Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PMU”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Grid Operator Analytics and Assessment Tools for Inverter- Based Resources Dominated Grid (GOAAT-IBR) Project Update

This presentation provides an update on the OPTIMA GOAAT project, with emphasis on the cloud-native data platform developed in-house to ingest, manage, and operationalize high-resolution power system data. Since our last NASPI presentation, accessible via OSTI ID #2671437, the project team advanced the design and deployment of a scalable architecture capable of handling both synchronized and non-synchronized streams, including PMU, point-on-wave (POW), COMTRADE, and SCADA data. These materials review the project status, recent progress, and key lessons learned. The core of the presentation examines the architecture and engineering of our cloud-native ingestion and data management platform. We then explain how pipelines were designed to collect, normalize, time-align, store, and serve heterogeneous data at scale. We will discuss design choices such as data models, streaming versus batch ingestion, storage tiers, and interoperability with analytics applications. Practical experiences with cloud-native technologies were shared during the event, including benefits, limitations, and integration challenges in a utility environment, along with methods used to improve performance, reduce latency, and optimize resource usage. The presentation also showcases user interface designs and visualization tools that convert raw measurements and analytics results into intuitive, actionable insights for operators and engineers. During the presentation examples were provided demonstrating how visualization, event views, and summarized analytics enhance situational awareness and support operational decision-making. These use cases illustrate how a well-designed data infrastructure can bridge the gap between high-volume measurements and practical grid operations.

Aminifar, Farrokh↗

GPS Spoofing Mitigation and Timing Risk Analysis in Networked Phasor Measurement Units via Stochastic Reachability

To address phasor measurement unit (PMU) vulnerability to spoofing, we propose the use of a set-valued state estimation technique known as stochastic reachability (SR)-based distributed Kalman filter (DKF) that computes secure global positioning system (GPS) timing across a network of receivers. Utilizing SR, we estimate not only GPS time but also its stochastic reachable set, which is parameterized by probabilistic zonotope (p-Zonotope). While requiring known measurement error bounds in only non-spoofed conditions, we designed a two-tiered approach. We first performed measurement-level spoofing mitigation via deviation of a measurement innovation from its expected p-Zonotope. We then performed state-level timing risk analysis via a determination of the intersection probability of the estimated p-Zonotope with an unsafe set that violates IEEE C37.118.1a-2014 standards. Finally, we validated our SR-DKF algorithm by subjecting it to a simulated receiver network to coordinate signal-level spoofing. We demonstrate improved timing accuracy and successful spoofing mitigation via the use of our SR-DKF algorithm. We also validated the robustness of the estimated timing risk as the number of receivers were varied.

47 OTHER INSTRUMENTATION↗

Three-body Coulomb systems using generalized angular-momentum S states

An expansion of the three-body Coulomb potential in generalized angular-momentum eigenfunctions developed earlier by one of the authors is used to compute energy eigenvalues and eigenfunctions of bound S states of three-body Coulomb systems. The results for He, H(-), e(-)e(+)e(-), and pmu(-)p are compared with the results of other computational approaches.

Whitten, R. C.↗

Evaluation of electrostatic charge effects on the data processing system and the orbiter communication and tracking receivers

An analysis of radiated interference test results obtained from frictionally charged Orbiter TPS tile was presented. The tests included the measurement of noise pick-up by Orbiter S-band, L-band, C-band, and Ku-band antennas located beneath the tiles in a manner simulating their installation on Orbiter. In addition, the radiated field characteristics resulting from the static discharge was determined. The results are analyzed as to their effect on data bus equipment and on Orbiter Communications and Tracking (C&T) receivers. It was concluded that the radiated interference should have no effect on MDM's. However the CPU, IOP and PMU enclosures require some minor modification to assure immunity from P-static interference. Orbiter antenna tests indicate that the S-band receiver should not be affected by P-static noise. The TACAN and Radar Altimeter performance appears to be adequate but with a small margin. MSBLS performance is uncertain because laboratory instrumentation cannot approach the MSBLS sensitivity.

Lawton, R. M.↗

Dynamic Equivalence of Large-Scale Power Systems Based on Boundary Measurements

Parallel computing helped speed up many tasks that can be done independently. The advance in gaming industry did not produce a technology that helps the power industry to reduce the computation time for dynamic simulation in individual cases. To perform faster than real-time simulation for the purpose of predicting power system dynamic trajectory, power industry continues to struggle to reduce the system size and simulation time of large-scale power systems while keeping its dynamic behavior under various disturbances. There is also an acute need for real-time dynamic model reduction as more renewables enter the generation mix with dramatic changes in the generation outputs. All existing model reduction solutions are based on having access to a detailed dynamic model of the system. The system changes by the minutes, dynamic models are only updated annually. To solve this problem, wide-area measurements obtained by the phasor measurement unit (PMU) at the boundaries between the reduced system and the study system is used to represent the external area. An artificial neuro-fuzzy inference system (ANFIS) is established to perform the mapping of the measurement to the external equivalent model. Here the external area is regarded as a black-box. Model reduction studies are conducted on the Northeast Power Coordinating Council (NPCC) under various types of contingencies, by using a co-simulation approach between PSS/E and MATLAB. The results look very promising and will be discussed in this paper.

Tong, Ning↗

Online Event Detection in Synchrophasor Data with Graph Signal Processing

Online detection of anomalies is crucial to enhancing the reliability and resiliency of power systems. We propose a novel data-driven online event detection algorithm with synchrophasor data using graph signal processing. In addition to being extremely scalable, our proposed algorithm can accurately capture and leverage the spatio-temporal correlations of the streaming PMU data. This paper also develops a general technique to decouple spatial and temporal correlations in multiple time series. Finally, we develop a unique framework to construct a weighted adjacency matrix and graph Laplacian for product graph. Case studies with real-world, large-scale synchrophasor data demonstrate the scalability and accuracy of our proposed event detection algorithm. Compared to the state-of-the-art benchmark, the proposed method not only achieves higher detection accuracy but also yields higher computational efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems and methods for controlling electrical grid resources

The present invention relates to PMU-based control systems for dampening inter-area oscillations in large-scale interconnected power systems or grids to protect against a catastrophic blackout. The control systems receive phasor measurements from two or more locations on an AC transmission line and generates a power control command to a power resource on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated energy harvesting transceivers and transmitters with dual-antenna architecture for miniaturized implants and electrochemical sensors

Systems and methods for utilizing a small form-factor, wirelessly powered transceiver are disclosed. In one embodiment, a wireless powered transceiver includes a receive antenna configured to receive a receive signal, a transmit antenna configured to transmit a transmit signal, a power harvesting system including a rectifier circuit configured convert radio frequency energy from the receive signal into DC (direct current) voltage, and a power management unit (PMU) configured to set the operating mode and biasing condition of the receive and transmit circuitry blocks and provide DC voltage from the receive circuitry block to the transmit circuitry block to maintain a minimum voltage, a receiver circuitry block configured to provide energy from the receive signal to the power harvesting system, and a transmitter circuitry block including a data modulator circuit, the data modulator circuit configured to generate the transmit signal using DC voltage received from the power management unit.

Babakhani, Aydin↗

Integrated energy harvesting transceivers and transmitters with dual-antenna architecture for miniaturized implants and electrochemical sensors

Systems and methods for utilizing a small form-factor, wirelessly powered transceiver are disclosed. In one embodiment, a wireless powered transceiver includes a receive antenna configured to receive a receive signal, a transmit antenna configured to transmit a transmit signal, a power harvesting system including a rectifier circuit configured convert radio frequency energy from the receive signal into DC (direct current) voltage, and a power management unit (PMU) configured to set the operating mode and biasing condition of the receive and transmit circuitry blocks and provide DC voltage from the receive circuitry block to the transmit circuitry block to maintain a minimum voltage, a receiver circuitry block configured to provide energy from the receive signal to the power harvesting system, and a transmitter circuitry block including a data modulator circuit, the data modulator circuit configured to generate the transmit signal using DC voltage received from the power management unit.

Babakhani, Aydin↗

Synchrophasor spoofing detection and remediation for wide-area damping control

Evolving cyber-attack threats put at risk automatic closed-loop systems to be incorporated in the smart grid. Wide-area control systems are particularly vulnerable to signal spoofing attacks due to sensor remoteness and dependence on satellite communication for time synchronization. A successful cyber-attack on a wide-area controller has the potential to reduce relative stability of the power system or worse, destabilize it. As such, detection algorithms must be deployed as defense against such attacks with the ability to autonomously correct for detected tampering or misoperation. The Spoof Catch and Restore Routine (SCR 2 ), a combination of three real-time spoof detectors, each requiring limited information about the plant, is reported here. Nonlinear simulations of a compromised wide-area control system deployed in the Western Interconnection show the effectiveness of SCR 2 in detecting both delay-type and counterfeit-type spoofing attacks on wide-area sensors.

42 ENGINEERING↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phasor Based Control with the Distributed, Extensible Grid Control Platform

This paper describes how to implement Phasor Based Control (PBC) using the Distributed, Extensible Grid Control (DEGC) Platform. PBC is a novel method for controlling distributed energy resources (DER) that coordinates a centralized optimization with distributed feedback controllers to enforce voltage phasor targets. DEGC is an open source software and communication platform designed for general DER control. We deployed PBC at Lawrence Berkeley Lab's FLEXLAB test site, conducting multiple hardware-in-the-loop test runs. Here, we describe how DEGC was used to implement PBC on hardware, and results demonstrating successful deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Output-Based Inertia Estimation of Modern Power Systems

The overall inertia of modern power systems is drastically impacted by the penetration level of converter-based resources (CBRs). The intermittent output of CBRs and their dependence on the weather conditions affirm the need for a realtime inertia estimation approach. This can help the transmission system operators(TSOs) to be continuously aware of the changes in the system inertia and to take suitable control actions. This paper is a step forward to a totally data-driven framework for power system inertia estimation using the available measurements from the phasor measurement units (PMUs). This inertia estimation is done based on the spectral analysis of the so-called Koopman linear operator. Koopman operator considers the relationship between the system's inertia and its dynamical response to slight disturbances in the load. Simulation results show that Koopman operator can approximate the system behavior in a reconstructed linear space hence inertia constant is estimated accurately.

data-driven↗

Local Power-Voltage Sensitivity and Thevenin Impedance Estimation from Phasor Measurements

This paper describes how to use voltage phasor measurements to produce a sensitivity matrix that describes how real and reactive power injections at a node on a distribution network affect the local voltage magnitude and angle. Rather than estimating the sensitivity directly, the voltage phasor measurements and power commands/measurements are used to estimate the unbalanced, three-phase Thevenin impedance. The Thevenin impedance estimation is conducted using recursive least squares on temporal difference measurements. The Thevenin impedance and voltage phasor measurement are then used to build the local power-voltage sensitivity matrix with the closed form expression for the Jacobian of the power flow manifold. Hardware-in-the-loop simulations with phasor measurement units providing real phasor measurements are used to evaluate the recursive temporal difference Thevenin impedance estimation and Thevenin-based power-voltage sensitivity methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchrophasor Data Compression Under Disturbance Conditions via Cross-Entropy-Based Singular Value Decomposition

The increasing deployment of phasor measurement units and the advances of their reporting rates are challenging the present data centers in terms of storing and analyzing large-volume data. Under power system disturbance conditions, it is difficult to retain critical information while compressing the synchrophasor data effectively. This article combines the cross entropy and the singular value decomposition, proposing a novel model to compress the synchrophasor data to an extremely small size yet keep superior accuracy. The proposed model is extensively tested and compared with the state-of-the-art algorithms using the simulated and the FNET/GridEye field-collected data. The result indicates that the proposed algorithm has superior performance in compressing the data while retaining critical information under disturbance conditions.

42 ENGINEERING↗

Advanced Performance Metrics and their Application to the Sensitivity Analysis for Model Validation and Calibration

High-quality generator dynamic models are critical to reliable and accurate power systems studies and planning. With the availability of PMUs, measurement-based approach for model validation has gained significant prominence. In this approach, the quality of a model is analyzed by visually comparing measured generator response with the model-based simulated response for large system disturbances. This paper proposes a new set of performance metrics to assess the model validation results to facilitate automation of the model validation process. In the proposed methodology, first, the slow governor response and comparatively faster oscillatory response are separated, and then a separate set of performance metrics is calculated for each of these two components. These proposed metrics quantify the mismatch between the actual and model-based response in a comprehensive manner without missing any information enabling automation of the process. Furthermore, in this paper, we are also proposing that the sensitivity analysis for model calibration be performed with respect to the proposed metrics for the systematic identification of key parameters. In this work, results obtained using both simulated and real-world case-studies validate the effectiveness of the proposed performance metrics for model validation and their application to the sensitivity analysis for model calibration.

24 POWER TRANSMISSION AND DISTRIBUTION↗