Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Portal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Portal Monitor Future Development Work: Hardware Improvements

LANL portal monitor was a modification of a previously installed (permanent) unattended monitoring system (UMS). Modifications to the UMS to make the portal were sometimes based on mistaken assumptions about exercise-specific installation and access. Philosophical approach to real-time portal differs in some areas from UMS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Minimum Detectable Quantity Calculation for Radiation Portal Monitors

The minimum detectable quantity of a radiation portal monitor is the smallest amount of radioactive material that can be detected passing through the monitor (with a specified detection probability). The minimum detectable quantity is a function of many factors, including isotope, velocity, distance between pillars, height of portal and vehicle, source distribution and position, background radiation, background suppression, detector volume and positions, detector efficiency, decision metrics and algorithms, the presence of NORM (naturally occurring radioactive material), and alarm thresholds. Experimentally testing a radiation portal monitor to failure for all combinations of these factors is extremely time-consuming and often cost prohibitive. This document outlines a straightforward method for quickly estimating the minimum detectable quantity for moving sources over a large variety of conditions with a minimal number of static measurements. The document also describes a proof of concept software application that the International Atomic Energy Agency has designed based on the described method that can be used by Member States to estimate a monitor’s minimum detectable quantity.

Blessinger, Christopher S.↗

Search for Low mass Higgs Portal Scalars at the MicroBooNE Detector in the NuMI Beam

The MicroBooNE experiment exploits Liquid Argon Time Projection Chamber (LArTPC) technology to detect neutrinos from two beams at Fermilab, Chicago: on-axis Booster Neutrino Beam (BNB) and the off-axis Neutrinos at the Main Injector (NuMI) beam. While the aim of the experiment is to study the low-energy excess of electron neutrino events observed by the MiniBooNE experiment, to search for eV-scale sterile neutrinos and to characterise neutrino interactions on argon, it could also be exploited to probe Beyond Standard Model (BSM) Physics. This thesis presents a BSM search for low-mass Higgs Portal Scalars at MicroBooNE in the NuMI beam using data collected during the Run 1 and Run 3 data-taking periods with a total exposure corresponding to $7.01 \times 10^{20}$ protons on target (POT). The Higgs Portal Model is an extension to the Standard Model in which a dark-sector scalar, $S$, mixes with the Higgs boson with mixing angle $\theta$ and acquires a coupling to the Standard Model fermions via the Higgs Yukawa coupling. We search for low-mass Higgs Portal scalars, in the mass range $100-200$ MeV, at MicroBooNE via the production channel $K \rightarrow \pi + S$, where scalars are produced from kaons decaying at rest in the NuMI target and beam dump, as well as kaons decaying in flight in the decay pipe of the NuMI beam. In the MicroBooNE detector, we search for the decay channel $S \rightarrow e^+e^-$, which is the only decay channel available to the scalars in the mass range of our search. The results are expressed as limits, at the 95\% confidence level, on the scalar-Higgs mixing angle $\theta$ for scalars in the mass range $100-200$ MeV.Date of Award1 Aug 2023Original languageEnglishAwarding InstitutionThe University of ManchesterSupervisorStefan Soldner-Rembold (Supervisor) & Justin Evans (Supervisor)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic liquid scintillation detector shape and volume impact on radiation portal monitors

We have developed and tested a radiation portal monitor using organic liquid scintillation detectors. In order to optimize our system designs, neutron measurements were carried out with three organic liquid scintillation detectors of different shapes and sizes, along with a 3 He radiation portal monitor (RPM) as a reference. The three liquids tested were a 7.62 cm diameter by 7.62 cm length cylindrical active volume organic liquid scintillation detector, a 12.7 cm diameter by 12.7 cm length cylindrical active volume organic liquid scintillation detector, and a 25 cm by 25 cm by 10 cm “paddle” shaped organic liquid scintillation detector. Background and Cf-252 neutron measurements were recorded to allow for a comparison of neutron intrinsic efficiencies as well as receiver operating characteristics (ROC) curves between detectors. The 12.7 cm diameter cylindrical active volume organic liquid scintillation detector exhibited the highest intrinsic neutron efficiency (54%) of all three liquid scintillators. An ROC curve analysis for a heavily moderated Cf-252 measurement showed that using the 12.7 cm diameter by 12.7 cm length cylindrical active volume Eljen EJ309 organic liquid scintillation detector would result in the fewest needed detector units in order to achieve a near 100% positive neutron alarm rate while maintaining a better than 1 in 10,000 false alarm rate on natural neutron background. As a result, a small number of organic liquid scintillation detectors could therefore be a valid alternative to 3 He in some RPM applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital Rocks Portal (Digital Porous Media): Connecting data, simulation and community

Digital Rocks Portal (DRP, https://www.digitalrocksportal.org) organizes and preserves imaged datasets and experimental measurements of porous materials in subsurface, and beyond, with the mission to connect them to simulation and analysis, as well as educate the research community. We have over 150 projects represented in more than 200 publications, and an active community that reuses the data, most recently in multiple machine learning applications for automating image analysis as well as the prediction of transport. Such automation is crucial for performing formation evaluation tasks in near-real time. We present benchmark datasets that have played a role in recent machine learning prediction successes in the field. We further discuss the vision for further research advances, educational materials, as well as growth and sustainability plan of this digital rock physics community resource. In particular, we are in the process of expanding into a broader repository of engineered porous materials, specifically those for energy storage and the portal will transition to Digital Porous Media (DPM) in near future.

58 GEOSCIENCES↗

Performance of High Stopping Power Bismuth-Loaded Plastic Scintillators for Radiation Portal Monitors

Plastic scintillators are widely used in radiation portal monitors because of their low cost and availability in large sizes. However, due to their low density and low effective atomic number (Z), they offer low intrinsic efficiency and little spectroscopic information. The addition of high-Z constituents to these plastics can greatly increase both their total stopping power and the amount of photoelectric absorption, leading to full-energy deposition and thus useful gamma spectra. Herein, we present the performance of the latest formulation of Bi-loaded plastic scintillators showing their useful spectroscopic information up to relatively high energy (~1 MeV) due to their high stopping power compared to the current commercially available plastics. These Bi-loaded plastics use 20 weight percent (wt%) Bi-pivalate (8 wt% elemental Bi) dissolved in polyvinyltoluene (PVT) matrix and conventional fast fluors (~10 ns decay time). These Bi-loaded plastics achieve up to approximately 6000 photons/MeV and have been produced in sizes up to 17 in 3 . The performance of these Bi-loaded plastics is also demonstrated in the existing portal monitor hardware (Rapiscan Model TSA Trainer 770) showing the possibility to provide improved sensitivity as a drop-in replacement with continued scale-up.

42 ENGINEERING↗

Prospects for discovery and spin discrimination of dark matter in Higgs portal DM models and their extensions at 100 TeV $pp$ collider

We study the discovery and discriminating prospects of the Higgs portal dark matter (DM) models for scalar, fermion and vector DM and their extensions in proton–proton (pp) collisions. The $t\bar{t}$+DM associated production in dileptonic final states is considered, in which the stransverse mass of two leptons is found to be effective in suppressing the Standard Model backgrounds along with the missing transverse energy and the angle between two leptons. The distributions of missing transverse energy and polar angle between two leptons are used for a discrimination of the spin nature of DM. For the proposed benchmark points, the discovery/exclusion can be made with an integrated luminosity less than 1 ab -1 given a 1% systematic uncertainty, while the spin discrimination require integrated luminosity of a few O(10) ab -1 given a 0.5% systematic uncertainty. The DM phenomenology is also discussed. A consistent DM candidate can be obtained either by extending our model where the Higgs portal couples to excited dark states that decay into DM, or modifying the coupling form into pseudoscalar.

100 TeV pp collider↗

Framework Development Supporting the Safety Portal

In a collaborating scientific research arena it is important to have an environment where analysts have access to a shared repository of information, documents, and software tools, and be able to accurately maintain and track historical changes in models. The new Safety Portal cloud-based environment will be accessible remotely from anywhere regardless of computing platforms given that the platform has available Internet access and proper browser capabilities. Information stored at this environment would be restricted based on user assigned credentials. This report discusses current development of a cloud-based web portal for PRA tools.

97 MATHEMATICS AND COMPUTING↗

Prenatal Ultrasound Analysis of Umbilical‐Portal‐Systemic Venous Shunts Concurrent With Trisomy 21

Objectives A classification termed umbilical‐portal‐systemic venous shunt (UPSVS) for an abnormal umbilical vein (UV), portal vein (PV), and ductus venosus (DV) was proposed recently. According to this classification, there are 3 types of UPSVSs: types I, II, and III. Trisomy 21 associated with UV‐PV‐DV anomalies has been described, but the incidence of trisomy 21 in UPSVS cases, the relationship between UPSVS types and trisomy 21, and the pregnancy outcome are poorly documented. This study aimed to address these issues. Methods All UPSVS cases diagnosed at our department from 2016 to 2019 were retrospectively studied. The English literature describing UV‐PV‐DV anomalies and trisomy 21 from 2000 to 2019 was searched, and the retrieved cases were analyzed. Results Four of 20 UPSVS cases identified by us also had trisomy 21, with 2 type I and 2 type II UPSVSs. Ultrasound markers of Down syndrome were observed in all 4 cases that underwent termination of pregnancy (TOP). The literature search retrieved 12 reports including 279 patients, with 29 also having trisomy 21, giving a pooled trisomy 21 incidence rate of 10.4%. Of the 29 cases, 16 had type I, and 9 had type II, whereas UPSVS types in 4 were undeterminable, and 22 cases underwent TOP. Conclusions There is a high incidence of trisomy 21 in UPSVS cases. Trisomy 21 is associated with a type I or II UPSVS. Most cases with the combined defect underwent TOP. These findings may be used to direct prenatal counseling and management of the combined condition.

Dong, Xiangyi↗

Nonstandard Yukawa couplings and Higgs portal dark matter

We study the implications of non-standard Higgs Yukawa couplings to light quarks on Higgs-portal dark matter phenomenology. Saturating the present experimental bounds on up-quark, down-quark, or strange-quark Yukawa couplings, the predicted direct dark matter detection scattering rate can increase by up to four orders of magnitude. The effect on the dark matter annihilation cross-section, on the other hand, is subleading unless the dark matter is very light — a scenario that is already excluded by measurements of the Higgs invisible decay width. We investigate the expected size of corrections in multi-Higgs-doublet models with natural flavor conservation, the type-II two-Higgs-doublet model, the Giudice-Lebedev model of light quark masses, minimal flavor violation new physics models, Randall-Sundrum, and composite Higgs models. We find that an enhancement in the dark matter scattering rate of an order of magnitude is possible. In conclusion, we point out that a discovery of Higgs-portal dark matter could lead to interesting bounds on the light-quark Yukawa couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pseudoscalar portal dark matter and new signatures of vector-like fermions

Fermionic dark matter interacting with the Standard Model sector through a pseudoscalar portal could evade the direct detection constraints while preserving a WIMP miracle. Here, we study the LHC constraints on the pseudoscalar production in simplified models with the pseudoscalar either dominantly coupled to b quarks or ${{\tau}}$ leptons and explore their implications for the GeV excesses in gamma ray observations. We also investigate models with new vector-like fermions that could realize the simplfied models of pseudoscalar portal dark matter. Furthermore, these models yield new decay channels and signatures of vector-like fermions, for instance, bbb; b${{\tau}}$ ${{\tau}}$, and ${{\tau}}$ ${{\tau}}$ ${{\tau}}$ resonances. Some of the signatures have already been strongly constrained by the existing LHC searches and the parameter space fitting the gamma ray excess is further restricted. Conversely, the pure ${{\tau}}$-rich final state is only weakly constrained so far due to the small electroweak production rate.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chronic Portal Vein Thrombosis After Liver Transplantation in a Child Treated by a Combined Minimally Invasive Approach

Portal vein thrombosis (PVT) after orthotopic liver transplantation is an infrequent complication, and when it is present surgical treatment is considered for traditional management. Percutaneous transhepatic portal vein angioplasty has been described as an option to treat PVT with a lower morbidity than conventional surgical treatments. This article describes a case of chronic PVT in a child after a living donor liver transplantation managed by percutaneous transhepatic and surgical approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transradial Approach for Transcatheter Selective Superior Mesenteric Artery Urokinase Infusion Therapy in Patients with Acute Extensive Portal and Superior Mesenteric Vein Thrombosis

The purpose of this investigation was to assess the feasibility and effectiveness of transradial approach for transcatheter superior mesenteric artery (SMA) urokinase infusion therapy in patients with acute extensive portal and superior mesenteric venous thrombosis. During a period of 7 years, 16 patients with acute extensive thrombosis of the portal (PV) and superior mesenteric veins (SMV) were treated by transcatheter selective SMA urokinase infusion therapy by way of the radial artery. The mean age of the patients was 39.5 years. Through the radial sheath, a 5F Cobra catheter was inserted into the SMA, and continuous infusion of urokinase was performed for 5-11 days (7.1 {+-} 2.5 days). Adequate anticoagulation was given during treatment, throughout hospitalization, and after discharge. Technical success was achieved in all 16 patients. Substantial clinical improvement was seen in these 16 patients after the procedure. Minor complications at the radial puncture site were observed in 5 patients, but trans-SMA infusion therapy was not interrupted. Follow-up computed tomography scan before discharge demonstrated nearly complete disappearance of PV-SMV thrombosis in 9 patients and partial recanalization of PV-SMV thrombosis in 7 patients. The 16 patients were discharged 9-19 days (12 {+-} 6.0 days) after admission. Mean duration of follow-up after hospital discharge was 44 {+-} 18.5 months, and no recurrent episodes of PV-SMV thrombosis developed during that time period. Transradial approach for transcatheter selective SMA urokinase infusion therapy in addition to anticoagulation is a safe and effective therapy for the management of patients with acute extensive PV-SMV thrombosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Portal Vein Embolization Tailored to Prepare the Liver for Complex Resections: Initial Experience

The purpose of this study was to evaluate the safety and efficacy of preoperative portal vein embolization (PVE) tailored to prepare the liver for complex and extended resections. During the past 5 years, 12 PVEs were performed in noncirrhotic patients with liver metastases from colon cancer (n = 10), choroidal melanoma (n = 1), and leiomyosarcoma (n = 1) to prepare complex anatomical liver resections in patients with small future remnant livers. These liver resections planned to preserve only segment IV in four patients, segments IV, V, and VIII in four patients, segments II, III, VI, and VII in three patients, and segments V and VI in one patient. PVE was performed under general anesthesia with a flow-guided injection of a mixture of cyanoacrylate and Lipiodol using a 5-Fr catheter. All portal branches feeding the liver segments to be resected were successfully embolized with cyanoacrylate except one, which was occluded with coils due to the risk of reflux with cyanoacrylate. After a mean of 32 days, CT volumetry revealed a mean hypertrophy of the unembolized liver of 47 {+-} 25% (range, 21-88%). Liver resections could be performed in 10 patients but were canceled in 2, due to the occurrence of a new hepatic tumor in one and an insufficiently increased volume in the other. Among the 10 patients who underwent the liver resection, 1 died of postoperative sepsis, 3 died 3 to 32 months after surgery, including 1 death unrelated to cancer, and 6 were alive after 6 to 36 months after surgery. In conclusion, in this preliminary report, PVE appears to be feasible and able to induce hypertrophy of the future remnant liver before a complex and extended hepatectomy. Further evaluation is needed in a larger cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Foam Sclerotherapy Using Polidocanol (Aethoxysklerol) for Preoperative Portal Vein Embolization in 16 Patients

Purpose: To evaluate the clinical safety and effectiveness of foam sclerotherapy using polidocanol for preoperative portal vein embolization (PVE) before hemihepatectomy of the liver. Materials and Methods: From March 2006 to October 2008, foam sclerotherapy using polidocanol was performed in 16 patients (male-to-female ratio of 12:4, age range 48-75 years [mean 62]) for PVE. Patients were diagnosed with Klatskin tumor (n = 13), gallbladder (GB) cancer (n = 2), or hepatocellular carcinoma (HCC) (n = 1). The foam was composed of a 1:2:1 ratio of 3% polidocanol (Aethoxysklerol; Kreussler Pharma, Wiesbaden, Germany), room air, and contrast media (Xenetix 350; Guerbet, Aulnay-Sous-Bois, France). The total amount of polidocanol used (2 to 8 mL [mean 4.6]) varied according to the volume of the target portal vein. We calculated the volume of future liver remnant (FLR) before and after PVE and evaluated complications associated with the use of polidocanol foam sclerotherapy for PVE. Results: Technical success was achieved in all patients. All patients were comfortable throughout the procedure and did not experience pain during sclerotherapy. No periprocedural morbidity or mortality occurred. Patients underwent a liver dynamic computed tomography (CT) scan 2-4 weeks after PVE. FLR increased significantly after PVE using polidocanol foam from 19.3% (range 16-35%) before PVE to 27.8% (range 23-42%) after PVE (p = 0.001). All patients were operable for hemihepatectomy of the liver and achieved effective resection. Conclusion: Foam sclerotherapy using polidocanol is clinically safe and effective for preoperative PVE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization: What Do We Know?

Portal vein embolization (PVE) has been developed to increase the size of the future remnant liver (FRL) left in place after major hepatectomy, thus reducing the risk of postoperative liver insufficiency. PVE consist in embolizing preoperatively portal branches of the segments that will be resected. Indication is based on preoperative measurements of the FRL by computed tomography and its ratio with either the theoretical liver volume or by direct measurement of the functional liver volume. After PVE, the volume and function of the FRL increases in 3 to 6 weeks, permitting extensive resections in patients otherwise contraindicated for liver resection. The PVE technique is variable from one center to another; however n-butyl-cyano-acrylate provides an interesting compromise between hypertrophy rate and procedure risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗