At least 163 records · Page 9

Tuning the Coherent Propagation of Organic Exciton‐Polaritons through Dark State Delocalization

Abstract While there have been numerous reports of long‐range polariton transport at room‐temperature in organic cavities, the spatiotemporal evolution of the propagation is scarcely reported, particularly in the initial coherent sub‐ps regime, where photon and exciton wavefunctions are inextricably mixed. Hence the detailed process of coherent organic exciton‐polariton transport and, in particular, the role of dark states has remained poorly understood. Here, femtosecond transient absorption microscopy is used to directly image coherent polariton motion in microcavities of varying quality factor. The transport is found to be well‐described by a model of band‐like propagation of an initially Gaussian distribution of exciton‐polaritons in real space. The velocity of the polaritons reaches values of ≈ 0.65 × 10 6 m s −1 , substantially lower than expected from the polariton dispersion. Further, it is found that the velocity is proportional to the quality factor of the microcavity. This unexpected link between the quality‐factor and polariton velocity is suggested to be a result of varying admixing between delocalized dark and polariton states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uniform field in microwave cavities through the use of effective magnetic walls

Wire medium (WM) resonators have emerged as a promising realization for plasma haloscopes—devices designed to detect axions, a potential component of dark matter. Key factors influencing the detection probability include cavity volume, resonance quality factor, and form factor. While the form factor has been explored for resonant frequency tuning, its optimization for axion detection remains unexplored. Here, in this work, we present an approach to significantly enhancing the form factor of WM plasma haloscopes. By shifting the metal walls of the resonator by a quarter wavelength, we effectively convert an electric wall boundary condition into a magnetic wall one, allowing for an almost uniform mode. Theoretical analysis and numerical simulations confirm that this modification improves the electric field profile and boosts the form factor, while also slightly enhancing the quality factor. We validate these findings through experimental results from two prototype resonators: one with a standard geometry and another with a quarter-wave air gap between the WM and the walls. Additionally, our method provides a simple way to control the field profile within WM cavities, which can be explored for further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compression through decomposition into browse and residual images

Economical archival and retrieval of image data is becoming increasingly important considering the unprecedented data volumes expected from the Earth Observing System (EOS) instruments. For cost effective browsing the image data (possibly from remote site), and retrieving the original image data from the data archive, we suggest an integrated image browse and data archive system employing incremental transmission. We produce our browse image data with the JPEG/DCT lossy compression approach. Image residual data is then obtained by taking the pixel by pixel differences between the original data and the browse image data. We then code the residual data with a form of variable length coding called diagonal coding. In our experiments, the JPEG/DCT is used at different quality factors (Q) to generate the browse and residual data. The algorithm has been tested on band 4 of two Thematic mapper (TM) data sets. The best overall compression ratios (of about 1.7) were obtained when a quality factor of Q=50 was used to produce browse data at a compression ratio of 10 to 11. At this quality factor the browse image data has virtually no visible distortions for the images tested.

Novik, Dmitry A.↗

Tuned oscillator atomic force microscopy methods and apparatus

Techniques for operating an atomic force microscope, the atomic force microscope comprising a cantilever and configured to image a surface of a sample using a probe tip coupled to the cantilever, the techniques comprising using a controller to perform: obtaining, based on at least one intrinsic parameter of the cantilever, a first quality factor and a first free oscillation amplitude, wherein the cantilever exhibits only one stable oscillation state when oscillating at the first free oscillation amplitude and operating at the first quality factor; and controlling the cantilever to exhibit the only one stable oscillation state by controlling the cantilever to oscillate at a fixed frequency at or near a resonance frequency of the cantilever, oscillate at the first free oscillation amplitude, and operate at the first quality factor.

Schwarz, Udo↗

Wavelength Scaling of Widely-Tunable Terahertz Quantum-Cascade Metasurface Lasers

Terahertz (THz) external-cavity lasers based on quantum-cascade (QC) metasurfaces are emerging as widely-tunable, single-mode sources with the potential to cover the 1--6 THz range in discrete bands with milliwatt-level output power. By operating on an ultra-short cavity with a length on the order of the wavelength, the QC vertical-external-cavity surface-emitting-laser (VECSEL) architecture enables continuous, broadband tuning while producing high quality beam patterns and scalable power output. The methods and challenges for designing the metasurface at different frequencies are discussed. As the QC-VECSEL is scaled below 2 THz, the primary challenges are reduced gain from the QC active region, increased metasurface quality factor and its effect on tunable bandwidth, and larger power consumption due to a correspondingly scaled metasurface area. At frequencies above 4.5 THz, challenges arise from a reduced metasurface quality factor and the excess absorption that occurs from proximity to the Reststrahlen band. The results of four different devices — with center frequencies 1.8 THz, 2.8 THz, 3.5 THz, and 4.5 THz — are reported. Each device demonstrated at least 200 GHz of continuous single-mode tuning, with the largest being 650 GHz around 3.5 THz. The limitations of the tuning range are well modeled by a Fabry-Pérot cavity which accounts for the reflection phase of the metasurface and the effect of the metasurface quality factor on laser threshold. Lastly, the effect of different output couplers on device performance is studied, demonstrating a significant trade-off between the slope efficiency and tuning bandwidth.

47 OTHER INSTRUMENTATION↗

Risk cross sections and their application to risk estimation in the galactic cosmic-ray environment

Radiation risk cross sections (i.e. risks per particle fluence) are discussed in the context of estimating the risk of radiation-induced cancer on long-term space flights from the galactic cosmic radiation outside the confines of the earth's magnetic field. Such quantities are useful for handling effects not seen after low-LET radiation. Since appropriate cross-section functions for cancer induction for each particle species are not yet available, the conventional quality factor is used as an approximation to obtain numerical results for risks of excess cancer mortality. Risks are obtained for seven of the most radiosensitive organs as determined by the ICRP [stomach, colon, lung, bone marrow (BFO), bladder, esophagus and breast], beneath 10 g/cm2 aluminum shielding at solar minimum. Spectra are obtained for excess relative risk for each cancer per LET interval by calculating the average fluence-LET spectrum for the organ and converting to risk by multiplying by a factor proportional to R gamma L Q(L) before integrating over L, the unrestricted LET. Here R gamma is the risk coefficient for low-LET radiation (excess relative mortality per Sv) for the particular organ in question. The total risks of excess cancer mortality obtained are 1.3 and 1.1% to female and male crew, respectively, for a 1-year exposure at solar minimum. Uncertainties in these values are estimated to range between factors of 4 and 15 and are dominated by the biological uncertainties in the risk coefficients for low-LET radiation and in the LET (or energy) dependence of the risk cross sections (as approximated by the quality factor). The direct substitution of appropriate risk cross sections will eventually circumvent entirely the need to calculate, measure or use absorbed dose, equivalent dose and quality factor for such a high-energy charged-particle environment.

NASA Discipline Radiation Health↗

Radiation issues for piloted Mars mission

Current radiation risk for a piloted Mars mission is estimated using the idea of absorbed dose and ICRP-26, LET-dependent quality factors. In a spacecraft with aluminum walls (2 g/sq cm) at solar minimum the calculated dose equivalent is 0.73 Sv for a 406-day mission. Based on the current thinking this leads to an excess cancer mortality in a 35-year male of about 1 percent. About 75 percent of the dose equivalent is contributed by HZE particles and target fragments with average quality factors of 10.3 and 20, respectively. The entire concept of absorbed dose, quality factor, and dose equivalent as applied to such missions needs to be reexamined, in light of the fact that less than 50 percent of the nuclei in the body of the astronaut would have been traversed by a single GCR nuclei in the 406-day mission.

Badhwar, Gautam D.↗

Low-loss superconducting titanium nitride grown using plasma-assisted molecular beam epitaxy

Titanium nitride (TiN) is a known superconducting material that is attractive for use as passive components in superconducting circuits for both conventional and quantum information devices. In contrast to conventional synthesis techniques, here, plasma-assisted molecular beam epitaxy is reported to produce high-quality TiN on bare silicon wafers. Using a rf-plasma source to crack the nitrogen molecules and a conventional high-temperature effusion cell for titanium, TiN growth is completed under nitrogen-rich conditions. The growth and nucleation is monitored in situ, while the structure and composition are characterized using x-ray diffraction, atomic force microscopy, x-ray photoelectron spectroscopy, secondary ion mass spectroscopy, and scanning transmission electron microscopy. The stoichiometric TiN (111) films sit on an amorphous nitride layer with low impurity concentrations. The films superconduct with Tc=5.4 K, and coplanar waveguide resonators are fabricated with a small center width of 6 μm that demonstrate single-photon quality factors approaching 1M and high-power quality factors over 5M without observing saturation.

Richardson, C. J. K. (ORCID:0000000188175347)↗

A tunable dielectric resonator for axion searches at 11 GHz

In the context of axion search with haloscopes, tunable cavity resonators with high quality factor and high effective volume at frequencies above about 8 GHz are central for probing the axion-photon coupling with the required sensitivity to reach the QCD axion models. Higher order modes in dielectrically-loaded cavities allow for higher effective volumes and larger quality factors compared to basic cylindrical cavities, but a proper cavity frequency tuning mechanism to probe broad axion mass ranges is yet not available. In this work, we report about the design and construction of a tunable prototype of a single-shell dielectric resonator with its axion-sensitive pseudo-TM$_{030}$ high-order mode at about 11 GHz frequency. A clamshell tuning method previously tested for empty cylindrical resonators has been perfected for this geometry through simulations and in situ tests conducted at cryogenic temperature. Tuning is accomplished in a range of about 2 $\%$ the central frequency, without significantly impacting the quality factor of about 175000. The experimental results presented in this work demonstrate the tunability of this type of resonator, definitely confirming its applicability to high frequency axion searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High- Q Microwave Dielectric Resonator for Axion Dark-Matter Haloscopes

The frequency band 1–15 GHz provides exciting prospects for resonant axion haloscopes as indicated by cosmological and astrophysical arguments. Among the challenges currently addressed to reach the required sensitivity, the development of high-quality factor cavities that tolerate multitesla fields plays a central role. We report a three-dimensional resonator based on a right-circular copper cavity with hollow cylinders that confine higher-order modes around the cylinder axis. Its effective volume at 10.3 GHz is 3.4 × 10 − 2 l, and under an 8-T field we measure an internal quality factor of more than nine million. A fine-tuning system limited to approximately 1 -MHz range is tested, useful for understanding the conditions required to run a haloscope with a cavity exceeding the axion quality factor. The cavity parameters we report demonstrate the potential of this unique resonator to probe galactic dark-matter axion at scan rates exceeding 2 MHz/day when the cavity is readout by a quantum-limited receiver.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated Uncertainties in Radiation Shielding Effectiveness

The space radiation environment is composed of energetic particles which can deliver harmful doses of radiation that may lead to acute radiation sickness, cancer, and even death for insufficiently shielded crew members. Spacecraft shielding must provide structural integrity and minimize the risk associated with radiation exposure. The risk of radiation exposure induced death (REID) is a measure of the risk of dying from cancer induced by radiation exposure. Uncertainties in the risk projection model, quality factor, and spectral fluence are folded into the calculation of the REID by sampling from probability distribution functions. Consequently, determining optimal shielding materials that reduce the REID in a statistically significant manner has been found to be difficult. In this work, the difference of the REID distributions for different materials is used to study the effect of composition on shielding effectiveness. It is shown that the use of correlated uncertainties allows for the determination of statistically significant differences between materials despite the large uncertainties in the quality factor. This is in contrast to previous methods where uncertainties have been generally treated as uncorrelated. It is concluded that the use of correlated quality factor uncertainties greatly reduces the uncertainty in the assessment of shielding effectiveness for the mitigation of radiation exposure.

Werneth, Charles M.↗

Commissioning of a two-target DC cylindrical magnetron sputter coater for depositing Nb 3 Sn film on Nb superconducting radiofrequency cavities

A DC cylindrical magnetron sputter coater was commissioned and used to coat Nb 2.6 GHz superconducting radiofrequency (SRF) cavity with Nb 3 Sn. The sputter coater has two identical cylindrical magnetrons that can move, with a controlled speed, along the axis of the SRF cavity to coat the inside surface of the cavity. The design of the sputter coater is discussed, along with its performance. Initially, a sample holder that allows coating on flat substrates at positions similar to the equator and beam tubes of a 2.6 GHz SRF cavity was used to test conditions for fabricating Nb 3 Sn layers. Multilayers of Nb and Sn were sequentially sputtered on flat Nb and sapphire substrates mounted on the equivalent positions of the cavity's beam tubes and the equator using the two identical cylindrical magnetrons. Then, the Nb/Sn multilayers were annealed at 950 °C for 3 h. Here, the ~1.2 μm thick Nb 3 Sn film did not show any other Nb–Sn compounds and had a superconducting transition temperature of 17.61–17.76 K. The 2.6 GHz SRF cavity was coated using similar conditions as flat samples. Cryogenic RF testing of the Nb 3 Sn-coated cavity demonstrated a quality factor of 3.2 × 10 8 at an accelerating gradient of 5 MV/m at 4.4 K.

43 PARTICLE ACCELERATORS↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105.This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SERAPH: Wavelike Dark Matter Searches with SRF Cavities

Haloscopes consisting of a microwave cavity with a high quality factor (Q) connected to low-noise electronics have been deployed to detect wavelike axions and dark photons. But the dark matter mass is unknown, so haloscopes must be tunable to search through the photon coupling vs. mass parameter space. Therefore, the scan rate for haloscope experiments is a crucial figure of merit and is proportional to the cavity’s quality factor. State-of-the-art experiments like ADMX currently use copper cavities with 𝑄∼80000. However, implementing superconducting cavities with 𝑄∼1010 can increase the instantaneous scan rate by possibly a factor of 105. This presentation will report progress on the SERAPH experiment, a family of superconducting haloscopes being developed by the Superconducting Quantum Materials and Systems (SQMS) Center. In this presentation, I will first discuss the principles behind operating a haloscope whose bandwidth is much narrower than the dark matter halo energy distribution. I will then describe the first SERAPH experiments implementing a 1.3 GHz Niobium cavity with an ultra-high quality factor (Q~1010) that has achieved the best sensitivity and deepest exclusion to wavelike dark photon dark matter by almost an order of magnitude. Next, I will discuss progress on the next phase of SERAPH, which will search dark photon dark matter using a widely-tunable SRF cavity (4-7 GHz). I will finally describe plans for subsequent SERAPH experiments to search for dark photons and axions with tunable SRF cavities tolerant to multi-Tesla magnetic fields and quantum sensors that subvert the Standard Quantum Limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Si{sub 3}N{sub 4} optomechanical crystals in the resolved-sideband regime

We demonstrate sideband-resolved Si{sub 3}N{sub 4} optomechanical crystals supporting 10{sup 5} quality factor optical modes at 980 nm, coupled to ≈4 GHz frequency mechanical modes with quality factors of ≈3000. Optomechanical electromagnetically induced transparency and absorption are observed at room temperature and in atmosphere with intracavity photon numbers in excess of 10{sup 4}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of High Field Q-Slope in 3 GHz Nb Cavities

A degradation of the unloaded quality factor is commonly observed above about 100 mT in elliptical niobium cavities. The cause of this degradation has not been fully understood yet, but the empirically found solution of heating to about 100-120 C for 24-48 hrs. eliminates the degradation in electropolished fine grain or large grain niobium cavities. While numerous experiments related to this phenomenon have been done at 1.3 GHz and 1.5 GHz, little data exists at other frequencies, and the frequency dependence of this degradation is not clear. We have measured the unloaded quality factor of 3 GHz fine grain niobium cavities, which were chemically polished as the final treatment before RF tests in a vertical Dewar and observed the characteristic degradation in two cavities. The measurement of the quality factor degradation at different bath temperatures points to a field-dependent rather than a temperature-related effect.

Eremeev, Grigory V.↗

Technique for Performing Dielectric Property Measurements at Microwave Frequencies

A paper discusses the need to perform accurate dielectric property measurements on larger sized samples, particularly liquids at microwave frequencies. These types of measurements cannot be obtained using conventional cavity perturbation methods, particularly for liquids or powdered or granulated solids that require a surrounding container. To solve this problem, a model has been developed for the resonant frequency and quality factor of a cylindrical microwave cavity containing concentric cylindrical samples. This model can then be inverted to obtain the real and imaginary dielectric constants of the material of interest. This approach is based on using exact solutions to Maxwell s equations for the resonant properties of a cylindrical microwave cavity and also using the effective electrical conductivity of the cavity walls that is estimated from the measured empty cavity quality factor. This new approach calculates the complex resonant frequency and associated electromagnetic fields for a cylindrical microwave cavity with lossy walls that is loaded with concentric, axially aligned, lossy dielectric cylindrical samples. In this approach, the calculated complex resonant frequency, consisting of real and imaginary parts, is related to the experimentally measured quantities. Because this approach uses Maxwell's equations to determine the perturbed electromagnetic fields in the cavity with the material(s) inserted, one can calculate the expected wall losses using the fields for the loaded cavity rather than just depending on the value of the fields obtained from the empty cavity quality factor. These additional calculations provide a more accurate determination of the complex dielectric constant of the material being studied. The improved approach will be particularly important when working with larger samples or samples with larger dielectric constants that will further perturb the cavity electromagnetic fields. Also, this approach enables the ability to have a larger sample of interest, such as a liquid or powdered or granulated solid, inside a cylindrical container.

Barmatz, Martin B.↗

Two-Tone Spectroscopy of 3D SRF Cavities to Understand Two-Level System Loss

So-called two-level system (TLS) defects are among the most detrimental sources of loss and decoherence in superconducting quantum devices, and their microscopic nature still poorly understood. We develop a two-tone spectroscopy technique to characterize the spectral line width of TLS. This knowledge will help to distinguishes various types of TLS defects. In our experiments we use the fundamental TM010 pass band modes of 9-cell elliptical SRF cavities to probe spectral properties of TLS in native niobium oxide formed on the inside walls of the resonator. We pump one of the modes (4¿/9 through 8¿/9) with continuous high-power to saturate TLSs that couple to this frequency, and we probe the Q-factor of the ¿-mode. We observe increase of the quality factor of the probed ¿-mode when one of the neighboring modes is pumped. Extremely high quality factors of the pass band modes and their relative proximity in the frequency space allow us to estimate the width of the spectral hole burned in the TLS bath absorption spectrum which is related to the line spectral width of the TLS defects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗