Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Oregon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Multiple Holocene Earthquakes on the Gales Creek Fault, Northwest Oregon Fore-Arc

Several potentially hazardous northwest–striking faults in and around the Portland basin, within the fore-arc of Cascadia, are classified as Quaternary active by the U.S. Geological Survey, but little is known about their Holocene activity. We present new earthquake–timing constraints on the Gales Creek fault (GCF), a 73 km long, northwest–trending fault with youthful geomorphic expression located about 35 km west of Portland. We excavated a paleoseismic trench across the GCF in the populated northern Willamette Valley and document three surface-rupturing earthquakes from stratigraphic and structural relationships. Radiocarbon samples from offset stratigraphy constrain these earthquakes to have occurred ~1000, ~4200, and ~8800 calibrated years before the present. The penultimate earthquake back–tilted a buried soil into the hillslope creating accommodation space that was infilled by a colluvial deposit. The most recent earthquake faulted and formed a fissure within the penultimate colluvial deposit. Our results suggest that the GCF has a recurrence interval of ~4000 yr, and if the full 73 km length were to rupture, it would result in an M w 7.1–7.4 earthquake, providing a significant seismic hazard for the greater Portland metropolitan area.

15 GEOTHERMAL ENERGY↗

Wave Power Demonstration Project at Reedsport, Oregon

Ocean wave power can be a significant source of large-scale, renewable energy for the US electrical grid. The Electrical Power Research Institute (EPRI) conservatively estimated that 20% of all US electricity could be generated by wave energy. Ocean Power Technologies, Inc. (OPT), with funding from private sources and the US Navy, developed the PowerBuoy to generate renewable energy from the readily available power in ocean waves.

16 TIDAL AND WAVE POWER↗

Technology Solutions for New Manufactured Homes: Idaho, Oregon, and Washington Manufactured Home Builders (Fact Sheet)

The Building America Partnership for Improved Residential Construction, the Bonneville Power Administration (BPA), and Northwest Energy Works (NEW), the current Northwest Energy Efficient Manufactured Housing Program (NEEM) administrator, have been collaborating to conduct research on new specifications that would improve on the energy requirements of a NEEM home. In its role as administrator, NEW administers the technical specs, performs research and engineering analysis, implements ongoing construction quality management procedures, and maintains a central database with home tracking. This project prototyped and assessed the performances of cost-effective high performance building assemblies and mechanical systems that are not commonly deployed in the manufacturing setting. The package of measures is able to reduce energy used for space conditioning, water heating and lighting by 50 percent over typical manufactured homes produced in the northwest.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selling an Energy Efficiency Loan Portfolio in Oregon: Resale of the Craft3 loan portfolio to Self-Help Credit Union

Under the Clean Energy Works (CEW) program, Craft3 developed a loan product that widened access to financing for homeowners, offered long term funding, and collected repayments through the customer?s utility bill. The program?s success led Craft3 to pursue the sale of the loan portfolio to both mitigate its own risks and replenish funds for lending. This sale breaks new ground for energy efficiency finance and is notable as it was completed even with many novel program design elements. It replenished Craft3?s program capital and uncovered some valuable lessons that may facilitate future transactions. However, the lack of data history and the unproven nature of the loan portfolio meant that Craft3 had to limit the risk of losses to Self-Help, the purchaser of the portfolio. It remains to be seen whether this experience will pave the way for more sales of on-bill energy efficiency loan portfolios. This case study illustrates how certain program design decisions can sometimes both facilitate programmatic objectives and possibly present challenges for the sale of a portfolio of energy efficiency loans.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Merging high resolution geophysical and geochemical surveys to reduce exploration risk at glass buttes, Oregon

The engineering and studies phase of the Glass Buttes project was aimed at reducing risk during the early stages of geothermal project development. The project’s inclusion of high resolution geophysical and geochemical surveys allowed Ormat to evaluate the value of these surveys both independently and in combination to quantify the most valuable course of action for exploration in an area where structure, permeability, and temperature are the most pressing questions. The sizes of the thermal anomalies at Glass Buttes are unusually large. Over the course of Phase I Ormat acquired high resolution LIDAR data to accurately map fault manifestations at the surface and collected detailed gravity and aeromagnetic surveys to map subsurface structural features. In addition, Ormat collected airborne hyperspectral data to assist with mapping the rock petrology and mineral alteration assemblages along Glass Buttes faults and magnetotelluric (MT) survey to try to better constrain the structures at depth. Direct and indirect identification of alteration assemblages reveal not only the geochemical character and temperature of the causative hydrothermal fluids but can also constrain areas of upflow along specific fault segments. All five datasets were merged along with subsurface lithologies and temperatures to predict the most likely locations for high permeability and hot fluids. The Glass Buttes temperature anomalies include 2 areas, totaling 60 km2 (23 mi2) of measured temperature gradients over 165° C/km (10° F/100ft). The Midnight Point temperature anomaly includes the Strat-1 well with 90°C (194 °F) at 603 m (1981 ft) with a 164 °C/km (10°F/100ft) temperature gradient at bottom hole and the GB-18 well with 71°C (160 °F) at 396 m (1300 ft) with a 182°C/km (11°F/100ft) gradient. The primary area of alteration and elevated temperature occurs near major fault intersections associated with Brothers Fault Zone and Basin and Range systems. Evidence for faulting is observed in each data set as follows. Field observations include fault plane orientations, complicated fault intersections, and hydrothermal alteration apparently pre-dating basalt flows. Geophysical anomalies include large, linear gradients in gravity and aeromagnetic data with magnetic lows possibly associated with alteration. Resistivity low anomalies also appear to have offsets associated with faulting. Hyperspectral and XRF identified alteration and individual volcanic flow units, respectively. When incorporated into a 3D geologic model, the fault intersections near the highest proven temperature and geophysical anomalies provide the first priority targets at Midnight Point. Ormat geologists selected the Midnight Point 52-33 drilling target based on a combination of pre-existing drilling data, geologic field work, geophysical interpretation, and geochemical analysis. Deep temperatures of well 52-33 was lower than anticipated. Temperature gradients in the well mirrored those found in historical drilling, but they decreased below 1500 ft and were isothermal below 2000 ft.

15 GEOTHERMAL ENERGY↗

Oregon Solar Highway Program Development Manual

Manual describing how organizations might structure and develop programs to facilitate financing, construction, operation and maintenance of solar facilities on transportation system rights of way.

14 SOLAR ENERGY↗

SciDAC3 SUPER Performance Institute, University of Oregon Contributions (Final Report)

The SciDAC-3 Institute for Sustained Performance, Energy, and Resilience (SUPER) focused on developing technology and leveraging expertise towards ensuring that computational scientists could successfully exploit existing and emerging DOE high performance computing systems. To achieve this goal, SUPER was organized into research thrusts focusing on performance engineering, auto-tuning, performance tools, energy efficiency, resilience and multi-objective optimization, with a target of facilitating effective utilization of near term HPC systems. As described in this summary document, our teams’ significant insights into both application- and architecture-awareness drove numerous innovations across our stated research areas, while significantly improving the performance, portability, and functionality of numerous SciDAC partnership applications, enabling scientific simulation at unprecedented scale. Additionally, the tools, methodologies, and collaborations developed under this project will continue paying dividends as we face the challenges of forthcoming multi-petascale and exascale computing technologies.

97 MATHEMATICS AND COMPUTING↗

Electrochromic Window Demonstration at the 911 Federal Building, 911 Northeast 11th Avenue, Portland, Oregon

Switchable electrochromic (EC) windows are part of a new class of dynamic, energy-efficient technologies that enable real-time, active load management in response to weather conditions and the unique operating conditions of individual buildings. Owners can now specify a solid-state technology that reacts to various stimuli like the skin of a living entity. The technology can be controlled to address multiple criteria to achieve a more optimal energy-efficient and comfortable indoor environment than one with static or manually operated technologies. Inputs can include data on outdoor solar conditions, utility rates, occupancy status, heating, ventilation, and air conditioning (HVAC), or operating emergency or security mode. The outputs then dictate how the EC window is controlled, whether as a self-contained autonomous unit that achieves specific zonal objectives or as a part of an integrated system designed to address whole building, campus and grid-related goals. Since windows typically have a 30-year life, these dynamic qualities enable the building to be adaptable and more resilient as the environmental, operating and economic context evolves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results from Oregon State University 1 MW TRIGA reactor irradiation of uranium-238

We are studying short-lived fission product yields to improve the nuclear databases currently available to the nuclear physics community. There are three general energy groups that are cited in the nuclear databases; thermal neutron spectrum, fission neutron spectrum and mono-energetic 14 MeV. Each neutron energy spectrum produces different fission fragment distributions. The differences between thermal and fission neutron spectrum is several MeV of energy. Thermal represents neutron energies arounds 0.026 eV. Fission neutron spectrum refers to a Watt fission neutron spectrum with a mean energy of approximately 1 MeV. 14 MeV is the result mono-energetic with a small spread in energies (~0.1-0.3 MeV) usually.

42 ENGINEERING↗

Cost Effectiveness of ASHRAE Standard 90.1-2016 for the State of Oregon

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2016. Moving to the Standard 90.1-2016 edition from Standard 90.1-2013 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost-Effectiveness of ANSI/ASHRAE/IES Standard 90.1-2019 for Oregon

This report describes the methodology and results of a state cost-effectiveness analysis of ASHRAE Standard 90.1-2019. Moving to the Standard 90.1-2019 edition from Standard 90.1-2016 is found to be cost-effective for the state. Annual energy cost savings, added construction costs, and life-cycle costs are all described and presented here for various building types and climate zones.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sodar - PNNL Scintec MFAS, Oregon Raceway Park - Reviewed Data

These data provide measurements of wind speed and direction up to 400 m above ground level (AGL) (max). The data are stored in two forms: ASCII and raw (binary). ASCII files contain averaged data (currently: 15 min time step and 10 m range gate). Raw files can be reprocessed with sodar software (APRun by Scintec) to produce ASCII files with different time and/or height averaging settings (highest resolution is approximately 90 sec and 10 m). NOTE: Wind direction is reported with respect to magnetic North.

17 WIND ENERGY↗