Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Operational intent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Nitrate and Nitrite at Hanford – From Tanks to Natural Attenuation

Washington River Protection Solutions, LLC (WRPS) contracted Pacific Northwest National Laboratory (PNNL) in support of their maturation testing and analysis to develop and deploy an ambient temperature solidification/stabilization process for low-activity waste (LAW) (referred to as “grout” in this report). The intent of this effort is to support a sample-and-send regulatory and processing strategy in the Hanford 200 West Area, specifically considering grout waste forms disposal at Hanford in the Integrated Disposal Facility (IDF). Currently the disposal of grouted LAW is not an option because the IDF is not permitted to receive this waste form. The material presented in this report is intended to help inform the U.S. Department of Energy (DOE), the site operating contractors, regulatory agencies, and stakeholders of the future implications of IDF disposal of a grouted LAW waste form, specifically for the behavior of nitrate (NO 3 - ) and nitrite (NO 2 - ) at the Hanford. The only calculation of nitrate release from a hypothetical grouted LAW inventory in the IDF showed that the overall release was slightly above the compliance limit of 45 mg/L nitrate and 3.32 mg/L nitrate after 1000 years (Asmussen et al. 2019). As such, uncertainty around the impact of nitrate and nitrite release from the IDF was identified in the recent National Academies of Sciences study of Hanford supplemental LAW by both the national laboratory team and Hanford stakeholders (Bates et al. 2023). However, these calculations (and others for the IDF involving secondary waste grout) may be conservative as no nitrate and nitrite retention in the grout waste form was assumed, nor any attenuation in the subsurface. There is evidence from the literature of processes that can attenuate nitrate migration both in the waste form and in the Hanford subsurface. If found to be technically defensible and likely to occur in the IDF and associated subsurface, then these processes should be included in modeling of the IDF to represent the behavior of nitrate and nitrite more accurately. Doing so would remove unnecessary conservatism in the modeling projections and reduce the uncertainty in assessments of facility compliance of a grouted LAW waste form in the IDF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of ECCS Acceptance Criteria and Experimental Basis Evolution Toward Fuel Fragmentation, Relocation, and Dispersal Studies

The U.S. nuclear industry is pursuing extensions of light water reactor (LWR) fuel burnup and enrichment limits to approximately 75 GWd/t and 10 wt.% 235 U to achieve economic and operational benefits. A central safety consideration in this effort is the behavior of high burnup (HBu) fuel during loss-of-coolant accidents (LOCAs), particularly fuel fragmentation, relocation, and dispersal (FFRD). Here, this work provides a historical and technical review of U.S. LOCA regulation and experimentation, clarifying how the evolution of Emergency Core Cooling System (ECCS) acceptance criteria in 10 CFR 50.46 has shaped both testing approaches and interpretations of fuel safety. The study revisits the original intent of the ECCS criteria, showing that the peak cladding temperature and equivalent cladding reacted limits were developed as surrogates to preserve a coolable geometry. The explicit inclusion of the coolable geometry criterion in the regulation was intended to emphasize the underlying safety philosophy and as a safeguard against unforeseen failure modes, an intent that remains directly relevant to modern concerns regarding FFRD. The review traces the lineage of HBu LOCA experiments to the Argonne National Laboratory furnace tests, from which subsequent programs at Studsvik, Halden, and Oak Ridge National Laboratory were derived. These tests employed a 5 °C/s heating rate inherited from early embrittlement studies, a stylized temperature history that does not represent actual LWR LOCA thermal-hydraulics. Comparison of these test conditions to pressurized water reactor large break LOCAs and separate effects data indicates that the existing HBu LOCA database may not be fully applicable to all LWR LOCA scenarios, from which a qualitative framework for applicability is proposed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

Engineering in Cyber Resilience with Cyber-Informed Engineering

Engineers have super powers to provide cybersecurity resilience with deterministic engineering solutions and to protect systems from the most catastrophic consequences that a cyber saboteur could cause. Come to this session to learn how to use engineering risk management skills to harden your engineered systems from cyberattacks. Objective 1 Identify what system functions could be digitally induced to cause undesired high-impact consequences. Objective 2 Analyze how loss or instability of digital controls in a subsystem could lead to high-impact consequences. Objective 3 Analyze how loss or instability in the digital connectivity between systems could lead to high-impact consequences. Objective 4 Identify engineering controls which could build resilience by eliminating digital loss or instability pathways or reduce the impact of digital loss or instability. This presentation will introduce Cyber-Informed Engineering, described below, and walk participants through specific engineering use cases to show how engineers can consider the potential for cyber sabotage in their existing system designs and enact deterministic engineering-based controls which eliminate pathways for attack or mitigate specific consequences. A wide variety of application use cases will be considered so that audience members can align the material with familiar engineering applications. CIE is an engineering approach that integrates cyber resilience into the conception, design, build, and operation of any physical system that has digital connectivity, sensors, monitoring, or control. CIE offers the opportunity to use engineering to eliminate or mitigate avenues for cyber attack—starting from the earliest stage of design and continuing throughout the system’s lifecycle. Today, engineers and industrial control system (ICS) technicians build engineered systems with specific goals for safety, reliability, and functionality. While systems engineering includes considerable safety and failure mode analysis, cybersecurity risks are often not specifically addressed—particularly the risks of intentional cyber compromise, exploitation, and misuse. Cyber-Informed Engineering pairs well with traditional cyber defenses and offers an extra designed-in protection to eliminate the most catastrophic consequences which can be realized by an adversary should traditional cyber defenses fail.

42 ENGINEERING↗

Understanding Impacts of Data Integrity Attacks on Transactive Control Systems

With the rapid growth of internet-connected smart devices capable of exchanging energy price information and adaptively controlling energy consumption of connected loads, the role of transactive control is expected to become more prominent in the modern grid. Transactive control systems integrate the wholesale and retail energy markets, and enable active participation of end users, thereby playing a key role in managing the rising number of distributed assets in the smart grid. The use of internet for the communication of data between the controllers at the building, distribution, and transmission levels makes the system susceptible to cyber-attacks. A skilled adversary can potentially manipulate the exchanged data with the intention of inflicting damage to the system. In this paper, four categories of metrics are put forth for evaluating the performance of the system when under data integrity attacks. A model for scaling-based data integrity attack has been described, and co-simulations have been performed on a 240 bus WECC transmission system model with detailed modeling of distribution systems at specific buses. Our results show that scaling-based data integrity attacks can have non-trivial impacts on the operational, financial, and comfort aspects of the transactive control system.

Smart grid, transactive control system, Buildings-↗

LANL Meteorological Program Self-Assessment 2021 Update

This self-assessment, documented in Table 1, has shown that there has been continued significant progress achieved in meeting the intent of the 21 recommendations from the 2015 DMCC Assist Visit. Every year after the Assist Visit, the LANL Met Program has improved, mainly by addressing the recommendations in the Assist Visit report. The Met Program management should continue to strive to apply its limited resources and seek to acquire additional human capital and physical resources to meet the dynamic needs of its growing sitewide customer base. This includes additional upgrading of the hardware and software elements of the Met Program and implementation of its operational procedures and QAPP to ensure it will consistently meet important present program requirements, as well as anticipated future requirements. These improvements have been summarized in the “present improvements and future initiatives” column in Table 1.

47 OTHER INSTRUMENTATION↗

Field-dependent carrier transport in implanted isolation region of GaN lateral power devices

Among GaN lateral power devices, with proper E-field management, the breakdown occurs in the device isolation region rather than the active region. In this paper, we investigate field-dependent carrier transport in the isolation structures. Isolation test structures with variations in buffer doping, un-intentionally doped (UID) GaN thickness, and implantation conditions were fabricated. Electrical characterization was performed over a wide range of voltage and temperature. With varying UID GaN thickness and buffer doping, the leakage current and breakdown characteristics remain the same for a specific implantation condition, indicating that the leakage conduction and breakdown are governed by the implanted GaN region. Analysis of the temperature-dependent I–V reveals that carrier transport in the implanted GaN can be well explained by hopping conduction, involving three distinctive regions of operation depending on the E-field. At low E-field, carrier transport is ohmic, consistent with variable range hopping, driven by thermal activation. At medium E-field, a field enhanced thermally activated hopping is observed, following σ ∼ σ(T)exp(E). At high E-field, activation-less hopping is visible, following σ ∼ exp(−1/E), which occurs above a critical E-field limited by localization length.

Sadek, Mansura (ORCID:0000000322588338)↗

High-Efficiency Inductive Output Tubes Using a Third Harmonic Drive on the Grid

In this article, we discuss the use of a third harmonic component to the drive voltage on the grid of an inductive output tube (IOT). High-efficiency IOTs are typically characterized by efficiencies up to 70%–75%. However, the achievement of efficiencies greater than 80% would substantially reduce the operating costs of next-generation accelerators. In order to achieve this goal, we consider the addition of a third harmonic component to the drive signal on the grid of an IOT. The use of a third harmonic drive component in IOT guns has been considered in order to apply such a gun as the injector of radio frequency linear accelerators (RF linacs). Furthermore, we consider that the IOT will be used to provide the rf power to drive RF linacs and apply the third harmonic with the intention of increasing the efficiency of the RF output of the IOT. We consider a model IOT with a 700-MHz resonant cavity and using an annular beam with a voltage of 30 kV, an average current of 6.67 A yielding a perveance of about 1.3 μP. We simulate this IOT using the NEMESIS simulation code which has been successfully validated by comparison with the K5H90W-2 IOT developed by Communications and Power Industries. It is found that the effect of the third harmonic on the efficiency is greatest when the phase of the third harmonic is shifted by radians with respect to the fundamental drive signal and with third harmonic powers greater than about 50% that of the fundamental drive power. For the present example, we show that efficiencies approaching 86% are possible by this means.

43 PARTICLE ACCELERATORS↗

Cyber-physical Architecture For Automated Responses (cyphar) In Adversarial Ot Environments

The ability to react to a malicious attack starts with high fidelity recognition, and with that, an agile response to the attack. The current operational technology (OT) systems for a critical infrastructure may include an intrusion detection system (IDS), but the ability to adapt to an intrusion is a human initiated response. Orchestrators, which are coming of age in the financial sector and allow for levels of automated response, are not prevalent in the OT space. To evolve to such responses in the OT space, a tradeoff analysis is first needed, The tradeoff analysis, which evaluates the mitigation benefits of responses versus the physical affects that result, inform an automated response decision. The intent of this paper is to provide a formulation of a tradeoff analysis and its use in advancing automated, agile responses.

Rieger, CraigG.↗

Storm Water Pollution Prevention Plan Middle DP Road Recovery Effort, June 26, 2020

The United States Environmental Protection Agency (EPA) has issued a final 2017 Construction General Permit (CGP) that covers discharges of stormwater from construction sites. The 2017 National Pollutant Discharge Elimination System (NPDES) General Permit for Storm Water Discharges from Construction Activity (Appendix D) includes the following requirements:(1) conduct a critical habitat and threatened/endangered species study; (2) develop and implement a Storm Water Pollution Prevention Plan (SWPPP) in accordance with good engineering practices; (3) submit a Notice of Intent (NOI); (4) install and maintain erosion and stormwater controls; (5) perform and document storm water inspections during construction and site stabilization; (6) amend the SWPPP as necessary; and (7) submit a Notice of Termination (NOT) following project completion and final stabilization of disturbed areas. Authorization to discharge storm water is required under this Permit for both large and small construction projects disturbing more than one (1) acre or part of a larger common plan of development that collectively disturbs more than one (1) acre. All parties that meet the definition of Operator must be permitted. Each permittee is not required to develop and implement a separate SWPP Plan. It is required that there be at least one SWPP Plan for a site that incorporates the required elements for all Operators. The 2017 CGP number for New Mexico (Region 6) is NMR100000. This Plan, which has been developed for Triad National Security, LLC (Triad), describes the nature and sequencing of construction activities, potential sources of pollution, and identifies the Best Management Practices (BMPs) to minimize the potential for erosion and storm water pollution. The Plan was developed in accordance with the provisions of the Clean Water Act (33 U.S.C. § §1251 et seq., as amended by the Water Quality Act of 1987, P.L. 100-4), and the regulations established by the U.S. Environmental Protection Agency (EPA) for National Pollutant Discharge Elimination System (NPDES) General Permits for Storm Water Discharges From Construction Activities.

54 ENVIRONMENTAL SCIENCES↗

Storm Water Pollution Prevention Plan Middle DP Road Recovery Effort, June 26, 2020 (Copy for Informational Puproses Only)

The United States Environmental Protection Agency (EPA) has issued a final 2017 Construction General Permit (CGP) that covers discharges of stormwater from construction sites. The 2017 National Pollutant Discharge Elimination System (NPDES) General Permit for Storm Water Discharges from Construction Activity (Appendix D) includes the following requirements: (1) conduct a critical habitat and threatened/endangered species study; (2) develop and implement a Storm Water Pollution Prevention Plan (SWPPP) in accordance with good engineering practices; (3) submit a Notice of Intent (NOI); (4) install and maintain erosion and stormwater controls; (5) perform and document storm water inspections during construction and site stabilization; (6) amend the SWPPP as necessary; and (7) submit a Notice of Termination (NOT) following project completion and final stabilization of disturbed areas. Authorization to discharge storm water is required under this Permit for both large and small construction projects disturbing more than one (1) acre or part of a larger common plan of development that collectively disturbs more than one (1) acre. All parties that meet the definition of Operator must be permitted. Each permittee is not required to develop and implement a separate SWPP Plan. It is required that there be at least one SWPP Plan for a site that incorporates the required elements for all Operators. The 2017 CGP number for New Mexico (Region 6) is NMR100000. This Plan, which has been developed for Triad National Security, LLC (Triad), describes the nature and sequencing of construction activities, potential sources of pollution, and identifies the Best Management Practices (BMPs) to minimize the potential for erosion and storm water pollution. The Plan was developed in accordance with the provisions of the Clean Water Act (33 U.S.C. § §1251 et seq., as amended by the Water Quality Act of 1987, P.L. 100-4), and the regulations established by the U.S. Environmental Protection Agency (EPA) for National Pollutant Discharge Elimination System (NPDES) General Permits for Storm Water Discharges From Construction Activities.

54 ENVIRONMENTAL SCIENCES↗

Accuracy Enhancement of Nuclear Power Plant Simulators Utilizing High Accuracy Simulation Predictions

More recently, reactor core simulators for core designs associated with commercial nuclear power plants that utilize what is believed to be higher fidelity models have been developed. Features such as neutronics models that utilize transport equation solvers with fine spatial meshes and many energy-groups, thermal-hydraulic models that utilize sub-channel solvers with fine spatial mesh and capable of treating a wide range of fluid conditions, and fuel-coolant chemistry interaction models capable of treating CRUD deposition are to be found in these higher fidelity core simulators. These reactor core simulators require access to higher performance computers, characterized by many processors, cores and large memory. So associated with utilization of these simulators is access to high performance computers and ability to accommodate in one’s workflow longer execution times. By contrast, currently used core simulators by the nuclear industry can execute on engineering workstations and have execution times of seconds to minutes. The desirability for having short execution times is not only desired for support of time critical tasks but supports the mental process of decision making by engineers. The goal of the work reported upon here has the objective of retaining the fidelity of higher fidelity models while retaining the ability to utilize engineering workstations. Beyond the core simulator goal, additional goals of this work include incorporating the just described core simulator capability into a Nuclear Steam Supply System (NSSS) simulator, and to incorporate the resulting capability into an environment supportive of design and operational decision making associated with nuclear power stations. The model selected for the core neutronics model is the NESTLE code, for the core thermal-hydraulic model is the CTF code utilizing coarse mesh, and for the NSSS model is the RELAP5-3D code. WSC’s proprietary 3KEYMASTERTM platform is being used to provide software coupling, user interface, visualization, and reporting. The NESTLE core neutronics simulator was first integrated with the CTF core thermal-hydraulic simulator using CTF developed communication commands which are also used for CTF to communicate with RELAP5-3D under WSC’s proprietary 3KEYMASTERTM platform. To assure NESTLE prediction consistency with higher fidelity core neutronic simulators, buffer codes have been created to automatically generate from output files written by the VERA core simulator the NESTLE nodal neutronic parameter’ library, geometry, and pin-power reconstruction input files, thereby avoiding a number of challenges associated with utilizing lattice physics codes and providing consistency with VERA predictions. To treat absorber rod effects a multi-set library is utilized, where a set refers to a specific absorber rod fully inserted pattern. A coarse spatial mesh CTF model was developed with features added that support using CTF as envisioned in the engineering quality simulator. A hybrid meshing approach was implemented to allow for automated construction of models with mixed levels of refinement. Specifically, a core model could resolve some assemblies at a nodal level (4 subchannels per assembly) and others at a pin-resolution (one subchannel per coolant subchannel in the assembly). The intention is that this will allow for better resolution of limiting conditions such as DNBR and PCT, which are based on local rod and subchannel conditions. Further development was done of features that enhance the capabilities for the envisioned engineering quality simulator that has been developed, but now for RELAP-3D. The RELAP5-3D code development includes ability to model more than 999 components and the addition of the cross-channels turbulence mixing model and the void drift model that are implemented in CTF, aiming to achieve closer prediction agreement of the two codes for transient simulations, specifically, more accurate matches of the overall mass, momentum, and energy exchanges of both the liquid and gas phases between the neighboring core assemblies. Graphics were also developed for the Instructor Station for this project under WSC’s proprietary 3KEYMASTERTM platform to facilitate design and operational decision making.

42 ENGINEERING↗

Design and Development of Low Weight, Titanium Aluminide Airfoils for High Performance Industrial Gas Turbines meeting 65% Combined Cycle Efficiency (Final Report)

This project funded under DOE-FOA-0001816 was performed with the intent of evaluating the potential of utilizing a low density, high specific strength Titanium Aluminide (TiAl) alloy in a large annulus last stage gas turbine blade with the intent of improving combined cycle gas turbine efficiency toward a goal of reaching 65% efficiency. The project consisted of identifying a potentially suitable TiAl material for manufacture of such a large blade by investment casting. This included estimation of design properties for the selected alloy, trade studies using a baseline design created for a nickel based alloy cast in the TiAl alloy to evaluate potential design changes required for the use of this material and optimization of a prototype design for the same baseline application using the selected TiAl alloy. Several rounds of optimization were completed with the intent of meeting the baseline design targets with a resulting design that showed at least equivalent performance in terms of creep, LCF/TMF, HCF and aerodynamic damping potential. While it was found that significant reductions in blade loading on the disk were possible, the design resulting from the optimization met most lifing targets at the baseline size, but showed a reduction in margins in some areas in comparison to the Ni-based baseline design. Additionally, it was found that the low strain tolerance of the TiAl alloy for temperatures at and below the operational temperature of the attachment resulted in marginal, although still acceptable, creep rupture performance of the design. Due to results indicating the reduced potential for increasing turbine annulus compared to expectations a Phase II award was not proposed and it is not recommended to pursue additional design optimization efforts until further material advances with TiAl materials are achieved.

03 NATURAL GAS↗

Detection and Localization of Damaged Photovoltaic Cells and Modules Using Spread Spectrum Time Domain Reflectometry

The operating efficiency of photovoltaic (PV) plants can be improved if damaged or degraded modules can be detected and identified. Currently, string-level power electronics can detect problems with modules or cabling but not locate them, which would facilitate addressing these issues. Here, we investigate the ability of spread spectrum time domain reflectometry (SSTDR) to both detect and locate/identify damaged cells and modules within a series-connected PV string. We tested the ability of SSTDR to detect and locate single-cell mini-modules and full-sized PV modules, which were intentionally damaged by impacts with a hammer (breaking the glass and damaging the silicon below) or by cutting through some or all busbars. Damage to the glass and silicon of cells was detected and located within a small string of minimodules. Busbar damage was detectable only if an open was created by cutting through all intercell busbars. Furthermore, physical impact damage to the glass and silicon of a full-sized PV module could be detected, but further development of signal processing is needed to achieve localization of such damaged modules within a string.

14 SOLAR ENERGY↗

FORCE Regression Testing

Via programs including the Light Water Reactor Sustainability and Integrated Energy Systems, the U.S. Department of Energy has invested in the Framework for Optimization of ResourCes and Economics (FORCE) software framework (Idaho National Laboratory 2024a) for the technical and economic analysis of nuclear-integrated energy systems (IES). Nuclear IES expand the use of nuclear from traditional baseload electricity generation to a flexible and adaptive source of combined heat and power. Nuclear heat can be used in the production of a variety of energy currencies such as hydrogen and ammonia as well as other heat applications including water desalination and district heating. FORCE is designed with the intent to provide interconnected analysis tools that enable the accurate technical and economic assessment of specific nuclear IES configurations for individual energy markets. FORCE consists of three main analysis pathways: HYBRID (Idaho National Laboratory 2024b), which contains high-resolution physical models for IES; Holistic Energy Resource Optimization Network (HERON) (Idaho National Laboratory 2024c), which analyzes IES long-term economic viability; and Optimization of Real-time Capacity Allocation (ORCA) (Idaho National Laboratory 2024d), designed for real-time control of IES via digital twins and optimal decision making, including autonomous and remote operation research. Development of the FORCE ecosystem is guided by three pillars: capability, which assures that the computational requirements of IES analysis are met by the software tools; reliability, which provides for consistent code performance and expected behaviors; and accessibility, which lowers the barrier to entry for using the software and accelerates analysis by users beyond the FORCE primary developers. Reliability of the FORCE ecosystem is established according to the American Nuclear Society?s Nuclear Quality Assurance (NQA-1) program [American Society of Mechanical Engineers 1982], with specific levels of software quality assurance (SQA) within NQA-1 applied to each software tool in FORCE. As the tools within FORCE have matured, some integration algorithms to accurately connect the software tools for holistic analysis have been developed and deployed within the FORCE software repository. In accordance with NQA-1 standards, regression tests are required to guarantee the software performs consistently even when new capabilities are added to the software. In this report, we document the deployment of both unit tests, which test the consistent behavior of small pieces of the FORCE code base, as well as integration tests, which test the consistent performance of full use cases for the FORCE integration algorithms. We further document the encapsulation of these tests within a test harness, which collectively checks for each successful test completion on demand. Finally, we document the automation of the test harness using GitHub Actions [GitHub 2024], which require all tests succeed before any new capability or other changes can be added to the FORCE integration software

97 MATHEMATICS AND COMPUTING↗

Development of Low-Cost, High-Performance, Easy-To-Apply, Non-Flammable, Inorganic Phase Change Material (PCM) Technology (Project Final Report)

This report describes a 45-months long research program focused on the development of novel, easy-to-apply, non-flammable, and high-performance inorganic phase change materials (PCMs) for building and industrial applications. The University of Massachusetts Lowell (UML) formed a world-class team consisting of researchers form InsolCorp (only N. American manufacturer of inorganic PCM systems for building applications), and a group of industrial advisors, to develop a universal/multipurpose, simple-to-manufacture and cost-effective PCM technology. The project team expects that the results of this work will spur in the future the adoption of thermal storage materials – a key building energy saving technology as identified by DOE BTO – for a variety of building envelope applications. The main goal of this project was to demonstrate a suite of low-cost, multipurpose, and durable inorganic PCM formulations with phase transition temperatures encompassing typical building applications (between +5 o C and +55 o C). The first objective was to design, fabricate, and experimentally validate a performance of inexpensive, durable, highly efficient, non-flammable, and easy to manufacture PCMs. To allow a variety of building applications, the project team focused on formulations that exhibit repeatable phase transitions between +5 o C and +55 o C. To follow the DOE BTO cost efficiency target without compromising thermal performance, our work was based on inorganic compounds (mostly salt hydrates) and their blends, which represent a fraction of the cost of most of organic PCMs with about twice as high density as well as significantly higher thermal conductivity and phase change enthalpy. The second objective was to develop easy-to-manufacture and -install packaging/encapsulation designs that are 1) a superior barrier to current state-of-the-art macro-packaging, which significantly reduces the risk of loss of hydration water and PCM leak, and 2) optimal in enhancing the heat exchange rates with the surroundings and within the PCM core to ensure complete charging/discharging of the entire PCM within the product. Finally, the project’s intend was to scale-up the fabrication process to demonstrate installation on system-scale applications, and to validate the performance under field conditions. This work aimed at developing low-cost, high-energy storage, and reliable latent heat storage technology for building applications. This development was realized by formulating and integrating the following two technology components: 1) inorganic salt hydrate based PCMs that have high latent enthalpies and are low-cost and durable, and 2) PCM encapsulation (packaging) technology that maximizes PCM concentration and enhances heat transport characteristics in the product and with the external environment/materials. High thermal storage capacity, low cost and fire resistance are key to the building market entry for PCM technology. Therefore, the project’s focus was on salt-hydrate-based formulations which satisfy all these criteria. Packaging and/or encapsulation of PCM is a key processing step. The project team recognized that a low-cost and simple-to-manufacture salt hydrate-based PCM technology holds the best chance to be successful in the building construction market, a market which is traditionally extremely sensitive to cost and where commodity thermal insulations are the benchmark for envelope-related energy saving measures. That is why, in this project, the main intention was to minimize the production cost and maximize the product energy storage density without sacrificing the PCM performance. It was achieved through: 1. Minimizing the non-PCM components (plastics, additives, packaging/encapsulation materials, etc.) because they are significantly more expensive than salt hydrates, 2. Using highly thermally conductive and lightweight PCM carrier (packaging material) to facilitate more complete phase cycling, and 3. Optimizing the thickness and minimizing air spaces in product design (such as in pouched PCM). For this purpose, our approach was to enable an easy system design, including selection of the PCM operating temperatures, optimizing the necessary heat storage capacity (by stacking together several layers of PCM products), and if needed, a synchronized usage of PCM products of different temperatures. A specially designed, robust, highly thermally conducting and highly impermeable packaging (to retain salt hydrate water during phase transition cycles) was designed and tested to increase the overall system thermal performance and durability. All PCM products developed during this project were tested in both lab scale and in full scale field conditions. It is expected that, after further developments and commercialization, the developed PCM technologies may be also applied in space conditioning, energy storage technologies, and heat transfer applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Mechanical Ventilation Systems in New US Homes: What types of systems are out there and are they functioning as intended?

As the airtightness of homes improves to meet energy efficiency goals, it becomes more important for mechanical ventilation systems to help maintain a comfortable and healthy indoor air environment. ASHRAE Standard 62.2 provides national guidance for mechanical ventilation system design and installation, however adoption of those guidelines into local building codes has occurred at different rates. Once provisions for mechanical ventilation are adopted in a local code, are mechanical ventilation systems properly designed, installed, commissioned and operated according to code or above code program requirements? Is there a need for further industry and homeowner education to ensure systems function as intended? This paper presents results from field studies that include characterization of mechanical ventilation systems in over 150 new homes in CA, CO, FL, GA, IL, OR, and SC built between 2011 and 2018. In each of the study homes, airflow of local (kitchen, bathrooms) and whole-house ventilation were measured. Occupant usage of the mechanical ventilation systems were monitored for one week in each home. Installed performance is compared to inferred design intent. The paper also includes homeowner perceptions about, and interactions with, the installed mechanical ventilation systems.

Martin, Eric↗

Movement Models to Predict Low‐Altitude Flight of Soaring Birds Using Look‐Ahead Environmental Factors

Advances in fine-scale movement modeling of soaring birds can aid efforts to understand and resolve the impacts of anthropogenic activities on such birds. Soaring birds often rely on underlying terrain and low-altitude updrafts to govern their flights at rotor-swept altitudes (≤ 200 m above ground level), which puts them at risk of collision with wind turbines. We developed a data-driven Markov model at 1-s resolution that predicts the fine-scale flight behavior of golden eagles (Aquila chrysaetos) as a function of ecological covariates at the current location as well as those within an eagle's line of sight. We only considered ecological covariates that are readily available in real-time (ground elevation and wind conditions). Latent factors (age, sex, species, behavioral intent, migratory status) were intentionally left out of the model. We calibrated the model using golden eagle telemetry data collected in two different ecoregions of the United States. Given a starting location, the calibrated model simulates multiple stochastic 3D paths to produce a time-explicit and spatially explicit risk map of turbine collisions. We discovered an empirical relation between the rate of change of heading and the orographic updraft conditions within an eagle's line of sight. Our model performed most effectively when predicting predominantly-soaring flights at rotor-swept altitudes during wind conditions in which turbines are likely to be operational. The calibrated model could be used in concert with automated eagle detection and turbine curtailment technologies. Specifically, once an eagle is detected by those systems, our model could then provide accurate predictions of turbines the eagle is likely to interact with in the near term.

17 WIND ENERGY↗