Spectroscopy along flerovium decay chains. II. Fine structure in odd- A Fl 289
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Excited states in the neutron-deficient nuclide Hf 155 have been investigated in experiments performed at the Accelerator Laboratory of the University of Jyväskylä. The Hf 155 nuclei were produced in fusion-evaporation reactions induced by beams of 295 and 315 MeV Ni 58 ions bombarding an isotopically enriched Pd 102 target and separated using the recoil mass separator MARA. An isomeric state having a half-life of 510(30) ns was discovered and is interpreted as a seniority υ = 3 , ( π h 11 / 2 2 ⊗ ν f 7 / 2 ) 27 / 2 − configuration. The γ -ray transitions emitted in the deexcitation of the isomeric state to the ground state were identified and a level scheme was constructed, from which the excitation energy of the isomer was determined to be 2581.5(10) keV. A B ( E 2 ) value of 0.45(3) W.u. was deduced for the 105.4 keV transition depopulating the isomeric state. The deduced level scheme and B ( E 2 ) value are compared with systematics and shell-model calculations. Published by the American Physical Society 2024
Here, a quantitative description of the change in ground-state neutron occupancies between 136 Xe and 136 Ba, the initial and final state in the neutrinoless double-β decay of 136 Xe, has been extracted from precision measurements of the cross sections of single-neutron-adding and -removing reactions. Comparisons are made to recent theoretical calculations of the same properties using various nuclear-structure models. These are the same calculations used to determine the magnitude of the nuclear matrix elements for the process, which at present disagree with each other by factors of 2 or 3. The experimental neutron occupancies show some disagreement with the theoretical calculations.
Not Available
Not provided.
Enzymes exist in ensembles of states that encode the energetics underlying their catalysis. Conformational ensembles built from 1231 structures of 17 serine proteases revealed atomic-level changes across their reaction states. By comparing the enzymatic and solution reaction, we identified molecular features that provide catalysis and quantified their energetic contributions to catalysis. Serine proteases precisely position their reactants in destabilized conformers, creating a downhill energetic gradient that selectively favors the motions required for reaction while limiting off-pathway conformational states. The same catalytic features have repeatedly evolved in proteases and additional enzymes across multiple distinct structural folds. In conclusion, our ensemble-function analyses revealed previously unknown catalytic features, provided quantitative models based on simple physical and chemical principles, and identified motifs recurrent in nature that may inspire enzyme design.
At continuous phase transitions, quantum many-body systems exhibit complex, emergent behavior. Most notably, at a quantum critical point, correlations decay as a power law, with exponents determined by a set of universal scaling dimensions. Experimentally probing such power law correlations is extremely challenging, owing to the interplay between decoherence, the vanishing energy gap, and boundary effects. In this work, we used a Rydberg quantum simulator to adiabatically prepare critical ground states of both a one-dimensional ring and a two-dimensional square lattice. By accounting for and tuning the openness of our quantum system, which is well-captured by a single phenomenological length scale, we directly observed power law correlations and extracted the corresponding scaling dimensions. Our work complements recent studies of quantum criticality that use the Kibble-Zurek mechanism and digital quantum circuits.
Background: Rotavirus (RV) nonstructural protein 4 (NSP4) is the first described viral enterotoxin, which induces early secretory diarrhea in neonatal rodents. Our previous data show a direct interaction between RV NSP4 and the structural protein of caveolae, caveolin-1 (cav-1), in yeast and mammalian cells. The binding site of cav-1 mapped to the NSP4 amphipathic helix, and led us to examine which helical face was responsible for the interaction. Methods: A panel of NSP4 mutants were prepared and tested for binding to cav-1 by yeast two hybrid and direct binding assays. The charged residues of the NSP4 amphipathic helix were changed to alanine (NSP4 46-175 -ala6); and three residues in the hydrophobic face were altered to charged amino acids (NSP4 46-175 -HydroMut). In total, twelve mutants of NSP4 were generated to define the cav-1 binding site. Synthetic peptides corresponding to the hydrophobic and charged faces of NSP4 were examined for structural changes by circular dichroism (CD) and diarrhea induction by a neonatal mouse study. Results: Mutations of the hydrophilic face (NSP4 46-175 -Ala6) bound cav-1 akin to wild type NSP4. In contrast, disruption of the hydrophobic face (NSP 446-175 -HydroMut) failed to bind cav-1. These data suggest NSP4 and cav-1 associate via a hydrophobic interaction. Analyses of mutant synthetic peptides in which the hydrophobic residues in the enterotoxic domain of NSP4 were altered suggested a critical hydrophobic residue. Both NSP4 HydroMut112-140 , that contains three charged amino acids (aa113, 124, 131) changed from the original hydrophobic residues and NSP4 AlaAcidic112-140 that contained three alanine residues substituted for negatively charged (aa114, 125, 132) amino acids failed to induce diarrhea. Whereas peptides NSP4wild type 112 -140 and NSP4 AlaBasic112-140 that contained three alanine substituted for positively charged (aa115, 119, 133) amino acids, induced diarrhea. Conclusions: These data show that the cav-1 binding domain is within the hydrophobic face of the NSP4 amphipathic helix. The integrity of the helical structure is important for both cav-1 binding and diarrhea induction implying a connection between NSP4 functional and binding activities.
Rotavirus NSP 4 localizes to multiple intracellular sites and is multifunctional, contributing to RV morphogenesis, replication and pathogenesis. One function of NSP 4 is the induction of early secretory diarrhea by binding surface receptors to initiate signaling events. The aims of this study were to determine the transport kinetics of NSP 4 to the exofacial plasma membrane (PM), the subsequent release from intact infected cells, and rebinding to naïve and/or neighboring cells in two cell types. Transport kinetics was evaluated using surface-specific biotinylation/streptavidin pull-downs and exofacial exposure of NSP 4 was confirmed by antibody binding to intact cells, and fluorescent resonant energy transfer. Transfected cells similarly were monitored to discern NSP 4 movement in the absence of infection or other viral proteins. Endoglycosidase H digestions, preparation of CY 3- or CY 5- labeled F(ab) 2 fragments, confocal imaging, and determination of preferential polarized transport employed standard laboratory techniques. Mock-infected, mock-biotinylated and non-specific antibodies served as controls. Only full-length (FL), endoglycosidase-sensitive NSP 4 was detected on the exofacial surface of two cell types, whereas the corresponding cell lysates showed multiple glycosylated forms. The C-terminus of FL NSP 4 was detected on exofacial-membrane surfaces at different times in different cell types prior to its release into culture media. Transport to the PM was rapid and distinct yet FL NSP 4 was secreted from both cell types at a time similar to the release of virus. NSP 4 -containing, clarified media from both cells bound surface molecules of naïve cells, and imaging showed secreted NSP 4 from one or more infected cells bound neighboring cell membranes in culture. Preferential sorting to apical or basolateral membranes also was distinct in different polarized cells. The intracellular transport of NSP 4 to the PM, translocation across the PM, exposure of the Cterminus on the cell surface and subsequent secretion occurs via an unusual, complex and likely cell-dependent process. The exofacial exposure of the C-terminus poses several questions and suggests an atypical mechanism by which NSP 4 traverses the PM and interacts with membrane lipids. Mechanistic details of the unconventional trafficking of NSP 4 , interactions with host-cell specific molecules and subsequent release require additional study.
Older heating systems often suffer from mis-investment—multiple contractors upgrading parts of systems in inadequate or inappropriate ways that reduce system functionality and efficiency—or from a lack of proper maintenance. This technical report addresses these barriers to information, contractor resources, and cost-savings. Building off of previous research, CNT Energy conducted a study to identify best practices for the methodology, typical costs, and energy savings associated with steam; system balancing.
This is a meeting overview of 'The Best Approach to Combustion Safety in a Direct Vent World', held June 28, 2012, in San Antonio, Texas. The objective of this Expert Meeting was to identify gaps and barriers that need to be addressed by future research, and to develop data-driven technical recommendations for code updates so that a common approach for combustion safety can be adopted by all members of the building energy efficiency and code communities.
This report was written as a resource for professionals involved in multifamily audits, retrofit delivery, and program design, as well as for building owners and contractors. It is intended to serve as a guide for those looking to evaluate and improve the efficiency and operation of one-pipe steam heating systems. In centrally heated multifamily buildings with steam or hydronic systems, the cost of heat for tenants is typically absorbed into the owner's operating costs. Highly variable and rising energy costs have placed a heavy burden on landlords. In the absence of well-designed and relevant efficiency efforts, increased operating costs would be passed on to tenants who often cannot afford those increases. Misinvestment is a common problem with older heating systems -- multiple contractors may inadequately or inappropriately upgrade parts of systems and reduce system functionality and efficiency, or the system has not been properly maintained.
Through the Chicagoland Single Family Housing Characterization and Retrofit Prioritization report, the Partnership for Advanced Residential Retrofit characterized 15 housing types in the Chicagoland region based on assessor data, utility billing history, and available data from prior energy efficiency programs. Within these 15 groups, a subset showed the greatest opportunity for energy savings based on BEopt Version 1.1 modeling of potential energy efficiency package options and the percent of the housing stock represented by each group. In this project, collected field data from a whole-home program in Illinois are utilized to compare marketplace-installed measures to the energy saving optimal packages previously developed for the 15 housing types. Housing type, conditions, energy efficiency measures installed, and retrofit cost information were collected from 19 homes that participated in the Illinois Home Performance with ENERGY STAR program in 2012, representing eight of the characterized housing groups. Two were selected for further case study analysis to provide an illustration of the differences between optimal and actually installed measures. Taken together, these homes are representative of 34.8% of the Chicagoland residential building stock. In one instance, actual installed measures closely matched optimal recommended measures.
Steam heated buildings often suffer from uneven heating as a result of poor control of the amount of steam entering each radiator. In order to satisfy the heating load to the coldest units, other units are overheated. As a result, some tenants complain of being too hot and open their windows in the middle of winter, while others complain of being too cold and are compelled to use supplemental heat sources.
Steam heated buildings often suffer from uneven heating as a result of poor control of the amount of steam entering each radiator. In order to satisfy the heating load to the coldest units, other units are overheated. As a result, some tenants complain of being too hot and open their windows in the middle of winter, while others complain of being too cold and are compelled to use supplemental heat sources. Building on previous research, CNT Energy identified 10 test buildings in Chicago and conducted a study to identify best practices for the methodology, typical costs, and energy savings associated with steam system balancing. A package of common steam balancing measures was assembled and data were collected on the buildings before and after these retrofits were installed to investigate the process, challenges, and the cost effectiveness of improving steam systems through improved venting and control systems. The test buildings that received venting upgrades and new control systems showed 10.2% savings on their natural gas heating load, with a simple payback of 5.1 years. The methodologies for and findings from this study are presented in detail in this report. This report has been updated from a version published in August 2012 to include natural gas usage information from the 2012 heating season and updated natural gas savings calculations.
This Measure Guideline covers how to assess and carry out the combustion safety procedures for appliances and heating equipment that uses indoor air for combustion in low-rise residential buildings. Only appliances installed in the living space, or in an area freely communicating with the living space, vented alone or in tandem with another appliance are considered here. A separate Measure Guideline addresses combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage that use outdoor air for combustion. This document is for inspectors, auditors, and technicians working in homes where energy upgrades are being conducted whether or not air infiltration control is included in the package of measures being applied. In the indoor combustion air case, guidelines summarized here are based on language provided in several of the codes to establish minimum requirements for the space using simplified prescriptive measures. In addition, building performance testing procedures are provided by testing agencies. The codes in combination with the test procedures offer comprehensive combustion safety coverage to address safety concerns, allowing inexperienced residential energy retrofit inspectors to effectively address combustion safety issues and allow energy retrofits to proceed.