Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The XRS Low Temperature Cryogenic System: Ground Performance Test Results

The X-Ray Spectrometer (XRS) instrument is part of the Astro-E mission scheduled to launch early in 2000. Its cryogenic system is required to cool a 32-element square array of x-ray microcalorimeters to 60-65 mK over a mission lifetime of at least 2 years. This is accomplished using an adiabatic demagnetization refrigerator (ADR) contained within a two-stage superfluid helium/solid neon cooler. Goddard Space Flight Center is providing the ADR and helium dewar. The flight system was assembled in Sept. 1997 and subjected to extensive thermal performance tests. This paper presents test results at both the system and component levels. In addition, results of the low temperature topoff performed in Japan with the engineering unit neon and helium dewars are discussed.

Breon, Susan↗

Performance Testing of a Photocatalytic Oxidation Module for Spacecraft Cabin Atmosphere Revitalization

Photocatalytic oxidation (PCO) is a candidate process technology for use in high volumetric flow rate trace contaminant control applications in sealed environments. The targeted application for PCO as applied to crewed spacecraft life support system architectures is summarized. Technical challenges characteristic of PCO are considered. Performance testing of a breadboard PCO reactor design for mineralizing polar organic compounds in a spacecraft cabin atmosphere is described. Test results are analyzed and compared to results reported in the literature for comparable PCO reactor designs.

Perry, Jay L.↗

Performance tests of a gas blending system based on mass-flow controllers

The system provides many of the gas mixtures required for calibrating analytical instruments used in engine exhaust gas analysis and is capable of blending from one to four additive gases with either of two carrier gases in concentrations from 20 ppm to 50%. Two mixtures can be flowing simultaneously. Performance tests were made to determine the stability accuracy of the system while it was in limited use for a period of 2 years. The accuracy of the blender was measured by comparing binary mixtures from the blender with National Bureau of Standards standard reference materials. Analytical instruments were used to make these comparisons. The expected accuracy of 2% was obtained in some of the tests, by the majority showed a systematic biAs of -5%. Although these tests revealed subtle instabilities in the flow controllers that contributed to the random scatter of data, the accuracy of wet test meters and bubble flowmeters used for calibration is marginal for this purpose. A simple procedure is recommended that should enable the full potential of the system to be realized.

Evans, A., Jr.↗

Performance Testing of Yardney MCMB-LiNiCoAlO2 Lithium-ion Cells Possessing Electrolytes with Improved Safety Characteristics

Many future NASA missions aimed at exploring the Moon and Mars require high specific energy rechargeable batteries that possess enhanced safety characteristics. There is also a strong desire to develop Li-ion batteries with improved safety characteristics for terrestrial applications, most notably for HEV and PHEV automotive applications. In previous work focused upon evaluating various potential flame retardant additives1, triphenyl phosphate (TPP)2 was observed to have the most desirable attributes, including good life characteristics and resilience to high voltage operation. We have employed a number of approaches in the design of promising TPP-based electrolytes with improved safety, including: (a) varying the flame retardant additive (FRA) content (from 5 to 15%), (b) the use of fluorinated co-solvents, (c) the use of additives to improve compatibility, and (c) the use of ester co-solvents to decrease the viscosity and increase the conductivity. In recent work, we have demonstrated a number of these electrolyte formulations to be compatible with a number of chemistries, including: MCMB carbon-LiNi0.8Co0.2O2, graphite-LiNi0.8Co0.15Al0.05O2, Li-Li(Li0.17Ni 0.25 Mn 0.58 )O2, Li-LiNiCoMnO2 and graphite- LiNiCoMnO2.3,4 In the current study, we have demonstrated the performance of a number of TPP-containing electrolytes in 7 Ah prototype MCMB-LiNiCoO2 cells. We will describe the results of a number of performance tests, including: a) 100% DOD cycle life testing at various temperatures, b) discharge rate characterization as a function of temperature, c) charge rate characterization as a function of temperature, and d) impedance as a function of temperature. In addition to displaying good life characteristics, being comparable to baseline chemistries, a number of cells were observed to provide good performance over a wide temperature range.

Li-ion batteries↗

Initial results of sensitivity tests - Performed on the RE-1000 free-piston Stirling engine

Tests have been performed over several years to investigate the dynamics of a free-piston Stirling engine for the purpose of computer code validation. Tests on the 1 kW (1.33 hp) single cylinder engine have involved the determination of the sensitivity of the engine performance to variations in working space pressure, heater and cooler temperatures, regenerator porosity, power piston mass, and displacer dynamics. Maps of engine performance have been recorded with the use of an 81.2 percent porosity regenerator. Both a high-efficiency displacer and a high-power displacer were tested; efficiencies up to 33 percent were recorded, and power output of approximately 1500 W was obtained. Preliminary results of the sensitivity tests are presented, and descriptions of future tests are given.

Schreiber, J. G.↗

Performance Testing of Yardney Li-Ion Cells and Batteries in Support of Future NASA Missions

NASA requires lightweight rechargeable batteries for future missions to Mars and the outer planets that are capable of operating over a wide range of temperatures, with high specific energy and energy densities. Due to the attractive performance characteristics, Li-ion batteries have been identified as the battery chemistry of choice for a number of future applications. For example, JPL is planning to launch another unmanned rover mission to the planet Mars. This mission, referred to as the Mars Science Laboratory (MSL), will involve the use of a rover that is much larger than the previously developed Spirit and Opportunity Rovers for the 2003 Mars Exploration Rover (MER) mission, that are currently still in operation on the surface of the planet after more than five years. Part of the reason that the MER rovers have operated so successfully, far exceeding the required mission duration of 90 sols, is that they possess robust Li-ion batteries, manufactured by Yardney Technical Products, which have demonstrated excellent life characteristics. Given the excellent performance characteristics displayed, similar Li-ion batteries have been projected to successfully meet the mission requirements of the up-coming MSL mission. In addition to future missions to Mars, Li-ion technology is attractive for a number of other future NASA applications which require high specific energy, rechargeable batteries. To ascertain the viability of using Li-ion batteries for these applications, a number of performance validation tests have been performed on both Yardney cells and batteries of various sizes. These tests include mission simulation tests, charge and discharge rate characterization testing, cycle life testing under various conditions, and storage testing.

Smart, M. C.↗

Thermal Performance Testing Of Cryogenic Piping Systems

Thermal performance measurement of piping systems under actual field conditions is important for space launch development and commercial industry. Knowledge of the true insulating effectiveness is needed in system design, development, and research activities. A new 18-meter-long test apparatus for cryogenic pipelines has been developed. Three different pipelines, rigid or flexible, can be tested simultaneously. Critical factors in heat leak measurements include eliminating heat transfer at end connections and obtaining proper liquid saturation condition. Effects due to variations in the external ambient conditions like wind, humidity, and solar radiation must be minimized. The static method of liquid nitrogen evaporation has been demonstrated, but the apparatus can be adapted for dynamic testing with cryogens, chilled water, or other working fluids. This technology is suited for the development of an industry standard test apparatus and method. Examples of the heat transfer data from testing commercially available pipelines are given. Prototype pipelines are currently being tested and evaluated at the Cryogenics Test Laboratory of NASA Kennedy Space Center.

Fesmire, J. E.↗

Results of Tests Performed on the Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel

The test results briefly described in this report were obtained on the three-dimensional 1:48 scale tunnel modeled on the design proposed by Messrs. D.S.M.A. Corporation. More particularly, while the test chamber dimensions were indeed scaled down in the ration of 1:48, including the contraction and the collector as well, the duct system itself leading to and from the chamber was adapted to suit laboratory conditions and space limitations. Earlier tests with the two-dimensional model showed that blowing mode was preferred as against the suction mode, hence all tests were performed with blowing only. At the exit of the contraction the maximum airspeed attained with the 1 HP blower unit was about 200 ft/sec. This airspeed may be increased in future if desired. The test results show that pressure recovery in the diffuser was about 34 percent due to the large blockage at its entrance. Velocity traverses taken across the diffuser entrance explain the reason for this blockage. Recirculation, studied with both, hot-wire anemometry and flow-visualization techniques, was largely affected by the design of the test chamber itself and the amount of vent-air admitted to the chamber. Vent-air helped to decrease the level of turbulence.

Barna, P. S.↗

Summary report on the mechanical testing performed at INL for creep rupture, fatigue, creep-fatigue, and aging of A709 base material

The report provides the status of the creep, fatigue, and creep-fatigue testing to conducted at Idaho National Laboratory to generate a data package to support Alloy 709 qualification in American Society of Mechanical Engineers, Boiler and Pressure Vessel Code, Section III, Division 5. These tests were performed on three commercial heats of plate material. The first procured heat was manufactured by G.O. Carlson with heat number 58776. Second and third heats were fabricated by ATI Specialty Rolled Products, with heat numbers 529900 and 530843, respectively. A series of creep and cyclic specimens were fabricated from these three heats, and tests were performed. This report presents a master list of all completed and ongoing creep, fatigue, and creep fatigue tests. Cyclic properties of three commercial heats are compared. Thermal aging of three commercial heats for 3000 hours were completed in FY 2025. The thermal aging campaign to age plate material from three commercial heats up to 100,000 hours is ongoing.

36 - MATERIALS SCIENCE↗

Using Concurrent Cardiovascular Information to Augment Survival Time Data for Evaluating Orthostatic Tilt Test Performance

Head-up tilt (HUT) tests often are used in research to measure orthostatic intolerance (OI) (inability to appropriately control blood pressure while upright) in clinical populations and otherwise healthy individuals after interventions. Post-space flight orthostatic intolerance is a well-known phenomenon, and countermeasures to its development has been an active area of research at NASA. In the NASA HUT protocol, subjects lie horizontally on an automatic tilt table for baseline measurements before being raised to 80deg head-up tilt for a defined period of time or until signs or symptoms of presyncope ensues (light-headedness, nausea, dizziness, sweating, weakness or fainting). Multiple measures are collected to evaluate the cardiovascular system's ability to respond appropriately to the orthostatic challenge. However if the intended duration of the HUT is short, the ability to detect changes in OI due to an intervention or its prevention by a countermeasure may be limited by a small number of failures to permit comparisons based on survival time alone. Thus, the time-trajectory of the cardiovascular data becomes an important additional source of information. In particular, we will show how various measures of trajectory variability can effectively augment survival analysis for the assessment of OI in a joint model when high censoring rates are present.

Feiveson, Alan H.↗

Liquid Oxygen Propellant Densification Production and Performance Test Results With a Large-Scale Flight-Weight Propellant Tank for the X33 RLV

This paper describes in-detail a test program that was initiated at the Glenn Research Center (GRC) involving the cryogenic densification of liquid oxygen (LO2). A large scale LO2 propellant densification system rated for 200 gpm and sized for the X-33 LO2 propellant tank, was designed, fabricated and tested at the GRC. Multiple objectives of the test program included validation of LO2 production unit hardware and characterization of densifier performance at design and transient conditions. First, performance data is presented for an initial series of LO2 densifier screening and check-out tests using densified liquid nitrogen. The second series of tests show performance data collected during LO2 densifier test operations with liquid oxygen as the densified product fluid. An overview of LO2 X-33 tanking operations and load tests with the 20,000 gallon Structural Test Article (STA) are described. Tank loading testing and the thermal stratification that occurs inside of a flight-weight launch vehicle propellant tank were investigated. These operations involved a closed-loop recirculation process of LO2 flow through the densifier and then back into the STA. Finally, in excess of 200,000 gallons of densified LO2 at 120 oR was produced with the propellant densification unit during the demonstration program, an achievement that s never been done before in the realm of large-scale cryogenic tests.

Tomsik, Thomas M.↗

National Unmanned Aerial System Standardized Performance Testing and Rating (NUSTAR)

The overall objective of the NUSTAR Capability is to offer standardized tests and scenario conditions to assess performance of the UAS. The following are goals of the NU-STAR: 1. Create a prototype standardized tests and scenarios that vehicles can be tested against. 2. Identify key performance parameters of all UAS and their standardized measurement strategy. 3. Develop standardized performance reporting method (e.g., consumer report style) to assist prospective buyers. 4. Identify key performance metrics that could be used by judged towards overall safety of the UAS and operations. 5. If vehicle certification standard is made by a regulatory agency, the performance of individual UAS could be compared against the minimum requirement (e.g., sense and avoid detection time, stopping distance, kinetic energy, etc.).

Testing↗

Performance Testing of Thermal Interface Filler Materials in a Bolted Aluminum Interface Under Thermal/Vacuum Conditions

A thermal interface material is one of the many tools often used as part of the thermal control scheme for space-based applications. Historically, at Marshall Space Flight Center, CHO-THERM 1671 has primarily been used for applications where an interface material was deemed necessary. However, numerous alternatives have come on the market in recent years. It was decided that a number of these materials should be tested against each other to see if there were better performing alternatives. The tests were done strictly to compare the thermal performance of the materials relative to each other under repeatable conditions and do not take into consideration other design issues, such as off-gassing, electrical conduction, isolation, etc. The purpose of this Technical Memorandum is to detail the materials tested, test apparatus, procedures, and results of these tests. The results show that there are a number of better performing alternatives now available.

Glasgow, S. D.↗

Performance Testing of Thermal Interface Filler Materials in a Bolted Aluminum Interface Under Thermal/Vacuum Conditions

A thermal interface material is one of the many tools that are often used as part of the thermal control scheme for space-based applications. These materials are placed between, for example, an avionics box and a cold plate, in order to improve the conduction heat transfer so that proper temperatures can be maintained. Historically at Marshall Space Flight Center, CHO-THERM@ 1671 has primarily been used for applications where an interface material was deemed necessary. However, there have been numerous alternatives come on the market in recent years. It was decided that a number of these materials should be tested against each other to see if there were better performing alternatives. The tests were done strictly to compare the thermal performance of the materials relative to each other under repeatable conditions and they do not take into consideration other design issues such as off-gassing, electrical conduction or isolation, etc. This paper details the materials tested, test apparatus, procedures, and results of these tests.

Glasgow, Shaun↗

Cryogenic Thermal Performance Testing of Bulk-Fill and Aerogel Insulation Materials

The research testing and demonstration of new bulk-fill materials for cryogenic thermal insulation systems was performed by the Cryogenics Test Laboratory at NASA Kennedy Space Center. Thermal conductivity testing under actual-use cryogenic conditions is a key to understanding the total system performance encompassing engineering, economics, and materials factors. A number of bulk fill insulation materials, including aerogel beads, glass bubbles, and perlite powder, were tested using a new cylindrical cryostat. Boundary temperatures for the liquid nitrogen boil-off method were 293 K and 78 K. Tests were performed as a function of cold vacuum pressure from high vacuum to no vacuum conditions. Results are compared with other complementary test methods in the range of 300 K to 20 K. Various testing techniques are shown to be required to obtain a complete understanding of the operating performance of a material and to provide data for answers to design engineering questions.

Scholtens, B. E.↗

An Occupational Performance Test Validation Program for Fire Fighters at the Kennedy Space Center

We evaluated performance of a modified Combat Task Test (CTT) and of standard fitness tests in 20 male subjects to assess the prediction of occupational performance standards for Kennedy Space Center fire fighters. The CTT consisted of stair-climbing, a chopping simulation, and a victim rescue simulation. Average CTT performance time was 3.61 +/- 0.25 min (SEM) and all CTT tasks required 93% to 97% maximal heart rate. By using scores from the standard fitness tests, a multiple linear regression model was fitted to each parameter: the stairclimb (r(exp 2) = .905, P less than .05), the chopping performance time (r(exp 2) = .582, P less than .05), the victim rescue time (r(exp 2) = .218, P = not significant), and the total performance time (r(exp 2) = .769, P less than .05). Treadmill time was the predominant variable, being the major predictor in two of four models. These results indicated that standardized fitness tests can predict performance on some CTT tasks and that test predictors were amenable to exercise training.

Schonfeld, Brian R.↗

Performance test results of ETS-6 Ni-Cd cells

The topics covered are presented in viewgraph form and include the following: development schedule; main specification; cell design; production flow; acceptance test (1); acceptance test (2); cell weight; 20 C performance; capacity; overcharge pressure; end of charge voltage; -5 C performance; ETS-VI simulation cycle test; and battery storage.

Nakatani, Kensuke↗