Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Preliminary investigation of labyrinth packing pressure drops at onset of swirl-induced rotor instability

Backward and forward subsynchronous instability was observed in a flexible model test rotor under the influence of swirl flow in a straight-through labyrinth packing. The packing pressure drop at the onset of instability was then measured for a range of operating speeds, clearances and inlet swirl conditions. The trend in these measurements for forward swirl and forward instability is generally consistent with the short packing rotor force formulations of Benchert and Wachter. Diverging clearances were also destabilizing and had a forward orbit with forward swirl and a backward orbit with reverse swirl. A larger, stiff rotor model system is now being assembled which will permit testing steam turbine-type straight-through and hi-lo labyrinth packings. With calibrated and adjustable bearings in this new apparatus, direct measure of the net destabilizing force generated by the packings can be made.

Miller, E. H.↗

Low-Pressure-Drop Shutoff Valve

Flapper valve remains open under normal flow conditions but closes upon sudden increases to high rate of flow and remains closed until reset. Valve is fluid/mechanical analog of electrical fuse or circuit breaker. Low-pressure-drop shutoff valve contains flapper machined from cylindrical surface. During normal flow conditions, flapper presents small cross section to flow. (Useful in stopping loss of fluid through leaks in cooling systems.)

Thornborrow, John↗

Pressure drop and heat transfer characteristics of nitrate salt and supercritical CO 2 in a diffusion-bonded heat exchanger

A lab-scale 316/L stainless steel diffusion-bonded heat exchanger was examined within a coupled high-temperature test facility consisting of an atmospheric-pressure nitrate salt loop and a supercritical carbon dioxide (sCO 2 ) loop operating between 10 and 16 MPa. Pressure loss measurements collected for flow rates up to 0.55 kg/s of Solar Salt and up to 0.6 kg/s of carbon dioxide were used to generate friction factor correlations for the respective circular and semicircular zig-zag flow passages. Heat transfer measurements were also performed over a wide range of conditions to produce Nusselt correlations for the CO 2 and nitrate salt geometries. The Nusselt number is deduced from a heat transfer resistance network and overall conductance measurements collected across the operating envelope of the coupled sCO 2 – nitrate salt test facility. The CO 2 side correlation showed excellent agreement with existing correlations in the literature. Further, the salt side, having nearly circular channels with a different zig-zag angle and hydraulic diameter, yielded a new correlation applicable to the laminar flow regime. To examine the similitude of the friction correlations, pressure drop testing with water was performed on both sides of the component as well. Finally, results from non-destructive examination are discussed to provide insights regarding inspection methods and draining performance of high-temperature liquids in compact heat exchangers.

36 MATERIALS SCIENCE↗

Measurement of heat transfer and pressure drop in rectangular channels with turbulence promoters

Periodic rib turbulators were used in advanced turbine cooling designs to enhance the internal heat transfer. The objective of the present project was to investigate the combined effects of the rib angle of attack and the channel aspect ratio on the local heat transfer and pressure drop in rectangular channels with two opposite ribbed walls for Reynolds number varied from 10,000 to 60,000. The channel aspect ratio (W/H) was varied from 1 to 2 to 4. The rib angle of attack (alpha) was varied from 90 to 60 to 45 to 30 degree. The highly detailed heat transfer coefficient distribution on both the smooth side and the ribbed side walls from the channel sharp entrance to the downstream region were measured. The results showed that, in the square channel, the heat transfer for the slant ribs (alpha = 30 -45 deg) was about 30% higher that of the transverse ribs (alpha = 90 deg) for a constant pumping power. However, in the rectangular channels (W/H = 2 and 4, ribs on W side), the heat transfer at alpha = 30 -45 deg was only about 5% higher than 90 deg. The average heat transfer and friction correlations were developed to account for rib spacing, rib angle, and channel aspect ratio over the range of roughness Reynolds number.

Han, J. C.↗

Heat transfer and pressure drop in blade cooling channels with turbulence promoters

Repeated rib roughness elements have been used in advanced turbine cooling designs to enhance the internal heat transfer. Often the ribs are perpendicular to the main flow direction so that they have an angle-of-attack of 90 deg. The objective of the project was to investigate the effect of rib angle-of-attack on the pressure drop and the average heat transfer coefficients in a square duct with two opposite rib-roughned walls for Reynolds number varied from 8000 to 80,000. The rib height-to-equivalent diameter ratio (e/D) was kept at a constant value of 0.063, the rib pitch-to-height ratio (P/e) was varied from 10 to 20, and the rib angle-of-attack (alpha) was varied from 90 deg to 60 deg to 45 deg to 30 deg respectively. Two types of entrance conditions were examined, namely, long duct and sudden contraction. The heat transfer coefficient distribution on the smooth side wall and the rough side wall at the entrance and the fully developed regions were measured. Thermal performance comparison indicated that the pumping power requirement for the rib with an oblique angle to the flow (alpha = 45 deg to 30 deg) was about 20 to 50 percent lower than the rib with a 90 deg angle to the flow for a given heat transfer duty.

Han, J. C.↗

Generalized Charts for Determination of Pressure Drop of a High-speed Compressible Fluid in Heat-exchanger Passages I : Air Heated in Smooth Passages of Constant Area with Constant Wall Temperature

In the present paper an analysis is made of the compressible-flow variations occurring in heat-exchanger passages. The results of the analysis describe the flow and heating characteristics for which specific flow passages can be treated as segments of generalized flow systems. The graphical representation of the flow variations in the generalized flow systems can then be utilized as working charts to determine directly the pressure changes occurring in any specific flow passage. On the basis of these results, working charts are constructed to handle the case of air heated at constant wall temperature under turbulent-flow conditions. A method is given of incorporating the effect on the heat-exchanger flow process of high temperature differential between passage wall and fluid as based on recent NACA experimental data. Good agreement is obtained between the experimental and the chart pressure-drop values for passage-wall average temperatures as high as 1752 degrees R (experimental limit) and for flow Mach numbers ranging from 0.32 to 1.00 (choke) at the passage exit.

Valerino, Michael F↗

Pressure Drop in Seven-Pin Wire-Wrapped Rod Bundle for the Sodium Cartridge Loop in Versatile Test Reactor

This work studies the hydrodynamics of the seven pin wire-wrapped rod bundle in the sodium cartridge loop for the Versatile Test Reactor (VTR) through scaled water experiments and computational fluid dynamics (CFD) simulations. Here, the scaling analysis is first performed to demonstrate the hydrodynamic similarity between water and sodium flows at the same Reynolds number Re. A separate-effects test facility is designed and constructed based on the scaling analysis. Detailed experimental data on the pressure drop covering a wide range of Re values (1165 to 27 689) are obtained, which are used to evaluate existing correlations for friction factor and to benchmark CFD simulations. The experimentally determined friction factors f Exp agree well with the Upgraded Cheng and Todreas Detailed Correlation and Pacio-Chen-Todreas Detailed Model within ±7% but are significantly underpredicted by Rehme's correlation by 25%. Various CFD near-wall treatment methods are tested using ANSYS Fluent and evaluated by experimental data. It is found that when the recommended wall y + values are met, most of the near-wall treatment methods can give accurate friction factor predictions. The resolved near-wall method (y + ~ 1) with the Shear Stress Transport k - ω turbulence model and the scalable wall functions (y + > 12) with the realizable k - ε turbulence model can predict f Exp within ±5% The standard wall functions (y + > 30) and nonequilibrium wall functions (y + > 30) with the realizable k - ε model can predict f Exp within ±10%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CFD Benchmark of Pressure Drop in a 61-Pin Wire-Wrapped Assembly with Blocked Channels Using NekRS

Thermal hydraulic behaviors of wire-wrapped rod bundles continue to be a subject of intense research. One of the leading next-generation designs, the sodium fast reactor, relies on a hexagonal assembly of wire-wrapped fuel pins. The issue of potential channel blockage has been raised as a safety concern due to the tightly packed arrangement of the fuel pins. This has led to several recent experimental and computational studies working to quantify the potential impact on the fluid flow and heat transfer behaviors of such blockages. The objective of the present study is to benchmark the high-fidelity NekRS CFD solver in predicting pressure drop for large blockages against available experimental data. A 61-pin wire-wrapped fuel assembly with two flow blockage configurations has been simulated and investigated at various low to moderate Reynolds numbers. The NekRS solver has been shown to yield exponentially decreasing spatial discretization errors with increasing polynomial order. All simulated results agreed well with measured data, which indicates that the overall methodology is adequate and consistent. The results of this benchmark study demonstrate the accuracy of NekRS for sodium fast reactor hydrodynamic simulations, increasing the confidence in its use for design, licensing, and analysis activities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Three Dimensional Instantaneous Spray Measurements of Additively Manufactured Candidate Injector Schemes at Varying Pressure Drops

Additively manufactured (AM) injectors have the potential to improve upon the combustion performance achieved using traditionally manufactured (TM) injectors. Traditionally manufactured injector combustion performance decreases greatly in off-design conditions. Additively manufactured injectors hold the potential to sustain high combustion performance over a broader range of operating conditions than currently seen in TM injectors. Additively manufactured injectors promise to offer higher resistances to instability and achieve better overall propellant mixing and atomization for all types of combustion devices. This study expands upon previous studies that used 2-D imaging techniques to characterize the injector spray pattern of candidate AM injector elements. In this study, 3-D instantaneous measurements of the injector spray pattern are taken, allowing for deeper insight into the liquid spray breakup, an inherently 3-D phenomena. Stereo imaging is used for three dimensional analysis, which utilizes two cameras at different angles to reconstruct a three dimensional reconstruction. With this information, AM injectors can be designed to improve propellant mixing and atomization and reduce breakup length. As part of this work, a high-pressure, cold flow experimental spray facility was modified to measure each injector’s spray characteristics in terms of 𝑅𝑒 𝐿 and 𝑊𝑒 𝑔 . This facility is operated to capture instantaneous stereo photographic images, mass flow rates, and injector element thrust for pressure drop across the injector face ranging from 100 to 200 psig at a stiffness ratio of 1.0.

Murphy Mitchell↗

Gas convection caused by electron pressure drop in the afterglow of a pulsed inductively coupled plasma discharge

Neutral depletion is an important phenomenon in high-density plasmas. We show that in pulsed discharges, the neutral depletion caused by the electron pressure P{sub e} plays an important role on radical transport. In the afterglow, P{sub e} drops rapidly by electron cooling. So, a neutral pressure gradient built up between the plasma bulk and the reactor walls, which forces the cold surrounding gas to move rapidly toward the reactor center. Measured drift velocity of Al atoms in the early afterglow of Cl{sub 2}/Ar discharge by time-resolved laser induced fluorescence is as high as 250 ms{sup -1}. This is accompanied by a rapid gas cooling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗