Grocery Operations to Reduce Risks of Airborne Infectious Disease Transmission
This fact sheet highlights best practices and guidelines around HVAC, refrigeration, and space use for grocery operators.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This fact sheet highlights best practices and guidelines around HVAC, refrigeration, and space use for grocery operators.
This fact sheet highlights best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for retail operators.
This fact sheet examines best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for hotel/motel operators.
This fact sheet highlights best practices and guidelines around HVAC and space use for commercial office operators.
A fact sheet of best practices and guidelines around HVAC, refrigeration, and space use for grocery operators.
A fact sheet of best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for hotel/motel operators.
A fact sheet of best practices and guidelines around HVAC, exhaust systems, BAS, elevators, and space use for retail operators.
A fact sheet of best practices and guidelines around HVAC and space use for commercial office operators.
Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.
Purpose: Evidence for external beam radiation therapy (RT) as part of treatment for retroperitoneal sarcoma (RPS) is limited. Preoperative RT is the subject of a current randomized trial, but the results will not be available for many years. In the meantime, many practitioners use preoperative RT for RPS, and although this approach is used in practice, there are no radiation treatment guidelines. An international expert panel was convened to develop consensus treatment guidelines for preoperative RT for RPS. Methods and Materials: An expert panel of 15 academic radiation oncologists who specialize in the treatment of sarcoma was assembled. A systematic review of reports related to RT for RPS, RT for extremity sarcoma, and RT-related toxicities for organs at risk was performed. Due to the paucity of high-quality published data on the subject of RT for RPS, consensus recommendations were based largely on expert opinion derived from clinical experience and extrapolation of relevant published reports. It is intended that these clinical practice guidelines be updated as pertinent data become available. Results: Treatment guidelines for preoperative RT for RPS are presented. Conclusions: An international panel of radiation oncologists who specialize in sarcoma reached consensus guidelines for preoperative RT for RPS. Many of the recommendations are based on expert opinion because of the absence of higher level evidence and, thus, are best regarded as preliminary. We emphasize that the role of preoperative RT for RPS has not been proven, and we await data from the European Organization for Research and Treatment of Cancer (EORTC) study of preoperative radiotherapy plus surgery versus surgery alone for patients with RPS. Further data are also anticipated pertaining to normal tissue dose constraints, particularly for bowel tolerance. Nonetheless, as we await these data, the guidelines herein can be used to establish treatment uniformity to aid future assessments of efficacy and toxicity.
Purpose: To evaluate the compliance with evidence-based treatment planning organ-at-risk (OAR) guidelines in a single institution with four practice sites. Methods: Two hundred thirteen head and neck cancer patients treated between September 2009 and September 2013 were retrospectively selected. Consensus treatment planning guidelines, including OAR dose constraints, were established based on institutional experience and published data. Data spanned a time period of 2 years prior to (n=112) and 2 years post-enactment (n=101) of the guidelines. We investigated the differences in the frequency with which (1) OARs were contoured and (2) OAR DVH goals were met. Trends in the proportion with OAR contours over time was tested using linear regression. Trends in the proportion of contoured OARs achieving clinical DVH goals were similarly tested. The proportion of patients contoured and meeting DVH goals before and after guidelines was compared using a test of proportions. Results: When the proportion of cases with OAR contours before and after guidelines were compared, we observed an increase from 75% to 87% (p=0.02) for the brainstem, decrease from 97% to 88% (p=0.01) for the cord and increase from 47% to 77% (p<0.001) for the mandible. For the proportion of cases with OAR contours in which clinical goals were met, a significant decrease from 99% to 90% was observed for the cord V48<0.3% (p=0.001). A significant decrease in the proportion of cases with left parotid contours (from 92% to 73% (p=0.03)) was observed over 2 years after guideline enactment and the proportion meeting the clinical DVH goal of V30<50% increased significantly from 36% to 50% (p=0.007) over the 2 years after guidelines. Conclusion: The enactment of OAR planning guidelines resulted in an increase in OAR contour compliance, overall. In cases with OAR contours, there was little to no change in the proportion that met clinical goals.
This Methods/Protocols article is intended for materials scientists interested in performing machine learning-centered research. Herein, we cover broad guidelines and best practices regarding the obtaining and treatment of data, feature engineering, model training, validation, evaluation and comparison, popular repositories for materials data and benchmarking data sets, model and architecture sharing, and finally publication. In addition, we include interactive Jupyter notebooks with example Python code to demonstrate some of the concepts, workflows, and best practices discussed. Overall, the data-driven methods and machine learning workflows and considerations are presented in a simple way, allowing interested readers to more intelligently guide their machine learning research using the suggested references, best practices, and their own materials domain expertise.
The white paper is an effort to draw up a set of CCS costing guidelines in three complementary areas where further guidelines and better practices are needed, and where efforts are underway to address those topics. The first area of study tackles the establishment of improved guidelines for cost evaluation of advanced low-carbon technology (such as a new CO 2 capture process or a novel power plant design). The second area of study focuses on CCS from non-power industries while the final area addresses quality assurance and uncertainty evaluations of data and models used in CCS cost analysis.
Infrastructure interacts with major global challenges inclusive of climate change, resilience, equity and social justice, environmental protection and biodiversity, public health, and economic recovery. This effort directly addresses how to apply sustainability assessments to the unique aspects of hydrogen (H2) infrastructure projects using the Envision® sustainability framework developed by the Institute for Sustainable Infrastructure (ISI). Envision is a flexible system of criteria and performance objectives to aid decision makers and help project teams identify sustainable approaches during planning, design and construction of infrastructure projects that will continue throughout the project’s operations, maintenance, and end-of-life phases. The goal of this work is to support those interested in conducting sustainability assessments for hydrogen infrastructure projects. Through this work the team has developed hydrogen-specific guidelines and best practices to assist project developers, investors and regulators in straightforward application of the Envision framework to systematically enhance clarity and increase objectivity across hydrogen projects. Subject matter experts from 20 different organizations (industry, non-profits, municipalities, emissions regulators, national labs) were engaged through 7 focus groups to discuss the H2-prioritized Envision requirements and elements to be included in the guidelines. In addition to these guidelines, the team conducted case studies as a way of demonstrating and informing the guidelines and providing examples or ideas for implementing sustainability in future projects. Through this study, the authors found that hydrogen infrastructure projects can incorporate many sustainable practices including reducing GHG emissions affecting climate change, reducing air pollutant emissions affecting the health of communities, synergistically handling waste byproducts, integrating into existing infrastructure, incorporating renewable energy, and addressing equity and environmental justice. Additionally, hydrogen infrastructure projects could benefit from 2-way communication engagement and collaborative planning with stakeholders, educational awareness of hydrogen technology, tracking and reporting on water use and water quality, and including monetized environmental and social benefits in life-cycle cost estimates. This document is the final technical report for the Hydrogen Sustainability Assessment Methods for Project Development project. While the main focus of the report is to provide guidelines for applying sustainability to hydrogen infrastructure, there are sections within the appendix providing completed project tasks and methodology.
Members of the Energy Facility Contractors Group (EFCOG), Safeguards and Security Working Group, Information Security Sub-Working Group Incidents of Security Concern (IOSC) Team prepared this best practice guide. For the purposes of this guide, “best practices” are “positive examples of work processes, procedures, good ideas, or effective solutions. The team made up of IOSC Subject Matter Experts (SME) identified these best practices as a result of actual operational experience and training. The guide describes best practices for categorizing incidents and managing inquiries. These practices may serve as guidelines for developing program plans, policy and procedures. These practices are suggestions for Department sites to consider while working in the IOSC subject area. The authors acknowledge that there may be alternatives to the practices identified in this guide. Subject matter Experts from the IOSC program across the Department developed this guide. Extensive discussion and document reviews were conducted to identify best practices relating to security inquiries. It was not within the scope of this study to assess individual site performance or evaluate compliance. Department of Energy’s (DOE), Order 470.4B, Chg.2, Safeguards and Security Program, July-21-2011, Chg 2, January-17-2017, Attachment 5, Incidents of Security Concern, contains the requirements for the IOSC program. In accordance with DOE directives and requirements established by DOE/National Nuclear Security Administration (NNSA) oversight, the working group evaluated elements of the IOSC program at each of the working group member’s sites such as categorizing events, conducting inquiries, and reporting events. Inconsistencies in categorization across the sites may be due to various factors, including each local field office having different reporting expectations, subjectivity in making determinations, and potential inherent deficiencies in the categorization tables and category descriptions. Many sites have adopted a sub reportable category for a security anomaly event that it believes does not meet the criteria as a reportable IOSC. The sites typically establish a local standardized process for reporting, analyzing, and trending sub-reportable events. Security incident program managers may need to discuss inconsistent categorization with other Inquiry Officials (IO) and suggest standardized solutions (ie…through policy changes or a forum attended by incident program managers and inquiry officials to discuss standardization solutions. At least one EFCOG IOSC team member’s site is currently using the best practices identified in this guide.
Purpose: To examine utilization trends of accelerated partial breast irradiation (APBI) in the American College of Surgeons' National Cancer Database and changes in APBI use after the 2009 publication of the American Society for Radiation Oncology (ASTRO) guidelines. Methods and Materials: A total of 399,705 women were identified who were diagnosed from 2004 to 2011 with nonmetastatic invasive breast cancer or ductal carcinoma in situ who were treated with breast-conserving surgery and radiation therapy to the breast. Patients were divided by the type of treatment received (whole breast irradiation or APBI) and by suitability to receive APBI as defined by the ASTRO guidelines. Logistic regression was applied to study APBI use overall and within guideline categorization, and a multivariable model was created to determine predictors of treatment with brachytherapy-based APBI based on guideline categorization. Results: For all patients, APBI use increased, from 3.8% in 2004 to 10.6% in 2011 (P<.0001). Overall rates of APBI utilization were higher among “suitable” than “cautionary”/“unsuitable” patients (14.8% vs 7.1%, P<.0001). The majority of APBI treatment was delivered using brachytherapy, for which use peaked in 2008. Starting in 2009, among “suitable” patients, utilization of APBI via brachytherapy plateaued, whereas for “cautionary”/“unsuitable” patients, treatment with brachytherapy-based APBI declined and then plateaued. Conclusion: Use of APBI across all patient groups increased from 2004 through 2008. After publication of the ASTRO APBI guidelines in 2009, rates of brachytherapy-based APBI treatment plateaued among “suitable” patients and declined and then plateaued among “cautionary”/“unsuitable” patients. Our study highlights how large national databases can be used to assess national trends in radiation use in response to the publication of guidelines.
This article provides a comparison of health impact assessment (HIA) guidelines from around the world and for multiple geographic scales. We identify commonalities and differences within HIA guides to discuss the plausibility of consensus guidelines and to inform guideline development. The practice of HIA has grown over the last two decades with a concurrent growth of HIA guides. This study expands on earlier review work and includes guides published since 2007 (Mindell, Boltong and Forde, 2008). From April 2010 to October 2011, 45 HIA guides were identified through an internet search and review of previous research. Common characteristics, key features, and the HIA process were analyzed. The 45 documents recommended similar but not identical processes for conducting HIAs. These analyses suggest that guidelines for HIAs are similar in many areas of the world and that new HIA practitioners can use these findings to inform their approach. Further discussion is needed to determine if the approaches established in these guidelines are followed and if one set of common guidelines could be written for use in numerous countries and regions. - Highlights: Black-Right-Pointing-Pointer We analyze 45 health impact assessment (HIA) guidelines worldwide. Black-Right-Pointing-Pointer We examine similarities and unique attributes of each guideline. Black-Right-Pointing-Pointer We discuss the advantages and disadvantages of developing consensus guidelines. Black-Right-Pointing-Pointer Identifying additional guidelines aides in future HIA work and evaluation.
Purpose: The objective of this study was to survey the use of reirradiation (Re-RT) for in-field failures after previous radical radiation treatment (RT) among Canadian radiation oncologists (ROs). Methods and Materials: An electronic survey was sent to 271 ROs in Canada. The completed surveys were received electronically via e-mail and the data were analyzed using SAS 9.1.3 software. Results: A total of 183 ROs (67.5%) completed and returned the survey. The majority of the respondents were involved in the practice of either breast (48%) or genitourinary (43%) tumor sites. A total of 49% of the participants were interested in using Re-RT for the management of in-field recurrences. The goals of the therapy would be improvement of quality of life (99%), locoregional control (80%), or cure (32%). Most of the physicians believed that patients should have a minimum Karnofsky performance status of 50 or Eastern Cooperative Oncology Group performance status of 3, a minimum life expectancy of 3 months, and a minimum interval from initial treatment of 3 months if Re-RT were to be given with curative intent. Conclusions: This survey showed that a wide variation existed among ROs in their approach to Re-RT. Newer technologies in RT planning and delivery would be employed to facilitate normal tissue avoidance. The results of this study suggested that a consensus meeting was needed to establish guidelines for the practice and prospective evaluation of Re-RT.