Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV scenario generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

160 records · Page 9

Mitigating Voltage Instability in the Saudi Grid for a Decarbonized, Fully Solar Power System

Lately, solar photovoltaic (PV) has received significant interest due to its economic and environmental benefits. As the integration of renewable energy sources (RES) increases into existing power grids, challenges such as the decrease in short circuit ratio (SCR) are introduced. Here, this paper investigates a case study of the Saudi power grid, examining the voltage stability as the grid transitions from traditional power generation to 100% penetration of solar PV gradually. Moreover, the paper explores the relationship between the increase in solar penetration and the potential effects on the short circuit MVA (SCMVA), which could significantly impact the overall SCR of the system. To meet the North American Electric Reliability Corporation (NERC) recommendation of maintaining SCR at a particular level, synchronous condensers (SC)s were integrated into the grid. The effectiveness of utilizing SCs to maintain the system voltage at optimal levels in a fully solar grid is also considered. In addition, this paper covers the weak grid analysis via utilizing the Newton-Raphson load flow method, along with PV and QV curve analyses. The purpose behind that is to determine weak bus locations in need of voltage improvements, and to meet the amount of reactive power to be injected. Finally, the amount of power being delivered by SCs will be added progressively in three scenarios to show the enhancements on SCR more precisely.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating capacity credit sensitivity to reliability metrics and computational methodologies

Assigning capacity value to renewable energy sources (RES) is a challenge faced in planning their integration with the grid. The difficulties stem from the natural characteristics of variability and intermittency of wind and solar sources. The capacity credit (CC) analysis evaluates the system’s actual power output compared with a constant capacity generator, i.e., conventional generator and determines an effective capacity to use for planning and operation. Herein this paper presents different factors that could affect the CC of a system. Two methods are proposed to determine the CC, namely equivalent firm capacity (EFC) and effective load carrying capability (ELCC). Since these methods are based on satisfying reliability criteria, daily loss of load expectation (LOLE), hourly loss of load (LOLH), and expected energy not served (EENS) have been employed as indices. To obtain the CC value, both methods apply two techniques: traditional and optimization. Genetic algorithm (GA) is the optimization approach used in this paper. Then, this work compares the two techniques and shows the superior performance of the optimization approach. Two hybrid systems, stand-alone (SA) and grid-connected (GC) modes, are proposed and used as case studies. The hybrid systems consist of photovoltaic (PV), wind turbine (WT), and battery energy storage system (BESS). In this work, three different scenarios are used to compare capacity credit: system as a whole, only wind, and no batteries. Finally, sensitivity analysis is carried out to examine the impact of varying the wind speed, solar irradiation, and load. It is demonstrated that the choice of reliability index plays an important role in determining the capacity credit and it is shown that EENS is a more comprehensive and consistent index of reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The economic value of photovoltaic performance loss mitigation in electricity spot markets

Photovoltaic (PV) performance is affected by reversible and irreversible losses. These can typically be mitigated through responsive and proactive operations and maintenance (O&M) activities. However, to generate profit, the cost of O&M must be lower than the value of the recovered electricity. This value depends both on the amount of recovered energy and on the electricity prices, which can vary significantly over time in spot markets. The present work investigates the impact of the electricity price variability on the PV profitability and on the related O&M activities in Italy, Portugal, and Spain. Here, it is found that the PV revenues varied by 1.6 × to 1.8 × within the investigated countries in the last 5 years. Moreover, forecasts predict higher average prices in the current decade compared to the previous one. These will increase the future PV revenues by up to 60% by 2030 compared to their 2015–2020 mean values. These higher revenues will make more funds available for better maintenance and for higher quality components, potentially leading to even higher energy yield and profits. Linearly growing or constant price assumptions cannot fully reproduce these expected price trends. Furthermore, significant price fluctuations can lead to unexpected scenarios and alter the predictions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Average and Marginal Capacity Credit Values of Renewable Energy and Battery Storage in the United States Power System

As deployment of renewable resources and storage continue to significantly grow in the coming decades, these technologies will play increasingly important roles in maintaining power systems' resource adequacy. Few analyses so far offer comprehensive comparisons of forward-looking average and marginal capacity credits of variable renewable energy and storage in the U.S. interconnections across a wide range of possible futures. To fill this research gap, we quantify the average and marginal capacity credits of solar PV, onshore and offshore wind, and batteries between 2026 and 2050 across the U.S power systems to examine the temporal trends, spatial patterns, and trade-offs between these two capacity accreditation approaches. Across technologies, capacity credits of solar PV most clearly follow downward trends over time, reflecting the significant rise in solar PV generation share as the grid decarbonizes. While battery storages' generation shares also rise significantly over time, their capacity credits always remain stably high due to their capabilities to be dispatched strategically during critical periods to maintain reliability. On the other hand, capacity credits of wind technologies in general follow slight upward trends as their generation shares level off. There are strong spatial variabilities of both average and marginal capacity credits across technologies, but capacity credits of solar PV displaying the most obvious spatial patterns with high capacity credits concentrating in wind-rich, solar-poor regions in SPP, PJM, and MISO, suggesting potential reliability benefits of interconnection-wide planning for renewable energy deployments. Additionally, except for offshore wind, average capacity credits of all other renewable technologies tend to be higher than their marginal capacity credits, indicating that existing renewable resources tend to be accredited higher than new resources at almost any time.

25 ENERGY STORAGE↗

Safe Deep Reinforcement Learning for Active Distribution System Model Predictive Control with EVs and DERs

The temporal and spatial mismatch between PV generation and electric vehicle (EV) charging and discharging may cause voltage violations in active distribution networks. Despite the widespread use of deep reinforcement learning (DRL) in power system optimization and control, it lacks guarantees on constraint satisfaction during both training and deployment. This paper proposes a Lagrangian-based safe DRL approach for model predictive control (MPC) of active distribution systems with large-scale integration of PVs, EVs, and energy storage systems (ESSs). A Transformer-LSTM time-series model is proposed to forecast EV charging demand, which is then formulated as a constraint to ensure charging requirements are met. Using this prediction, a Lagrangian-based safe soft actor-critic (SAC) framework is developed for real-time control in a three-phase unbalanced distribution system, enforcing voltage safety constraints while optimizing the cumulative net reward. By integrating the forecasting model with multi-period constraints, the proposed framework jointly coordinates PV systems, EV charging and discharging, and ESS scheduling within the MPC horizon. Numerical experiments on a modified IEEE 123-bus system with real-world data show that, under a high PV penetration scenario, the proposed method increases the net reward by 30.74% and reduces average voltage violations from 0.0011 p.u. to 0.0002 p.u. compared with standard SAC. Compared with the optimal power flow (OPF) approach, it achieves similar voltage security while yielding lower line losses. It also maintains real-time control capability, reducing operation latency to 53.21 ms per 15-minute control interval. The proposed method remains effective under varying PV/EV penetrations and load conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The National Climate Database (NCDB): An Unbiased 100-Year Dataset for PV Modeling

In this study, we develop a statistical technique to downscale the future projection of solar irradiance for photovoltaics (PV) energy-related applications. A set of Regional Climate Model (RCM)-based projections obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) are used as inputs to statistical methods to generate high-resolution global horizontal irradiance (GHI) over the contiguous United States (CONUS). The main steps of the statistical downscaling method include (1) regridding RCM output (0.22 degree and daily resolutions) to handle the modeled-observed data sets on a common grid, (2) correcting bias of RCM GHI using satellite-derived observation, and (3) implementing temporal and spatial downscaling to generate GHI at 8-km and hourly resolution. Basically, complex physical processes and interactions between solar radiation and various atmospheric constituents lead solar irradiance to be highly variable and uncertain. Underrepresentation of clouds from the RCM parameterizations is the main source of error and uncertainty in modeling solar irradiance. Thus, we adapt and use the high-quality satellite-derived data from the National Solar Radiation Database (NSRDB) to analyze the bias and error of RCM GHI as well as estimate the statistical parameters for spatial and temporal downscaling. This presentation will summarize the comprehensive analysis conducted to produce and assess the results under two climate scenarios (RCP4.5 and RCP8.5). We will also present a detailed validation demonstrating the strengths of the downscaling method, a summary of the 100-year dataset from 2001-2100, and future extension of this research.

bias correction↗

Integrating Concentrating Solar Power Technologies into the Hybrid Optimization and Performance Platform (HOPP)

As the world increases renewable energy deployment, there is an increasing interest in hybridizing various generation and storage technologies to maximize net benefit to the developer and/or off-taker. A particularly interesting combination of renewable technologies is concentrating solar power (CSP) with thermal energy storage (TES), photovoltaics (PV), and electrochemical battery energy storage (BESS). Due to the system complexity of CSP technology, it is difficult to evaluate the technological and financial performance of a CSP-PV hybrid system without detailed modeling of annual operations. To address this challenge, we have developed a modeling framework for evaluating the performance and financial viability of CSP systems hybridized with PV and battery technologies. This modeling effort incorporates CSP tower and trough systems into an existing modeling tool recently developed by NREL referred to as the Hybrid Optimization and Performance Platform (HOPP). This report outlines the modeling methodology as well as preliminary results from example case studies conducted using the model. The methodology describes: (i) the integration of CSP tower and troughs into HOPP using python interfaces to access System Advisor Model (SAM) underlining technology models, (ii) the mathematical formulation of the mixed integer linear program dispatch optimization model which optimizes operations of storage asset to either maximize system revenue or minimize operating cost while load following, (iii) the design analysis methods implemented within HOPP, and (iv) simulation clustering for the purposes of reducing computational expense. We exercise the model using a case study of a future scenario where we assume (i) CSP and PV technologies achieve the 2030 cost targets provided by the Solar Energy Technologies Office (SETO), (ii) battery costs reduce to the 2030 mid cost projection presented by NREL. Lastly, (iii) electricity prices for southern California in 2030 are provided by NREL's Cambium database, and (iv) a capacity payment of $150/kW-yr based on the system capacity factor during the to 100 net-load hours.

14 SOLAR ENERGY↗

Next-Generation Reverse Logistics Networks of Photovoltaic Recycling: Perspectives and Challenges

With the growing adoption of solar energy as a key component of the global energy transition and its new industrial policy (the Inflation Reduction Act and others), the United States is witnessing a significant increase in solar investments. This surge in installations and domestic and reshored manufacturing of solar photovoltaic (PV) panels brings with it a pressing issue: the proper management of end-of-life (EoL) PV panels. As these panels are decommissioned, either due to reaching the end of their lifespans or due to breakage across the various stages of the forward supply chain, it becomes crucial to establish efficient reverse supply chain logistics systems to address the challenges associated with their disposal, while also unlocking the value of the inherent materials that are of critical value for other forward supply chains. This perspective article examines the challenges regarding EoL PV panels and relevant reverse supply chain and logistics networks, and proposes future research directions based on the gaps observed among academic research, industry, and policy-making challenges. We identify the main bottlenecks and hurdles including, among others, the lack of supportive regulations and absence of structured, optimized recycling infrastructure. To this end, it is proposed that the key to achieving a sustainable reverse supply chain network for solar PV panels lies in relentless end-to-end supply chain cost optimization efforts supported by enabling policies. Moreover, it is proposed that designing systematic decision-making modeling frameworks is vital for examining different possibilities and scenarios for state, region or nation-wide optimization of solar PV reverse supply chain networks. Indicative to this effect, we discuss the development of a Resource-Task-Network (RTN)-based model and demonstrate its application and benefits through a case study. We wrap up with conclusions and future research directions.

circular economy↗

Enabling Cybersecurity, Situational Awareness and Resilience in Distribution Grids with High Penetration of Photovoltaics (CARE-PV) (Final Report)

Since legacy distribution systems have very limited visibility beyond the substation, high penetration of PV at the grid edge presents some unique operational challenges. One approach to address these challenges is to use information from advanced metering infrastructure (AMI) and µPMUs. However, exploiting this information is impacted by a number of factors, including multi-timescale measurements, volume of data generated, communication network impairments (e.g., information loss and latency) and susceptibility to cyber-attacks. Therefore, one of the critical tasks involved in the management of a distribution grid is to develop complete situational awareness by integrating cyber-security mechanisms with state estimation strategies and leveraging this situational awareness to assure energy services at strategic locations while exploiting AMI/PV inverter/ µPMU data. This CARE-PV project addresses the fundamental challenges in situational awareness and resilience to cyber and physical vectors by exploiting the synergy between innovative modeling, estimation, data analytics, testing and validation using smart PV inverters designed at K-State and facilities at NREL. Specifically, the project involved the development, testing and validation of the following novel enabling technologies: (Thrust 1) Resilience to cyber vectors that impact data integrity was addressed via a two-level defense strategy that combines cyber intrusion detection using self-learning, cooperative smart PV inverters, and a novel moving target defense framework to combat data integrity attacks. (Thrust 2) Resilience to cyber-physical vectors that impact situational awareness by limiting data availability was addressed via novel centralized and decentralized, sparsity-based static and dynamic state estimation approaches that enhance observability even when the underlying system is unobservable. (Thrust 3) Leveraging a unique probabilistic sensitivity analysis approach accompanied by one-of-a-kind dominant influencer set computation, the vulnerability of critical infrastructure at strategic locations was evaluated so that proactive PV-based control strategies can be used to support operations under normal/outage scenarios. These CARE-PV project innovations were demonstrated on both small-scale IEEE and larger utility-scale testbeds (Thrust 4). Feedback from Industry Advisory Board members was used to formulate a commercialization pathway for a subset of CARE-PV technologies. These CARE-PV technologies will ultimately lead to reliable and secure, large-scale integration of renewable energy and mitigate the risk of energy disruption resulting from cyber incidents and other emerging threats within the energy environment.

14 SOLAR ENERGY↗

Feasibility Analyses for the Microgrid of the Mountain in the Cordillera Central Region of Puerto Rico

Distributed energy resource (DER) development can benefit communities through improvement of access to reliable electricity and a resilient energy system. Many place-specific considerations must be accounted for when designing electrical systems with co-located generation and loads. This paper presents an overview of four studies focusing on different aspects for regional DER development in the Cordillera Central region of Puerto Rico, including a grid and load stability study with the introduction of solar energy generation, microgrid design based on the solar resource in the area, resilience considerations during power outage scenarios, and qualitative risk aspects for components in the microgrid. Additionally, a conceptual substation microgrid analysis is conducted using the Microgrid Design Toolkit (MDT) to evaluate trade-offs between cost and energy availability, providing insights into optimal design strategies. A microgrid resilience assessment is performed using the Resilient Nodal Cluster Analysis Tool (ReNCAT) to identify critical loads and evaluates their accessibility during outages, emphasizing the importance of community needs. Finally, a qualitative risk assessment utilizing Hazard and Operability Analysis (HAZOP) methods highlights potential hazards and mitigations for microgrid components, ensuring robust system design and operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Hydropower and PSH Capacity Expansion Modeling (Final Report on HydroWIRES D1 Improvements to Capacity Expansion Modeling)

Hydropower and pumped-storage hydropower (PSH) have played a key role in providing flexible, low-carbon electricity to the U.S. electricity system for over a century. As variable generation (VG) deployment increases the demand for flexible, dispatchable generation, it is important to use all available methods for understanding how hydropower and PSH interfaces with VG in a future low-carbon grid. Capacity expansion models (CEMs) of electricity systems are often used to study future electricity scenarios, but these tools often have difficulty representing site- and technology-details of hydropower and PSH due to limited spatial, temporal, or process resolution. This report demonstrates a set of model advancements to improve hydropower and PSH representations in CEMs and other models that consider hydropower and PSH's role in electricity systems. Model advancements include new data integration to define closed-loop PSH resource availability and cost, along with site-level parameterizations of existing PSH capacity and energy storage specifications. Shifting energy across seasons for both hydropower and PSH is explored to demonstrate the potential value of long-duration storage. New representations of hydropower upgrades offer opportunities to increase dispatchability, add pumps, or independently add capacity or energy depending on what is most valuable. New model structures and data are demonstrated individually and in combination to observe their impact on model results and provide initial insights into what is most important for analysts, electricity system planners, and hydropower decision-makers to consider when assessing future roles of hydropower. Improving flexibility of existing hydropower assets has the potential to reduce CO 2 emissions through complementing VG technologies and/or improve electricity system economics by reducing the need to deploy higher-cost systems. Large-scale energy storage is also shown to provide opportunities for balancing seasonal differences in VG, particularly solar photovoltaics (PV). Initial analysis with a new closed-loop PSH resource and cost dataset also demonstrate the potential for new PSH deployment to offer new grid flexibility opportunities. Future analysis and modeling of hydropower's role in the U.S. and other electricity systems could include methodological improvements based on those discussed here along with sensitivity analysis to better represent current and future potential hydropower and PSH flexibility. Improvements to geospatial and site-level data can further improve the understanding of how hydropower and PSH can be upgraded and operated in response to future electricity system needs. This work lays the groundwork to use advanced planning models to explore the range of roles hydropower and PSH can play in the grid of the future.

13 HYDRO ENERGY↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Getting brighter: Impacts of improved day-ahead solar forecasts in high-solar, high-storage electricity systems

This paper analyzes the impacts of improved day-ahead solar forecasts on costs and dispatch in the solar-rich Southeast U.S. It uses an optimized high-solar, high-storage resource portfolio in which solar generation capacity accounts for 45 % of total installed capacity (34 %–36 % of generation) and energy storage capacity (43 GW) is equivalent to 33 % of peak demand. In a base scenario, improved day-ahead solar forecasts reduce production costs by $\$87$ million per year ($\$0.13$ per MWh load, $2023$$). This level of savings is within the range or lower than earlier studies of solar forecast improvements at lower levels of solar generation (<25 % of total generation). In this study, solar expansion was accompanied by two important sources of flexibility for managing solar forecast error: energy storage and day-ahead solar curtailment. Furthermore, the analysis finds that regional coordination complements day-ahead solar forecast improvements while natural gas commitment flexibility is a substitute for forecast improvements, as the improved solar forecast leads to sub-optimal commitment of thermal units. Day-ahead solar forecast improvements reduce reserves required to manage forecast error by 30 %. Fewer reserves to manage large, infrequent solar forecast errors could be an important benefit of improved solar forecasts.

14 SOLAR ENERGY↗

Sizing and Location Selection of Medium‐Voltage Back‐to‐Back Converters for DER‐Dominated Distribution Systems

Medium‐voltage back‐to‐back (MVB2B) converters can connect two distribution systems and quantifiably transfer power between them. This function can enable the MVB2B converter to exchange distributed energy resource (DER)‐generated power between two systems and bring significant value to enhancing distribution system DER adoption. Our previous work analysed and demonstrated the value MVB2B converter can bring to DER integration. As continuous work, this paper presents a methodology that helps address the MVB2B converter sizing and location selection problem in distribution systems with high DER penetrations. The proposed methodology aims to address three critical problems for MVB2B converter implementation in the real world: (1) which distribution systems are better to be connected, (2) what converter size is appropriate for connecting the distribution systems, and (3) where the optimal connection points are in the systems for connecting the MVB2B converter. The proposed methodology has been demonstrated by case studies that include various scenarios involving distribution systems with different dominated load types and high photovoltaic penetrations. The results demonstrate that selecting the optimal converter size based on net revenue and time of return considerations leads to a balance between maximizing energy savings and minimizing financial payback periods. Furthermore, feeder pair selection based on load profile standard deviation effectively identifies systems that derive the greatest value from MVB2B integration. Finally, an optimized connection point selection approach using a voltage load sensitivity matrix ensures minimal system impact while facilitating efficient power exchange. These findings provide practical insights for the real‐world deployment of MVB2B converters to enhance DER hosting capacity and improve grid resilience.

14 SOLAR ENERGY↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar photovoltaic (PV), and natural-gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in U.S. power markets. This is especially true for geothermal resources with low-to-medium temperatures, which results in relatively low-thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural-gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural-gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural-gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods. The hybrid cycles are compared to equivalently sized, co-located, independent geothermal, concentrating solar, and/or natural-gas power plants. The hybrid cycle tends to produce slightly more power than the standalone plants combined. However, the hybrid plant Levelized Cost of Energy (LCOE) is slightly higher than the LCOE of the combined standalone power plants for each of the case study locations investigated. Using the steam-topping cycle, organic Rankine cycle (ORC)-bottoming cycle hybrid plant design to combine a solar thermal resource and low- temperature geothermal resource (<120 degrees C) leads to a hybrid plant with a lower LCOE than a standalone geothermal-only system. Thus, hybrid plants may enable the economic development of geothermal resources in locations with low geothermal resource temperatures. However, in areas with higher geothermal resource temperatures (>120 degrees C), the geothermal-only plant has a lower LCOE than the hybrid cycle and thus could be developed without the need for solar heat addition. iv A geothermal-natural-gas reciprocating engine hybrid plant was evaluated for an Elk Hills, California case study location. The Elk Hills case study analysis indicates that when the natural-gas engine operates for more than 12 hours per day the hybrid plant can produce power at an LCOE lower than a standalone geothermal plant, and comparable to that of the standalone natural-gas reciprocating engine, while also reducing the carbon intensity of the power generated relative to the standalone natural-gas engine. This may represent a scenario in which the hybrid plant provides an opportunity for the deployment of a low-temperature geothermal resource that otherwise may have an LCOE too high to develop and operate as a standalone resource, while also reducing the carbon intensity of natural-gas generation sources. A "triple-hybrid" plant that combines natural gas, solar thermal, thermal energy storage, and geothermal was also investigated. A natural-gas combustion turbine (NGCT) is added to the geothermal-solar hybrid such that the hot exhaust gas from the gas turbine provides an alternative source of heat to the steam turbine of the hybrid cycle. Analysis results suggest that the triple-hybrid plant has a significantly higher energy generation and revenue than a standalone NGCT or the original geothermal-solar hybrid. The triple-hybrid design benefits most from using a smaller solar field so that the solar energy can be dispatched at the most valuable times available. The triple-hybrid plant also has a lower LCOE than the standalone NGCT. The triple-hybrid plant was evaluated making simple assumptions about the dispatch profile of the gas cycle, and more nuanced and realistic dispatching schedules should be analyzed in future work.

15 GEOTHERMAL ENERGY↗

Heliostats with Adjustable Shape for High Concentration throughout the Day

Our motivation is to develop more efficient heliostats that can provide commercially viable solar thermal power at temperatures > 800°C. Such high temperatures will enable high-temperature industrial processes, as well as electrical generation after sunset with high efficiency. The importance of this research is that such heliostats have the potential to substantially expand the global use of solar energy, by adding solar thermal power as a major component. Thermal solar currently accounts for only 1% of all solar power (with PV being the rest), with heliostat fields providing just 0.25%. Our goals have been 1) to demonstrate a technical improvement for heliostats that can enable fields of them to more efficiently power receivers and reactors, and 2) to show a path to low-cost mass production. Our solution uses new opto-mechanical technology to correct a fundamental deficiency of present heliostats that limits their concentration, namely that they have fixed shape. Most of today’s heliostat research does not address this, but is directed simply toward cost reduction in an effort to make heliostats commercially viable. We are motivated to explore also improving heliostat efficiency, which can be done by continually changing their shape to maximize the concentration of sunlight throughout the day. This is not a new concept, but it has never been implemented in a practical, cost-effective way that approaches the theoretical limit to concentration while also improving mechanical performance; this is our goal. Our major accomplishments have been: 1) We have realized the planned design, construction, and test of a prototype heliostat that achieves the required shape changes in an 8 m2 single-piece glass mirror. The mirror is attached to a steel support frame that is automatically mechanically twisted by the heliostat drives that orient the mirror to direct sunlight to the tower-mounted receiver. Closed-loop tracking is done using a new beamsplitter camera that exploits the target-oriented mount configuration. Field tests of the heliostat show that the light is reflected through the day to always form a disc image of the sun, as needed to obtain the highest concentration. 2) We have developed the design for a field of 431 heliostats to deliver annual average of 1 MW of thermal power at 3,000 sun concentration, matched to a high-temperature ≥ 1000°C chemical reactor. 3) We have also developed, beyond the original stated goals of the project, a new concept for closed-loop tracking and shape-sensing for all the heliostats in the above field, using just 6 cameras around the concentrated reactor focus. Our research adds to the understanding of solar thermal energy by its demonstration of the technical effectiveness of a higher performing heliostat, and by its concept for a new powerful method for real-time tracking and shape sensing in the field, as described above. We have studied the economic feasibility of fields of our twisting heliostats to provide high- temperature heat at a price competitive with that of burning gas, to satisfy the DOE’s studied zero-emissions scenario, where the gas price has to include the cost of carbon capture. The project has the potential to greatly benefit the public if it helps limit global warming by 1) reducing carbon emission from industrial heating, which is currently a major contributor to the 40-billion-ton annual increase in atmospheric CO 2 . 2) Ultimately, the technology could prove to be the least expensive method to power direct air capture of CO 2 on the very large scale needed to remove the 1 trillion-ton excess of CO 2 already in the atmosphere.

14 SOLAR ENERGY↗