Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Road to PROSPECT-II

The Precision Reactor Oscillation and SPECTrum (PROSPECT) experiment is based in a segmented liquid scintillator antineutrino detector situated approximately 7 meters from the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Its main goal is to investigate short-baseline antineutrino oscillations. The first phase of data collection, known as PROSPECT-I, was held from 2018 to 2019 and was used for several high-precision analyses, including multiple measurements of the $^{235}U$ antineutrino spectrum and searches for $eV$-scale sterile antineutrino oscillations. The collaboration is now preparing for the second phase, PROSPECT-II, which features an upgraded detector design. This advancement will enhance sensitivity and statistical power, allowing for a broader range of analyses beyond those achieved in PROSPECT-I. As we transition into this new phase, new questions have arisen concerning background simulation and its potential differences from those conducted during the initial phase of the experiment. Moreover, it is essential to ascertain, through simulations, the positive effects that an improved detector could have on the study of oscillations. This information is crucial for justifying the proposed enhancements, and I will cover all of this in the talk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Road to PROSPECT-II

The Precision Reactor Oscillation and SPECTrum (PROSPECT) experiment is based in a segmented liquid scintillator antineutrino detector situated approximately 7 meters from the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Its main goal is to investigate short-baseline antineutrino oscillations. The first phase of data collection, known as PROSPECT-I, was held from 2018 to 2019 and was used for several high-precision analyses, including multiple measurements of the $^{235}U$ antineutrino spectrum and searches for $eV$-scale sterile antineutrino oscillations. The collaboration is now preparing for the second phase, PROSPECT-II, which features an upgraded detector design. This advancement will enhance sensitivity and statistical power, allowing for a broader range of analyses beyond those achieved in PROSPECT-I. As we transition into this new phase, new questions have arisen concerning background simulation and its potential differences from those conducted during the initial phase of the experiment. Moreover, it is essential to ascertain, through simulations, the positive effects that an improved detector could have on the study of oscillations. This information is crucial for justifying the proposed enhancements, and I will cover all of this in the talk.

43 PARTICLE ACCELERATORS↗

Multi-phase characterization of pitch-carbon coated nano-silicon anodes for lithium-ion batteries

Silicon (Si) is a leading next-generation Li-ion battery anode candidate that meets rigorous performance demands for portable power including enhanced power and energy density with robust cycling performance. However, a series of complex and interrelated reactions lead to reduced calendar life in Si-containing systems and therefore challenge practical adoption. In the present work, we probe the mechanisms underlying observed performance improvements by adding a pitch-carbon coating onto nano-Si material. We pair solid-phase (X-ray photoemission spectroscopy, Fourier-transform infrared), semi-volatile phase (solid-phase microextraction-gas chromatography-mass spectrometry), and gas-phase (gas chromatography-flame-ionization detector) characterization signals to comprehensively evaluate the impact of pitch-carbon coating on the evolution of the Si solid-electrolyte interphase (SEI) and the associated impacts on electrode/electrolyte reactivity. The pitch-carbon is found to serve as a physicochemical barrier, reducing the electro-active surface area for Si/electrolyte reactivity and preventing Si oxidation. Further, the pitch-carbon coating promotes the evolution of a more-favorable SEI by subsuming substantial functionality typically associated with the fluoroethylene carbonate (FEC) electrolyte additive - such as alkoxide scavenging and suppression of transesterification pathways - and by shifting the competitive electrolyte degradation pathways' favorability. The multi-phase characterization approach enables holistic end-products evaluation from complex (electro)chemical interfacial reactions, which informs a robust interpretation of the carbon coating's role in electrochemical performance improvements. The present mechanistic evaluation aids the rational design for improved nano-Si materials.

25 ENERGY STORAGE↗

Phase transformation and growth mechanism of RF sputtered ferroelectric lead scandium tantalate (PbSc 0.5 Ta 0.5 O 3 ) films

Lead scandium tantalate (PbSc 0.5 Ta 0.5 O 3 , PST), an order/disorder ferroelectric, is a potential candidate for electrocaloric cooling and pyroelectric infrared (IR) detector. In this work, we report the phase transformation kinetics from two series of samples containing pure amorphous and mixture of amorphous and pyrochlore to desired perovskite phase using postdeposition rapid thermal processing (RTP) as well as growth mechanism of RF sputtered PST thin films using excess lead target on platinized silicon (Pt/Ti/SiO 2 /Si) substrates. We find that small changes in the temperature ramp have a large effect on the degree of perovskite conversion (ferroelectric phase), orientation (crystallographic texture), and long-range order parameter (< S 111 >). Through isothermal annealing, we obtained optimal perovskite phase at ≥700°C temperature. The phase transformation is characterized by spontaneous formation of center-type in-plane radial rosette-like structures revealed by scanning electron microscopy. The PST perovskite crystallites were found to coexist with pyrochlore in RTP annealed films. The volume fractions for perovskite and pyrochlore phase were obtained from the analysis of “rosettes” and respective X-ray diffraction intensities which helped to determine various parameters associated with phase kinetics (n, k, and activation energy, Ea) and accompanying growth. The effective activation energies of perovskite transition and growth were found to be 332 ± 11 kJ/mol (345 ± 11 kJ/mol) and 114 ± 10 kJ/mol (122 ± 10 kJ/mol), respectively, for pure amorphous only (and mixed amorphous and pyrochlore) phase following nucleation-growth controlled Avrami's equation. A linear growth rate (n~1) for the perovskite phase indicates predominant interface-controlled process and diffusion-limited phenomena thus inhibiting rosette size owing to reactant depletion and soft impingement at the grain boundary. However, the growth behavior is isotropic in two-dimension parallel to the plane of the substrates for both sample series. Furthermore, lead loss was severe for in-situ growth and RTP combined with conventional furnace annealing than those of RTP only films, which were closer to stoichiometric albeit with excess lead and marginal oxygen vacancies (V o ).

36 MATERIALS SCIENCE↗

Harnessing the power of an X-ray laser for serial crystallography of membrane proteins crystallized in lipidic cubic phase

Serial femtosecond crystallography (SFX) with X-ray free-electron lasers (XFELs) has proven highly successful for structure determination of challenging membrane proteins crystallized in lipidic cubic phase; however, like most techniques, it has limitations. Here we attempt to address some of these limitations related to the use of a vacuum chamber and the need for attenuation of the XFEL beam, in order to further improve the efficiency of this method. Using an optimized SFX experimental setup in a helium atmosphere, the room-temperature structure of the adenosine A 2A receptor (A 2A AR) at 2.0 Å resolution is determined and compared with previous A 2A AR structures determined in vacuum and/or at cryogenic temperatures. Specifically, the capability of utilizing high XFEL beam transmissions is demonstrated, in conjunction with a high dynamic range detector, to collect high-resolution SFX data while reducing crystalline material consumption and shortening the collection time required for a complete dataset. The experimental setup presented herein can be applied to future SFX applications for protein nanocrystal samples to aid in structure-based discovery efforts of therapeutic targets that are difficult to crystallize.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the mean excitation energy of liquid argon

The mean excitation energy (I-value) of liquid argon is a critical input for energy estimation in neutrino oscillation experiments. It is measured to be 199 +4 -5 eV using the range of 402.2 MeV protons from the Fermilab Linac. This compares to the author's recent evaluation of (197 ± 7) eV based on a combination of an oscillator strength distribution analysis, gaseous argon range measurements, sparse stopping power data on solid argon, and an extrapolation of data on the effect of phase from other substances. Using all sources of information, we recommend a value of (198 ± 4) eV for liquid argon, which is significantly higher than 188 eV, from ICRU-37's gaseous argon evaluation, commonly used in Monte Carlo codes such as Geant4.

47 OTHER INSTRUMENTATION↗

High Yield Xray Imager Final Design Review

The High Yield Xray Imager (HYXI) is a new NIF target diagnostic system currently under development. The goal of HYXI is to provide high-fidelity, high temporal resolution x-ray imaging capability on high yield NIF implosions at 10MJ and above. The HYXI instrument design concept is based on the combination of two technologies that have been successfully utilized at the NIF on previous instruments, electron pulse-dilation and hybrid-CMOS sensor imaging. The combination of these two techniques will give HYXI sufficient data quality to ascertain differences in hot spot formation dynamics between high and low yield implosions. This information will highlight the critical hot spot conditions needed for ignition and burn. The HYXI design leverages the successful operation of the PDIXI x-ray imager at the NIF on multi MJ yield shots. A new radiation tolerant CMOS imaging array (HYPERION) is being developed to eliminate the significant background noise which limits the data quality of PDIXI. We successfully placed the contract with Advanced hCMOS Systems (AHS) to develop the HYPERION sensor, which fulfils our criteria to place long lead time item procurements by end of FY24. The HYXI Final Design Review was completed at the end of Q4 FY24 (Sep 24 th and Sep 30 th ). The HYXI project is a multi-year effort with a phased approach to be bring up system functionality over time in parallel with the development and fabrication effort of the HYPERION CMOS imaging array. In Phase 1, time-integrated x-ray images on NIF DT experiments will be collected starting in Q3 FY25. In Phase 2 of the project, time-resolved imaging with HYXI utilizing a spare microchannel plate detector back-end will begin in Q3 FY26. Phase 3 concludes the project with the installation of the HYPERION sensor array and the final performance qualification of the HYXI instrument which is scheduled for Q3 FY27 as discussed in the PDR and MRT report on this project in FY23.

42 ENGINEERING↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

A method to determine the electric field of liquid argon time projection chambers using a UV laser system and its application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are now a standard detector technology for making accelerator neutrino measurements, due to their high material density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to 2020 JINST 15 P07010 drift ionization electrons to the anode where they are collected. The E-field of a TPC is often approximated to be uniform between the anode and the cathode planes. However, significant distortions can appear from effects such as mechanical deformations, electrode failures, or the accumulation of space charge generated by cosmic rays. The latter effect is particularly relevant for detectors placed near the Earth’s surface and with large drift distances and long drift time. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The 3×1×1 m3 demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performance of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Dark Matter Search Results from the LUX-ZEPLIN (LZ) Experiment

The LUX-ZEPLIN experiment is a dark matter detector centered on a dual-phase xenon time projection chamber operating at the Sanford Underground Research Facility in Lead, South Dakota, USA. This Letter reports results from LUX-ZEPLIN's first search for weakly interacting massive particles (WIMPs) with an exposure of 60~live days using a fiducial mass of 5.5 t. A profile-likelihood ratio analysis shows the data to be consistent with a background-only hypothesis, setting new limits on spin-independent WIMP-nucleon, spin-dependent WIMP-neutron, and spin-dependent WIMP-proton cross sections for WIMP masses above 9 GeV/c 2 . The most stringent limit is set for spin-independent scattering at 36 GeV/c 2 , rejecting cross sections above 9.2×10 –48 cm 2 at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

STEM Ptychographic Holography of Electric and Magnetic Potentials

The development of fast an efficient direct electron imaging detectors have enabled the advancement of phase-imaging techniques in STEM such as iterative ptychography. As beneficial as these techniques are to imaging phase objects, the information recorded in the raw data is due to phase gradients across the probe, so it can be challenging to reconstruct slowly varying phase at lower spatial frequencies such as those induced by electric or magnetic potentials within the specimen. STEM holography [1,2] is an interferometric 4D-STEM technique where electrons in the beam are coherently divided into a superposition of two or more spatially separated probes which are then scanned over the specimen. For example, in a two-beam superposition, the two probes form overlapping bright field discs at the detector which then interfere (left of Fig. 1). Furthermore, if one probe passes through vacuum while the other transmits through the specimen, the resulting relative phase shift can be measured by recording shifts in the interference pattern. STEM holography is thus directly sensitive to the phase of the probe relative to the reference beam, and this phase can be measured regardless of the convergence angle of the probe, unlike single beam ptychography.

Biological Sciences↗

Improved modeling of β electronic recoils in liquid xenon using LUX calibration data

We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the $\beta$ decays of ${}^3$H and ${}^{14}$C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0, while also providing the final electronic recoil model and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the neutrino-oxygen neutral-current quasielastic cross section using atmospheric neutrinos in the SK-Gd experiment

We report the first measurement of the atmospheric neutrino-oxygen neutral-current quasielastic (NCQE) cross section in the gadolinium-loaded Super-Kamiokande (SK) water Cherenkov detector. In June 2020, SK began a new experimental phase, named SK-Gd, by loading 0.011% by mass of gadolinium into the ultrapure water of the SK detector. The introduction of gadolinium to ultrapure water has the effect of improving the neutron-tagging efficiency. Using a 552.2 day dataset from August 2020 to June 2022, we measure the NCQE cross section to be 0.74 ± 0.22 ( stat ) − 0.15 + 0.85 ( syst ) × 10 − 38 cm 2 / oxygen in the energy range from 160 MeV to 10 GeV, which is consistent with the atmospheric neutrino-flux-averaged theoretical NCQE cross section and the measurement in the SK pure-water phase within the uncertainties. Furthermore, we compare the models of the nucleon-nucleus interactions in water and find that the binary cascade model and the Liège intranuclear cascade model provide a somewhat better fit to the observed data than the Bertini cascade model. Since the atmospheric neutrino-oxygen NCQE reactions are one of the main backgrounds in the search for diffuse supernova neutrino background (DSNB), these new results will contribute to future studies—and the potential discovery—of the DSNB in SK. Published by the American Physical Society 2024

Sakai, S. (ORCID:0000000221900062)↗

The ABC130 barrel module prototyping programme for the ATLAS strip tracker

For the Phase-II Upgrade of the ATLAS Detector [1], its Inner Detector, consisting of silicon pixel, silicon strip and transition radiation sub-detectors, will be replaced with an all new 100% silicon tracker, composed of a pixel tracker at inner radii and a strip tracker at outer radii. The future ATLAS strip tracker will include 11,000 silicon sensor modules in the central region (barrel) and 7,000 modules in the forward region (end-caps), which are foreseen to be constructed over a period of 3.5 years. The construction of each module consists of a series of assembly and quality control steps, which were engineered to be identical for all production sites. In order to develop the tooling and procedures for assembly and testing of these modules, two series of major prototyping programs were conducted: an early program using readout chips designed using a 250 nm fabrication process (ABCN-250) [2,2] and a subsequent program using a follow-up chip set made using 130 nm processing (ABC130 and HCC130 chips). This second generation of readout chips was used for an extensive prototyping program that produced around 100 barrel-type modules and contributed significantly to the development of the final module layout. This paper gives an overview of the components used in ABC130 barrel modules, their assembly procedure and findings resulting from their tests.

47 OTHER INSTRUMENTATION↗

Search for neutron decay into an antineutrino and a neutral kaon in 0.401 megaton-years exposure of Super-Kamiokande

We searched for bound neutron decay via 𝑛 → $\bar{𝜈}$ +𝐾 0 predicted by the grand unified theories in 0.401 Mton·years exposure of all pure water phases in the Super-Kamiokande detector. About 4.4 times more data than in the previous search have been analyzed by a new method including a spectrum fit to kaon invariant mass distributions. No significant data excess has been observed in the signal regions. As a result of this analysis, we set a lower limit of 7.8 × 10 32 years on the neutron lifetime at a 90% confidence level.

Cherenkov detectors↗

Probing Boron Vacancy Complexes in h-BN Semi-Bulk Crystals Synthesized by Hydride Vapor Phase Epitaxy

Hexagonal BN (h-BN) has emerged as an important ultrawide bandgap (UWBG) semiconductor (Eg~6 eV). The crystal growth technologies for producing semi-bulk crystals/epilayers in large wafer sizes and understanding of defect properties lag decades behind conventional III-nitride wide bandgap (WBG) semiconductors. Here we report probing of boron vacancy (VB)-related defects in freestanding h-BN semi-bulk wafers synthesized by hydride vapor phase epitaxy (HVPE). A photocurrent excitation spectroscopy (PES) was designed to monitor the transport of photoexcited holes from deep-level acceptors. A dominant transition line at 1.66 eV with a side band near 1.62 eV has been directly observed, which matches well with the calculated energy levels of 1.65 for the VB-H deep acceptor in h-BN. The identification of VB complexes via PES measurement was further corroborated by the temperature-dependent dark resistivity and secondary ion mass spectrometry measurements. The results presented here suggested that it is necessary to focus on the optimization of V/III ratio during HVPE growth to minimize the generation of VB-related defects and to improve the overall material quality of h-BN semi-bulk crystals. The work also provided a better understanding of how VB complexes behave and affect the electronic and optical properties of h-BN.

36 MATERIALS SCIENCE↗