Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PDD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Intermetallic Single-Atom Alloy In–Pd Bimetallene for Neutral Electrosynthesis of Ammonia from Nitrate

Harvesting recyclable ammonia (NH 3 ) from the electrocatalytic reduction of nitrate (NO 3 RR) offers a sustainable strategy to close the ecological nitrogen cycle from nitration contamination in an energy-efficient and environmentally friendly manner. The emerging intermetallic single-atom alloys (ISAAs) are recognized to achieve the highest site density of single atoms by isolating contiguous metalatoms into single sites stabilized by another metal within the intermetallic structure, which holds promise to couple the catalytic benefits from intermetallic nanocrystals and single-atom catalysts for promoting NO 3 RR. Herein, ISAA In-Pd bimetallene, in which the Pd single atoms are isolated by surrounding In atoms, is reported to boost neutral NO 3 RR with a NH 3 Faradaic efficiency(FE) of 87.2%, a yield rate of 28.06 mg h -1 mg Pd -1 , and an exceptional electrocatalytic stability with increased activity/selectivity over 100 h and 20 cycles. The ISAA structure induces substantially diminished overlap of Pdd-orbitals and narrowed p-d hybridization of In-p and Pd-d states around the Fermi level, resulting in a stronger NO 3 - adsorption and a depressed energy barrier of the potential-determining step for NO 3 RR. Finally, further integrating the NO 3 RR catalyst into a Zn-NO 3 - flow battery as the cathode delivers a power density of 12.64 mW cm -2 and a FE of 93.4% for NH 3 production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure of human TRPV4 in complex with GTPase RhoA

Transient receptor potential (TRP) channel TRPV4 is a polymodal cellular sensor that responds to moderate heat, cell swelling, shear stress, and small-molecule ligands. It is involved in thermogenesis, regulation of vascular tone, bone homeostasis, renal and pulmonary functions. TRPV4 is implicated in neuromuscular and skeletal disorders, pulmonary edema, and cancers, and represents an important drug target. The cytoskeletal remodeling GTPase RhoA has been shown to suppress TRPV4 activity. Here, we present a structure of the human TRPV4-RhoA complex that shows RhoA interaction with the membrane-facing surface of the TRPV4 ankyrin repeat domains. The contact interface reveals residues that are mutated in neuropathies, providing an insight into the disease pathogenesis. We also identify the binding sites of the TRPV4 agonist 4α-PDD and the inhibitor HC-067047 at the base of the S1-S4 bundle, and show that agonist binding leads to pore opening, while channel inhibition involves a π-to-α transition in the pore-forming helix S6. Our structures elucidate the interaction interface between hTRPV4 and RhoA, as well as residues at this interface that are involved in TRPV4 disease-causing mutations. They shed light on TRPV4 activation and inhibition and provide a template for the design of future therapeutics for treatment of TRPV4-related diseases.

59 BASIC BIOLOGICAL SCIENCES↗

Air-conditioning adoption and electricity demand highlight climate change mitigation–adaptation tradeoffs

Abstract We elucidate mid-century climate change impacts on electricity demand accounting for endogenous adoption of residential air-conditioning (AC) in affluent, cooler countries in Europe, and in poorer, hotter states in India. By 2050, in a high-warming scenario (SSP585) AC prevalence grows twofold in Europe and fourfold in India, reaching around 40% in both regions. We document a mitigation-adaptation tradeoff: AC expansion reduces daily heat exposures by 150 million and 3.8 billion person degree-days (PDDs), but increases annual electricity demand by 34 TWh and 168 TWh in Europe and India, respectively (corresponding to 2% and 15% of today’s consumption). The increase in adoption and use of AC would result in an additional 130 MMTCO2, of which 120 MMTCO2 in India alone, if the additional electricity generated were produced with today’s power mix. The tradeoff varies geographically and across income groups: a one PDD reduction in heat exposure in Europe versus India necessitates five times more electricity (0.53 kWh vs 0.1 kWh) and two times more emissions (0.16 kgCO $$_2$$ 2 vs 0.09 kgCO $$_2$$ 2 ), on average. The decomposition of demand drivers offers important insights on how such tradeoff can be moderated through policies promoting technology-based and behavioral-based adaptation strategies.

54 ENVIRONMENTAL SCIENCES↗

Electron Beam Quality Determination Through Fricke Xylenol Gel Dosimeter

According to the IAEA TRS-398 protocol, a parallel plate ionization chamber is recommended to be used in electron dosimetry. The important dosimetric parameters such as R{sub 100} and R{sub 50}, inferred from the percentage depth dose (PDD) curve, allow to obtain the electron beam average energy at the water phantom surface (material equivalent to the soft tissue). In this work, a chemical dosimeter based on the Fe(II) to Fe(III) oxidation was used to obtain the average energies from electrons beams (from nominal energies of 5, 8 and 10 MeV) and related parameters of R{sub 100}, R{sub 50} and z{sub ref}. These energies obtained through the Fricke Xylenol Gel (FXG) were compared to those with a parallel plate ionization chamber, following the cited protocol, which showed no significant differences. From these measurements one can conclude the FXG applicability for R{sub 100}, R{sub 50} and electron beam average energy determination.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reduced bleaching in organic nanofibers by bilayer polymer/oxide coating

Para-hexaphenylene (p-6P) molecules exhibit a characteristic photoinduced reaction (bleaching) resulting in a decrease in luminescence intensity upon UV light exposure, which could render the technological use of the nanofibers problematic. In order to investigate the photoinduced reaction in nanofibers, optical bleaching experiments have been performed by irradiating both pristine and coated nanofibers with UV light. Oxide coating materials (SiO{sub x} and Al{sub 2}O{sub 3}) were applied onto p-6P nanofibers. These treatments caused a reduction in the bleaching reaction but in addition, the nanofiber luminescence spectrum was significantly altered. It was observed that some polymer coatings [a statistical copolymer of tetrafluoroethylene and 2,2-bis-trifluoromethyl-4,5-difluoro-1,3-dioxole, P(TFE-PDD), and poly(methyl methacrylate), PMMA] do not interfere with the luminescence spectrum from the p-6P but are not effective in stopping the bleaching. Bilayer coatings with first a polymer material, which should work as a protection layer to avoid modifications of the p-6P luminescence spectrum, and second an oxide layer used as oxygen blocker were tested and it was found that a particular bilayer polymer/oxide combination results in a significant reduction in bleaching without affecting significantly the emission spectrum from the nanofibers.

36 MATERIALS SCIENCE↗

Photodynamic Cancer Therapy - Recent Advances

The basic principle of the photodynamic effect was discovered over a hundred years ago leading to the pioneering work on PDT in Europe. It was only during the 1980s, however, when 'photoradiation therapy' was investigated as a possible treatment modality for cancer. Photodynamic therapy (PDT) is a photochemotherapeutic process which requires the use of a photosensitizer (PS) that, upon entry into a cancer cell is targeted by laser irradiation to initiate a series of events that contribute to cell death. PSs are light-sensitive dyes activated by a light source at a specific wavelength and can be classified as first or second generation PSs based on its origin and synthetic pathway. The principle of PS activation lies in a photochemical reaction resulting from excitation of the PS producing singlet oxygen which in turn reacts and damages cell organelles and biomolecules required for cell function and ultimately leading to cell destruction. Several first and second generation PSs have been studied in several different cancer types in the quest to optimize treatment. PSs including haematoporphyrin derivative (HpD), aminolevulinic acid (ALA), chlorins, bacteriochlorins, phthalocyanines, naphthalocyanines, pheophorbiedes and purpurins all require selective uptake and retention by cancer cells prior to activation by a light source and subsequent cell death induction. Photodynamic diagnosis (PDD) is based on the fluorescence effect exhibited by PSs upon irradiation and is often used concurrently with PDT to detect and locate tumours. Both laser and light emitting diodes (LED) have been used for PDT depending on the location of the tumour. Internal cancers more often require the use of laser light delivery using fibre optics as delivery system while external PDT often make use of LEDs. Normal cells have a lower uptake of the PS in comparison to tumour cells, however the acute cytotoxic effect of the compound on the recovery rate of normal cells is not known. Subcellular localization of PS is of vital importance when cell death mechanism is identified. Programmed cell death (PCD) viz. apoptosis, necrosis and autophagy have all been identified as inducible cell death mechanisms during PDT. While apoptosis is probably the preferred cell death mechanism, understanding the molecular differences and identifying the cross-talk between these mechanisms are crucial to the development of new PSs aimed at improving the killing efficiency and overall effectiveness of PDT as a cancer treatment modality. This paper reviews the process of PDT cancer therapy, the available PSs, their effectiveness for different cancers as well as the cell death mechanisms identified during PDT of different cancers associated with specific PSs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commissioning of a Varian Clinac iX 6 MV photon beam using Monte Carlo simulation

Monte Carlo modelling of a linear accelerator is the first and most important step in Monte Carlo dose calculations in radiotherapy. Monte Carlo is considered today to be the most accurate and detailed calculation method in different fields of medical physics. In this research, we developed a photon beam model for Varian Clinac iX 6 MV equipped with MilleniumMLC120 for dose calculation purposes using BEAMnrc/DOSXYZnrc Monte Carlo system based on the underlying EGSnrc particle transport code. Monte Carlo simulation for this commissioning head LINAC divided in two stages are design head Linac model using BEAMnrc, characterize this model using BEAMDP and analyze the difference between simulation and measurement data using DOSXYZnrc. In the first step, to reduce simulation time, a virtual treatment head LINAC was built in two parts (patient-dependent component and patient-independent component). The incident electron energy varied 6.1 MeV, 6.2 MeV and 6.3 MeV, 6.4 MeV, and 6.6 MeV and the FWHM (full width at half maximum) of source is 1 mm. Phase-space file from the virtual model characterized using BEAMDP. The results of MC calculations using DOSXYZnrc in water phantom are percent depth doses (PDDs) and beam profiles at depths 10 cm were compared with measurements. This process has been completed if the dose difference of measured and calculated relative depth-dose data along the central-axis and dose profile at depths 10 cm is ≤ 5%. The effect of beam width on percentage depth doses and beam profiles was studied. Results of the virtual model were in close agreement with measurements in incident energy electron 6.4 MeV. Our results showed that photon beam width could be tuned using large field beam profile at the depth of maximum dose. The Monte Carlo model developed in this study accurately represents the Varian Clinac iX with millennium MLC 120 leaf and can be used for reliable patient dose calculations. In this commissioning process, the good criteria of dose difference in PDD and dose profiles were achieve using incident electron energy 6.4 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determining acceptable limits of fast-electron preheat in direct-drive-ignition–scale target designs

In direct-drive–ignition designs, preheat by fast electrons created by the two-plasmon–decay or stimulated Raman instabilities can increase the adiabat in the fuel layer and reduce compression and neutron yield. Since eliminating the preheat entirely is a major challenge, it is necessary to understand the levels of preheat that preclude ignition in a direct-drive target. Two 1-D ignition-scale target designs serve as the basis for examining the effects of synthetically increasing the levels of fast electrons using the 1-D radiation–hydrodynamic code LILAC , which includes two models of fast-electron transport. The first is an ignition design adapted from a 2-D polar-direct-drive (PDD) design for the National Ignition Facility (NIF). The second is derived from the first but uses a laser pulse that generates stronger shocks and a higher fuel adiabat. This more stable “alpha-burner” design approaches ignition and achieves yield multiplication as a result of alpha heating. The designs are then re optimized to recover performance. The igniting design, when fast-electron transport was modeled with diffusion, was found to tolerate 50% more fast-electron preheat of the cold (sub-50 eV) DT ice layer when the laser pulse was optimized using the optimizer Telios . When a straight-line fast-electron transport model was used, the effects of optimization were negligible. For the alpha-burner design, an increase of over a factor of at least 3 in the tolerable level of fast-electron preheat was obtained for both transport models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multisource modeling of flattening filter free (FFF) beam and the optimization of model parameters

Purpose: With the introduction of flattening filter free (FFF) linear accelerators to radiation oncology, new analytical source models for a FFF beam applicable to current treatment planning systems is needed. In this work, a multisource model for the FFF beam and the optimization of involved model parameters were designed. Methods: The model is based on a previous three source model proposed by Yang et al. [''A three-source model for the calculation of head scatter factors,'' Med. Phys. 29, 2024-2033 (2002)]. An off axis ratio (OAR) of photon fluence was introduced to the primary source term to generate cone shaped profiles. The parameters of the source model were determined from measured head scatter factors using a line search optimization technique. The OAR of the photon fluence was determined from a measured dose profile of a 40x40 cm{sup 2} field size with the same optimization technique, but a new method to acquire gradient terms for OARs was developed to enhance the speed of the optimization process. The improved model was validated with measured dose profiles from 3x3 to 40x40 cm{sup 2} field sizes at 6 and 10 MV from a TrueBeam STx linear accelerator. Furthermore, planar dose distributions for clinically used radiation fields were also calculated and compared to measurements using a 2D array detector using the gamma index method. Results: All dose values for the calculated profiles agreed with the measured dose profiles within 0.5% at 6 and 10 MV beams, except for some low dose regions for larger field sizes. A slight overestimation was seen in the lower penumbra region near the field edge for the large field sizes by 1%-4%. The planar dose calculations showed comparable passing rates (>98%) when the criterion of the gamma index method was selected to be 3%/3 mm. Conclusions: The developed source model showed good agreements between measured and calculated dose distributions. The model is easily applicable to any other linear accelerator using FFF beams as the required data include only the measured PDD, dose profiles, and output factors for various field sizes, which are easily acquired during conventional beam commissioning process.

60 APPLIED LIFE SCIENCES↗

Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc stereotactic treatments

Purpose: To assess the accuracy against measurements of two photon dose calculation algorithms (Acuros XB and the Anisotropic Analytical algorithm AAA) for small fields usable in stereotactic treatments with particular focus on RapidArc. Methods: Acuros XB and AAA were configured for stereotactic use. Baseline accuracy was assessed on small jaw-collimated open fields for different values for the spot sizes parameter in the beam data: 0.0, 0.5, 1, and 2 mm. Data were calculated with a grid of 1 x 1 mm{sup 2}. Investigated fields were: 3 x 3, 2 x 2, 1 x 1, and 0.8 x 0.8 cm{sup 2} with a 6 MV photon beam generated from a Clinac2100iX (Varian, Palo Alto, CA). Profiles, PDD, and output factors were measured in water with a PTW diamond detector (detector size: 4 mm{sup 2}, thickness 0.4 mm) and compared to calculations. Four RapidArc test plans were optimized, calculated and delivered with jaw settings J3 x 3, J2 x 2, and J1 x 1 cm{sup 2}, the last was optimized twice to generate high (H) and low (L) modulation patterns. Each plan consisted of one partial arc (gantry 110 deg. to 250 deg.), and collimator 45 deg. Dose to isocenter was measured in a PTW Octavius phantom and compared to calculations. 2D measurements were performed by means of portal dosimetry with the GLAaS method developed at authors' institute. Analysis was performed with gamma pass-fail test with 3% dose difference and 2 mm distance to agreement thresholds. Results: Open square fields: penumbrae from open field profiles were in good agreement with diamond measurements for 1 mm spot size setting for Acuros XB, and between 0.5 and 1 mm for AAA. Maximum MU difference between calculations and measurements was 1.7% for Acuros XB (0.2% for fields greater than 1 x 1 cm{sup 2}) with 0.5 or 1 mm spot size. Agreement for AAA was within 0.7% (2.8%) for 0.5 (1 mm) spot size. RapidArc plans: doses were evaluated in a 4 mm diameter structure at isocenter and computed values differed from measurements by 0.0, -0.2, 5.5, and -3.4% for Acuros XB calculations (1 mm spot size), and of -0.1, 0.3, 6.7, and -1.2% for AAA, respectively for J3 x 3, J2 x 2, J1 x 1H, J1 x 1L RapidArc plans. Gamma Agreement Index from 2D dose analysis was higher than 95% for J3 x 3 and J2 x 2 plans, being around 80% for J1 x 1 maps. Sensitivity with respect to the dosimetric leaf gap and transmission factor MLC parameters was evaluated in the four RapidArc plans, showing the need to properly set the dosimetric leaf gap for accurate calculations. Conclusions: Acuros XB and AAA showed acceptable characteristics for stereotactic small fields if adequate tuning of configuration parameters is performed. Dose calculated for RapidArc stereotactic plans showed an acceptable agreement against point and 2D measurements. Both algorithms can therefore be considered safely applicable to stereotactic treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluating dosimetric accuracy of flattening filter free compensator-based IMRT: Measurements with diode arrays

Purpose: Compensator-based IMRT coupled with the high dose rate flattening filter free (FFF) beams offers an intriguing possibility of delivering an intensity modulated radiation field in just a few seconds. As a first step, the authors evaluate the dosimetric accuracy of the treatment planning system (TPS) FFF beam model with compensators. Methods: A 6 MV FFF beam from a TrueBeam accelerator (Varian Medical Systems, Palo Alto CA) was modeled in PINNACLE TPS (v. 9.0, Philips Radiation Oncology, Fitchburg WI). Flat brass slabs from 0.3 to 7 cm thick and an 18 deg. brass wedge were used to adjust the beam model. A 2D (MAPCHECK) and 3D (ARCCHECK) diode arrays (Sun Nuclear Corp, Melbourne FL), were investigated for use with the compensator FFF beams. Corrections for diode sensitivity caused by the spectral changes in the beam were introduced. Four compensator plans based on the AAPM TG-119 report were developed. A composite ion chamber measurement, beam by beam MAPCHECK measurements, and a composite ARCCHECK measurement were performed. The array results were analyzed with the same thresholds as in TG-119 report--3%/3 mm with global dose normalization--as well as with the more stringent combinations of the gamma analysis criteria. Results: The FFF beam shows a greater variation of the effective attenuation coefficient with brass thickness due to the prevalence of the low energy photons compared to the conventional 6X beam. As a result, a compromise had to be made while trying to achieve dose agreement for a combination of field sizes, brass thicknesses, and measurement depths ({>=}5 cm in water). An agreement of measured and calculated dose to within 1% was observed for brass thicknesses up to 2 cm. For the 3 cm slab, an error of up to 2.8% was noted for the field sizes above 10 x 10 cm{sup 2}, and up to 3.8% for the 5 x 5 cm{sup 2} field. Both diode arrays exhibit a substantial sensitivity drop as the compensator thickness increases, reaching 10% for a 7 cm brass slab. A simple correction based on the brass thickness along the ray was introduced to counteract this effect. Pooled for five profiles, the average ratio of uncorrected and corrected MAPCHECK to ion chamber readings are 0.966 and 1.008, respectively. With the proper correction, all MAPCHECK measurement to calculation comparisons exhibit 100%{gamma}(3%/3 mm) passing rates with global dose-error normalization. For the TG-119-type plans, the average {gamma}(2%/2 mm) passing rate with local normalization is 94% (range 87.8%-98.3%). The lower ARCCHECK{gamma}-analysis passing rates (corrected for diode sensitivity) are predictable based on the observed PDD discrepancies. However, with the 3%/3 mm thresholds and global normalization, the average {gamma}-analysis passing rate is 96.4% (range 89.9%-100%). Conclusions: MAPCHECK analysis demonstrates high passing rates with the stringent {gamma}(2%/2 mm) and local normalization criteria combination. The geometry of the ARCCHECK array creates a stress test for the FFF TPS model because of the shallow depth of the entrance diodes and large air cavity. Hence, the ARCCHECK{gamma}-analysis passing rates are lower than with the MAPCHECK, while still on par with TG-119.

61 RADIATION PROTECTION AND DOSIMETRY↗

Linearization of dose-response curve of the radiochromic film dosimetry system

Purpose: Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present result of our efforts to obtain a functional form that would linearize the inherently nonlinear dose-response curve of the radiochromic film dosimetry system. Methods: Functional form [{zeta}= (-1){center_dot}netOD{sup (2/3)}/ln(netOD)] was derived from calibration curves of various previously established radiochromic film dosimetry systems. In order to test the invariance of the proposed functional form with respect to the film model used we tested it with three different GAFCHROMIC Trade-Mark-Sign film models (EBT, EBT2, and EBT3) irradiated to various doses and scanned on a same scanner. For one of the film models (EBT2), we tested the invariance of the functional form to the scanner model used by scanning irradiated film pieces with three different flatbed scanner models (Epson V700, 1680, and 10000XL). To test our hypothesis that the proposed functional argument linearizes the response of the radiochromic film dosimetry system, verification tests have been performed in clinical applications: percent depth dose measurements, IMRT quality assurance (QA), and brachytherapy QA. Results: Obtained R{sup 2} values indicate that the choice of the functional form of the new argument appropriately linearizes the dose response of the radiochromic film dosimetry system we used. The linear behavior was insensitive to both film model and flatbed scanner model used. Measured PDD values using the green channel response of the GAFCHROMIC Trade-Mark-Sign EBT3 film model are well within {+-}2% window of the local relative dose value when compared to the tabulated Cobalt-60 data. It was also found that criteria of 3%/3 mm for an IMRT QA plan and 3%/2 mm for a brachytherapy QA plan are passing 95% gamma function points. Conclusions: In this paper, we demonstrate the use of functional argument to linearize the inherently nonlinear response of a radiochromic film based reference dosimetry system. In this way, relative dosimetry can be conveniently performed using radiochromic film dosimetry system without the need of establishing calibration curve.

60 APPLIED LIFE SCIENCES↗

Development and optimization of a beam shaper device for a mobile dedicated IOERT accelerator

Purpose: The aim of this study was to design and build a prototype beam shaper to be used on a dedicated mobile accelerator that protects organs at risk within the radiation field and conforms the beam to the target geometry during intraoperative electron radiotherapy (IOERT). A dosimetric characterization of the beam shaper device was performed based on Monte Carlo (MC) simulations, as well as experimental data, at different energies, field sizes, and source to skin distances. Methods: A mobile light intraoperative accelerator (LIAC{sup Registered-Sign }, Sordina, Italy) was used. The design of the beam shaper prototype was based on MC simulations (BEAMnrc/OMEGA and DOSXYZnrc code) for a selection of materials and thicknesses, as well as for dosimetric characterization. Percentage depth dose (PDD) and profile measurements were performed using a p-type silicon diode and a commercial water phantom, while output factors were measured using a PinPoint ion chamber in a PMMA phantom. Planar doses in planes of interest were carried out using radiochromic films (Gafchromic{sup TM} EBT and EBT2) in PMMA and in a Solid Water{sup Registered-Sign} phantom. Several experimental set-ups were investigated with the beam shaper device fixed on the top of the phantom, varying both the short side of the rectangular field and the air gap between the device and the phantom surface, simulating the clinical situation. The output factors (OFs) were determined using different geometrical set-ups and energies. Results: The beam shaper prototype consists of four blades sliding alongside each other and mounted on a special support at the end of the 10 cm diameter PMMA circular applicator. Each blade is made of an upper layer of 2.6 cm of Teflon{sup Registered-Sign} and a lower layer of 8 mm of stainless steel. All rectangles inscribed in a 5 cm diameter can be achieved in addition to any 'squircle-shaped' field. When one side of the rectangular field is held constant and the second side is reduced, both R{sub 50} and R{sub max} move towards the phantom surface. Comparing the PDDs obtained with the 5 cm circular applicator and with a 4.4 Multiplication-Sign 4.4 cm{sup 2} square field (that is the equivalent square of the 5 cm circular field) obtained with the beam shaper, a different behavior was observed in the region extending from the surface to a depth of 50% of the maximum dose. Isodoses measured for rectangular fields used for clinical cases (i.e., 4 Multiplication-Sign 9 cm{sup 2} 8 MeV) are shown, with different air gaps. For each energy investigated, the normalized OFs slowly increase, when the length of the side decreases down to about 4 cm, and then rapidly decreases for smaller field widths. MC simulation showed an excellent agreement with experimental data (<2%). Conclusions: The beam shaper device is able to provide square/rectangular/squircle fields with adequate dose homogeneity for mobile dedicated accelerators, thus allowing conformal treatment with IOERT. Monte Carlo simulation can be a very useful tool to simulate any clinical set up and can be used to create a data set to calculate MUs, thereby increasing the accuracy of the delivered dose during IOERT procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and dosimetric characteristics of a new endocavitary contact radiotherapy system using an electronic brachytherapy source

Purpose: To present design aspects and acceptance tests performed for clinical implementation of electronic brachytherapy treatment of early stage rectal adenocarcinoma. A dosimetric comparison is made between the historically used Philips RT-50 unit and the newly developed Axxent{sup Registered-Sign} Model S700 electronic brachytherapy source manufactured by Xoft (iCad, Inc.). Methods: Two proctoscope cones were manufactured by ElectroSurgical Instruments (ESI). Two custom surface applicators were manufactured by Xoft and were designed to fit and interlock with the proctoscope cones from ESI. Dose rates, half value layers (HVL), and percentage depth dose (PDD) measurements were made with the Xoft system and compared to historical RT-50 data. A description of the patient treatment approach and exposure rates during the procedure is also provided. Results: The electronic brachytherapy system has a lower surface dose rate than the RT-50. The dose rate to water on the surface from the Xoft system is approximately 2.1 Gy/min while the RT-50 is 10-12 Gy/min. However, treatment times with Xoft are still reasonable. The HVLs and PDDs between the two systems were comparable resulting in similar doses to the target and to regions beyond the target. The exposure rate levels around a patient treatment were acceptable. The standard uncertainty in the dose rate to water on the surface is approximately {+-}5.2%. Conclusions: The Philips RT-50 unit is an out-of-date radiotherapy machine that is no longer manufactured with limited replacement parts. The use of a custom-designed proctoscope and Xoft surface applicators allows delivery of a well-established treatment with the ease of a modern radiotherapy device. While the dose rate is lower with the use of Xoft, the treatment times are still reasonable. Additionally, personnel may stand farther away from the Xoft radiation source, thus potentially reducing radiation exposure to the operator and other personnel.

60 APPLIED LIFE SCIENCES↗

A Monte Carlo approach to validation of FFF VMAT treatment plans for the TrueBeam linac

Purpose: To commission and benchmark a vendor-supplied (Varian Medical Systems) Monte Carlo phase-space data for the 6 MV flattening filter free (FFF) energy mode on a TrueBeam linear accelerator for the purpose of quality assurance of clinical volumetric modulated arc therapy (VMAT) treatment plans. A method for rendering the phase-space data compatible with BEAMnrc/DOSXYZnrc simulation software package is presented. Methods: Monte Carlo (MC) simulations were performed to benchmark the TrueBeam 6 MV FFF phase space data that have been released by the Varian MC Research team. The simulations to benchmark the phase space data were done in three steps. First, the original phase space which was created on a cylindrical surface was converted into a format that was compatible with BEAMnrc. Second, BEAMnrc was used to create field size specific phase spaces located underneath the jaws. Third, doses were calculated with DOSXYZnrc in a water phantom for fields ranging from 1 Multiplication-Sign 1 to 40 Multiplication-Sign 40 cm{sup 2}. Calculated percent depth doses (PDD), transverse profiles, and output factors were compared with measurements for all the fields simulated. After completing the benchmarking study, three stereotactic body radiotherapy (SBRT) VMAT plans created with the Eclipse treatment planning system (TPS) were calculated with Monte Carlo. Ion chamber and film measurements were also performed on these plans. 3D gamma analysis was used to compare Monte Carlo calculation with TPS calculations and with film measurement. Results: For the benchmarking study, MC calculated and measured values agreed within 1% and 1.5% for PDDs and in-field transverse profiles, respectively, for field sizes >1 Multiplication-Sign 1 cm{sup 2}. Agreements in the 80%-20% penumbra widths were better than 2 mm for all the fields that were compared. With the exception of the 1 Multiplication-Sign 1 cm{sup 2} field, the agreement between measured and calculated output factors was within 1%. It is of note that excellent agreement in output factors for all field sizes including highly asymmetric fields was achieved without accounting for backscatter into the beam monitor chamber. For the SBRT VMAT plans, the agreement between Monte Carlo and ion chamber point dose measurements was within 1%. Excellent agreement between Monte Carlo, treatment planning system and Gafchromic film dose distribution was observed with over 99% of the points in the high dose volume passing the 3%, 3 mm gamma test. Conclusions: The authors have presented a method for making the Varian IAEA compliant 6 MV FFF phase space file of the TrueBeam linac compatible with BEAMnrc/DOSXYZnrc. After benchmarking the modified phase space against measurement, they have demonstrated its potential for use in MC based quality assurance of complex delivery techniques.

60 APPLIED LIFE SCIENCES↗

Commissioning of the Varian TrueBeam linear accelerator: A multi-institutional study

Purpose: Latest generation linear accelerators (linacs), i.e., TrueBeam (Varian Medical Systems, Palo Alto, CA) and its stereotactic counterpart, TrueBeam STx, have several unique features, including high-dose-rate flattening-filter-free (FFF) photon modes, reengineered electron modes with new scattering foil geometries, updated imaging hardware/software, and a novel control system. An evaluation of five TrueBeam linacs at three different institutions has been performed and this work reports on the commissioning experience. Methods: Acceptance and commissioning data were analyzed for five TrueBeam linacs equipped with 120 leaf (5 mm width) MLCs at three different institutions. Dosimetric data and mechanical parameters were compared. These included measurements of photon beam profiles (6X, 6XFFF, 10X, 10XFFF, 15X), photon and electron percent depth dose (PDD) curves (6, 9, 12 MeV), relative photon output factors (Scp), electron cone factors, mechanical isocenter accuracy, MLC transmission, and dosimetric leaf gap (DLG). End-to-end testing and IMRT commissioning were also conducted. Results: Gantry/collimator isocentricity measurements were similar (0.27-0.28 mm), with overall couch/gantry/collimator values of 0.46-0.68 mm across the three institutions. Dosimetric data showed good agreement between machines. The average MLC DLGs for 6, 10, and 15 MV photons were 1.33 {+-} 0.23, 1.57 {+-} 0.24, and 1.61 {+-} 0.26 mm, respectively. 6XFFF and 10XFFF modes had average DLGs of 1.16 {+-} 0.22 and 1.44 {+-} 0.30 mm, respectively. MLC transmission showed minimal variation across the three institutions, with the standard deviation <0.2% for all linacs. Photon and electron PDDs were comparable for all energies. 6, 10, and 15 MV photon beam quality, %dd(10){sub x} varied less than 0.3% for all linacs. Output factors (Scp) and electron cone factors agreed within 0.27%, on average; largest variations were observed for small field sizes (1.2% coefficient of variation, 10 MV, 2 Multiplication-Sign 2 cm{sup 2}) and small cone sizes (<1% coefficient of variation, 6 Multiplication-Sign 6 cm{sup 2} cone), respectively. Conclusions: Overall, excellent agreement was observed in TrueBeam commissioning data. This set of multi-institutional data can provide comparison data to others embarking on TrueBeam commissioning, ultimately improving the safety and quality of beam commissioning.

43 PARTICLE ACCELERATORS↗

Feasibility of producing a short, high energy s-band linear accelerator using a klystron power source

Purpose: To use a finite-element method (FEM) model to study the feasibility of producing a short s-band (2.9985 GHz) waveguide capable of producing x-rays energies up to 10 MV, for applications in a linac-MR, as well as conventional radiotherapy. Methods: An existing waveguide FEM model developed by the authors' group is used to simulate replacing the magnetron power source with a klystron. Peak fields within the waveguide are compared with a published experimental threshold for electric breakdown. The RF fields in the first accelerating cavity are scaled, approximating the effect of modifications to the first coupling cavity. Electron trajectories are calculated within the RF fields, and the energy spectrum, beam current, and focal spot of the electron beam are analyzed. One electron spectrum is selected for Monte Carlo simulations and the resulting PDD compared to measurement. Results: When the first cavity fields are scaled by a factor of 0.475, the peak magnitude of the electric fields within the waveguide are calculated to be 223.1 MV/m, 29% lower than the published threshold for breakdown at this operating frequency. Maximum electron energy increased from 6.2 to 10.4 MeV, and beam current increased from 134 to 170 mA. The focal spot FWHM is decreased slightly from 0.07 to 0.05 mm, and the width of the energy spectrum increased slightly from 0.44 to 0.70 MeV. Monte Carlo results show d{sub max} is at 2.15 cm for a 10 Multiplication-Sign 10 cm{sup 2} field, compared with 2.3 cm for a Varian 10 MV linac, while the penumbral widths are 4.8 and 5.6 mm, respectively. Conclusions: The authors' simulation results show that a short, high-energy, s-band accelerator is feasible and electric breakdown is not expected to interfere with operation at these field strengths. With minor modifications to the first coupling cavity, all electron beam parameters are improved.

60 APPLIED LIFE SCIENCES↗

The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined initially and weekly during the course of radiotherapy.Results: For a RapidArc treatment technique, the backscatter dose from the DFM insert was measured to be 9.25 ± 2.17 in the IMRT-verification-phantom. The measured backscatter upstream dose from DFM for a single-field was 22% higher than without the DFM, whereas the downstream dose was lower by 14%. The values of homogeneity index for the plans with and without the application of mask were 0.09 and 0.14, respectively. The calculated mean treatment planning volume (PTV) dose differed from the delivered dose by 13% and was reduced to 2% when using the mask and virtual filter together. A grade 3 mucosa reaction was observed in the control group after 22–24 fractions (44–48 Gy). In contrast, no grade 3 mucositis was observed in the patients wearing the PDM after 25–26 fractions (50–52 Gy).Conclusions: The backscatter from the DFM for a single, parallel-opposed fields, and RapidArc treatment technique was found significant. The application of mask in replacing streaking artifacts can be useful in improving dose homogeneity in the PTV. The use of a virtual filter around the teeth during the planning phase reduces the target underdosage issue in the phantom. Furthermore, a reduction in mucositis is observed in the head and neck patients with the use of PDM.

61 RADIATION PROTECTION AND DOSIMETRY↗