Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pinhole optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

155 records · Page 9

Influence of Evaporation Rate and Chamber Pressure on the FUV Reflectance and Physical Characteristics of Aluminum Films

Space telescopes for studying astrophysical phenomena from the far ultraviolet (FUV) to the near infrared (NIR) require durable mirror coatings with high and uniform reflectance over a very broad spectral region. While coatings for the optical and NIR region are well developed with proven performance, the FUV band presents significant challenges, particularly below 115 nm. Recent developments in physical vapor deposition (PVD) coating processes of aluminum mirrors that are protected with a metal-fluoride overcoat to prevent oxidation (such as LiF, MgF2, or AlF3) have improved reflectance in the FUV. While the emphasis in these studies has been placed on improving the deposition conditions of the metal-fluoride overcoats, less attention has been devoted to how deposition parameters (such as vacuum conditions or deposition rates) may affect the quality of the aluminum mirrors. This paper presents characterization of Al+MgF2 coupons made by flash evaporation of aluminum followed by resistive evaporation of MgF2. Samples were manufactured under a variety of processing conditions and the relationship between processing variables and mirror FUV reflectivity is analyzed. Performance characterization was based on the measured near-normal reflectance in the FUV (90-180 nm), and normal-incidence transmittance in the visible was done to analyze the possible presence of pinholes in the mirror. We demonstrated pinhole-free Al/MgF2 mirrors deposited at room temperature with a reflectivity of 0.91 at 122 nm wavelength. This reflectivity enhancement was achieved solely through parameter optimization.

FUV reflectance, aluminum, PVD, deposition rate, A↗

Generation and characterization of plasma channels in gas puff targets using soft X-ray radiography technique

We present our recent results of a formation and characterization of plasma channels in elongated krypton and xenon gas puff targets. The study of their formation and temporal expansion was carried out using a combination of a soft X-ray radiography (shadowgraphy) and pinhole camera imaging. Two high-energy short laser pulses were used to produce the channels. When a pumping laser pulse was shaped into a line focus, using cylindrical and spherical lenses, the channels were not produced because much smaller energy density was deposited in the gas puff target. However, when a point focus was obtained, using just a spherical lens, the plasma channels appeared. The channels were up to 9 mm in length, had a quite uniform density profile, and expanded in time with velocities of about 2 cm/μs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Higher Accuracy Template for Corner Cube Reflected Image

Video images of laser beams are analyzed to determine the position of the laser beams for alignment purpose in the National Ignition Facility (NIF). Algorithms process beam images to facilitate automated laser alignment. One such beam image, known as the corner cube reflected pinhole image, exhibits wide beam quality variations that are processed by a matched-filter-based algorithm. The challenge is to design a representative template that captures these variations while at the same time assuring accurate position determination. This paper describes the development of a new analytical template to accurately estimate the center of a beam with good image quality. The templates are constructed to exploit several key recurring features observed in the beam images. When the beam image quality is low, the algorithm chooses a template that contains fewer features. The algorithm was implemented using a Xilinx Virtex II Pro FPGA implementation that provides a speedup of about 6.4 times over a baseline 3GHz Pentium 4 processor.

42 ENGINEERING↗

Time Resolved Optical Studies on The Plasmonic Field Enhancement of Bacteriorhodopsin Proton Photo-current: Final Technical Report Covering Aug 31, 2015–Aug 31, 2016

Our research continues to focus on the effects of plasmonic nanoparticles on organic and inorganic light-harvesting materials. Recent work has focused on the synthesis of stabilized gold nanoparticles to enhance the efficiency of dye-sensitized solar cells (DSSCs). Two major concerns in dye sensitized solar cells (DSSCs) are efficient light absorption and charge collection. Charge collection typically suffers because transport of electrons through the mesoporous TiO 2 substrate is slow. Thus, one obvious way to improve charge collection is to reduce the thickness of the TiO 2 . Alternatively, a form of TiO 2 with fewer grain boundaries, such as nanotubes, could be used in place of sintered nanospheres. Unfortunately, both of these solutions end up reducing the amount of surface area available to adsorb dye molecules. This directly reduces the percentage of photons absorbed. This problem could be avoided if dye molecules with larger absorption were designed; although synthetic chemists seem to be pushing the limits of what is achievable. Plasmonic nanoparticles offer an alternative way to boost light absorption. It is well known that plasmonic nanoparticles can enhance the local electric field of resonant frequencies of light. If this were in the same spectral region as the dye’s absorption band it would increase the percentage of absorbed photons. One concern is that if the nanoparticles are too close to the dye molecules they can quench the excited state. To avoid this problem, we prepared gold nanoparticles with a silica shell. This limited the amount of quenching while still permitting some enhancement of absorption. Unfortunately, we ran into some serious issues. The iodide based electrolyte etched the gold nanoparticles, completely dissolving them within a few hours. The silica shell should have provided protection but there were pinholes through which iodide could diffuse. Increasing the thickness of the silica to over 10 nm prevented etching but also limited any photon absorption enhancement.

36 MATERIALS SCIENCE↗

Tomographic imaging of a target directly irradiated in experiments on the Iskra-5 iodine laser facility

We set forth the data of experiments involving direct microtarget irradiation by the 12 second-harmonic beams ({lambda} = 0.66 {mu}m) of iodine laser radiation carried out on the Iskra-5 facility. For microtargets we employed glass shells {approx}500 {mu}m in diameter with {approx}1-{mu}m thick walls, which were filled with a DT mixture at a pressure p{sub DT} {approx} 3-4 atm. In one of these experiments, a tomographic image of the microtarget was recorded from the images obtained using pinhole cameras, which were arranged along seven different directions. The pinhole images were acquired in the X-ray radiation with photon energies above 1.5 keV. The procedure used for reconstructing the volume luminosity of the microtarget is described. An analysis of the tomographic image suggests that the compressed microtarget domain possesses a complex asymmetric shape; 20-30 {mu}m sized structural elements being clearly visible. The resultant data set allowed us to estimate the initial nonuniformity of microtarget surface irradiation by the laser radiation. The rms nonuniformity of microtarget irradiance was estimated at {approx}60 %. (interaction of laser radiation with targets)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On Using Intensity Interferometry for Feature Identification and Imaging of Remote Objects

We derive an approximation to the intensity covariance function of two scanning pinhole detectors, facing a distant source (e.g., a star) being occluded partially by an absorptive object (e.g., a planet). We focus on using this technique to identify or image an object that is in the line-of-sight between a well-characterized source and the detectors. We derive the observed perturbation to the intensity covariance map due to the object, showing that under some reasonable approximations it is proportional to the real part of the Fourier transform of the source's photon-flux density times the Fourier transform of the object's intensity absorption. We highlight the key parameters impacting its visibility and discuss the requirements for estimating object-related parameters, e.g., its size, velocity or shape. We consider an application of this result to determining the orbit inclination of an exoplanet orbiting a distant star. Finally, motivated by the intrinsically weak nature of the signature, we study its signal-to-noise ratio and determine the impact of system parameters.

quantum optics↗

Energy dispersive detector for white beam synchrotron x-ray fluorescence imaging

A novel, “single-shot” fluorescence imaging technique has been demonstrated on the B16 beamline at the Diamond Light Source synchrotron using the HEXITEC energy dispersive imaging detector. A custom made furnace with 200µm thick metal alloy samples was positioned in a white X-ray beam with a hole made in the furnace walls to allow the transmitted beam to be imaged with a conventional X-ray imaging camera consisting of a 500 µm thick single crystal LYSO scintillator, mirror and lens coupled to an AVT Manta G125B CCD sensor. The samples were positioned 45° to the incident beam to enable simultaneous transmission and fluorescence imaging. The HEXITEC detector was positioned at 90° to the sample with a 50 µm pinhole 13 cm from the sample and the detector positioned 2.3m from pinhole. The geometric magnification provided a field of view of 1.1×1.1mm{sup 2} with one of the 80×80 pixels imaging an area equivalent to 13µm{sup 2}. Al-Cu alloys doped with Zr, Ag and Mo were imaged in transmission and fluorescence mode. The fluorescence images showed that the dopant metals could be simultaneously imaged with sufficient counts on all 80x80 pixels within 60 s, with the X-ray flux limiting the fluorescence imaging rate. This technique demonstrated that it is possible to simultaneously image and identify multiple elements on a spatial resolution scale ~10µm or higher without the time consuming need to scan monochromatic energies or raster scan a focused beam of X-rays. Moving to high flux beamlines and using an array of detectors could improve the imaging speed of the technique with element specific imaging estimated to be on a 1 s timescale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solvent-Mediated Crystallization of CH 3 NH 3 SnI 3 Films for Heterojunction Depleted Perovskite Solar Cells

Organo-lead halide perovskite solar cells have gained enormous significance and have now achieved power conversion efficiencies of ~20%. However, the potential toxicity of lead in these systems raises environmental concerns for widespread deployment. In this work we investigate solvent effects on the crystallization of the lead-free methylammonium tin triiodide (CH 3 NH 3 SnI 3 ) perovskite films in a solution growth process. Highly uniform, pinhole-free perovskite films are obtained from a dimethyl sulfoxide (DMSO) solution via a transitional SnI 2 ·3DMSO intermediate phase. This high-quality perovskite film enables the realization of heterojunction depleted solar cells based on mesoporous TiO 2 layer but in the absence of any hole-transporting material with an unprecedented photocurrent up to 21 mA cm –2 . Charge extraction and transient photovoltage decay measurements reveal high carrier densities in the CH 3 NH 3 SnI 3 perovskite device which are one order of magnitude larger than CH 3 NH 3 PbI 3 -based devices but with comparable recombination lifetimes in both devices. The relatively high background dark carrier density of the Sn-based perovskite is responsible for the lower photovoltaic efficiency in comparison to the Pb-based analogues. These results provide important progress toward achieving improved perovskite morphology control in realizing solution-processed highly efficient lead-free perovskite solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray imaging and electron temperature evolution in laser-driven magnetic reconnection experiments at the national ignition facility

We present results from x-ray imaging of high-aspect-ratio magnetic reconnection experiments driven at the National Ignition Facility. Two parallel, self-magnetized, elongated laser-driven plumes are produced by tiling 40 laser beams. A magnetic reconnection layer is formed by the collision of the plumes. A gated x-ray framing pinhole camera with micro-channel plate detector produces multiple images through various filters of the formation and evolution of both the plumes and current sheet. As the diagnostic integrates plasma self-emission along the line of sight, two-dimensional electron temperature maps ⟨Te⟩Y are constructed by taking the ratio of intensity of these images obtained with different filters. The plumes have a characteristic temperature ⟨Te⟩Y=240 ± 20 eV at 2 ns after the initial laser irradiation and exhibit a slow cooling up to 4 ns. The reconnection layer forms at 3 ns with a temperature ⟨Te⟩Y=280 ± 50 eV as the result of the collision of the plumes. The error bars of the plumes and current sheet temperatures separate at 4 ns, showing the heating of the current sheet from colder inflows. Using a semi-analytical model, we survey various heating mechanisms in the current sheet. We find that reconnection energy conversion would dominate at low density (ne≲7×1018 cm−3) and electron-ion collisional drag at high-density (≳1019 cm−3).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗