Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plugs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Evaluating Transfer and Pumping of Slurries from Pulsed Jet Mixed Vessels

Due to gravity, solids in slurries will settle if density differences between the solids and liquid are positive (i.e., particle has a negative buoyant force) unless rheological properties and flow conditions are adequate to overcome the gravitational effects. The rate of settling depends on the force balance of the particle, which includes the surface forces associated with fluid rheology. Given the same fluid and solid properties, particles that are larger and denser tend to settle faster. When pumping slurry into a vessel at concentrations precluding hindered settling with insufficient mixing, particle and density distributions can result in preferential settling, creating stratification in the solids concentration within the vessel. For vessels with transfer line inlets located in the lower portion of the tank, the stratified solids concentration may be detrimental to the transfer system performance. Elevated concentrations of solids in the slurry entrained at the inlet to the transfer line can result in the effective viscosity or slurry bulk density exceeding the design limits of the pump. These conditions could result in plugging of the transfer line or onset of cavitation of the pumps because of excessive pressure drop. These conditions can be exacerbated with periodic inlet conditions existing at the transfer line inlet. Periodic conditions can result when vessel mixing is intermittent such as with pulsed jet mixers (PJM). The transfer line inlet conditions are impacted by the periodic nature of the PJM operations with respect to suspension of solids and their transport to the inlet of the transfer line. A scaling approach is presented, and corresponding test requirements are developed for assessing the prevention of plugging the pipeline. Line plugging mechanisms are addressed that do not include plugging due to steady-state high-density slurry entering the transfer line and reducing the net positive suction head available (NPSHA) at the pump inlet to below that required for pump operation. Items considered include the transition to reduced relative flow velocities, such that the critical pipe velocity for solids deposition, Ucd, is not maintained, and segregation of heavy solids during the transport. The recommended requirements to prevent plugging include: • Limits for viscosity and density for entrained slurry to prevent the pressure drop in the pipeline from exceeding pump capacity. • Limits for viscosity and density for entrained slurry to prevent the net positive suction head available (NPSHA) from falling below the net positive suction head required (NPSHR) for operating the pump. • Transfer line velocity and flow rate requirements to maintain solids in suspension, while avoiding line plugging that results from deposition of solids within the transfer line. This paper describes the development of the scaling and testing requirements to verify that proposed approaches for transfer and pump out are appropriately developed

periodic flow, mixing, pipeline plugging, scaling,↗

Pilot plant reliability metrics for grinding and fast pyrolysis of woody residues

Here we report on the effects of loblolly pine residue variability on material throughput, pilot plant uptime, operator intervention, product yield, and product quality for grinding, fast pyrolysis, and hydrotreating operations. Preprocessing throughput using a hammer mill varied between 31-48% of nameplate capacity (5 tons/hr). Grinder overloads in the size reduction step were more prevalent for lower ash and higher moisture materials. Fast pyrolysis throughput varied between 57-72% of nameplate capacity (20 kg/hr) and bio-oil yields varied between 46-53% (feedstock carbon to oil, dry basis). During fast pyrolysis operations, downtime was caused by bridging in the feed and char removal systems and plugging in the condensation system. Cohesion of feedstock and char leading to system plugging was less frequent for higher ash feedstocks, and differences in condenser plugging behavior between high and low ash feedstocks were observed. The catalyst stability of the bio-oil stabilization step was strongly dependent on the sulfur content in the bio-oil, which was higher for the high-ash residue oils. Lower moisture content in the starting biomass was consistent with lower sulfur content in bio-oil. Yields and properties of hydrotreated fuel products showed minimal deference among the bio-oils.

Klinger, Jordan↗

Environmental risks and opportunities of orphaned oil and gas wells in the United States

Abstract Hundreds of thousands of documented and undocumented orphaned oil and gas wells exist in the United States (U.S.). These wells have the potential to contaminate water supplies, degrade ecosystems, and emit methane and other air pollutants. Thus, orphaned wells present risks to climate stability and to environmental and human health, which can be reduced by plugging. To quantify environmental risks and opportunities of well plugging at the national level, we analyze data on 81 857 documented orphaned wells across the U.S. We find that > 4.6 million people live within 1 km of a documented orphaned well. 35% of the documented orphaned wells are located within 1 km of a domestic groundwater well, yet only 8% of the wells have groundwater quality data within a 1 km radius. Methane emissions from the documented orphaned wells represent approximately 3%–6% of total U.S. methane emissions from abandoned oil and gas wells, but this estimate is based on measurements at < 0.03% of U.S. abandoned wells. 91% of the documented orphaned wells overlie formations favorable for geologic storage of carbon dioxide and hydrogen, meaning that orphaned well plugging can reduce leakage risks from future storage projects. Finally, we estimate plugging costs for documented orphaned wells to exceed the $4.7 billion federal funding by 30%–80%, emphasizing the importance of prioritizing federal spending on wells with large remediation benefits. Overall, environmental monitoring data are not extensive enough to quantify risks, especially those related to air and water quality and human health. Plugging orphaned wells can provide opportunities for geologic storage of carbon dioxide and hydrogen and geothermal energy development, thereby facilitating efforts to transition to net-zero energy systems. Our analysis on environmental risks and opportunities of orphaned wells provides a framework that can be used to manage the millions of documented and undocumented orphaned wells in the U.S. and abroad.

54 ENVIRONMENTAL SCIENCES↗

Progress Report on Model Development for the Transport of Aerosol Through Microchannels

Accuracy of consequence assessments could be improved by accounting for the leak path deposition of aerosol in the source term. Recent experimental measurements from Sandia (2018) provided evidence of partial microchannel plugging due to particulate deposition. This filtration effect is relevant to the source term assessments and it is not unreasonable to anticipate that aerosol deposition in more realistic geometries could even lead to complete plugging of the leak path. This report summarizes current progress (as of end of Q3 FY 2020) on the development of a phenomenological model of aerosol transport, deposition, and plugging through microchannels. The purpose is to introduce a generic, reliable numerical model for the prediction of aerosol transport, deposition, and plugging in leak paths while accounting for potential plugging formation. This report includes (1) an overview of recent additions and improvements on the recently developed numerical model to analyze the various deposition processes in leak paths, to provide quantitative estimates of penetration factors, and to gain an understanding of the variables that affect them and (2) a summary of recent benchmarking results of the model’s validity with recent experimental measurements from Sandia.

54 ENVIRONMENTAL SCIENCES↗

Total Cost of Ownership Reduction Using Passive Pre-Chamber Ignition in Natural Gas Engines

Spark plug durability is a factor affecting the total cost of ownership (TCO) of spark-ignited natural gas engines, with some heavy-duty platforms requiring plug replacement after only 750 hours of operation. The high ignition energy demand under lean or diluted conditions accelerates electrode wear, shortening plug life and increasing maintenance frequency. This work evaluates passive pre-chamber (PC) ignition operating at lowered spark energies as a strategy to reduce spark energy requirements and extend plug durability, thereby lowering TCO. Experiments were conducted on a medium-duty Cummins 6.7L ISB engine at 1600 RPM and 50% load under varying exhaust gas recirculation (EGR) dilution levels (0–40%). Two passive pre-chambers with 1.1 mm and 1.6 mm nozzle diameters were compared with conventional spark ignition (SI). SI was operated with a fixed coil dwell of 4 ms (~90 mJ), while the PC configuration was tested across 2–4 ms dwell times (~30–90 mJ). Cylinder pressure analysis revealed that PC ignition sustained stable combustion at significantly lower spark energies than SI, with improved combustion stability at ~30 mJ compared with SI at ~90 mJ. The PC system also extended the dilution tolerance beyond that achievable with SI, while delivering up to ~2% higher indicated thermal efficiency and reducing the COV by nearly 90% at 30% EGR. A TCO analysis was conducted to assess the economic benefit of adopting a passive PC system operating at reduced spark energies compared to SI. It was found that adopting a passive PC system could reduce TCO by approximately $11,000 per engine over a five-year operational period, primarily due to fuel savings, extended spark plug life, and reduced maintenance frequency. These projections were weighed against the additional hardware cost of the pre-chamber, yielding a rapid estimated return on investment of ~300 operating hours. Therefore, this work motivates continued research and development of passive PC technology and its commercial adoption in natural gas engines used in transportation applications.

Dhotre, Akash [University of Minnesota]↗

Origins of wear-induced tungsten corrosion defects in semiconductor manufacturing during tungsten chemical mechanical polishing

During chemical mechanical polishing (CMP) process optimization, a unique corrosion defect was identified in the tungsten (W) contact plugs, which were investigated to develop practical solutions to improve CMP mass productivity. The corrosion defect occurred in the absence of external incident energy and was observed to occur only at the W plugs connected to the P + /n-well close to the wafer edge. To examine the root cause of the corrosion, a series of experiments was carried out at each W CMP step, using in-line defect inspection. Additional experiments were conducted using on-line inductively coupled plasma mass spectrometry (ICP-MS) to understand pH- and potential-dependent electrochemical dissolution behaviors of W. Experimentally, W corrosion was confirmed to be exacerbated if the surface oxide of the W plugs is removed by the deionized water (DIW) rinsing step under wafer pressurization, then exposed to DIW and alkaline cleaning solution. Although the DIW rinsing step is commonly performed to clean polishing pads right after the main polishing, a small amount of applied pressure (0.5 psi) without slurry supply can lead to corrosion defects. Finally, this wear-induced corrosion of the W plugs can be prevented by removing the applied pressure during the post DIW rinsing step of W CMP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PHEV Distribution Grid Integration and Smart Systems Testing: Cooperative Research and Development Final Report

To continue NREL's mission, which includes preparing technologies and markets with "speed and scale," NREL researchers will collaborate with Toyota on plug-in electric vehicle technology. Toyota will provide a collection of plug-in hybrid electric vehicles ("PHEVs" [and ultimately including PEVs], collectively, the "Vehicles") to conduct infrastructure interaction testing at NREL facilities. NREL will use available resources in the Vehicle Testing and Integration Facility (VTIF), its staff parking garage with numerous commercial Electric Vehicle Supply Equipment ("EVSEs"), and its Energy Systems Integration Facility (ESIF) to safely execute research experiments that highlight potential distribution system power quality challenges related to plug-in electric vehicles. The expected outcome of this project is a better understanding of the correlation of individual vehicle power quality attributes to a system of vehicles on a distribution network. The data collected and the simulations conducted will be used to guide future experiments and project development that aid in the deployment of plug-in electric vehicles ("PEV").

24 POWER TRANSMISSION AND DISTRIBUTION↗

Particle-based modelling of axisymmetric tandem mirror devices

In this work, we describe the use of a 1D-2V quasi-neutral hybrid electrostatic PIC with Monte-Carlo Coulomb collisions and non-uniform magnetic field to model the parallel transport and confinement in an axisymmetric tandem mirror device. End-plugs, based on simple-mirrors, are positioned at each end of the device and fueled with neutral beams (25 and 100 keV) to produce a sloshing ion population and increase the density of the end-plugs relative to the central cell. Results show the formation of a potential difference barrier between the central cell and the end-plugs. This potential confines a large fraction of the low energy thermal ions in the central cell which would otherwise be lost in a simple mirror, demonstrating the advantage of the beam-driven tandem mirror configuration relative to simple mirrors. In addition, we explore the effect of end-plug electron temperature on the confinement time of the device and compare it with theoretical estimates. Finally, we discuss the limitations of the code in its present form and describe the next logical steps to improve its predictive capability such as a fully nonlinear Fokker–Planck collision operator, multiply nested flux surface solutions and modeling the exhaust region up to the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geometric Optimization of an Electrochemical Purification Cell to Prevent Corrosion in CSP Plants During Operation

When exposed to moisture or oxygen, molten chloride salts produce corrosive impurities which degrade containment alloys. This can significantly decrease the lifetime and increase costs of molten-salt-based systems. To overcome this barrier, we designed and modeled an electrochemical purification cell to remove the corrosive impurity MgOH+. Various reactor architectures, including continuous stirred tank reactors (CSTRs) and plug flow reactors (PFRs) were investigated. Steady-state thermoelectric properties were evaluated using analytical methods, allowing assessment of the effects of structure and design parameters such as flow rate, cell length, and cross-sectional area of molten salt. The results suggest that our design could most effectively increase reliability and decrease costs of molten-chloride-salt-based systems by protecting them during continuous operation using an annular plug flow reactor.

analytical modeling↗

Wettability Alteration with Weak Acid-Assisted Surfactant Flood

Oil-wetness and heterogeneity are two key reasons for low oil recovery by waterflooding in carbonate reservoirs. Surfactants have been effective in altering the oil-wet matrix to a more water-wet condition and initiating spontaneous imbibition. Because it takes time for the surfactant to alter wettability, oil recovery from the tight matrix is slow and sometimes not economically feasible. Acids have the potential of dissolving minerals, which may alter wettability. In this study, the enhanced oil recovery (EOR) performance of an acid-assisted surfactant solution, a novel technique, was evaluated for low-temperature applications. A set of acids and their acetates were tested. Bulk rock-acid reaction, wettability alteration (WA) tests, and spontaneous imbibition measurements were conducted at reservoir temperature (35°C) to identify effective candidates. Coreflood tests were then performed to evaluate the selected acid-surfactant formulations. Before and after a coreflood test, the core was scanned using micro-computed tomography (CT) to investigate pore structure alteration. Bulk reaction measurements showed that weak acids, especially acetic acid (AA), have the desired low reaction rates at 35°C. WA tests showed that AA can remove the crude oil off the rock surface and alter wettability through mineral dissolution. The surfactant can reduce contact angles from 160° to 58°; adding acid into the surfactant can further reduce it to 52°. Spontaneous imbibition experiments showed the synergy between the acid and the surfactant; the AA-surfactant solution had the highest oil recovery (62.6%) among acid-surfactant formulations. The acid improves the WA efficiency by the surfactant through surface mineral dissolution and lower ζ-potential. The imbibition transports the acid-surfactant solutions into the matrix, which minimizes face dissolution. Coreflood tests show that the AA-surfactant flood can increase the oil recovery rate and recover about 8% more oil compared to the surfactant flood. Micro-CT showed that a few mineral particles were transported along the core and partially plugged pore throats, which reduced permeability and diverted flow leading to improved oil recovery. Here, the transport of the acid in reservoirs and the potential plugging issues have to be carefully evaluated in future studies.

58 GEOSCIENCES↗

Progress Report on Model Development for the Transport of Aerosol through Microchannels

This report summarizes the current progress in the development of a phenomenological model of aerosol transport, deposition, and plugging through microchannels. The purpose is to introduce a generic, reliable numerical model for the prediction of aerosol transport, deposition, and plugging in leak paths while accounting for potential plugging formation, to a user community involving researchers, regulators, and industry. In that regard, a Graphical User Interface (GUI) was generated by integrating the individual MATLAB scripts that make up the model and adding additional features to aid the general understanding of the problem to a user. This report focuses on the model development and features included. Further, predictions from the GUI are compared with experimental data for validation. The strength of the GUI is the ability of a user to plug in basic parameters such as the initial pressure conditions and canister model specifications in order to obtain a first principal approximation of vital information such as the blowdown pressure differential, aerosol penetration, and deposition as a function of time. The user can obtain this without the know-how of the underlying MATLAB scripts and thus enables the model to be readily applied by regulators, industry, and shareholders to reduce the uncertainty in the off-site radiological consequences. The report also lists future tasks under this work scope. This includes ongoing efforts to include additional crack geometries (divergent and divergent-convergent slots) to the model; GUI development and improvement based on feedback from users, and integration of aerosol source term data from Sibling Pin tests into the model as we approach realistic canister stress corrosion cracking–induced aerosol release scenarios.

54 ENVIRONMENTAL SCIENCES↗

Preliminary Development of Heat Transfer Model-Based Control Algorithms of Liquid Sodium Purification System: Advanced Sensors and Instrumentation Advanced Controls

Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimizing the Heisenberg Vortex Tube for Hydrogen Cooling (Final Technical Report)

Hydrogen utilization at Plug Power sites ranges between 70-93% with the remainder vented and lost to the atmosphere. The goal of this project was to improve hydrogen utilization at Plug Power fulfillment centers via the patented Heisenberg vortex tube (HVT). The HVT combines conventional counterflow vortex tubes with para-orthohydrogen conversion catalyst to allow the cooling of hydrogen flows with no moving parts or external energy inputs. In year 1 of this project the HVT was evaluated to improve hydrogen utilization via the following concepts: 1) increasing liquid hydrogen pump volumetric efficiency by 20% through vapor separation and subcooling of the liquid, 2) reducing liquid hydrogen storage tank boil-off losses by 20% through thermal vapor shielding (TVS), and 3) increase isentropic efficiency of supercritical hydrogen expansion at 40-50 K, from 31% to over 40%. The TVS concept was selected as the most favorable application for further development. While the conceptual analysis was underway, the cryocatalysis hydrogen experiment facility (CHEF) was retrofitted with a new cryocooler, higher pressure condenser tanks, and in-situ fiber-optic Raman probes for ortho-parahydrogen composition analysis at the inlets and outlets of the HVT. To our knowledge this is the first in-situ implementation of cryogenic Raman probes for ortho-parahydrogen analysis. Subsequent testing of catalyzed and non-catalyzed HVT identified a low flow rate, high-conversion efficacy regime well suited for TVS development. Computational fluid dynamics (CFD), Reduced order modeling (ROM), and quantum Monte Carlo atomistic simulations were applied to optimize the design of the HVT implemented for TVS. The simulations and analysis identified a ruthenium-based catalyst as the most optimal for high conversion with little pressure losses and was matched to experimental measurements. These results indicated the design could achieve the 20% boil-off reduction target. An HVT field-trial was designed and constructed by Plug Power and implemented at a customer site. However, budget limitations reduced the amount of catalyst that could be applied to the HVT. With the reduced amount of catalyst, CFD analysis estimated about 3% reduction in boil-off. A similar amount of boil-off reduction was observed during preliminary measurements during tank commissioning. However, the results have a large margin for error and were operated at relatively low tank temperatures when the HVT has the lowest potential for improvement. This project demonstrated the use of para-orthohydrogen catalysis for reducing liquid hydrogen tank boil-off losses. The field trial system is anticipated to provide long-term experimental measurements on tank operational performance that will allow Plug Power to instrument additional tanks in the future. Recommendations for future work include the development of higher activity, lower cost para-orthohydrogen conversion catalyst for use in the HVT. Tank process optimizations could maximize the efficacy of the HVT and further improve hydrogen utilization.

08 HYDROGEN↗

WHA Sphere Impacting RHA Plate: Modeling Brittle Behavior in Metal Alloys

Brittle behavior of metal alloys is often critical to modeling ballistic impact and penetration. The ALEGRA multiphysics finite element software incorporates calibrated models for the equation of state, elasticity, yield stress, plasticity and fracture, but simulations do not always capture expected metal fracture. Here we report concerted efforts to do so for one important case where experiments clearly show shear fractures: a tungsten sphere impacting a steel plate at various angles. Our best simulations show fractures that are qualitatively similar to experiments, but there are significant differences in quantitative metrics. Specifically, velocities of tracers used to quantify simulated plug parameters consistently fall short of measured plug velocities. Also, simulated plugs break apart more than expected from experimental evidence. We attribute these shortfalls to the lack of an explicit shear fracture mechanism in the material models, leading to over-estimated resistance to plug formation and movement.

36 MATERIALS SCIENCE↗

ELECTRIFICATION OF A HEAVY-DUTY OFF-ROAD MATERIAL HANDLER: ENERGY SAVINGS AND EMISSION REDUCTIONS

Federal regulations are driving the adoption of electrification technologies to reduce carbon dioxide equivalent (CO2e) emissions, a metric that quantifies the global warming potential of various greenhouse gases in terms of carbon dioxide (CO2). Although no specific CO2 regulations exist for heavy-duty off-road machines, future reductions are likely, given stricter emissions standards for on-road vehicles. The heavy-duty off-road sector offers significant fuel-saving potential, as its focus has traditionally been on reliability and performance rather than fuel efficiency. This dissertation examines fuel and CO2e savings opportunities on a heavy-duty off-road material handler, the Pettibone Cary-Lift 204i, from stock configuration to simple modifications to a complete teardown and reconfiguration of the machine with a plug-in series hybrid architecture using electrified hydraulics. The study begins by modeling the baseline machine’s fuel and energy consumption, calibrating with experimental data from custom operating cycles. An energy analysis identifies key areas for fuel savings. Two simple powertrain modifications result in a combined 16.2% fuel savings. Next, a Pugh-style analysis narrows a list of electrified architectures, leading to high-fidelity models that evaluate total lifetime CO2e and costs. Higher electrification levels reduce CO2e emissions but increase costs, and electricity grid emissions significantly impact CO2e for plug-in architectures. A plug-in series hybrid is chosen for the project. In its base control form, 49% fuel and 29% CO2e savings are expected from the plug-in series hybrid compared to the baseline machine. Further savings are pursued through regenerative braking (6.3%) and load-following hydraulic control (17.8%), totaling 24.1% fuel savings, and leading to a total of 61% fuel and 41% CO2e savings compared to the baseline. Battery chemistries and charging strategies are also analyzed for cost and CO2e impacts, finding LFP batteries as superior due to longevity, and overnight level 2 charging usually at a lower cost but resulting in higher emissions than opportunity DC fast-charging (DCFC). DCFC emissions are highly dependent on grid emissions, and DCFC cost is highly dependent on grid demand charges. Finally, artificial intelligence is applied to operating cycle recognition. Neural network accuracy ranges from 81% to 99%, with applications to worksite efficiency and safety improvements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Surface Chemistry and Particle Morphology Changes in Pine Biomass under Indirect Thermal Gradients: Implications for Feed Screw Design

The conversion of biomass feedstocks into fuels and chemicals using fast pyrolysis is a promising approach to renewable energy. Feed screws that convey biomass to pyrolysis reactors, however, often encounter plugging. Indirect heating of the feed screw occurs due to contact with the pyrolysis chamber, resulting in a heating gradient ranging from ambient temperature (22 °C) to reactor temperature (500 °C). Given that major cell wall macromolecules, such as lignin, cellulose, and hemicellulose, begin to produce bio-oils and volatile resin acid compounds within this temperature gradient, we hypothesized that indirect heating during feed screw conveyance is sufficient to cause premature degradation of biomass. We characterized this degradation by observing increases in surface roughness, changes in overall particle morphology, and the production and deposition of bio-oils on biomass particle surfaces. Correlative analysis between optical in situ hot-stage microscopy, confocal Raman spectroscopy, and SEM analysis revealed that heating at temperatures as low as 375 °C caused significant increases in surface roughness, with large fissures forming between and within cell walls. Additionally, droplets of bio-oil were observed on particles, especially in the bark and cambium samples. This work suggests that these phenomena contribute to particle agglomeration, leading to feed screw plugging, and that engineering a solution to cool the feed screw could prevent particle agglomeration and reduce plugging incidents, thereby increasing biomass processing efficiency.

09 BIOMASS FUELS↗

Confirmation and Quantification of Gas Flow into Capsules

Inertial confinement fusion experiments require a fuel filled target. At the National Ignition Facility (NIF), these targets are filled through a capsule fill tube assembly (CFTA). While fabricating these assemblies, it is possible to plug the fill tube with glue, which would render the CFTA and eventual target unusable. Historically, this plugging was first detectable in a finished target after considerable resources had been expended. Herein, this paper presents a method for not only detecting a plug in the fill tube before the CFTA is assembled into a target, but also characterizing gas flow through the fill tube, which can help NIF operations prepare to expend each target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ibis Networks/WattIQ (IN2 Final Report)

Ibis Networks is a full-stack cleantech company that provides plug-level energy monitoring and control to solve energy and asset management problems for the enterprise. During DATES – DATES, an NREL research team worked with the Ibis team to validate their product, the InteliSocket. The Ibis InteliSocket is a pass-through plug-load energy monitor and controller that is designed to reduce energy wasted by common 120 V plug-in devices in commercial office buildings, such as computer peripherals, conference room AV equipment, and break-room appliances. The system can shut off supply power to these end uses via remote control, manual switches, pre-set schedules, or automated control algorithms. The scope of this IN2 project was the development and refinement of “smart” learning behavior algorithms (LBAs), which could help installation processes and dramatically expand the sockets’ capabilities and energy-saving potential by suggesting suitable control schedules that are based on monitored use patterns. While Ibis has the analytical and software expertise for algorithm development, the lack of test data, both in a controlled laboratory setting and in real-life deployment scenarios, represented a key barrier toward commercialization of the product. Assistance through the IN2 program provided an opportunity to conduct the needed “trial and error” algorithm development. The project included baseline field-data collection, laboratory testing, and field validation components, all of which were conducted at the NREL campus between April 2017 and July 2019.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗