Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon emission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Towards the Stable Chelation of Radioantimony(V) for Targeted Auger Theranostics

Abstract Antimony‐119 ( 119 Sb) is one of the most attractive Auger‐electron emitters identified to date, but it remains practically unexplored for targeted radiotherapy because no chelators have been identified to stably bind this metalloid in vivo. In a departure from current studies focused on chelator development for Sb(III), we explore the chelation chemistry of Sb(V) using the tris‐catecholate ligand TREN‐CAM. Through a combination of radiolabeling, spectroscopic, solid‐state, and computational studies, the radiochemistry and structural chemistry of TREN‐CAM with 1XX/nat Sb(V) were established. The resulting [ 1XX Sb]Sb–TREN‐CAM complex remained intact for several days in human serum, signifying high stability under biological conditions. Finally, the first in vivo single photon emission computed tomography and positron emission tomography imaging studies were carried out using 117 Sb, the diagnostic analogue of 119 Sb. These studies revealed marked differences in the uptake and distribution of activity in mice administered unchelated [ 117 Sb]Sb(OH) 6 – versus [ 117 Sb]Sb–TREN‐CAM, suggesting that 117 Sb is largely retained by TREN‐CAM over the time course of the study. Collectively, these findings demonstrate the most physiologically stable complex of no‐carrier‐added 1XX Sb yet reported, offering new promise for the clinical implementation of radioantimony in nuclear medicine. Our results also establish the feasibility of 117 Sb as an elementally matched partner to 119 Sb for theranostic applications.

Olson, Aeli P. [Department of Medical Physics Univ↗

Towards the Stable Chelation of Radioantimony(V) for Targeted Auger Theranostics

Antimony-119 ( 119 Sb) is one of the most attractive Auger-electron emitters identified to date, but it remains practically unexplored for targeted radiotherapy because no chelators have been identified to stably bind this metalloid in vivo. In a departure from current studies focused on chelator development for Sb(III), we explore the chelation chemistry of Sb(V) using the tris-catecholate ligand TREN-CAM. Through a combination of radiolabeling, spectroscopic, solid-state, and computational studies, the radiochemistry and structural chemistry of TREN-CAM with 1XX/nat Sb(V) were established. The resulting [ 1XX Sb]Sb–TREN-CAM complex remained intact for several days in human serum, signifying high stability under biological conditions. Finally, the first in vivo single photon emission computed tomography and positron emission tomography imaging studies were carried out using 117 Sb, the diagnostic analogue of 119 Sb. These studies revealed marked differences in the uptake and distribution of activity in mice administered unchelated [ 117 Sb]Sb(OH) 6 – versus [ 117 Sb]Sb–TREN-CAM, suggesting that 117 Sb is largely retained by TREN-CAM over the time course of the study. Collectively, these findings demonstrate the most physiologically stable complex of no-carrier-added 1XX Sb yet reported, offering new promise for the clinical implementation of radioantimony in nuclear medicine. In conclusion, our results also establish the feasibility of 117 Sb as an elementally matched partner to 119 Sb for theranostic applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical Properties of Low‐Defect Large‐Area Hexagonal Boron Nitride for Quantum Applications

Intrinsic defects and their concentrations in hexagonal boron nitride (h-BN) play a key role in single-photon emission. In this study, the optical properties of large-area multilayer h-BN-on-sapphire grown by metal-organic chemical vapor deposition are explored. Based on the detailed spectroscopic characterization using both cathodoluminescence (CL) and photoluminescence (PL) measurements, the material is devoid of random single-point defects instead of a few clustered complex defects. The emission spectra of the measurements confirm a record-low-defect concentration of ≈10 4 cm −2 . Post-annealing, no significant changes are observed in the measured spectra and the defect concentrations remain unaltered. Through CL and PL spectroscopy, an optically active boron vacancy spin defect is identified and a novel complex defect combination arising from carbon impurities is revealed. This complex defect, previously unreported, signifies a unique aspect of the material. In these findings, the understanding of defect-induced optical properties in h-BN films is contributed, providing insights for potential applications in quantum information science.

42 ENGINEERING↗

Sterile neutrino dark matter within the ν SMEFT

Sterile neutrinos with masses at the keV scale and mixing to the active neutrinos offer an elegant explanation of the observed dark matter (DM) density. However, the very same mixing inevitably leads to radiative photon emission and the non-observation of such peaked X-ray lines rules out this minimal sterile neutrino DM hypothesis. We show that in the context of the Standard Model effective field theory with sterile neutrinos (νSMEFT), higher dimensional operators can produce sterile neutrino DM in a broad range of parameter space. In particular, νSMEFT interactions can open the large mixing parameter space due to their destructive interference, through operator mixing or matching, in the X-ray emission. We also find that, even in the zero mixing limit, the DM density can always be explained by νSMEFT operators. The testability of the studied νSMEFT operators in searches for electric dipole moments, neutrinoless double beta decay, and pion decay measurements is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Validation of the TOPAS Monte Carlo toolkit for HDR brachytherapy simulations

The goal of this work is to validate the user-friendly Geant4-based Monte Carlo toolkit TOol for PArticle Simulation (TOPAS) for brachytherapy applications. Brachytherapy simulations performed with TOPAS were systematically compared with published TG-186 reference data. The photon emission energy spectrum, the air-kerma strength, and the dose-rate constant of the model-based dose calculation algorithm (MBDCA)-WG generic Ir-192 source were extracted. For dose calculations, a track-length estimator was implemented. Additionally, the four Joint AAPM/ESTRO/ABG MBDCA-WG test cases were evaluated through histograms of the local and global dose difference volumes. A prostate, a palliative lung, and a breast case were simulated. For each case, the dose ratio map, the histogram of the global dose difference volume, and cumulative dose-volume histograms were calculated. The air-kerma strength was (9.772 ± 0.001) × 10 -8 U Bq -1 (within 0.3% of the reference value). The dose-rate constant was 1.1107 ± 0.0005 cGy h -1 U -1 (within 0.01% of the reference value). For all cases, at least 96.9% of voxels had a local dose difference within [-1%, 1%] and at least 99.9% of voxels had a global dose difference within [-0.1%, 0.1%]. The implemented track-length estimator scorer was more efficient than the default analog dose scorer by a factor of 237. For all clinical cases, at least 97.5% of voxels had a global dose difference within [-1%, 1%]. Dose-volume histograms were consistent with the reference data. TOPAS was validated for high-dose-rate brachytherapy simulations following the TG-186 recommended approach for MBDCAs. Built on top of Geant4, TOPAS provides broad access to a state-of-the-art Monte Carlo code for brachytherapy simulations.

59 BASIC BIOLOGICAL SCIENCES↗

Concentric core-shell tracks and spectroscopic properties of SrTiO 3 under intense electronic excitation

A deeper understanding of the intrinsic link between the irradiation-induced microstructures and the corresponding spectroscopic properties is becoming increasingly attractive for the research fields of materials science, physics, and information technology. In this work, the structural damage response, spectroscopic features, and associated physical mechanisms of SrTiO 3 single crystals under swift heavy ion irradiation were comparatively analyzed using a combination of experimental and theoretical approaches. Corresponding to 0.11–5.00 MeV/u ion irradiation with electronic energy loss ranging from 4.0 to 29.3 keV/nm, the inelastic thermal spike calculations combined with molecular dynamics simulations are compared with the experimental observations, revealing the track fine structures (individual spherical defects with a disordered region, and discontinuous and continuous tracks consisting of an amorphous core and a disordered outer shell) and demonstrating the dominant effects of the deposition energy and lattice temperature on track damage formation and evolution; thus, two essential thresholds for defect formation of ~0.60 eV/atom and amorphous region formation of ~1.81 eV/atom were identified to better describe the concentric core-shell track structure. The enhanced nanohillock formation in the surface region is attributed to the combined action of kinetic and potential energy depositions, and the fluence dependence in regulating the hillock dimensions is also presented. The measured refractive index profiles along different crystal axes further indicate the anisotropy of irradiation-induced lattice expansion. With increasing ion fluence and damage level, the intrinsic bandgap gradually decreased, and the concentration of additional radiative recombination centers (1.81 eV, 2.31 eV, and 2.42 eV) accordingly increased in the SrTiO 3 crystal, providing the possibility of regulating related defects to achieve tunable/selective photon emission for more critical technological applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The effectiveness of D 2 pellet and gas injection in reducing intra-ELM tungsten erosion and heat flux in the DIII-D small angle slot divertor

Edge localized modes (ELMs) in H-mode plasmas can melt and erode plasma-facing components (PFCs) and lead to impurities in the core, reducing confinement. This study analyzes the use of D 2 pellet and gas injection for ELM mitigation on the DIII-D tokamak during the 2022 Small Angle Slot V-shaped Tungsten (W) (SAS-VW) divertor campaign, reducing W erosion and heat flux during ELMs. D α (656 nm) and WI (400.9 nm) filterscopes and Langmuir probes provide photon emission and electron density/temperature to estimate W atom erosion using the S/XB method, while surface eroding thermocouples measured ELM peak heat flux at the outer strike point (OSP). Thomson Scattering measurements of pedestal T e and n e provided input to predict W divertor erosion and heat flux during ELMs via the Free-Streaming plus Recycling Model (FSRM). While a greater D 2 mass injection rate decreased the ELM peak heat flux, the impact on W erosion was not monotonic. The average ‘large’ intra-ELM W erosion was lower for plasma shots with D 2 mass injection compared to the plasma shots without any D 2 mass injection in the SAS-VW divertor. However, plasma shots did not see significant changes in ‘large’ intra-ELM W divertor erosion as the D 2 mass injection rate increased. On average, the FSRM overestimated SAS-VW experimental intra-ELM W erosion by a factor of 6.9, but the overestimation is reduced to a factor of 3.6 with the implication of C deposition effects. Generally, experimentally measured and predicted quantities were worse for plasma shots with a lower D 2 mass injection rate and corresponding higher plasma carbon (C) impurity percentage (f C ). The discrepancies are postulated to be due to C/W material mixing, for which a simple analytic mixed-material model is presented. These results highlight the importance of incorporating and improving the robustness of a mixed-material layer model in the analysis of PFC erosion on present and future tokamak devices.

Carbon (C)↗

Quantum simulations of dark sector showers

We consider dark sector scenarios where dark matter is accompanied by a dark photon and multiple-flavor dark fermions charged under the dark gauge group. We study quantum interference effects in dark sector jets, where multiple dark photons are emitted from high-energy dark fermions. We perform fully quantum simulations of dark sector showers and compare the results against those of the classical Monte-Carlo simulations. We find important differences in probability distributions of dark photon countings between quantum and classical computations. When the number of dark-fermion flavors is large, we find significant enhancements in large numbers of dark photon emissions. Such enhancements can provide distinguishing signals for our scenarios at particle colliders.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Broken Symmetry Optical Transitions in (6,5) Single-Walled Carbon Nanotubes Containing sp 3 Defects Revealed by First-Principles Theory

We present a first-principles many-body perturbation theory study of nitrophenyl-doped (6,5) single-walled nanotubes (SWCNTs) to understand how sp 3 doping impacts the excitonic properties. sp 3 -doped SWCNTs are promising as a class of optoelectronic materials with bright tunable photoluminescence, long spin coherence, and single-photon emission (SPE), motivating the study of spin excitations. We predict that the dopant results in a single unpaired spin localized around the defect site, which induces multiple low-energy excitonic peaks. By comparing optical absorption and photoluminescence from experiment and theory, we identify the transitions responsible for the red-shifted, defect-induced E 11 * peak, which has demonstrated SPE for some dopants; the presence of this state is due to both the symmetry-breaking associated with the defect and the presence of the defect-induced in-gap state. Furthermore, we find an asymmetry between the contribution of the two spin channels, suggesting that this system has potential for spin-selective optical transitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strain-Induced Growth of Twisted Bilayers during the Coalescence of Monolayer MoS 2 Crystals

Tailoring the grain boundaries (GBs) and twist angles between two-dimensional (2D) crystals are two crucial synthetic challenges to deterministically enable envisioned applications such as moiré excitons, emerging magnetism, or single-photon emission. Here, we reveal how twisted 2D bilayers can be synthesized from the collision and coalescence of two growing monolayer MoS 2 crystals during chemical vapor deposition. The twisted bilayer (TB) moiré angles are found to preserve the misorientation angle (θ) of the colliding crystals. The shapes of the TB regions are rationalized by a kink propagation model that predicts the GB formed by the coalescing crystals. Optical spectroscopy measurements reveal a θ-dependent long-range strain in crystals with stitched grain boundaries and a sharp (θ > 20°) threshold for the appearance of TBs, which relieves this strain. Reactive molecular dynamics simulations explain this strain from the continued growth of the crystals during coalescence due to the insertion of atoms at unsaturated defects along the GB, a process that self-terminates when the defects become saturated. The simulations also reproduce atomic-resolution electron microscopy observations of faceting along the GB, which is shown to arise from the growth-induced long-range strain. These facets align with the axes of the colliding crystals to provide favorable nucleation sites for second-layer growth of a TB with twist angles that preserve the misorientation angle θ. This interplay between strain generation and aligned nucleation provides a synthetic pathway for the growth of TBs with deterministic angles.

2D materials↗

Ligand Controls Excited Charge Carrier Dynamics in Metal-Rich CdSe Quantum Dots: Computational Insights

Small metal-rich semiconducting quantum dots (QDs) are promising for solid-state lighting and single-photon emission due to their highly tunable yet narrow emission line widths. Nonetheless, the anionic ligands commonly employed to passivate these QDs exert a substantial influence on the optoelectronic characteristics, primarily owing to strong electron–phonon interactions. In this work, we combine time-domain density functional theory and nonadiabatic molecular dynamics to investigate the excited charge carrier dynamics of Cd 28 Se 17 X 22 QDs (X = HCOO – , OH – , Cl – , and SH – ) at ambient conditions. These chemically distinct but regularly used molecular groups influence the dynamic surface-ligand interfacial interactions in Cd-rich QDs, drastically modifying their vibrational characteristics. The strong electron–phonon coupling leads to substantial transient variations at the band edge states. The strength of these interactions closely depends on the physicochemical characteristics of passivating ligands. Consequently, the ligands largely control the nonradiative recombination rates and emission characteristics in these QDs. Our simulations indicate that Cd 28 Se 17 (OH) 22 has the fastest nonradiative recombination rate due to the strongest electron–phonon interactions. Conversely, QDs passivated with thiolate or chloride exhibit considerably longer carrier lifetimes and suppressed nonradiative processes. The ligand-controlled electron–phonon interactions further give rise to the broadest and narrowest intrinsic optical line widths for OH and Cl-passivated single QDs, respectively. Finally, obtained computational insights lay the groundwork for designing appropriate passivating ligands on metal-rich QDs, making them suitable for a wide range of applications, from blue LEDs to quantum emitters.

36 MATERIALS SCIENCE↗

Correlated Lattice Fluctuations in CsPbBr 3 Quantum Dots Give Rise to Long-Lived Electronic Coherence

Electronic coherence is central to numerous areas of science, from quantum biology to quantum materials. In quantum materials, lead-halide perovskite (LHP) quantum dots (QDs) have been shown to support electronic coherence through observation of coherent single-photon emission and superfluorescence arising from spatial coherence at low temperatures. In contrast, direct measurement of temporal coherence between exciton states has been lacking. Here, we employ coherent multi-dimensional spectroscopy to observe an electronic coherence between exciton states in CsPbBr 3 QDs that is long-lived at room temperature, surviving nearly three times longer than the electronic dephasing time. This observation of a long-lived electronic coherence at room temperature points to nearly perfectly correlated lattice fluctuations for each excitonic state in the superposition. In conclusion, these experiments reveal that the properties of LHP QDs extend to lattice dynamics that give rise to correlated fluctuations in the basis exciton states, a process that may next be optimized by design.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum Emitters Induced by High Pressure and UV Laser Irradiation in Multilayer GaSe

In this work, we report on defect generation in multilayer GaSe through hydrostatic pressure quenching and UV laser irradiation. The Raman line width from the UV 266 nm irradiated sample is much wider than that in pressure-quenched GaSe, corresponding to a wider defect energy distribution range in the former sample than the latter. After quenching from 11.2 GPa, three photoluminescence (PL) peaks from defect states are observed at 657, 681, and 695 nm at a low temperature of 93 K. Defect-related peaks at 649, 694, 750, and 774 nm also appear in low-temperature PL spectra after UV laser irradiation, with a nonmonotonous intensity dependence on irradiation duration. There are common features in defects produced by these two methods: the PL peaks with the lowest energy are sharp, and their PL intensities increase linearly with the excitation laser power and saturate above a certain excitation laser power. These two features are similar to those in defects for single-photon emission (SPE) in other 2D materials at even lower temperatures. Fluorescence lifetime imaging shows distinguished short (2.3 ns) and long (75.6 nm) lifetimes of the 695 nm PL line in pressure-quenched GaSe. The density functional theory predicts defect energy levels related to Se vacancy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production and Purification of Terbium-155 Using Natural Gadolinium Targets

Terbium-155 (t 1/2 = 5.32 days) is one of four medically relevant radioisotopes of terbium. It is of interest to the field as a suitable diagnostic counterpart for therapeutic radiolanthanides, as its decay scheme includes γ-rays that are suitable for single photon emission computed tomography (SPECT) imaging. Additionally, 155 Tb has an Auger electron (AE) yield that is viable for AE therapy. There are several direct and indirect production routes that can produce 155 Tb. Two possible direct routes include proton irradiation on gadolinium targets via 155 Gd(p,n) 155 Tb and 156 Gd(p,2n) 155 Tb. The 155 Gd(p,n) 155 Tb reaction is accessible at incident proton beam energies of ∼10 MeV, whereas the 156 Gd(p,2n) 155 Tb nuclear reaction requires ∼18 MeV. This study aims to investigate the production of 155 Tb from natGd through the nat Gd(p,x) nuclear reaction, wherein both (p,n) and (p,2n) reactions were leveraged, and the purification using a three-column ion chromatography method. Using this system, recoveries of radioterbium of up to 97% were achieved in addition to high recoveries of the Gd target material, illustrating the suitability of this technique for enriched targets.

36 MATERIALS SCIENCE↗

Thermodynamics and Mechanism of a Photocatalyzed Stereoselective [2 + 2] Cycloaddition on a CdSe Quantum Dot

Colloidal quantum dots (QDs) have shown promise over the last few decades for a range of applications including single photon emission, in vivo imaging and photocatalysis. Recent experiments demonstrated that QDs impart stereoselectivity to triplet excited-state [2+2] cycloaddition reactions of alkenes photocatalyzed by the QD through self-assembly of the reagent molecules on the QD surface, but these experiments did not reveal the precise geometries of surface-bound molecules or their interactions with surface atoms. Here, a theoretical mechanistic approach is used to study such interactions for [2+2] cycloadditions of 4-vinylbenzoic acid derivatives on CdSe QDs. Spin-polarized periodic density functional theory (DFT) and non-periodic DFT calculations are deployed to determine the origin of the selectivity for the syn diastereomer of the resultant tetrasubstituted cyclobutane product via atomistic modelling of the CdSe surface and substrates, and determination of the thermodynamic energies of reactions for each step, the intermolecular interactions between the substrates, and the triplet state reaction paths. The calculations indicate that reaction selectivity arises from preferred binding of pairs through intermolecular interactions of substrate molecules on the QD surface in a syn-precursor structure followed by dimerization after triplet excitation. Further, these mechanisms are generalizable to other metal-enriched QD surfaces that have a similar surface structure to CdSe, such as InSe or CdTe. Design principles for anti diastereomer derivatives are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗