Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plenum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Adaptive-wall wind-tunnel research at Ames Research Center

Adaptive-wall wind-tunnel research is summarized. This research includes small-scale two- and three-dimensional wind-tunnel experiments and numerical experiments with a three-dimensional adaptive-wall simulator. Airflow through the test-section walls is controlled by adjusting the pressures in segmented plenums. Interference free conditions are successfully attained in subsonic and transonic flows. An adaptive wall test section is constructed for the transonic wind tunnel. Wall interference was reduced in the three dimensional experiment at several angles of attack at Mach 0.60. A wing on wall configuration was modeled in the numerical experiments. These flow simulations showed that free air conditions can be approximated by adjusting boundary conditions at only the floor and ceiling of the test section. No sidewall control was necessary.

Schairer, E. T.↗

Some solutions to the problems and pitfalls of laser velocimetry in a large transonic wind tunnel

Attention is given to engineering design and development features of a two-component, coaxial backscatter laser velocimetry system which attempts to realize the long-recognized desirability of this technique's use for nonintrusive flow measurement. The design of the optics for the present 16-foot transonic wind tunnel device, and problems associated with the installation of the system in the hostile, test section plenum chamber environment are discussed.

Reubush, D. E.↗

Video model deformation system for the National Transonic Facility

A photogrammetric closed circuit television system to measure model deformation at the National Transonic Facility is described. The photogrammetric approach was chosen because of its inherent rapid data recording of the entire object field. Video cameras are used to acquire data instead of film cameras due to the inaccessibility of cameras which must be housed within the cryogenic, high pressure plenum of this facility. A rudimentary theory section is followed by a description of the video-based system and control measures required to protect cameras from the hostile environment. Preliminary results obtained with the same camera placement as planned for NTF are presented and plans for facility testing with a specially designed test wing are discussed.

Burner, A. W.↗

Sonic levitation apparatus

A sonic levitation apparatus is disclosed which includes a sonic transducer which generates acoustical energy responsive to the level of an electrical amplifier. A duct communicates with an acoustical chamber to deliver an oscillatory motion of air to a plenum section which contains a collimated hole structure having a plurality of parallel orifices. The collimated hole structure converts the motion of the air to a pulsed. Unidirectional stream providing enough force to levitate a material specimen. Particular application to the production of microballoons in low gravity environment is discussed.

Dunn, S. A.↗

Quasi-Porous Plug With Vortex Chamber

Pressure-letdown valve combines quasi-porous-plug and vortex-chamber in one controllable unit. Valve useful in fossil-energy plants for reducing pressures in such erosive two-phase process streams as steam/water, coal slurries, or combustion gases with entrained particles. Quasi-Porous Plug consists of plenums separated by perforated plates. Number or size of perforations increases with each succeeding stage to compensate for expansion. In Vortex Chamber, control flow varies to control swirl and therefore difference between inlet and outlet pressures.

Walsh, J. V.↗

Rotary Speed Sensor for Antilocking Brakes

Sensor based on fluidic principles produces negative pressure approximately proportional to rotational speed. Sensor developed as part of antilocking brake system for motorcycles. Uses inlet pressure rather than outlet pressure as braking-control signal, eliminating pressure pulsations caused by pump vanes and ensuring low-noise signal. Sensor is centrifugal air pump turned by one of motorcycle wheels. Air enters pump through orifice plates, and suction taken off through port in pump inlet plenum.

Berdahl, C. M.↗

National transonic facility shakedown test results and calibration plans

The results of the shakedown tests and the calibration plan of the National Transonic Facility (NTF) are presented. The facility is designed to operate in both air and nitrogen modes, cover Mach numbers from 0.2 to 1.2, pressures up to 8.8 atm and temperatures between 77 and 339 K. The facility data system is built around four 16-bit minicomputers with a total memory of three megabytes. A portable cryogenic chamber is available. The tunnel systems were operated in a series of tests in Mach number range of 0.2 to 1.17, pressures up to 8.5 atm, and temperatures down to 100 K. The calibration plan includes steady-state and dynamic calibration, as well as wall interference studies. The facility underwent the checkout of the model attitude, plenum isolation, and model access systems, followed by aerodynamic calibration in 1984. Schematic drawings and diagrams are included.

Bruce, W. E., Jr.↗

On boundary layer transition in high-subsonic and transonic flow under the influence of acoustic disturbances and free-stream turbulence

The existing data base which quantifies the roles played by the Mach number, turbulence level, and acoustic noise in the flow quality of wind tunnels is reviewed. Attention is given to the effects on end (ET) and beginning (BT) transitions in flows over a 10 deg cone in transonic channels. The Re of both ET and BT flows were significantly affected by the Mach number, acoustic noise level and the noise frequency content. A unit increment in the Mach number increased the Re beyond 3,000,000, while noise below the 1 percent level in the rms pressure coefficient did not alter the transition phenomenon. More data are required on the effects of turbulence, which was a significant factor, and in the settling chamber, test section, plenum and diffuser to trace the locations and magnitudes of the acoustic sources.

Murthy, S. V.↗

Velocity selective flow visualization in a free supersonic nitrogen jet with the resonant Doppler velocimeter

The use of the resonant Doppler velocimeter for flow visualization in a free supersonic nitrogen jet is demonstrated experimentally. In the experiment reported here, room-temperature nitrogen at 12.7 psi expands through a Mach 3.4 converging diverging nozzle into a plenum chamber; small amount of sodium is injected through a heated needle centered 0.5-in. upstream of the nozzle throat. The beam of a single frequency dye laser is expanded into a sheet of light with a cylindrical beam expander and directed counter to the jet to spatially resolve any slice across the core of the flow. By tuning the laser to different frequencies, particular velocity and density fields can be highlighted.

Zimmermann, M.↗

Particle generation experience in Langley's 16-foot transonic tunnel

The Langley 16-Foot Transonic Tunnel is a single-return, continuous-flow, atmospheric tunnel which uses air exchange for cooling. The tunnel speed is continuously variable from Mach 0 to 1.30. The test section is a regular octagon in cross-section with slots at the corners of the octagon. The laser velocimeter optics, laser, photomultipliers, etc. are mounted in the test section plenum chamber which surrounds the test section. The test volume is approximately a 1-meter cube about the tunnel center line centered on tunnel station 40.84 meters. The seeding system particle generators are mounted on the upstream side of the fourth set of turning vanes approximately 49 meters upstream of the test volume. At this point the tunnel has a diameter of 17.68 meters which meant that installation of the generators was a difficult procedure. It might be noted that particle generation had to be continuous as when the generators were turned off the data rate rapidly deteriorated to zero.

Reubush, D. E.↗

Turbulent dispersion of the icing cloud from spray nozzles used in icing tunnels

To correctly simulate flight in natural icing conditions, the turbulence in an icing simulator must be as low as possible. But some turbulence is required to mix the droplets from the spray nozzles and achieve an icing cloud of uniform liquid water content. The goal for any spray system is to obtain the widest possible spray cloud with the lowest possible turbulence in the test section of a icing tunnel. This investigation reports the measurement of turbulence and the three-dimensional spread of the cloud from a single spray nozzle. The task was to determine how the air turbulence and cloud width are affected by spray bars of quite different drag coefficients, by changes in the turbulence upstream of the spray, the droplet size, and the atomizing air. An ice accretion grid, located 6.3 m downstream of the single spray nozzle, was used to measure cloud spread. Both the spray bar and the grid were located in the constant velocity test section. Three spray bar shapes were tested: the short blunt spray bar used in the NASA Lewis Icing Research Tunnel, a thin 14.6 cm chord airfoil, and a 53 cm chord NACA 0012 airfoil. At the low airspeed (56 km/hr) the ice accretion pattern was axisymmetric and was not affected by the shape of the spray bar. At the high airspeed (169 km/hr) the spread was 30 percent smaller than at the low airspeed. For the widest cloud the spray bars should be located as far upstream in the low velocity plenum of the icing tunnel. Good comparison is obtained between the cloud spread data and predicitons from a two-dimensional cloud mixing computer code using the two equation turbulence (k epsilon g) model.

Marek, C. J.↗

Model deformation measurements at a cryogenic wind tunnel using photogrammetry

A photogrammetric closed circuit television system to measure model deformation at the National Transonic Facility (NTF) is described. The photogrammetric approach was chosen because of its inherent rapid data recording of the entire object field. Video cameras are used to acquire data instead of film cameras due to the inaccessibility of cameras which must be housed within the cryogenic, high pressure plenum of this facility. Data reduction procedures and the results of tunnel tests at the NTF are presented.

Burner, A. W.↗

Noise generated by flow through large butterfly valves

A large butterfly valve (1.37 m diam) was acoustically tested to measure the noise generated and propagating in both the upstream and downstream directions. The experimental investigation used wall mounted pressure transducers to measure the fluctuating component of the pipe static pressure upstream and downstream of the valve. Microphones upstream of the pipe inlet and located in a plenum were used to measure the noise radiated from the valve in the upstream direction. Comparison of the wall pressure downstream of the valve to a prediction were made. Reasonable agreement was obtained with the valve operating at a choked condition. The noise upstream of the valve is 30 dB less than that measured downstream.

Huff, Ronald G.↗

Computation of nozzle flow fields using the PARC2D Navier-Stokes code

Supersonic nozzles which operate at low Reynolds numbers and have large expansion ratios have very thick boundary layers at their exit. This leads to a very strong viscous/inviscid interaction upon the flow within the nozzle and the traditional nozzle design techniques which correct the inviscid core with a boundary layer displacement do not accurately predict the nozzle exit conditions. A full Navier-Stokes code (PARC2D) was used to compute the nozzle flow field. Grids were generated using the interactive grid generator code TBGG. All computations were made on the NASA MSFC CRAY X-MP computer. Comparison was made between the computations and in-house wall pressure measurements for CO2 flow through a conical nozzle having an area ratio of 40. Satisfactory agreement existed between the computations and measurements for a stagnation pressure of 29.4 psia and stagnation temperature of 1060 R. However, agreement did not exist at a stagnation pressure of 7.4 psia. Several reasons for the lack of agreement are possible. The computational code assumed a constant gas gamma whereas gamma for CO2 varied from 1.22 in the plenum chamber to 1.38 at the nozzle exit. Finally, it is possible that condensation occurred during the expansion at the lower stagnation pressure.

Collins, Frank G.↗

Experimental evaluation of wall Mach number distributions of the octagonal test section proposed for NASA Lewis Research Center's altitude wind tunnel

Wall Mach number distributions were determined over a range of test-section free-stream Mach numbers from 0.2 to 0.92. The test section was slotted and had a nominal porosity of 11 percent. Reentry flaps located at the test-section exit were varied from 0 (fully closed) to 9 (fully open) degrees. Flow was bled through the test-section slots by means of a plenum evacuation system (PES) and varied from 0 to 3 percent of tunnel flow. Variations in reentry flap angle or PES flow rate had little or no effect on the Mach number distributions in the first 70 percent of the test section. However, in the aft region of the test section, flap angle and PES flow rate had a major impact on the Mach number distributions. Optimum PES flow rates were nominally 2 to 2.5 percent wtih the flaps fully closed and less than 1 percent when the flaps were fully open. The standard deviation of the test-section wall Mach numbers at the optimum PES flow rates was 0.003 or less.

Harrington, Douglas E.↗

The evolution of adaptive-wall wind tunnels

Since its inception, adaptive wall wind tunnel design has developed three major configurational possibilities: streamlined walls, variable porosity walls, and segmented plenum arrangements. All of these methods have demonstrated their feasibility for transonic flow research; development programs are noted to be underway for three-dimensional adaptive wall tunnels. With the availability of advanced computational procedures, routine angle-of-incidence or Mach sweeps may be treated numerically, while adaptive wall wind tunnels are employed for complementary point-design and for testing at flow conditions that are beyond the capabilities of current numerical modeling.

Davis, S. S.↗

Construction of a 2- by 2-foot transonic adaptive-wall test section at the NASA Ames Research Center

The development of a new production-size, two-dimensional, adaptive-wall test section with ventilated walls at the NASA Ames Research Center is described. The new facility incorporates rapid closed-loop operation, computer/sensor integration, and on-line interference assessment and wall corrections. Air flow through the test section is controlled by a series of plenum compartments and three-way slide vales. A fast-scan laser velocimeter was built to measure velocity boundary conditions for the interference assessment scheme. A 15.2-cm- (6.0-in.-) chord NACA 0012 airfoil model will be used in the first experiments during calibration of the facility.

Morgan, Daniel G.↗

Navier-Stokes simulation of real gas flows in nozzles

Air flow in a hypersonic nozzle causes real gas effects due to reaction among the species constituting air. Such reactions may be in chemical equilibrium or in chemical nonequilibrium. Here using the CSCM upwind scheme for the compressible Navier-Stokes equations, the real gas flowfield in an arcjet nozzle is computed for both the equilibrium case and the nonequilibrium case. A hypersonic nozzle flow arising from a pebble bed heated plenum is also computed for the equilibrium situation. Between the equilibrium cases, the chemistry is treated by two different schemes and comments are made as to computational complexity. For the nonequilibrium case, a full set of seventeen reactions and full implicit coupling of five species with gasdynamics is employed to compute the flowfield. For all cases considered here the gas is assumed to be a calorically imperfect mixture of ideal gases in thermal equilibrium.

Nagaraj, N.↗