Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operator regression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Bilinear dynamic mode decomposition for quantum control

Abstract Data-driven methods for establishing quantum optimal control (QOC) using time-dependent control pulses tailored to specific quantum dynamical systems and desired control objectives are critical for many emerging quantum technologies. We develop a data-driven regression procedure, bilinear dynamic mode decomposition (biDMD), that leverages time-series measurements to establish quantum system identification for QOC. The biDMD optimization framework is a physics-informed regression that makes use of the known underlying Hamiltonian structure. Further, the biDMD can be modified to model both fast and slow sampling of control signals, the latter by way of stroboscopic sampling strategies. The biDMD method provides a flexible, interpretable, and adaptive regression framework for real-time, online implementation in quantum systems. Further, the method has strong theoretical connections to Koopman theory, which approximates nonlinear dynamics with linear operators. In comparison with many machine learning paradigms minimal data is needed to construct a biDMD model, and the model is easily updated as new data is collected. We demonstrate the efficacy and performance of the approach on a number of representative quantum systems, showing that it also matches experimental results.

97 MATHEMATICS AND COMPUTING↗

Mechanistic Modeling of TEG Dehydrator Emissions in Oil and Gas Industry

This work presents a mechanistic modeling approach for simulating methane emissions from triethylene glycol (TEG) dehydrators used in oil & gas (O&G) operations. The model was developed as a modular component of the Mechanistic Air Emissions Simulator (MAES) tool, incorporating species-specific absorption and emission dynamics through two-level, second-order polynomial regression (PR) models trained on ProMax simulation data: (1) species-level regression models that track the transfer rates of individual gas species within the dehydrator unit streams, and (2) outlet flow stream regression models that predict the fraction of inlet gas distributed among the outlet streams of the dehydrator unit. These behaviors were characterized over a range of glycol circulation ratios, wet gas pressures, and temperatures. The model was validated using root mean square error (RMSE) analysis. The species-level PR achieved low root mean square error (RMSE) values (<0.03) for light hydrocarbon species across all dehydrator components, ranging from 0.0009 for methane to 0.029 for normal pentane. Similarly, the outlet-level PR yielded RMSE values below 0.002 for the dry gas fraction, 0.001 for the flash tank fraction, and 0.002 for the still vent fraction, demonstrating strong agreement between predicted and reference ProMax values. When deployed at field facilities, the model significantly improved MAES-simulated dehydrator emissions, revealing that gas-assisted glycol pump emissions are the dominant contributors to both dehydrator-level and site-level methane emissions under uncontrolled conditions. Further analysis of the 154 dehydrator units reported by operators under the AMI 2024 project showed that 54 units (31%) used gas-driven glycol pumps, of which 6 units (11%) operated with uncontrolled flash tanks, and 22 units (40.7%) were identified as potentially oversized. Of the six dehydrator units with uncontrolled gas-assisted pumps, pump emissions accounted for 90.25% of total dehydrator emissions and 63.10% of total site-level emissions. These findings highlight substantial opportunities for emissions mitigation through equipment upgrades.

MAES↗

Efficacy of a portable, moderate-resolution, fast-scanning differential mobility analyzer for ambient aerosol size distribution measurements

Abstract. Ambient aerosol size distributions obtained with a compact scanning mobility analyzer, the “Spider” differential mobility analyzer (DMA), are compared to those obtained with a conventional mobility analyzer, with specific attention to the effect of mobility resolution on the measured size distribution parameters. The Spider is a 12 cm diameter radial differential mobility analyzer that spans the 10–500 nm size range with 30 s mobility scans. It achieves its compact size by operating at a nominal mobility resolution R=3 (sheath flow = 0.9 L min−1; aerosol flow = 0.3 L min−1) in place of the higher ratio of sheath flow to aerosol flow commonly used. The question addressed here is whether the lower resolution is sufficient to capture key characteristics of ambient aerosol size distributions. The Spider, operated at R=3 with 30 s up- and downscans, was co-located with a TSI 3081 long-column mobility analyzer, operated at R=10 with a 360 s sampling duty cycle. Ambient aerosol data were collected over 26 consecutive days of continuous operation, in Pasadena, CA. Over the 17–500 nm size range, the two instruments exhibit excellent correlation in the total particle number concentrations and geometric mean diameters, with regression slopes of 1.13 and 1.00, respectively. Our results suggest that particle sizing at a lower resolution than typically employed may be sufficient to obtain key properties of ambient size distributions, at least for these two moments of the size distribution. Moreover, it enables better counting statistics, as the wider transfer function for a given aerosol flow rate results in a higher counting rate.

54 ENVIRONMENTAL SCIENCES↗

An interlaboratory comparison of mid-infrared spectra acquisition: Instruments and procedures matter

Diffuse reflectance spectroscopy has been extensively employed to deliver timely and cost-effective predictions of a number of soil properties. However, although several soil spectral laboratories have been established worldwide, the distinct characteristics of instruments and operations still hamper further integration and interoperability across mid-infrared (MIR) soil spectral libraries. In this study, we conducted a large-scale ring trial experiment to understand the lab-to-lab variability of multiple MIR instruments. By developing a systematic evaluation of different mathematical treatments with modeling algorithms, including regular preprocessing and spectral standardization, we quantified and evaluated instruments' dissimilarity and how this impacts internal and shared model performance. We found that all instruments delivered good predictions when calibrated internally using the same instruments' characteristics and standard operating procedures by solely relying on regular spectral preprocessing that accounts for light scattering and multiplicative/additive effects, e.g., using standard normal variate (SNV). When performing model transfer from a large public library (the USDA NSSCKSSL MIR library) to secondary instruments, good performance was also achieved by regular preprocessing (e. g., SNV) if both instruments shared the same manufacturer. However, significant differences between the KSSL MIR library and contrasting ring trial instruments responses were evident and confirmed by a semi-unsupervised spectral clustering. For heavily contrasting setups, spectral standardization was necessary before transferring prediction models. Non-linear model types like Cubist and memory-based learning delivered more precise estimates because they seemed to be less sensitive to spectral variations than global partial least square regression. In summary, the results from this study can assist new laboratories in building spectroscopy capacity utilizing existing MIR spectral libraries and support the recent global efforts to make soil spectroscopy universally accessible with centralized or shared operating procedures.

58 GEOSCIENCES↗

Risk assessment of wellbore leakage during underground hydrogen storage

The expansion of renewable energy sources would require large-scale energy storage options to overcome the intermittent nature of these sources. Underground hydrogen storage (UHS) in depleted hydrocarbon reservoirs offers a scalable and practical energy storage solution. These reservoirs are chosen for their availability and large capacity, but the unique properties of hydrogen raise concerns about potential leakage pathways, particularly through wellbores. In this study, we develop and apply, for the first time, reduced-order models (ROMs) specifically designed for efficient leakage risk prediction in UHS systems operating in depleted hydrocarbon reservoirs. Using 3,000 high-fidelity simulation scenarios, we examine the influence of 11 key parameters, including reservoir and aquifer depths, wellbore permeability and porosity, initial saturations of water, oil and gas fractions (hydrogen, light, intermediate, and heavy hydrocarbons), reservoir pressure multiplier, and the aquifer-to-reservoir volume ratio, to simulate leakage behavior over a 1,000-year timescale. We train ROMs using a two-step classification-regression approach, achieving R 2 values exceeding 99 % across all targets. These ROMs effectively capture the leakage evolution and identify critical controls of leakage, guiding the design of mitigation strategies. Results indicate that gas leakage occurs in about 27 % of scenarios as early as five years post-operation, reaching volumes of up to 106 ft3. Oil leakage is less frequent (~17 %) and typically begins decades later. Our findings also show that hydrogen often migrates first, owing to its smaller molecular size and higher buoyancy, followed by heavier hydrocarbons. Over time, these heavier components contribute significantly to the total leaked volume, reinforcing the need for targeted monitoring and remediation strategies. Our analysis highlights that deeper storage reservoirs, shallower aquifers, and low-permeability wellbores significantly reduce leakage risks. In conclusion, this work offers a robust framework for risk-informed UHS deployment, supporting energy security through reliable large-scale hydrogen storage while safeguarding environmental integrity.

08 HYDROGEN↗

Online LIBS–ML Framework for Dynamic Characterization of Heterogeneous Waste-Derived Gasification Feedstocks

LIBS−ML framework for real time feedstock characterization during continuous conveyor transport Heterogeneous waste derived feedstocks (e.g., waste coal, biomass and blends) introduce rapid variability in heating value and ash chemistry that affect gasifier operation, yet conventional laboratory characterization techniques are too slow to support proactive control. To address this gap, this study reports on an online, in situ, dynamic characterization framework that couple’s laser-induced breakdown spectroscopy (LIBS) with leakage safe machine learning (ML) regression to deliver real time, decision quality predictions of gasifier relevant properties. A controlled sample matrix spanning two different waste coals, two different biomasses, and engineered blends under two particle size conditions were constructed and benchmarked using standardized laboratory analyses for proximate/ultimate properties and ash composition. LIBS spectra were acquired dynamically as material flowed on a conveyor belt, using high energy 1064 nm laser ablation and shot averaging to improve repeatability and precision. Supervised regression models (multi layer perceptron (MLP) /artificial neural network (ANN), random forest (RF), and support vector regression (SVR)) and an optimized weighted ensemble were trained on emission line feature sets using nested cross validation with Bayesian hyperparameter tuning and validated against an independent hold out set. The proposed LIBS−ML workflow achieves near laboratory predictive fidelity across parametric targets (including higher heating value (HHV), ash content, fixed carbon, sulfur, major ash forming oxides, and initial deformation temperature (IDT)), with the weighted ensemble providing a robust default predictor under dynamic measurement conditions. These results demonstrate a practical pathway for real time feedstock characterization that can enable feedforward adjustments and more resilient gasifier operation for variable quality waste derived fuels.

Biomass↗

Generation of Data-Driven Expected Energy Models for Photovoltaic Systems

Although unique expected energy models can be generated for a given photovoltaic (PV) site, a standardized model is also needed to facilitate performance comparisons across fleets. Current standardized expected energy models for PV work well with sparse data, but they have demonstrated significant over-estimations, which impacts accurate diagnoses of field operations and maintenance issues. This research addresses this issue by using machine learning to develop a data-driven expected energy model that can more accurately generate inferences for energy production of PV systems. Irradiance and system capacity information was used from 172 sites across the United States to train a series of models using Lasso linear regression. The trained models generally perform better than the commonly used expected energy model from international standard (IEC 61724-1), with the two highest performing models ranging in model complexity from a third-order polynomial with 10 parameters (Radj2 = 0.994) to a simpler, second-order polynomial with 4 parameters (Radj2=0.993), the latter of which is subject to further evaluation. Subsequently, the trained models provide a more robust basis for identifying potential energy anomalies for operations and maintenance activities as well as informing planning-related financial assessments. We conclude with directions for future research, such as using splines to improve model continuity and better capture systems with low (≤1000 kW DC) capacity.

14 SOLAR ENERGY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A data-driven operational model for traffic at the Dallas Fort Worth International Airport

Airports are on the front line of significant innovations, allowing the movement of more people and goods faster, cheaper, and with greater convenience. As air travel continues to grow, airports will face challenges in responding to increasing passenger vehicle traffic, which leads to lower operational efficiency, poor air quality, and security concerns. This paper evaluates methods for traffic demand forecasting combined with traffic microsimulation, which will allow airport operations staff to accurately predict traffic and congestion. Using two years of detailed data describing individual vehicle arrivals and departures, aircraft movements, and weather at Dallas-Fort Worth (DFW) International Airport, we evaluate multiple prediction methods including the Auto Regressive Integrated Moving Average (ARIMA) family of models, traditional machine learning models, and DeepAR, a modern recurrent neural network (RNN). We find that these algorithms are able to capture the diurnal trends in the surface traffic, and all do very well when predicting the next 30 minutes of demand. Longer forecast horizons are moderately effective, demonstrating the challenge of this problem and highlighting promising techniques as well as potential areas for improvement. Traffic demand is not the only factor that contributes to terminal congestion, because temporary changes to the road network, such as a lane closure, can make benign traffic demand highly congested. Combining a demand forecast with a traffic microsimulation framework provides a complete picture of traffic and its consequences. The result is an operational intelligence platform for exploring policy changes, as well as infrastructure expansion and disruption scenarios. To demonstrate the value of this approach, we present results from a case study at DFW Airport assessing the impact of a policy change for vehicle routing in high demand scenarios. This framework can assist airports like DFW as they tackle daily operational challenges, as well as explore the integration of emerging technology and expansion of their services into long term plans.

97 MATHEMATICS AND COMPUTING↗

Process modeling guides operational variables that affect CO 2 utilization during the accelerated carbonation of concrete

Abstract Accelerated concrete carbonation is an expanding option for decarbonizing construction. Factors such as concrete mixture design and carbonation environment can influence the maximum CO 2 utilization that can be achieved during such a process. A carbonation process designed to utilize a water‐saturated dilute CO 2 source wherein 2 < CO 2 concentration (v/v%) < 16, was modeled in AspenPlus©. A regression model was developed to correlate CO 2 uptake, relative humidity (11%–100%), CO 2 concentration ([CO 2 ] = 2—16 v/v%), and temperature ( T = 11–74°C) conditions within a carbonation reactor. It was determined that [CO 2 ] was the most significant variable as higher concentrations enhanced CO 2 transport through the concrete. The energy use intensity per mass of CO 2 utilized (kWh/kgCO 2 ) was determined across a range of processing conditions. As a function of the operational conditions, accelerated carbonation provides a net CO 2 reduction of up to 28 kgCO 2 /tonne of concrete; a reduction of up to ~45% compared to typical formulations.

Prentice, Dale P.↗

Predictive analytics of selections of russet potatoes

We explore the application of machine learning algorithms specifically to enhance the selection process of Russet potato (Solanum tuberosum L.) clones in breeding trials by predicting their suitability for advancement. This study addresses the challenge of efficiently identifying high-yield, disease-resistant, and climate-resilient potato varieties that meet processing industry standards. Leveraging manually collected data from trials in the state of Oregon, we investigate the potential of a wide variety of state-of-the-art binary classification models. The dataset includes 1086 clones, with data on 38 attributes recorded for each clone, focusing on yield, size, appearance, and frying characteristics, with several control varieties planted consistently across four Oregon regions from 2013 to 2021. We conduct a comprehensive analysis of the dataset that includes preprocessing, feature engineering, and imputation to address missing values. We focus on several key metrics such as accuracy, F1-score, and Matthews correlation coefficient (MCC) for model evaluation. The top-performing models, namely a feedforward neural network classifier (Neural Net), a histogram-based gradient boosting classifier (HGBC), and a support vector machine classifier (SVM), demonstrate consistent and significant results. To further validate our findings, we conducted a simulation study using the aims, data-generating mechanisms, estimands, methods, and performance measures (ADEMP) framework, simulating different data-generating scenarios to assess model robustness and performance through true positive, true negative, false positive, and false negative distributions, area under the receiver operating characteristic curve (AUC-ROC) and MCC. The simulation results highlight that non-linear models like SVM and HGBC consistently show higher AUC-ROC and MCC than logistic regression, thus outperforming the traditional linear model across various distributions, and emphasizing the importance of model selection and tuning in agricultural trials. Variable selection further enhances model performance and identifies influential features in predicting trial outcomes. The findings emphasize the potential of machine learning in streamlining the selection process for potato varieties, offering benefits such as increased efficiency, substantial cost savings, and judicious resource utilization. Our study contributes insights into precision agriculture and showcases the relevance of advanced technologies for informed decision-making in breeding programs.

60 APPLIED LIFE SCIENCES↗

Smart Methane Emission Detection System Development (Final Report)

Working with the Department of Energy's National Energy Technology Laboratory, Southwest Research Institute® (SwRI®) developed a system to identify methane leaks reliably, accurately, and autonomously at critical midstream sections of the natural gas distribution network in real-time for the purpose of mitigating methane emissions using Optical Gas Imaging (OGI) cameras. SwRI's Smart Leak Detection – Methane (SLED/M) adds a high degree of automation to the process of methane leak detection to minimize sources of human error, minimize response time to a leak event, and maximize midstream visibility. Furthermore, SwRI has been working towards integrating Quantitative OGI (QOGI) capabilities into this existing technology. By leveraging Deep Learning, SwRI now has the capability to estimate fugitive emission leak rates quickly and reliably, which allows operators to detect emissions, quantify leak rate, prioritize repairs, and validate the repairs in a single instrument. The next generation QOGI technology leverages the same cameras used in Leak Detection and Repair (LDAR) programs, with improvements in safety and speed for traditional quantification-based repairs, ultimately leading to less overhead cost for the operators. The goals for this research were to develop two types of models with the following goals: Run in real-time on the edge (≥ 12 Hz), Classification: Achieve less than 5% false positive detection, Classification: Achieve ≥ 95% methane plume detection rate, Regression: achieve ≤ 10 standard cubic feet per hour (scfh) prediction > 70% of the time. In order to achieve these results, multiple infrared (IR) and other sensors were investigated in tandem with the midwave IR (MWIR) OGI to provide additional information to train the underlying models. Information on atmospheric conditions including humidity, temperature, pressure, and solar radiation was provided by a weather station. Several machine learning and deep learning architectures and methods, including looking at quantized classification networks and regressions networks, were explored. As further data was collected, curated, and labeled, it allowed for more refined regressive networks to be adequately trained, leading to better insight into the true flow rates being observed. An important valuable deliverable of this research effort was the development of an advanced network which underwent multiple iterations capable of giving a continuous output. The current network has a predicted mean average percentage error (MAPE) of 12.3% just outside our target goal of 10.00%, but an accuracy of 97.78% at ±50 scfh, well within the overall goal for the Department of Energy (DOE) program. Upon closer inspection, it was observed that more than 10% of datapoints contributing to the MAPE predictions were the result of low flow rate predictions and are beyond the sensitivity of instrument measurement as a result of normal operational variation and noise.

03 NATURAL GAS↗

Determination of confinement regime boundaries via separatrix parameters on Alcator C-Mod based on a model for interchange-drift-Alfvén turbulence

The separatrix operational space (SepOS) model (Eich and Manz 2021 Nucl. Fusion 61 086017) is shown to predict the L–H transition, the L-mode density limit, and the ideal magnetohydrodynamic ballooning limit in terms of separatrix parameters for a wide range of Alcator C-Mod plasmas. The model is tested using Thomson scattering measurements across a wide range of operating conditions on C-Mod, spanning $\overline{n}_{\mathrm{e}}$ = 0.3–5.5 $\times 10^{20}\,$m −3 , $B_{\mathrm{t}} = 2.5$–8.0 T, and $B_{\mathrm{p}}$= 0.1–1.2 T. An empirical regression for the electron pressure gradient scale length, $\lambda_{{p}_{\mathrm{e}}}$, against a turbulence control parameter, $\alpha_{\mathrm{t}}$, and the poloidal fluid gyroradius, $\rho_{\mathrm{s,p}}$, is constructed for H-modes and found to require positive exponents for both regression parameters, indicating turbulence widening of near-scrape-off layer widths at high $\alpha_{\mathrm{t}}$ and an inverse scaling with $B_{\mathrm{p}}$, consistent with results on ASDEX Upgrade. The SepOS model is also tested in the unfavorable drift direction and found to apply well to all three boundaries, including the L–H transition as long as a correction to the Reynolds energy transfer term, $\alpha_\mathrm{RS} \lt 1$ is applied. I-modes typically exist in the unfavorable drift direction for values of $\alpha_{\mathrm{t}} \lesssim 0.3$. Finally, an experiment studying the transition between the Type-I ELMy and EDA H-mode is analyzed using the same framework. It is found that a recently identified boundary $\alpha_{\mathrm{t}} = 0.55$ at excludes most EDA H-modes but that the balance of wavenumbers responsible for the L-mode density limit, namely $k_\mathrm{EM} = k_\mathrm{RBM}$, may better describe the transition on C-Mod. The ensemble of boundaries validated and explored is then applied to project regime access and limit avoidance for the SPARC primary reference discharge parameters.

ELM suppression↗

Using probabilistic solar power forecasts to inform flexible ramp product procurement for the California ISO

How can independent system operators (ISOs) take advantage of probabilistic solar forecasts to lower generation costs and improve reliability of power systems? We discuss one three-step approach for doing so, focusing on how such forecasts might help the California Independent System Operator (CAISO) prepare unexpected net load ramps, where net load equals gross demand minus wind and solar production. First, we enhance an existing solar forecasting system to provide well-calibrated hours-ahead probabilistic forecasts. We then relate the degree of uncertainty reflected in the forecasted prediction intervals (independent variables) to error distributions for net load ramp forecasts for the CAISO real-time market (dependent variable) using machine learning and quantile regression. Projected ramp forecast errors conditioned on solar uncertainty are translated into flexible ramp requirements that therefore reflect real-time meteorological and solar conditions, improving on typical ISO procedures. Detailed descriptions are provided on the quantile regression and kth-nearest neighbor categorization methods for accomplishing that translation. Finally, a multiple time-scale look-ahead market simulation model is applied to a 118-bus IEEE Reliability Test System, modified to represent the CAISO generation mix and demand distributions. The model runs quantify how solar-conditioned ramp requirements can, first, decrease operating costs by reducing requirements compared to often conservative unconditional methods and, second, decrease generation scarcity events and consequently improve reliability by increasing flexibility requirements at times when unconditional forecast-based requirements understate actual ramp uncertainty. Solar-conditioned ramp requirements are found to reduce generation operating costs by about 2% for the test system (which would be equivalent to over $\$100$ million per year for a CAISO-size system).

14 SOLAR ENERGY↗

Gaussian process regression for radiological contamination mapping- Applied to optimal motion planning for mobile sensor platforms [Slides]

Want to achieve best representative characterization of the entire area efficiently and accurately-Unmanned aerial/ground vehicles (UAV/UGVs) for contamination mapping. Some major challenges include: Limited battery life (move smart), Human operated (fully autonomous controls) and Many measurements (predictive mapping capabilities). The objective: Develop fully autonomous controls for mobile sensor platforms to improve efficiency and maintain performance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cycle-by-cycle Delay Estimation at Signalized Intersections by using Machine Learning and Simulated Video Detection Data

Accurate estimation of delay is crucial for efficient traffic signal operations. Estimation of delay in the real-time manner using traditional loop detectors requires advanced detectors (in addition to stop-bar detection). In cases when this detection layout is not in place, delay estimates are approximated with a lower accuracy. Video detection is one of the most frequently deployed detection systems at signalized intersections in recent years. In most cases video detection operates in the same way as traditional inductive loops. However, when coupled with computer vision algorithms, video detection systems could be used to retrieve additional information (e.g., vehicular arrivals and departures) that cannot be taken out from the conventional systems (e.g., long stop-bar loop detectors). Although present for several decades, video detection data were not frequently examined for delay estimation purposes. In this study, we proposed a novel delay estimation model which can be developed with only data from stop-bar video detectors. Relevant data were collected from a simulation model of 11 signalized intersections at downtown Chattanooga, TN and processed to create needed inputs for model development. With the use of multigene genetic programming the authors developed a delay model that outperforms accuracy of multi regression model. Furthermore, authors evaluated the developed model by comparison with the other benchmark delay models, such as HCM and approach delay model. It was found that the developed MGGP delay model outperforms benchmark models for a wide range of traffic and signal operation conditions.

Erdagi, Ismet Goksad↗

Predicting Initial Trans-Membrane Pressure for Optimized Operations in UF Unit Using Random Forest

With the growing scarcity of freshwater, innovative process design mechanisms like Ultra-filtration(UF) units are increasingly gaining attention among water treatment utilities to address the rising demand. Ensuring reliable water production necessitates efficient resource utilization, minimizing downtime in UF systems. Recent advancements in machine learning (ML) have enabled the development of accurate data-driven models for Model Predictive Control (MPC), often requiring minimal prior knowledge of underlying physical processes. In this study, we present predictive regression models based on Random Forest (RF) and Auto-Regressive (AR) approaches to forecast the initial Trans-Membrane Pressure (TMP) for each filtration cycle in data generated by Direct Potable Reuse (DPR) systems. The proposed RF-based model demonstrates superior performance compared to baseline methods, including historical mean, Last Observation Carried Forward (LOCF), and naïve AR models, across various forecasting horizons in terms of root mean square (RMSE) metric. Accurate prediction of initial TMP is critical for optimizing CCRO operations, as it enables the development of robust modelling frameworks that enhance process efficiency and reliability. The demonstrated efficacy of the RF-based approach highlights its potential as a tool for real-time decision-making in water treatment systems, paving the way for advanced process optimization and sustainable water resource management.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Distributed Data-Driven Optimization for Voltage Regulation in Distribution Systems

Here, this paper proposes a distributed data-driven optimization framework for voltage regulation in distribution systems. The recursive kernel regression and alternating direction method of multipliers (ADMM) are selected to cover the system learning and distributed optimization tasks. The proposed distributed data-driven framework is capable of having a rapid response to system or load changes while considering the operation optimality. Besides, the distributed algorithm parallels the computation tasks and reduces the computational expense of a single agent. To validate the performance of the proposed method, a hypothetical 7-Bus system and the IEEE 123-Bus system are selected to show the effectiveness of the proposed data-driven framework. According to the numerical study results, the proposed method offers great flexibility for selecting customized kernel models for different regions and can effectively improve the system voltage profile in a distributed manner.

24 POWER TRANSMISSION AND DISTRIBUTION↗