Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Calibration standards and field instruments for the precision measurement of insolation

The paper describes the development of an absolute calibration standard for irradiance measurements. This field instrument, designated the Kendall Radiometer System Mark 3, is identical to the PACRAD (Primary Absolute Cavity Radiometer) except for a modification to ensure all weather operation. Two Mark 3 radiometers have been in operation at the JPL's Goldstone Deep Space Communications Complex for over two years and are continuing to provide data which are within plus or minus 1% of the absolute value. A calibration stability analysis is presented for the two instruments.

Reid, M. S.↗

Precise Measurement of Effective Focal Length

Computerized instrument measures effective focal lengths to 0.01 percent accuracy. Laser interferometers measure mirror angle and stage coordinate y in instrument for accurate measurment of focal properties of optical systems. Operates under computer control to measure effective focal length, focal surface shape, modulation transfer function, and astigmatism.

Wise, T. D.↗

The role of the reflection coefficient in precision measurement of ultrasonic attenuation

Ultrasonic attenuation measurements using contact, pulse-echo techniques are sensitive to surface roughness and couplant thickness variations. This can reduce considerable inaccuracies in the measurement of the attenuation coefficient for broadband pulses. Inaccuracies arise from variations in the reflection coefficient at the buffer-couplant-sample interface. The reflection coefficient is examined as a function of the surface roughness and corresponding couplant thickness variations. Interrelations with ultrasonic frequency are illustrated. Reliable attenuation measurements are obtained only when the frequency dependence of the reflection coefficient is incorporated in signal analysis. Data are given for nickel 200 samples and a silicon nitride ceramic bar having surface roughness variations in the 0.3 to 3.0 microns range for signal bandwidths in the 50 to 100 MHz range.

Generazio, E. R.↗

Apparatus for continuous, fast, and precise measurements of position and velocity of a small spherical particle

The position and velocity of optically levitated glass spheres (radii 10-20 microns) movng in a gas are measured accurately, rapidly, and continuously using a high-speed rotating polygon mirror. The experimental technique developed here has repeatable position accuracies better than 20 microns. Each measurement takes less than 1 microsec and can be repeated every 100 microsec. The position of the levitated glass spheres can be manipulated accurately by modulating the laser power with an acoustic optic modulator. The technique provides a fast and accurate method to study general particle dynamics in a fluid.

Venkataraman, T. S.↗

The role of the reflection coefficient in precision measurement of ultrasonic attenuation

Ultrasonic attenuation measurements using contact, pulse-echo techniques are sensitive to surface roughness and couplant thickness variations. This can reduce considerable inaccuracies in the measurement of the attenuation coefficient for broadband pulses. Inaccuracies arise from variations in the reflection coefficient at the buffer-couplant-sample interface. The reflection coefficient is examined as a function of the surface roughness and corresponding couplant thickness variations. Interrelations with ultrasonic frequency are illustrated. Reliable attenuation measurements are obtained only when the frequency dependence of the reflection coefficient is incorporated in signal analysis. Data are given for nickel 200 samples and a silicon nitride ceramic bar having surface roughness variations in the 0.3 to 3.0 microns range for signal bandwidths in the 50 to 100 MHz range.

Generazio, E. R.↗

Redshifts of high-temperature emission lines in the far-ultraviolet spectra of late-type stars. II - New, precise measurements of dwarfs and giants

Results are presented from an IUE SWP camera investigation of the occurrence of gasdynamic flows, analogous to the downdrafts of 10 to the 5th K material observed over magnetic active regions of the sun, among stars of late spectral type. The SWP calibration spectra study conducted documents the existence of local, small, persistent distortions of the echelle wavelength scales that are of unknown origin. Attention is given to the enormous widths of the stellar high-excitation emission lines in both the dwarfs and the giants, with respect to the comparatively small, subsonic Doppler shifts; the widths are typically an order of magnitude greater than the redshifts.

Ayres, Thomas R.↗

Precise measurement of asteroid sizes and shapes from occultations

The observational techniques (including photoelectric observations, television recordings, and visual timings) used to measure asteroid dimensions from occultations of stars by asteroids are discussed together with the methods of analysis appropriate to occultation data. Results are presented on the determinations of asteroid diameter, density, and internal structure measures learned from occultations of 36 asteroids. Prospects for continued effective applications of the occultation technique to asteroid studies are discussed.

Millis, R. L.↗

A precise measurement of the cosmic microwave background radiation temperature from CN observations toward Zeta Persei

High-SNR high-resolution (R = 150,000-170,000) optical spectra of interstellar CN toward Zeta Per are presented. Fits to the data yield a value of 1.25 + or - 0.02 km/s for the R(O) linewidth parameter b along this line of sight. The column densities of the level populations are directly determined from the convolution of the instrument response function with a model which is then fitted to the data. Tex = 2.79 + or - 0.03 K is obtained along this line of sight.

Kaiser, Mary Elizabeth↗

Precise measurement method for ionospheric total electron content using signals from GPS satellites

A GPS codeless receiver called GTR-2 was for measuring total electron content (TEC) along the line of sight to the GPS satellite by using the cross correlation amplitude of the received P-code signals carried by L1(1575.42 MHz) and L2(1227.6 MHz). This equipment has the performance of uncertainty in the measurement of TEC of about 2 X 10(exp 16) electrons/sq m when a 10 dBi gain antenna was used. To increase the measurement performance, an upper version of GTR-2 called GTR-3 is planned which uses the phase information of the continuous signals obtained by making a cross correlation or multiplication of the received L1 and L2 P-code signals. By using the difference of these measured phases values, the ionospheric delay with the ambiguities of the periods of L1+L2 and L1-L2 signals can be estimated.

Imae, Michito↗

Precision measurement of magnetic characteristics of an article with nullification of external magnetic fields

An apparatus for characterizing the magnetic field of a device under test is discussed. The apparatus is comprised of five separate devices: (1) a device for nullifying the ambient magnetic fields in a test environment area with a constant applied magnetic field; (2) a device for rotating the device under test in the test environment area; (3) a device for sensing the magnetic field (to obtain a profile of the magnetic field) at a sensor location which is along the circumference of rotation; (4) a memory for storing the profiles; and (5) a processor coupled to the memory for characterizing the magnetic field of the device from the magnetic field profiles thus obtained.

Honess, Shawn B.↗

Precise Measurements of the Cosmic Ray Antiproton Spectrum with BESS Including the Effects of Solar Modulation

The Balloon Borne Experiment with a Superconducting Spectrometer (BESS) has measured the energy spectrum of cosmic-ray antiprotons between 0.18 and 4.20 GeV in eight flights between 1993 and 2002. Above about 1 GeV, models in which antiprotons are secondary products of the interactions of primary cosmic rays with the interstellar gas agree with the BESS antiproton spectrum. Below 1 GeV, the data show a possible excess antiproton flux compared to secondary model predictions, suggesting the presence of an additional source of antiprotons. The antiproton/proton ratios measured between 1993 and 1999, during the Sun's positive-polarity phase, are consistent with simple models of solar modulation. However, results from the 2000 flight, following the solar magnetic field reversal, show a sudden increase in the antiproton/proton ratio and tend to favor a charge-sign-dependent drift model. To extend BESS measurements to lower energies, an evolutionary instrument, BESS-Polar, is under construction for polar flight in 2004.

Mitchell, J. W.↗