Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Outages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Ten questions concerning reinforcement learning for building energy management

As buildings account for approximately 40% of global energy consumption and associated greenhouse gas emissions, their role in decarbonizing the power grid is crucial. The increased integration of variable energy sources, such as renewables, introduces uncertainties and unprecedented flexibilities, necessitating buildings to adapt their energy demand to enhance grid resiliency. Consequently, buildings must transition from passive energy consumers to active grid assets, providing demand flexibility and energy elasticity while maintaining occupant comfort and health. This fundamental shift demands advanced optimal control methods to manage escalating energy demand and avert power outages. Reinforcement learning (RL) emerges as a promising method to address these challenges. Here, in this paper, we explore ten questions related to the application of RL in buildings, specifically targeting flexible energy management. We consider the growing availability of data, advancements in machine learning algorithms, open-source tools, and the practical deployment aspects associated with software and hardware requirements. Our objective is to deliver a comprehensive introduction to RL, present an overview of existing research and accomplishments, underscore the challenges and opportunities, and propose potential future research directions to expedite the adoption of RL for building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydroclimate-coupled framework for assessing power system resilience under summer drought and climate change

Extreme drought, exacerbated by climate change, increasingly threatens power system resilience, and a systematic assessment of such impacts is challenging due to the unpredictability of drought and their associated modeling complexity. Here, to address the challenge, this research develops a hydroclimate-coupled power system resilience assessment framework that enables systematic modeling of drought and climate change impacts on generation, transmission, and demand sectors. Applying the framework to the 2025 Eastern U.S. power grid — comprising 6,055 at-risk generators — under climate-induced summer drought scenarios (including SSP126, SSP245, SSP370, and SSP585) from 2023 to 2100, the study finds that climate-induced droughts could jeopardize the power system’s reliability to a greater extent than historical events, potentially leading to widespread load shedding. More specifically, the study reveals that under the twenty-one representative drought scenarios, the loss of load expectation (LOLE) of the grid could range from 34.77 to 91.48 days per summer. The simulations indicate that implementing resilience enhancement strategies is crucial to ensure reliable system operation, which encompasses initiatives such as demand response, upgrading open cooling systems, and transmission expansion. In all, these findings underscore the urgent need for proactive planning and investment in resilient U.S. power systems to mitigate the impacts of extreme drought events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ambient energy for buildings: Beyond energy efficiency

The following Key Messages comprise the salient findings of this study: 1. Ambient energy (from sun, air, ground, and sky) can heat and cool buildings; provide hot water, ventilation and daylighting; dry clothes; and cook food. These services account for about three-quarters of building energy consumption and a third of total US demand. Biophilic design (direct and indirect connections with nature) is an intrinsic adjunct to ambient energy systems, and improves wellness and human performance. 2. The current strategy of electrification and energy efficiency for buildings will not meet our climate goals, because the transition to an all-renewable electric grid is too slow. Widespread adoption of ambient energy is needed. Solar-heated buildings also flatten the seasonal demand for electricity compared to all-electric buildings, reducing required production capacity and long-term energy storage. In addition, ambient-conditioned buildings improve resilience by remaining livable during power outages. 3. National policies, incentives, and marketing should be enacted to promote ambient energy use. Federal administrative priorities should reflect the importance of ambient energy for buildings. Use of ambient energy should be encouraged through existing and new building codes and standards. 4. Ambient energy system design tools are needed for architects, engineers, builders, building scientists, realtors, appraisers, and consumers. PVWatts is used over 100 million times per year for photovoltaic system design. A similar, simple, and accessible tool for ambient design is crucial. 5. Training on ambient energy is needed throughout secondary, post-secondary, and continuing education for workforce development. Currently, only about 10% of colleges teach courses on passive heating and cooling systems. 6. Ambient-conditioned buildings should be demonstrated in all US climate zones. Performance should be monitored and reported, with quantitative case studies made widely available. 7. While current technology is sufficient to build high-performance ambient buildings now, research is needed to develop new technologies to harness ambient energy more effectively and more economically. Such advancements will facilitate adoption of ambient energy technologies in a wider range of buildings, including retrofits. Examples include windows with much lower thermal losses, use of the building shell as thermal storage, alternative light-weight thermal storage systems, sky radiation cooling systems, automated controls for solar gains and passive cooling, and ground coupling.

14 SOLAR ENERGY↗

Engineering bimetallic interfaces and revealing the mechanism for carbon dioxide electroreduction to C 3+ liquid chemicals

Reduction reaction of CO 2 (CO 2 RR) to liquid C 3+ chemicals is a net-zero-carbon process and can increase local resiliency to power outages and fuel consumption. The mechanism and the catalyst design rules of CO 2 RR-to-C 3+ are unknown. Engineering bimetallic interface (e.g., Pd/Au) to tune the intermediate adsorption is promising for promoting C 3+ formation. Our density functional theory (DFT) calculations find that *CH 2 could be the key intermediate and C 1 -CH 2 coupling could be the rate-limiting step to generate C 3+ . High CO surface coverages can promote the bimetallic interfacial sites, lower the energetics of the C 1 -CH 2 coupling step, and enhance the C 3+ formation. We further construct a volcano plot of C 1 -CH 2 kinetics as a function of the binding strength of key intermediate *CH 2 via engineering the d-band center of the interfacial site. Our findings could guide the rational design of bimetallic interfaces and their near-surface microenvironment for enhancing CO 2 RR-to-C 3+ .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of the Lanthanum hexaboride based plasma source for the large plasma device at UCLA

The Large Plasma Device (LAPD) at UCLA (University of California, Los Angeles) produces an 18 m long, magnetized, quiescent, and uniform plasma at a high repetition rate to enable studies of fundamental plasma physics. Here, we report on a major upgrade to the LAPD plasma source that allows for more robust operation and significant expansion of achievable plasma parameters. The original plasma source made use of a heated barium oxide (BaO) coated nickel sheet as an electron emitter. This source had a number of drawbacks, including a limited range of plasma density (≲4.0 × 10 12 cm −3 ), a limited discharge duration (∼10 ms), and susceptibility to poisoning following oxygen exposure. Further, the new plasma source utilizes a 38 cm diameter lanthanum hexaboride (LaB 6 ) cathode, which has a significantly higher emissivity, allowing for a much larger discharge power density, and is robust to exposure to air. Peak plasma density of up to 3.0 × 10 13 cm −33 in helium gas has been achieved. The typical operating pressure is ∼10 −5 Torr, while dynamic pressure can be achieved through the gas-puffing technique. Discharges as long as 70 ms have been produced, enabling a variety of long-time-scale studies of processes, such as turbulent particle transport. The new source has been in continuous operation for 14 months, having survived air leaks, power outages that led to rapid temperature changes on the cathode and heater, and planned machine openings. We describe the design, construction, and initial operation of this novel new large-area LaB6 plasma source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Occupant-Centric key performance indicators to inform building design and operations

Building performance indicators are widely used to guide building design and track and benchmark operational performance. Traditional building performance indicators mostly focus on the energy efficiency perspective. As occupants are the primary building service recipients in residential and most commercial buildings, their comfort and wellbeing are crucial. As such, this study first identified significant attributes of occupant-centric key performance indicators (KPIs) and analyzed the diverse factors that should be considered in formulating an occupant-centric KPI. Then a suite of occupant-centric KPIs were synthesized from the review and enhancement of existing occupant-related performance metrics. The proposed occupant KPIs represent the occupant lens on three integrative aspects of building performance: resource use (including energy and water), indoor environmental quality, and human–building interactions. A simulation-based case study was conducted to demonstrate how occupant-centric KPIs can be used to quantify the impacts of building operation changes from the occupants’ point of view. Highlights: Occupant-centric metrics are currently ad hoc and limited, yet crucial to inform building design and operations. Literature was reviewed to reveal the state-of-the-art and gaps of occupant-centric metrics. A suite of occupant-centric key performance indicators (KPIs) covering five groups of building services were synthesized. Proposed occupant KPIs represent three aspects of performance: resource use and demand, occupant comfort and health, and human–building interactions. A case study using whole building simulation was conducted to demonstrate the use of occupant-centric KPIs in evaluating building operations during a power outage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Near-Real-Time Model for Predicting Electricity Disruptions in Texas During Winter Storms

There has been an increase in extreme weather events, posing a threat to power grid systems, potentially influenced by factors such as population growth, changes in ecosystems, land cover, and land use in the service area, as well as the growth of certain vegetation types. This research seeks to develop a predictive model to mitigate potential damages caused by future winter storms. This research utilizes the Light Gradient Boosting Machine (LightGBM), incorporating the number of power outages experienced at the county level, geographic details, weather information, and lagged outage and lagged weather data. The developed models were broadly divided into two groups, with six models in each group - one group without optimization and another with optimization, totaling 12 trained models. For model optimization, Bayesian optimization was employed using Root Mean Squared Error (RMSE) as the objective function. In results, when comparing Group 2 (the optimized group) with Group 1 (the non-optimized group), it was found that optimization did not always lead to a reduction in RMSE and Mean Absolute Error (MAE). However, in terms of Mean Directional Accuracy (MDA), while all results in Group 1 were below the baseline accuracy of 0.33, all results in Group 2 exceeded 0.33, with some cases showing an increase of more than three times the baseline. The results indicated that, in the optimized model group, Population and Pressure were the most influential factors when using current weather data and geographical information. When using lagged data, lagged recorded outages and lagged Pressure emerged as the most significant factors. Among the 12 developed models, the L-1-2-O model showed the lowest RMSE and MAE, as well as the highest accuracy, with values of 390.62 households and 168.13 households, respectively. To normalize the RMSE and MAE values, each metric was divided by the average number of households among the counties in Texas. For the L-1-2-O model, the scaled RMSE was 0.88% and the scaled MAE was 0.38%. In terms of MDA, which indicates the accuracy of the prediction direction, the L-1-O model achieved the highest score of 0.41. Although this study focused on Texas, which suffered the greatest impact from the winter storms in 2021, with additional validation, the methodology used in this research could be applied to other regions.

Lee, Jangjae [Texas A & M Univ., College Station, ↗

HexWeather: Hexagonal Spatial Data Aggregation for Weather-Driven Grid Resilience Analysis

Extreme weather accounts for over 8 0 % of major U.S. power outages since 2000, highlighting the need for spatial tools that align weather data with the irregular boundaries of electric infrastructure. This paper introduces HexWeather, a modular, resolution-aware framework for aggregating historical and forecasted weather data using Uber's H3 hexagonal spatial indexing system. Unlike traditional methods that rely on state or county-level grids, HexWeather enables weather analysis across custom geographies such as utility service areas where public datasets are often unavailable or misaligned. Using Open-Meteo data, we evaluate how H3 resolution affects anomaly detection, spatial variability, and forecast uncertainty across three scales: state, county, and utility. Results show that while coarse resolutions suffice for broad trend tracking, finer resolutions are essential for identifying localized variability and operational risks. By applying metrics like Z-score standard deviation and interquartile range, HexWeather quantifies the spatial spread of both historical anomalies and forecasted conditions, allowing users to assess resolution adequacy for each analysis. This framework supports rapid weather data reuse, reproducible anomaly detection, and predictive modeling for infrastructure resilience. By bridging spatial misalignment in traditional datasets and enabling retrospective and forward-looking analysis within the same pipeline, HexWeather lays the groundwork for better post event analysis, outage prediction, and resilience planning.

Morris, Jacob [ORNL]↗

Control of Behind-the-Meter Resources for Enhancing the Resilience of Residential Buildings

There is increased concern about the impacts of frequent power outages, caused primarily by extreme weather conditions. With increasing behind-the-meter resources such as solar photovoltaics (PV), battery energy storage, and controllable loads, these resources - if properly coordinated - can meet critical loads even during an outage. Resilience building controls can coordinate and operate these resources to enhance the resiliency of buildings supporting critical loads for longer duration. In this paper, we present two resilience building controls: rule-based control and model predictive control (MPC). We simulated various scenarios considering different locations, seasons, outage types, and times of outages to evaluate the performance of resilience controls. The results show that MPC-based control can enhance resilience up to 65% compared to rule-based control. Similarly, PV self-consumption and occupant thermal comfort both increase during outages with MPC-based control.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Techno-Economic Analysis of Data-Driven and Transactive Approaches for Resilience Enhancement

As extreme weather events lead to more frequent power outages, understanding and enhancing grid resilience is critical to mitigating economic losses and non-energy impacts from service disruptions. Here, this study introduces a novel techno-economic analysis framework for evaluating resilience enhancement mechanisms. The framework combines grid response modeling with a co-simulation approach and valuation methodology to provide a comprehensive assessment. We apply this framework to a realistic case study of the Texas grid during Winter Storm Uri in February 2021. Two advanced resilience strategies are analyzed: a data-driven rolling outage mechanism and a transactive energy (TE) based allocation scheme. The rolling outage scheme selectively serves customers based on real-time curtailment needs, while the TE scheme allows customers to trade energy allocations according to their preferences. Our findings show that both the rolling outage and TE schemes significantly outperform conventional methods (i.e. controlled outages) by reducing the amount of energy not supplied to customers by 41% and 64%, respectively. These approaches also enhance flexibility and customer satisfaction, while improving energy utilization for greater resilience. Additionally, they maintain thermal comfort about 3.5 times better and substantially lower customer risk exposure. A key contribution of this study is addressing both utility and customer perspectives while considering both energy and non-energy impacts. The techno-economic analysis indicates that implementing these resilience enhancement strategies would incur an additional 1.1Bto1.6B in utility costs but has the potential to avoid 17.3Bto18B of customer losses as compared to existing solutions, thereby underscoring the value of investing in advanced resilience, as it provides significant societal benefits to customers.

42 ENGINEERING↗

Contingency Analysis Based on Partitioned and Parallel Holomorphic Embedding

In the steady-state contingency analysis, the traditional Newton-Raphson method suffers from non-convergence issues when solving post-outage power flow problems, which hinders the integrity and accuracy of security assessment. In this paper, we propose a novel robust contingency analysis approach based on holomorphic embedding (HE). Here, the HE-based simulator provides theoretical convergence guarantee, which is desirable because it avoids the influence of numerical issues and provides a credible security assessment conclusion. In addition, based on the multi-area characteristics of real-world power systems, a partitioned HE (PHE) method is proposed with an interfacebased partitioning of HE formulation. The PHE method does not undermine the numerical robustness of HE and significantly reduces the computation burden in large-scale contingency analysis. The PHE method is further enhanced by parallel or distributed computation to become parallel PHE (P2HE). Tests on a 458-bus system, a synthetic 419-bus system and a large-scale 21447-bus system demonstrate the advantages of the proposed methods in robustness and efficiency.

42 ENGINEERING↗

Special Issue: Thermal Energy Storage for Buildings

This special issue (SI) of the ASME Journal of Engineering for Sustainable Buildings and Cities (JESBC) features peer-reviewed papers specific to technologies and applications of thermal energy storage (TES) for buildings. TES systems store energy in materials as a heat source or a cold sink and then discharge the stored energy hours or weeks later to enhance thermal comfort or reduce utility bills [1]. As buildings and cities are facing increasing energy consumption and extreme weather events, TES offers a powerful solution to balance supply and demand, reduce operational energy costs, and strengthen energy resilience during power outages.

25 ENERGY STORAGE↗

Water Network Tool for Resilience (WNTR)

The Water Network Tool for Resilience (WNTR) is an open source Python package designed to simulate and analyze resilience of water distribution networks. The United States Environmental Protection Agency, in partnership with Sandia National Laboratories, developed WNTR to integrate critical aspects of resilience modeling for water distribution networks into a single software framework. The software includes capability to: • Generate water network models • Modify network structure and operations • Assign fragility and survival curves to network components • Model disruptive events such as power outages, earthquakes, fires, pipe breaks, and contamination incidents • Model response and repair strategies • Simulate hydraulics and water quality • Evaluate resilience using a wide range of metrics • Integrate dependency with other critical infrastructure and supply chains • Analyze results and generate graphics SAND2019-450 M

Villa, Daniel↗

Hybrid-RL-MPC4CLR (Hybird-Reinforcement-Learning-Model-Predictive-Control-for-Reserve-Policy-Assisted-Critical-Load-Restoration-in-Distribution-Grids)

Hybrid-RL-MPC4CLR was developed as a hybrid controller for active distribution grid critical load restoration, combining deep reinforcement learning (RL) and model predictive control (MPC) aiming at maximizing total restored load following an extreme event. The RL determines a policy for quantifying operating reserve requirements, thereby hedging against uncertainty, while the MPC models grid operations incorporating the RL policy actions (i.e., reserve requirements), renewable (wind and solar) power predictions, and load demand forecasts. The developers formulated the reserve requirement determination problem as a sequential decision-making problem based on the Markov Decision Process (MDP) and design an RL learning environment based on the OpenAI Gym framework and MPC simulation. The RL agent reward and MPC objective function aim to maximize and monotonically increase total restored load and minimize load shedding and renewable power curtailment. The software is developed using various software packages in Python. The MPC's optimal power flow (OPF) model is implemented using the Pyomo package, the RL simulation environment is implemented using the MPC simulation with various scenarios of renewable energy and load demand profiles and power outage beginning times, based on the OpenAI Gym framework. The RL agent training is performed using the RLlib Ray package. The RL algorithm is trained offline using historical forecasts of renewable generation and load demand profiles. Simulation analysis and performance tests are conducted using a modified IEEE 13-bus distribution test feeder containing wind turbine, photovoltaic, microturbine, and battery.

Eseye, Abinet Tesfaye↗

Dynamic Transmission Line Switching Amid Wildfire-Prone Weather Under Decision-Dependent Uncertainty

During dry and windy seasons, environmental conditions significantly increase the risk of wildfires, exposing power grids to disruptions caused by transmission line failures. Wildfire propagation exacerbates grid vulnerability, potentially leading to prolonged power outages. To address this challenge, we propose a multistage optimization model that dynamically adjusts transmission grid topology in response to wildfire propagation, aiming to develop an optimal response policy. By accounting for decision-dependent uncertainty, where line survival probabilities depend on usage, we employ distributionally robust optimization to model uncertainty in line survival distributions. We adapt the stochastic nested decomposition algorithm and derive a deterministic upper bound for its finite convergence. To enhance computational efficiency, we exploit the Lagrangian dual problem structure for a faster generation of Lagrangian cuts. Using realistic data from the California transmission grid, we demonstrate the superior performance of dynamic response policies against two-stage alternatives through a comprehensive case study. In addition, after solving the multistage formulation, we construct easy-to-implement policies that significantly reduce computational burden while maintaining good performance in real-time deployment. History: Accepted by Russell Bent, Area Editor for Network Optimization: Algorithms and Applications. Funding: This work was supported by the U.S. Department of Energy, Office of Electricity [Grant DE-AC02-05CH11231]. The work of R. Jiang was supported in part by the U.S. National Science Foundation, Division of Electrical, Communications and Cyber Systems [Grant ECCS-1845980] and the U.S. Air Force Office of Scientific Research [Grant FA9550-23-1-0323]. Supplemental Material: The software that supports the findings of this study is available within the paper and its Supplemental Information ( https://pubsonline.informs.org/doi/suppl/10.1287/ijoc.2025.1210 ) as well as from the IJOC GitHub software repository ( https://github.com/INFORMSJoC/2025.1210 ). The complete IJOC Software and Data Repository is available at https://informsjoc.github.io/ .

Estrada-Garcia, Juan-Alberto↗

Soil water content, matric potential, carbon dioxide and oxygen concentrations, Oct 2018-Dec 2021, Slate River Floodplain, Crested Butte, Colorado

This data package includes a time series of soil sensor data (temperature, water content, bulk electrical conductivity, porewater dissolved oxygen and porewater dissolved carbon dioxide) in a vertical profile from the Slate River floodplain outside Crested Butte, Colorado, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The package includes: (1) soil temperature, volumetric water content and electrical conductivity at 40, 60 and 82.5 cm depth; (2) soil matric potential at 40, 60, 79 and 100 cm depth; (3) soil CO2 concentrations at 40, 60 and 82.5 cm depth; and (4) soil oxygen concentrations at 60, 82.5, 100, 135, 170 and 182 cm depth. Both the carbon dioxide and oxygen sensors are optical sensors that can measure the partial pressure of oxygen in both saturated and unsaturated conditions. Unfortunately, soil CO2 in the profile is unexpectedly high and above the sensor calibration range (0-25,000 ppm). In addition, soil CO2 sensors failed within a year of deployment, so we only report CO2 data from 2019-2020.Within the data package, "FLMD.csv" describes file-level metadata and "dd.csv" defines column headers and universal terms across the dataset. The data package includes 4 "*data.csv" files, one for each calendar year in the dataset. Each "*data.csv" file has a corresponding "*_InstallationMethods.csv" file that describes the location, sensor model, sensor serial number and other metadata corresponding for each measured parameter. Because sensors have been added over time, not every sensor has data dating back to Oct 2018. Note that there is a data gap over winter 2019-2020 due to a power outage. While this repository currently only contains data through December 2021, the dataset will be updated as additional years are collected and processed.

54 ENVIRONMENTAL SCIENCES↗