Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ptychography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Resolution-enhanced X-ray fluorescence microscopy via deep residual networks

Abstract Multimodal hard X-ray scanning probe microscopy has been extensively used to study functional materials providing multiple contrast mechanisms. For instance, combining ptychography with X-ray fluorescence (XRF) microscopy reveals structural and chemical properties simultaneously. While ptychography can achieve diffraction-limited spatial resolution, the resolution of XRF is limited by the X-ray probe size. Here, we develop a machine learning (ML) model to overcome this problem by decoupling the impact of the X-ray probe from the XRF signal. The enhanced spatial resolution was observed for both simulated and experimental XRF data, showing superior performance over the state-of-the-art scanning XRF method with different nano-sized X-ray probes. Enhanced spatial resolutions were also observed for the accompanying XRF tomography reconstructions. Using this probe profile deconvolution with the proposed ML solution to enhance the spatial resolution of XRF microscopy will be broadly applicable across both functional materials and biological imaging with XRF and other related application areas.

36 MATERIALS SCIENCE↗

Influence of finite spatial coherence on ptychographic reconstruction

X-ray ptychography is an ultrahigh-resolution scanning coherent diffractive imaging technique, allowing quantitative measurements of extended samples and a simultaneous reconstruction of the illuminating wavefront. Recent development of the mixed-state reconstruction algorithm has triggered a certain interest in utilizing partially coherent X-ray sources for ptychography. Here, we study how finite spatial coherence influences the reconstructed image of a test structure. Our work shows that use of a highly coherent illumination provides images with better spatial resolution and fewer artefacts than the approach with partial coherence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent X-ray diffraction from collagenous soft tissues

Coherent X-ray diffraction has been applied in the imaging of inorganic materials with great success. However, its application to biological specimens has been limited to some notable exceptions, due to the induced radiation damage and the extended nature of biological samples, the last limiting the application of most part of the phasing algorithms. X-ray ptychography, still under development, is a good candidate to overcome such difficulties and become a powerful imaging method for biology. We describe herein the feasibility of applying ptychography to the imaging of biological specimens, in particular collagen rich samples. We report here speckles in diffraction patterns from soft animal tissue, obtained with an optimized small angle X-ray setup that exploits the natural coherence of the beam. By phasing these patterns, dark field images of collagen within tendon, skin, bone, or cornea will eventually be obtained with a resolution of 60-70 nm. We present simulations of the contrast mechanism in collagen based on atomic force microscope images of the samples. Simulations confirmed the 'speckled' nature of the obtained diffraction patterns. Once inverted, the patterns will show the disposition and orientation of the fibers within the tissue, by enhancing the phase contrast between protein and no protein regions of the sample. Our work affords the application of the most innovative coherent X-ray diffraction tools to the study of biological specimens, and this approach will have a significant impact in biology and medicine because it overcomes many of the limits of current microscopy techniques.

59 BASIC BIOLOGICAL SCIENCES↗

A lightweight, user-configurable detector ASIC digital architecture with on-chip data compression for MHz X-ray coherent diffraction imaging

Today, most X-ray pixel detectors used at light sources transmit raw pixel data off the detector ASIC. With the availability of more advanced ASIC technology nodes for scientific application, more digital functionalities from the computing domains (e.g., compression) can be integrated directly into a detector ASIC to increase data velocity. In this paper, we describe a lightweight, user-configurable detector ASIC digital architecture with on-chip compression which can be implemented in 130 nm technologies in a reasonable area on the ASIC periphery. In addition, we present a design to efficiently handle the variable data from the stream of parallel compressors. The architecture includes user-selectable lossy and lossless compression blocks. The impact of lossy compression algorithms is evaluated on simulated and experimental X-ray ptychography datasets. This architecture is a practical approach to increase pixel detector frame rates towards the continuous 1 MHz regime for not only coherent imaging techniques such as ptychography, but also for other diffraction techniques at X-ray light sources.

47 OTHER INSTRUMENTATION↗

STEM Ptychographic Holography of Electric and Magnetic Potentials

The development of fast an efficient direct electron imaging detectors have enabled the advancement of phase-imaging techniques in STEM such as iterative ptychography. As beneficial as these techniques are to imaging phase objects, the information recorded in the raw data is due to phase gradients across the probe, so it can be challenging to reconstruct slowly varying phase at lower spatial frequencies such as those induced by electric or magnetic potentials within the specimen. STEM holography [1,2] is an interferometric 4D-STEM technique where electrons in the beam are coherently divided into a superposition of two or more spatially separated probes which are then scanned over the specimen. For example, in a two-beam superposition, the two probes form overlapping bright field discs at the detector which then interfere (left of Fig. 1). Furthermore, if one probe passes through vacuum while the other transmits through the specimen, the resulting relative phase shift can be measured by recording shifts in the interference pattern. STEM holography is thus directly sensitive to the phase of the probe relative to the reference beam, and this phase can be measured regardless of the convergence angle of the probe, unlike single beam ptychography.

Biological Sciences↗

Ptychographic Fresnel coherent diffractive imaging

This paper reports improved reconstruction of complex wave fields from extended objects. The combination of ptychography with Fresnel diffractive imaging results in better reconstructions with fewer iterations required to convergence than either method considered separately. The method is applied to retrieve the projected thickness of a gold microstructure and comparative results using ptychography and Fresnel diffractive imaging are presented.

07 ISOTOPE AND RADIATION SOURCES↗

Non-Blind Deblurring for Fluorescence: A Deformable Latent Space Approach with Kernel Parameterization

We report N\non-blind deblurring (NBD) is a modeling method of the image deblurring problem in computer vision, where the blurring kernel is known or can be externally estimated. In this paper, we attempt to solve a parametric NBD problem, inspired by the simultaneous acquisition of ptychography and fluorescent imaging (FI). Ptychography is an imaging method that favors larger probes, i.e. convolutional kernels, while FI relies on a small probe for high resolution. Also, the kernel can be solved during ptychographic reconstruction. With Ptycho-FI using the same larger kernel, we can perform NBD on the blurred fluorescent images to achieve high-resolution FI, and thus speed up the experiments. To this end, we design a deep latent space deformation network that is directly parameterized by the kernel. The network consists of three components: encoder, deformer, and decoder, where the deformer is specifically meant to rectify the latent space representations of blurred images to a standard latent space, regardless of the kernel. The deformation network is trained with a two-stage training scheme. We conduct extensive experiments to confirm that our parametric model can adapt to drastically different blurring kernels and perform robust deblurring.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2022 AI Testbed Expeditions Report

By exploiting the coherent properties of a light source, coherent diffraction imaging (CDI) is able to obtain the sample image at a nanoscale resolution using the measured diffraction pattern. Bragg Coherent Diffraction Imaging (BCDI) has become valuable for recovering the displacement and strain field of crystals, providing a valuable tool in material science and solid-state physics. X-ray ptychography is another emerging CDI technique that can produce a high-resolution image of the extended sample and has become popular in many research areas (e.g., materials science, biology, electronics, and optics characterization). CDI including BCDI and ptychography has become an established technique in Synchrotron Facilities including the Advanced Photon Source (APS) and will greatly benefit from the 100x coherent flux increase of the upcoming APS Upgrade (APSU). The current image formation process in CDI employs iterative phase retrieval algorithms, which is a time-consuming and computationally expensive process. Especially after APSU, the traditional iterative methods will not be able to match the experimental data acquisition speed. We employ deep learning (DL) approach to replace the iterative approaches, therefore allowing hundreds of times faster recovery of the object. We developed AutoPhaseNN, a DL-based approach which learns to solve the inverse problem without labeled data. Taking 3D BCDI as a representative technique, AutoPhaseNN has been demonstrated to be one hundred times faster than traditional iterative phase retrieval methods while providing comparable image quality. The current network is trained with 64 x 64 x 64 data size, to achieve higher resolution imaging, we will need to scale the network to input and train/infer 3D arrays of size 256 x 256 x 256 (today) and of size 2560x2560x2560 (APSU). However, the scalability of the network is restricted due to the memory-intensive training process. To perform the training for a 256 x 256 x 256 data size, the required memory exceeds the capacity of the current machine. In this project, we explore using Sambanova system to train the network for the direct data inversion for CDI.

36 MATERIALS SCIENCE↗

X-Ray Scattering and Imaging Studies of Electrode Structure and Dynamics

We will review structures and dynamics of electrode interfaces studied in situ using x-ray scattering and imaging techniques. The examples cover single-crystal and nanocrystal structures relevant to electrocatalytic activities, anodic oxidation and corrosion, aqueous dissolution reactions, surface reconstructions, and surface modifications by under potential deposition. Here, the x-ray techniques include the widely used traditional surface x-ray scattering, such as crystal truncation rods and x-ray reflectivity, as well as recently developed resonance surface scattering, coherent surface x-ray photon correlation spectroscopy, coherent x-ray Bragg diffraction imaging, and surface ptychography. Results relevant to various electrochemical phenomena will be highlighted.

36 MATERIALS SCIENCE↗

Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy

Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the mapping of electric, magnetic, and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electron Microscope Pixel Array Detector (EMPAD-G2), addresses this challenge by advancing the technology of a previous generation PAD, the EMPAD. The EMPAD-G2 images continuously at a frame-rates up to 10 kHz with a dynamic range that spans from low-noise detection of single electrons to electron beam currents exceeding 180 pA per pixel, even at electron energies of 300 keV. The EMPAD-G2 enables rapid collection of high-quality STEM data that simultaneously contain full diffraction information from unsaturated bright-field disks to usable Kikuchi bands and higher-order Laue zones. Test results from 80 to 300 keV are presented, as are first experimental results demonstrating ptychographic reconstructions, strain and polarization maps. We introduce a new information metric, the maximum usable imaging speed (MUIS), to identify when a detector becomes electron-starved, saturated or its pixel count is mismatched with the beam current.

36 MATERIALS SCIENCE↗

Evaluation of Chemical and Structural Homogeneity in Single Particles of Li 1-x Ni 0.33 Mn 0.33 Co 0.33 0 2

Identifying irreversible phenomena at single particles of battery cathode materials is an important step to understanding degradation pathways upon cycling. LiNi 0.33 Mn 0.33 Co 0.33 O 2 (LiNMC(111)) single particles of size 200 x 300 nm were studied before and after cycling using Scanning X-ray Diffraction Microscopy (SXDM) and ptychographic microscopy. Here, with resolutions of 30 and 5 nm, respectively, it was possible to map the (003) reflection and nickel oxidation state changes in single particles at different states of charge. While the compositions measured by the c lattice parameter from SXDM were found to be homogeneous, mapping at higher resolution using ptychography revealed that Ni oxidation states decrease sharply 0-25 nm from the edge, then trail into a steady oxidation state toward the interior of the particle. Within the 30 nm length scale, we conclude that LiNi 0.33 Mn 0.33 Co 0.33 O 2 single particles are highly structurally reversible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomically resolved edges and defects in lead halide perovskites

Although edges and defects constitute only a small fraction of crystalline materials, they exert an outsized impact on a material′s properties. Organic–inorganic halide perovskites are promising next-generation semiconductor materials with superior cost effectiveness and interesting optoelectronic properties. However, clear images of their edges have remained challenging to obtain owing to their extreme sensitivity. Using truly high-speed ultralow-dose four-dimensional scanning transmission electron microscopy with dose fractionation, we perform ptychography at, to our knowledge, the lowest-dose atomic resolution to date, revealing not only the detailed atomic structure of the edges of a halide perovskite but also their structural dynamics. Here, a majority methylammonium (MA) and iodine (I) edge termination is observed in methylammonium lead iodide (MAPbI 3 ), and the damage rate of its edges and internal defects is found to depend on the concentration and type of vacancies present, with a preponderance of I vacancies in particular correlating with higher rates of damage.

4D-STEM↗

Recent Advances in Small Angle X-ray Scattering for Superlattice Study

Small-angle x-ray scattering is used for the structure determination of superlattice for its superior resolution, nondestructive nature, and high penetration power of x rays. With the advent of high brilliance x-ray sources and innovative computing algorithms, there have been notable advances in small angle x-ray scattering analysis of superlattices. High brilliance x-ray beams have made data analyses less model-dependent. Additionally, novel data acquisition systems are faster and more competitive than ever before, enabling a more accurate mapping of the superlattices' reciprocal space. Fast and high-throughput computing systems and algorithms also make possible advanced analysis methods, including iterative phasing algorithms, non-parameterized fitting of scattering data with molecular dynamics simulations, and the use of machine learning algorithms. As a result, solving nanoscale structures with high resolutions has become an attainable task. In this review, we highlight new developments in the field and introduce their applications for the analysis of nanoscale ordered structures, including nanoparticle supercrystals, nanoscale lithography patterns, and supramolecular self-assemblies. Particularly, we highlight the reciprocal space mapping techniques and the use of iterative phase retrieval algorithms. We also cover coherent-beam-based small angle x-ray scattering techniques such as ptychography and ptycho-tomography in view of the traditional small angle x-ray scattering perspective.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A versatile high-speed x-ray microscope for sub-10 nm imaging

We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.

36 MATERIALS SCIENCE↗

Advanced monolithic 2D multilayer Laue lens (MLL) optics for hard x-ray nanofocusing and nanotomography

We report on the development of a new generation of monolithic two-dimensional (2D) multilayer Laue lens (MLL) optics suitable for high-resolution hard x-ray nanoimaging. The 2D optics were assembled on microfabricated silicon templates with high orthogonality and lateral alignment precision, which were characterized using white-light interferometry and confirmed by x-ray measurements. The developed monolithic 2D MLL optics were successfully employed for hard x-ray nanofocusing and nanotomography experiments using the ptychography imaging modality, demonstrating sub-10 nm resolution in 2D and sample-limited ∼30 nm in three-dimensional while exhibiting excellent stability during extended measurements. The new 2D MLL templates with high alignment accuracy represent an important step forward in the development of 2D MLL optics toward direct nanoimaging experiments with sub-10 nm spatial resolution.

36 MATERIALS SCIENCE↗

PtychoShelves , a versatile high-level framework for high-performance analysis of ptychographic data

Over the past decade, ptychography has been proven to be a robust tool for non-destructive high-resolution quantitative electron, X-ray and optical microscopy. It allows for quantitative reconstruction of the specimen's transmissivity, as well as recovery of the illuminating wavefront. Additionally, various algorithms have been developed to account for systematic errors and improved convergence. With fast ptychographic microscopes and more advanced algorithms, both the complexity of the reconstruction task and the data volume increase significantly. PtychoShelves is a software package which combines high-level modularity for easy and fast changes to the data-processing pipeline, and high-performance computing on CPUs and GPUs.

97 MATHEMATICS AND COMPUTING↗

Fast digital lossy compression for X-ray ptychographic data

Increases in X-ray brightness from synchrotron light sources lead to a requirement for higher frame rates from hybrid pixel array detectors (HPADs), while also favoring charge integration over photon counting. However, transfer of the full uncompressed data will begin to constrain detector design, as well as limit the achievable continuous frame rate. Here a data compression scheme that is easy to implement in a HPAD's application-specific integrated circuit (ASIC) is described, and how different degrees of compression affect image quality in ptychography, a commonly employed coherent imaging method, is examined. Using adaptive encoding quantization, it is shown in simulations that one can digitize signals up to 16383 photons per pixel (corresponding to 14 bits of information) using only 8 or 9 bits for data transfer, with negligible effect on the reconstructed image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗