be a requirement by some in the hypersonics community if scramjet engines are to be given serious consideration as a viable propulsion system. The present effort describes a simple, relatively low cost, nonintrusive approach to uncertainty quantification that includes the basic ingredients required to handle both aleatoric (random) and epistemic (lack of knowledge) sources of uncertainty. The nonintrusive nature of the approach allows the computational fluid dynamicist to perform the uncertainty quantification with the flow solver treated as a "black box". Moreover, a large fraction of the process can be automated, allowing the uncertainty assessment to be readily adapted into the engineering design and development workflow. In the present work, the approach is applied to a model scramjet isolator problem where the desire is to validate turbulence closure models in the presence of uncertainty. In this context, the relevant uncertainty sources are determined and accounted for to allow the analyst to delineate turbulence model-form errors from other sources of uncertainty associated with the simulation of the facility flow.

Baurle, R. A.↗

Validation and Bias Quantification of Criticality Safety Codes for SRNS Operations

The validation and bias quantification methods employed by the Criticality Safety Engineering group at Savannah River Nuclear Solutions are discussed. Both SCALE and MCNP are validated against benchmark experiments, where these benchmark models have been divided into subgroups representative of the types of fissile material operations at SRNS. A quantification of the bias is made for each subgroup for each code and the three methods employed for quantification are discussed. The bias information is employed directly in the establishment of the Upper Safety Limit (USL) value of the neutron multiplication factor when using standardized documented SRNS methods. A simple example of validation and bias quantification is given and the procedure for setting the USL using the derived bias information is also presented.

97 MATHEMATICS AND COMPUTING↗

A TREATMENT OF THE MEASUREMENT UNCERTAINTY FOR XENON VOLUME QUANTIFICATION

Treaty monitoring gas measurement systems that measure radioxenon typically report results as an activity concentration, which is the measured radioxenon activity divided by the amount of stable xenon present. While the nuclear activity uncertainty has been studied in detail and is driven primarily by counting statistics, the uncertainty for the volume measurement has been considered in less detail. A framework for a more complete consideration of the uncertainty for the volume measurement has been developed. This type of analysis can help drive the system requirements for the volume quantification while the system is still being developed or added to advanced fielded systems. Depending on the accuracy requirements for the activity concentration, the volume quantification measurement and analysis can be developed to a suitably high level of accuracy. Nominally, it is best to have the activity concentration uncertainty limited by the uncertainty of the activity measurement because it tends to be fundamentally limited by the counting statistics. Volume quantification should be performed more accurately so that the activity concentration uncertainty is not degraded from the counting statistics. This paper will describe in detail a stable gas quantification uncertainty analysis for a xenon monitoring system.

Harper, Warren W.↗

Validation and bias quantification of criticality safety codes for SRNS operations

The validation and bias quantification methods employed by the Criticality Safety Engineering group at Savannah River Nuclear Solutions (SRNS) are discussed. Both SCALE and MCNP are validated against benchmark experiments, where these benchmark models have been divided into subgroups representative of the types of fissile material operations at SRNS. A quantification of the bias is made for each subgroup for each code and the three methods employed for quantification are discussed. The bias information is employed directly in the establishment of the Upper Safety Limit (USL) value of the neutron multiplication factor when using standardized documented SRNS methods. A simple example of validation and bias quantification is given and the procedure for setting the USL using the derived bias information is also presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identification and Quantification of Beta-Emitters in Waste Packages by Segmented Gamma-Scanning - 20114

A commonly applied method for the non-destructive characterization of the radioactive inventory of waste packages (e.g. 200-l drums) is segmented gamma-scanning. The gamma-emitting inventory is identified via their characteristic lines in the measured spectra. The corresponding net peak areas allow for quantification applying appropriate models. The identification and quantification of beta-emitters present in the waste package require further evaluation. While some of them emit gamma-rays, too, which can be used for identification and quantification, pure beta-emitters contribute to the gamma-spectra only by their Bremsstrahlung-spectra. {sup 32}P, {sup 90}Sr and {sup 90}Y are typical representatives of these isotopes. A method is developed for identification and quantification of these pure beta-emitters in radioactive waste packages. Origin of the procedure is the evaluation of the measured gamma-spectrum. After the identification of all lines present in the spectrum (characteristic gamma-lines, single- and double-escape-lines, X-ray-lines, annihilation peak etc.) this information is used together with calibration data of the detection system and further a-priori information like matrix composition, cross-section data from databases etc. to simulate the spectra without the Bremsstrahlung-components by an appropriate method. This may be Monte Carlo simulations or, like in our case, a computer code taking into account mathematical descriptions of the physical effects like photo effect, (multiple) Compton scattering, backscattering etc. and the attenuation effects of the waste matrix. In any case, the resulting spectrum must simulate the real spectrum without its Bremsstrahlung-component as good as possible. Subtracting the simulated from the measured spectrum then results in the Bremsstrahlung-components caused by the beta-emitters. Prior to evaluation, a set of Bremsstrahlung-spectra is calculated and stored for different beta-emitters in different matrices using the Bethe-Heitler equation. This data set can be extended for new conditions, if necessary, and is allocated in a data base for future application. Applying a non-linear optimization using the generalized reduced gradient method for comparing the calculated with the derived Bremsstrahlung-spectra results in the identification of the beta-emitter and a factor, which is proportional to its activity. The proportionality is determined by previous calibration measurements. The application of the method is demonstrated by measurements on a 200-l mock-up drum and a real waste package. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Bayesian uncertainty quantification of tristructural isotropic particle fuel silver release: Decomposing model inadequacy plus experimental noise and parametric uncertainties

Tristructural isotropic (TRISO) particle fuel is one of the most promising fuel concepts enabling high temperature and high burnup reactor operation. One dominant source of radioactivity released from the TRISO particles is silver (Ag), which is subject to a high release fraction and long decay life compared to other fission products. Previous modeling efforts using the fuel performance code BISON indicated nonnegligible uncertainties in modeling the diffusion process of fission products in TRISO compared to the Advanced Gas Reactor experiments. The overall uncertainties observed when modeling the fission product diffusion can result from uncertainties in model parameters, noisy experimental measurements, and deficiencies in the developed models. The three types of underlying uncertainties have not yet been properly quantified in open literature. Here, this paper presents the Bayesian uncertainty quantification (UQ) using massively parallelizable Markov chain Monte Carlo samplers. The uncertainties due to model parameters, model inadequacy, and experimental measurement noise are quantified, with the σ term used to represent the sum of the model inadequacy and measurement noise uncertainties. It is worth noting that this is the first time the σ term is inferred for nuclear fuel experiments, as compared to using prescribed values for uncertainty quantification in previous work. The parallelizable Markov chain Monte Carlo samplers efficiently infer the model parameters and the σ term, giving insight into physical parameters like diffusion coefficients and the combined model discrepancy and measurement noise. A subsequent forward uncertainty quantification (UQ) is also performed based on the calibration results to generate more accurate predictions of the Ag release. The model inadequacy plus experimental noise is the most dominant source of uncertainty compared to the parametric uncertainty. All the UQ analyses presented in this work are based on the second series of the irradiation experiments in the Advanced Gas Reactor program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Comparative Analysis of Computational Approaches to Relative Protein Quantification Using Peptide Peak Intensities in Label-free LC-MS Proteomics Experiments

Liquid chromatography coupled with mass spectrometry (LC-MS) is widely used to identify and quantify peptides in complex biological samples. In particular, label-free shotgun proteomics is highly effective for the identification of peptides and subsequently obtaining a global protein profile of a sample. As a result, this approach is widely used for discovery studies. Typically, the objective of these discovery studies is to identify proteins that are affected by some condition of interest (e.g. disease, exposure). However, for complex biological samples, label-free LC-MS proteomics experiments measure peptides and do not directly yield protein quantities. Thus, protein quantification must be inferred from one or more measured peptides. In recent years, many computational approaches to relative protein quantification of label-free LC-MS data have been published. In this review, we examine the most commonly employed quantification approaches to relative protein abundance from peak intensity values, evaluate their individual merits, and discuss challenges in the use of the various computational approaches.

Environmental Molecular Sciences Laboratory↗

Uncertainty quantification and sensitivity analysis with CASL Core Simulator VERA-CS

Uncertainty quantification and sensitivity analysis are important for nuclear reactor safety design and analysis. A 2x2 fuel assembly core design was developed and simulated by the Virtual Environment for Reactor Applications, Core Simulator (VERA-CS) coupled neutronics and thermal-hydraulics code under development by the Consortium for Advanced Simulation of Light Water Reactors (CASL). An approach to uncertainty quantification and sensitivity analysis with VERA-CS was developed and a new toolkit was created to perform uncertainty quantification and sensitivity analysis with fourteen uncertain input parameters. Furthermore, the minimum departure from nucleate boiling ratio (MDNBR), maximum fuel center-line temperature, and maximum outer clad surface temperature were chosen as the selected figures of merit. Pearson, Spearman, and partial correlation coefficients were considered for all of the figures of merit in sensitivity analysis and coolant inlet temperature was consistently the most influential parameter. We used parameters as inputs to the critical heat flux calculation with the W-3 correlation were shown to be the most influential on the MDNBR, maximum fuel center-line temperature, and maximum outer clad surface temperature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An antibody-free platform for multiplexed, sensitive quantification of protein biomarkers in complex biomatrices

Sensitive, multiplexed protein quantification remains challenging despite recent advancements in LC-MS assays for targeted protein biomarker quantification. High-sensitivity protein biomarker measurements usually require immuno-affinity enrichment of target protein; a process which is highly dependent on capture reagent and limited in capability to measure multiple analytes. Herein, we report a novel antibody-free platform, which measures multiple biomarkers from complex matrices employing a strategically optimized solid-phase extraction cleanup and orthogonal multidimensional LC-MS. Eight human protein biomarkers with different specifications were spiked into canine plasma as a model investigation system. The developed strategy achieved the desired sensitivity, robustness, and throughput via the following steps: (1) post digestion mixed-mode cation exchange-reverse phase SPE enrichment cleaned up the sample initially; (2) rapid, high-pH peptide fractionation further eliminated background components efficiently while selectively enriched signature peptides (SP) to provide sufficient sensitivity for multiple targets; and (3) trapping-micro-LC-MS analysis delivered high sensitivity comparable to a nano-LC-MS method but with much better robustness and throughput for the final analysis. Compared with a conventional LC-MS assay with direct protein digestion and limited clean-up, analysis with this antibody-free platform improved the LLOQ by 1–2 orders of magnitude for the eight protein biomarkers, reaching as low as 5 ng/mL in plasma, with feasible robustness and throughput. In conclusion, this platform was applied for the quantification of biomarkers of respiratory conditions in patients with various lung diseases, demonstrating real-world applicability.

59 BASIC BIOLOGICAL SCIENCES↗

Multilevel and multifidelity uncertainty quantification for cardiovascular hemodynamics

Standard approaches for uncertainty quantification in cardiovascular modeling pose challenges due to the large number of uncertain inputs and the significant computational cost of realistic three-dimensional simulations. Here, we propose an efficient uncertainty quantification framework utilizing a multilevel multifidelity Monte Carlo (MLMF) estimator to improve the accuracy of hemodynamic quantities of interest while maintaining reasonable computational cost. This is achieved by leveraging three cardiovascular model fidelities, each with varying spatial resolution to rigorously quantify the variability in hemodynamic outputs. We employ two low-fidelity models (zero- and one-dimensional) to construct several different estimators. Our goal is to investigate and compare the efficiency of estimators built from combinations of these two low-fidelity model alternatives and our high-fidelity three-dimensional models. We demonstrate this framework on healthy and diseased models of aortic and coronary anatomy, including uncertainties in material property and boundary condition parameters. Our goal is to demonstrate that for this application it is possible to accelerate the convergence of the estimators by utilizing a MLMF paradigm. Therefore, we compare our approach to single fidelity Monte Carlo estimators and to a multilevel Monte Carlo approach based only on three-dimensional simulations, but leveraging multiple spatial resolutions. We demonstrate significant, on the order of 10 to 100 times, reduction in total computational cost with the MLMF estimators. We also examine the differing properties of the MLMF estimators in healthy versus diseased models, as well as global versus local quantities of interest. As expected, global quantities such as outlet pressure and flow show larger reductions than local quantities, such as those relating to wall shear stress, as the latter rely more heavily on the highest fidelity model evaluations. Similarly, healthy models show larger reductions than diseased models. In all cases, our workflow coupling Dakota’s MLMF estimators with the SimVascular cardiovascular modeling framework makes uncertainty quantification feasible for constrained computational budgets.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of human nuclear and mitochondrial DNA qPCR assays for quantification accuracy utilizing NIST SRM 2372a

In forensic DNA casework, a highly accurate real-time quantitative polymerase chain reaction (qPCR) assay is recommended per the Scientific Working Group on DNA Analysis Methods (SWGDAM) (SWGDAM Validation Guidelines for DNA Analysis Methods [1]) to determine whether a DNA sample is of sufficient quantity and robust quality to move forward with downstream short tandem repeats (STR) or sequencing analyses. Most of these assays rely on a standard curve, referred to herein and traditionally as absolute qPCR, in which an unknown is compared, relative to that curve. However, one fundamental issue with absolute qPCR is the quantifiable concentration of commercial assay standards can vary depending on (1) origin, i.e., whether from a cell line or a human subject, (2) supplier, (3) lot number, (4) shipping method, etc. In 2018, the National Institute for Standards and Technology (NIST) released a human DNA standard reference material for evaluating qPCR quantification standards, Standard Reference Material (SRM) 2372a, Romsos et al. (2018) [2] which contains three well-characterized human genomic DNA samples: Component A) a single male1 donor, Component B) a single female 1 donor, and Component C) a 1:3 male 2 :female 2 donor, each with certification data for nDNA and informational mitochondrial DNA(mtDNA)/nuclear DNA (nDNA) ratio data. The SRM 2372a was used to assess four qPCR assays: (1) Quantifiler Trio (Thermo Fisher Scientific, Waltham, MA) for nDNA quantification, (2) NovaQUANT (EMD Millipore Corporation, San Diego, CA) for nDNA and mtDNA quantification, (3) a custom duplex mtDNA assay, and (4) a custom triplex mtDNA assay. Additionally, extracts from eighteen (18) skeletal remains were tested with the latter three assays for concordance of DNA concentration and with assays (2) and (3), for the degradation state. Our assessment revealed that an accurate, efficient, and reproducible qPCR assay is dependent on (1) the quality and reliability of the DNA standard, (2) the qPCR chemistry, and (3) the specific primers, and probes (if applicable), used in an assay. Finally, our findings indicate qPCR assays may not always quantify as expected and that performance of each lot should be verified using a well-characterized DNA standard such as the NIST SRM 2372a and adjusted if warranted.

59 BASIC BIOLOGICAL SCIENCES↗

Reduction of detection limit and quantification uncertainty due to interferent by neural classification with abstention

Many measurements in the physical sciences can be cast as counting experiments, where the number of occurrences of a physical phenomenon informs the prevalence of the phenomenon's source. Often, detection of the physical phenomenon (termed signal) is difficult to distinguish from naturally occurring phenomena (termed background). In this case, the discrimination of signal events from background can be performed using classifiers, and they may range from simple, threshold-based classifiers to sophisticated neural networks. These classifiers are often trained and validated to obtain optimal accuracy, however we show that the optimal accuracy classifier does not generally coincide with a classifier that provides the lowest detection limit, nor the lowest quantification uncertainty. Here, we present a derivation of the detection limit and quantification uncertainty in the classifier-based counting experiment case. We also present a novel abstention mechanism to minimize the detection limit or quantification uncertainty a posteriori. We illustrate the method on two data sets from the physical sciences, discriminating Ar-37 and Ar-39 radioactive decay from non-radioactive events in a gas proportional counter, and discriminating neutrons from gammas in an inorganic scintillator and report results therefrom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GenAI4UQ: A software for forward and inverse uncertainty quantification using conditional generative AI

We introduce GenAI4UQ, a software package for forward and inverse uncertainty quantification in model calibration, parameter estimation, and ensemble forecasting. GenAI4UQ leverages a generative AI-based conditional modeling framework to address limitations of traditional inverse modeling techniques, such as Markov Chain Monte Carlo (MCMC) methods. By replacing computationally intensive iterative processes with a direct, learned mapping, GenAI4UQ enables efficient calibration of input parameters and generation of predictions directly from observations. The software supports rapid ensemble forecasting with robust uncertainty quantification while maintaining computational and storage efficiency. Built-in auto-tuning of hyperparameters simplifies model training, ensuring accessibility for users with varying expertise. Its versatile conditional generative framework is applicable across diverse scientific domains. While GenAI4UQ offers significant advantages in flexibility and efficiency, users should interpret its uncertainty estimates with caution in data-sparse scenarios, as the model may overestimate uncertainty—an effect common to all surrogate-based approaches including MCMC with surrogate models. Despite this, GenAI4UQ transforms inverse modeling by providing a fast, reliable, and user-friendly solution. It empowers researchers and practitioners to quickly estimate parameter distributions and generate model predictions for new observations, facilitating efficient decision-making and advancing the state of uncertainty quantification in computational modeling.

97 MATHEMATICS AND COMPUTING↗

Antibody-free, targeted mass-spectrometric approach for quantification of proteins at low picogram per milliliter levels in human plasma/serum

The detection and quantification of proteins at sub-ng/mL concentrations in plasma/serum is of critical importance for candidate biomarker verification. Sensitive detection of serum proteins has typically been achieved by immunoassays; however, de novo development of antibodies is associated with high cost and long lead time. To address this challenge, we developed an antibody-free strategy, termed high-pressure high-resolution separations with intelligent selection and multiplexing (PRISM), for achieving accurate detection of proteins at ~50 pg/mL level in plasma/serum using selected reaction monitoring (SRM). This strategy is based on high resolution reversed phase liquid chromatographic separations for analyte enrichment along with intelligent selection of target fractions via on-line SRM monitoring of internal standards and fraction multiplexing prior to SRM quantification. Our work represents a major technological advance for achieving pg/mL level of serum protein quantification without specific affinity reagents and holds great promise for broad applications in biomarker verification and systems biology studies.

biomarker verification↗