Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Remote Sensing of Spatial Distributions of Greenhouse Gases in the Los Angles Basin

The Los Angeles air basin is a significant anthropogenic source of greenhouse gases and pollutants including CO2, CH4, N2O, and CO, contributing significantly to regional and global climate change. Recent legislation in California, the California Global Warming Solutions Act (AB32), established a statewide cap for greenhouse gas emissions for 2020 based on 1990 emissions. Verifying the effectiveness of regional greenhouse gas emissions controls requires high-precision, regional-scale measurement methods combined with models that capture the principal anthropogenic and biogenic sources and sinks. We present a novel approach for monitoring the spatial distributions of greenhouse gases in the Los Angeles basin using high resolution remote sensing spectroscopy. We participated in the CalNex 2010 campaign to provide greenhouse gas distributions for comparison between top-down and bottom-up emission estimates.

Los Angeles air basin↗

Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection

Carbon dioxide produced through respiration can accumulate rapidly within closed spaces. If not managed, a crew's respiratory rate increases, headaches and hyperventilation occur, vision and hearing are affected, and cognitive abilities decrease. Consequently, development continues on a number of CO2 removal technologies for human spacecraft and spacesuits. Terrestrially, technology development requires precise performance characterization to qualify promising air revitalization equipment. On-orbit, instrumentation is required to identify and eliminate unsafe conditions. This necessitates accurate in situ CO2 detection. Recursive compensation algorithms were developed for sub-ambient detection of CO2 with commercial off-the-shelf (COTS) non-dispersive infrared (NDIR) sensors. In addition, the source of the exponential loss in accuracy is developed theoretically. The basis of the loss can be explained through thermal, Doppler, and Lorentz broadening effects that arise as a result of the temperature, pressure, and composition of the gas mixture under analysis. The objective was to develop a mathematical routine to compensate COTS CO2 sensors relying on NDIR over pressures, temperatures, and compositions far from calibration conditions. The routine relies on a power-law relationship for the pressure dependency of the sensors along with an equivalent pressure to account for the composition dependency. A Newton-Raphson iterative technique solves for actual carbon dioxide concentration based on the reported concentration. Moreover, first principles routines were established to predict mixed-gas spectra based on sensor specifications (e.g., optical path length). The first principles model can be used to parametrically optimize sensors or sensor arrays across a wide variety of pressures/temperatures/ compositions. In this work, heuristic scaling arguments were utilized to develop reasonable compensation techniques. Experimental results confirmed this approach and provided evidence that composition broadening significantly alters spectra when pressure is reduced. Consequently, a recursive compensation technique was developed with the Newton-Raphson method, which was subsequently verified through experimentation.

Swickrath, Michael J.↗

Experimental Studies of the Formation/Deposition of Sodium Sulfate in/from Combustion Gases

Processes related to the hot corrosion of gas turbine components were examined in two separate investigations. Monochromatic laser light was used to probe condensation onset and condensate film growth (via interference of reflected light) on electrically heated ribbons immersed in seeded, flat flame combustion product gases. Boron trichloride is used as the seed gas in these preliminary experiments conducted to obtain precise measurements of the dew point/deposition rates. Because of the importance of gaseous Na(g) as a precursor to NaSO4 formation, the kinetics and mechanisms of the heterogeneous reaction H(g) + NaCl(s) yields Na(g) + HCl(g) was studied using atomic absorption spectroscopy combined with microwave discharge-vacuum flow reactor techniques at moderate temperatures. Preliminary results indicate the H-atom attack of solid NaCl vaporization is negligible; hence the corresponding gas phase (homogeneous) reaction no role in the observed Na(g) production.

Rosner, D. E.↗

The extragalactic nature of CL4

The variable, unresolved radio source CL4 (2048 + 312) is identified as a quasar, in light of spectroscopy of its faint optical counterpart which shows a single, broad emission line at 6480 A. Although candidate redshifts of 1.31, 2.39, and 3.18 are proposed for identification of the emission feature as Mg II, semiforbidden C III, and C IV, respectively, the precise redshift cannot be determined without an extension of the current spectral coverage of this red object into the blue. CL4, together with the radio source 1910 + 052, which shows similar properties and for which an optical identification search was unsuccessfully conducted, is part of a group of eight compact, variable radio sources which may be related to SS 433. A compilation of evidence for this association shows that none of the eight objects are good candidates for an SS 433 analog.

Margon, B.↗

HabEx Space Telescope Exoplanet Instruments

The HabEx (Habitable Exoplanet) space telescope mission concept carries two complementary optical systems as part of its baseline design, a coronagraph and a starshade, that are designed to detect and characterize planetary systems around nearby stars. The starshade is an external occulter which would be 72 m in diameter and fly some 124,000 km ahead of the telescope. A starshade instrument on board the telescope enables formation flying to maintain the starshade within 1 m of the line of sight to the star. The starshade instrument has various modes, including imaging from the near UV through to the near infrared and integral field spectroscopy in the visible band. The coronagraph would provide imaging and integral field spectroscopy in the visible band and would reach out to 1800 nm for low resolution spectroscopy in the near infrared. To provide the necessary stability for the coronagraph, the telescope would be equipped with a laser metrology system allowing measurement and control of the relative positions of the principal mirrors. In addition, a fine guidance sensor is needed for precision attitude control. The requirements for telescope stability for coronagraphy are discussed. The design and requirements on the starshade will also be discussed.

Marchen, Luis↗

New observations of stratospheric N2O5

The unequivocal detection of N2O5 in the stratosphere was reported by Toon et al. based on measurements of the absorption by the N2O5 bands at 1246 and 1720/cm in solar occulation spectra recorded at sunrise near 47 S latitude by the Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment during the Spacelab 3 (SL3) shuttle mission. Additional measurements and analysis of stratospheric N2O5 derived from the ATMOS/SL3 spectra are reported. The primary results are the detection and measurement of N2O5 absorption at sunset in the lower stratosphere, the inversion of a precise (approximately 10 percent) N2O5 sunrise vertical distribution between 25.5 and 37.5 km altitude, and the identification and measurement of absorption by the N2O5 743/cm band at sunrise. Assuming 4.32 x 10(sup -17) and 4.36 x 10(sup -17)/cm/molecule/sq cm respectively for the integrated intensities of the 1246 and 743/cm bands at stratospheric temperatures, retrieved volume mixing ratios in parts per billion by volume (ppbv) at sunrise (47 S latitude) are 1.32 + or - 0.34 at 37.5 km, 1.53 + or - 0.35 at 35.5 km, 1.63 + or - 0.36 at 33.5 km, 1.60 + or - 0.34 at 31.5 km, 1.43 + or - 0.30 at 29.5 km, 1.15 + or - 0.24 at 27.5 km, and 0.73 + or - 0.15 at 25.5 km. Retrieved VMRs in ppbv at sunset (30 N latitude) are 0.13 + or - 0.05 at 29.5 km, 0.14 + or - 0.05 at 27.5 km, and 0.10 + or - 0.04 at 25.5 km. Quoted error limits (1 sigma) include the error in the assumed band intensities (approximately 20 percent). Within the error limits of the measurements, the inferred mixing ratios at sunrise agree with diurnal photochemical model predictions obtained by two groups using current photochemical data. The measured mixing ratios at sunset are lower than the model predictions with differences of about a factor of 2 at 25 km altitude.

Rinsland, C. P.↗

Microwave, Millimeter, Submillimeter, and Far Infrared Spectral Databases

The spectrum of most known astrophysical molecules is derived from transitions between a few hundred to a few hundred thousand energy levels populated at room temperature. In the microwave and millimeter wave regions. spectroscopy is almost always performed with traditional microwave techniques. In the submillimeter and far infrared microwave technique becomes progressively more technologically challenging and infrared techniques become more widely employed as the wavelength gets shorter. Infrared techniques are typically one to two orders of magnitude less precise but they do generate all the strong features in the spectrum. With microwave technique, it is generally impossible and rarely necessary to measure every single transition of a molecular species, so careful fitting of quantum mechanical Hamiltonians to the transitions measured are required to produce the complete spectral picture of the molecule required by astronomers. The fitting process produces the most precise data possible and is required in the interpret heterodyne observations. The drawback of traditional microwave technique is that precise knowledge of the band origins of low lying excited states is rarely gained. The fitting of data interpolates well for the range of quantum numbers where there is laboratory data, but extrapolation is almost never precise. The majority of high resolution spectroscopic data is millimeter or longer in wavelength and a very limited number of molecules have ever been studied with microwave techniques at wavelengths shorter than 0.3 millimeters. The situation with infrared technique is similarly dire in the submillimeter and far infrared because the black body sources used are competing with a very significant thermal background making the signal to noise poor. Regardless of the technique used the data must be archived in a way useful for the interpretation of observations.

Pearson, J. C.↗

Fabricating Radial Groove Gratings Using Projection Photolithography

Projection photolithography has been used as a fabrication method for radial grove gratings. Use of photolithographic method for diffraction grating fabrication represents the most significant breakthrough in grating technology in the last 60 years, since the introduction of holographic written gratings. Unlike traditional methods utilized for grating fabrication, this method has the advantage of producing complex diffractive groove contours that can be designed at pixel-by-pixel level, with pixel size currently at the level of 45 45 nm. Typical placement accuracy of the grating pixels is 10 nm over 30 nm. It is far superior to holographic, mechanically ruled or direct e-beam written gratings and results in high spatial coherence and low spectral cross-talk. Due to the smooth surface produced by reactive ion etch, such gratings have a low level of randomly scattered light. Also, due to high fidelity and good surface roughness, this method is ideally suited for fabrication of radial groove gratings. The projection mask is created using a laser writer. A single crystal silicon wafer is coated with photoresist, and then the projection mask, with its layer of photoresist, is exposed for patterning in a stepper or scanner. To develop the photoresist, the fabricator either removes the exposed areas (positive resist) of the unexposed areas (negative resist). Next, the patterned and developed photoresist silicon substrate is subjected to reactive ion etching. After this step, the substrate is cleaned. The projection mask is fabricated according to electronic design files that may be generated in GDS file format using any suitable CAD (computer-aided design) or other software program. Radial groove gratings in off-axis grazing angle of incidence mount are of special interest for x-ray spectroscopy, as they allow achieving higher spectral resolution for the same grating area and have lower alignment tolerances than traditional in-plane grating scheme. This is especially critical for NASA Constellation- X project that will utilize hundreds of gratings all of which need to be precisely aligned for x-ray observation of space.

Iazikov, Dmitri↗

Multi-Layer Far-Infrared Component Technology

A method has been developed for fabricating high-reflectivity, multi-layer optical films for the terahertz wavelength region. A silicon mirror with 99.997-percent reflectivity at 70 micrometer wavelength requires an air gap of 17.50 micrometers and a silicon thickness of 5.12 micrometers. This approach obtains pre-thinned wafers of about 20 mm thickness in order to measure their thickness precisely. A gold annulus of appropriate thickness is deposited to reach the required total thickness. This, in turn, has the central aperture etched down to the desired final silicon thickness. Also, the novel Bragg stack optics in this innovation are key to providing Fabry-Perot spectroscopy and improved spectral component technologies of unprecedented resolution, free spectral range, and aperture.

Edwards, Oliver↗

Stratospheric spectroscopy with the far-infrared spectrometer (FIRS-2) - Overview and recent results

The Smithsonian Astrophysical Observatory's program of balloon-borne stratospheric spectroscopic measurements is described, including instrumentation, recent scientific results, and future plans. The design and operation of the FIRS-2 far-infrared spectrometer is discussed. The current status of our efforts to recover mixing-ratio profiles with about 1 percent precision is presented. Representative recent results are shown giving mixing-ratio profiles from 20 to 50 km, selected from the suite HOCl, HCl, HF, NO2, N2O, HNO3, OH, HO2, H2O2, H2O (and isotopes), O2 (and isotopes), O3 (and isotopes), and CO2 (and isotopes). The utility of O2 and CO2 spectral lines for information on view angle or temperature and pressure is discussed. Future plans are mentioned, including the use of FIRS-2 on a balloon platform for UARS correlative measurements, the use of FIRS-2 on the NASA DC-8 platform for polar measurements, and the potential benefits of a FIRS instrument on a Shuttle platform.

Traub, Wesley A.↗

High Throughput, High Yield Fabrication of High Quantum Efficiency Back-Illuminated Photon Counting, Far UV, UV, and Visible Detector Arrays

In this paper we discuss the high throughput end-to-end post fabrication processing of high performance delta-doped and superlattice-doped silicon imagers for UV, visible, and NIR applications. As an example, we present our results on far ultraviolet and ultraviolet quantum efficiency (QE) in a photon counting, detector array. We have improved the QE by nearly an order of magnitude over microchannel plates (MCPs) that are the state-of-the-art UV detectors for many NASA space missions as well as defense applications. These achievements are made possible by precision interface band engineering of Molecular Beam Epitaxy (MBE) and Atomic Layer Deposition (ALD).

spectroscopy↗

Self-scanned photodiode array - High performance operation in high dispersion astronomical spectrophotometry

A multichannel spectrophotometric detector system has been developed using a 1024 element self-scanned silicon photodiode array, which is now in routine operation with the high-dispersion coude spectrograph of the University of Texas McDonald Observatory 2.7-m telescope. Operational considerations in the use of such arrays for high precision and low light level spectrophotometry are discussed. A detailed description of the system is presented. Performance of the detector as measured in the laboratory and on astronomical program objects is described, and it is shown that these arrays are highly effective detectors for high dispersion astronomical spectroscopy.

Vogt, S. S.↗

A JWST Transmission Spectrum of A Nearby Earth-Sized Exoplanet

The critical first step in the search for life on exoplanets over the next decade is to determine whether rocky planets transiting small M-dwarf stars possess atmospheres and, if so, what processes sculpt them over time. Because of its broad wavelength coverage and improved resolution compared with previous instruments, spectroscopy with the James Webb Space Telescope (JWST) offers a new capability to detect and characterize the atmospheres of Earth-sized, M-dwarf planets. Here we use the JWST to independently validate the discovery of LHS 475 b, a warm (586 K), 0.99 Earth-radius exoplanet, interior to the habitable zone, and report a precise 2.9–5.3 μm transmission spectrum using the Near Infrared Spectrograph G395H instrument. With two transit observations, we rule out primordial hydrogen-dominated and cloudless pure methane atmospheres. Thus far, the featureless transmission spectrum remains consistent with a planet that has a high-altitude cloud deck (similar to Venus), a tenuous atmosphere (similar to Mars) or no appreciable atmosphere at all (akin to Mercury). There are no signs of stellar contamination due to spots or faculae. Our observations show that the JWST has the requisite sensitivity to constrain the secondary atmospheres of terrestrial exoplanets with absorption features <50 ppm, and that our current atmospheric constraints speak to the nature of the planet itself, rather than instrumental limits.

JWST↗

"Long-term Timing and High Resolution Spectroscopy of Ultracompact Candidates V407 Vul and RX J0806.3+1527"

We present new, extended X-ray timing measurements of the ultracompact binary candidates V407 Vul and RX J0806.3+1527 (J0806), as well as a summary of the first high resolution X-ray spectrum of 50806 obtained with the Chandra/LETG. The temporal baseline for both objects is about 12 years, and our measurements confirm the secular spin-up of their X-ray periods. The spin-up rate in J0806 is remarkably uniform at 3.55x10(exp -16) Hz/s, with a measurement precision of 0.2%, and we place a limit (90% confidence) on [dn/dt] < 4x10(exp -26) Hz/sq s. Interestingly, for V407 Vul we find the first evidence that the spin-up rate is slowing, with d(sup 2)n/dt(sup 2) = -2.8+/- 1x10(exp -26) Hz/sq s. This provides the first indication that torques in addition to gravitational radiation are present in V407 Vul. Further monitoring could constrain the nature of the torque, as either accretion-induced or due to unipolar induction. We also obtained the first high resolution X-ray spectrum of J0806 with an 80 ksec Chandra/LETG observation. We find evidence for emission features in the 25-50 Angstrom range, with the strongest feature centered at 27 Angstrom. The spectrum appears largely devoid of common lines of oxygen, nitrogen and neon, and we suggest the 27 Angstrom feature may be associated with heavier species, such as magnesium, silicon or sulphur. Deeper observations will be needed to fully exploit the apparently strong diagnostic potential of high resolution spectroscopy for these objects.

Strohmayer, Tod↗

Evaluation of ultraviolet spectrophotometry for simultaneous analysis of alkylbenzenes, alkylnaphthalenes, alkylanthracenes/phenanthrenes and total aromatics in mid-distillate fuels

A rapid ultraviolet spectrophotometric method for the simultaneous determination of aromatics in middistillate fuels was developed and evaluated. In this method, alkylbenzenes, alkylnaphthalenes, alkylanthracenes/phenanthracenes and total aromatics were determined from ultraviolet spectra of the fuels. The accuracy and precision were determined using simulated standard fuels with known compositions. The total aromatics fraction accuracy was 5% for a Jet A type fuel and 0.6% for a broadened properties jet turbine type fuel. Precision, expressed as relative standard deviations, ranged from 2.9% for the alkylanthracenes/phenanthrenes to 15.3% for the alkylbenzenes. The accuracy, however, was less for actual fuel samples when compared to the results obtained by a mass spectrometric method. In addition, the ASTM D-1840 method for naphthalenes by ultraviolet spectroscopy was evaluated.

Kim, W. S.↗

Paraboloidal X-ray telescope mirror for solar coronal spectroscopy

The telescope mirror for the X-ray Spectrograph Spectrometer Telescope System is a sixty degree sector of an extreme off-axis paraboloid of revolution. It was designed to focus a coronal region 1 by 10 arc seconds in size on the entrance slit of the spectrometer after reflection from the gold surface. This paper discusses the design, manufacture, and metrology of the mirror, the methods of precision mechanical metrology used to focus the system, and the mounting system which locates the mirror and has proven itself through vibration tests. In addition, the results of reflection efficiency measurements, alignment tolerances, and ray trace analysis of the effects of misalignment are considered.

Brown, W. A.↗

Laboratory and astronomical spectroscopy of C3H2, the first interstellar organic ring

The first laboratory and astronomical observations of the carbene ring molecule C3H2 briefly reported in a recent Letter are described in detail. In the laboratory, 22 millimeter-wave lines have been measured in a He and C2H2 discharge. From these the three rotational constants and the five fourth-order centrifugal distortion constants of C3H2 have been determined to high precision, allowing, in turn, calculation to 0.1 km/s of the most important lines in the radio and far-IR spectrum; 123 lines in the rotational spectrum with E/K less than 100 K are tabulated. Eleven astronomical transitions have been identified, and in Sgr B2 and Orion KL, rotational temperatures and column densities were derived and compared with those of other hydrocarbons with a similar number of C atoms.

Vrtilek, J. M.↗

Tunable diode laser heterodyne spectrometer for remote observations near 8 microns

Infrared heterodyne spectroscopy is a passive technique employing coherent optical detection for the study of spectral features in remote sources. It employs optical components such as mirrors and lenses normally associated with incoherent optics, but because of it's coherent nature, it offers the advantages of ultrahigh spectral resolving power, high frequency precision, and diffraction limited field-of-view. Attention is given to the development of an ultrahigh resolution diode laser heterodyne spectrometer for observational and laboratory use. The instrument is designed for operation in the spectral range from 7.5 to 8.5 microns. A PbSe tuneable diode laser (TDL) is employed as local oscillator. A closed-cycle cooler is employed to keep the oscillator at operating temperatures in the range from 12 to 60 K. Attention is given to factors determining the TDL heterodyne sensitivity, the spectrometer design, and a survey of 8 micron observations, SiO could be detected in the sunspot spectrum.

Glenar, D. A.↗