Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTIC SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Recent development of plasma optical systems (invited)

The article devotes a brief description of the recent development and current status of an ongoing research of plasma optical systems based on the fundamental plasma optical idea magnetic electron isolation, equipotentialization magnetic field lines, and the axi-symmetric cylindrical electrostatic plasma lens (PL) configuration. The experimental, theoretical, and simulation investigations have been carried out over recent years collaboratively between IP NASU (Kiev), LBNL (Berkeley, USA), and HCEI RAS (Tomsk). The crossed electric and magnetic fields inherent the PL configuration that provides the attractive method for establishing a stable plasma discharge at low pressure. Using PL configuration, several high reliability plasma devices were developed. These devices are attractive for many high-tech applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post mortem results of laser-optical system packaged for use in harsh environments

In this study, the design and packaging of laser-optical system was tested to harsh environments outside lab conditions and post mortem activities will be discussed. Previously, custom mounts and bonded optical assemblies were environmentally tested to ensure their survivability. The results verified the sub-assemblies would enable the design of a laser-optical initiation system that could be fielded for use in extreme conditions. The design package, which utilized the proven opto-mechanical sub-assemblies, was then tested to the same levels as the sub-assemblies. The test regiment encompassed the harshest environments currently utilized. Temperature tests were performed ranging from a maximum of +75 degrees C to a minimum of -55 degrees C, allowing for two hour soak at each temperature set point. Vibration tests were performed to a maximum level of 15.5 grms for forty seconds in each of three critical axes. Shock tests were performed to a maximum impulse level of 5700 G's for the sub-assemblies with a 1.1 millisecond long pulse; whereas the packaged laser system maximum level reached was 3700 G's at 1.1 millisecond long pulse. The laser-optical assembly was visually inspected and functionally tested before and after each test to verify survival. As designed, the system covers were laser welded shut for hermetic seal. The only open port was the laser output for testing and verification of laser performance. No optical cables were utilized. Therefore the visual inspection of the interior was performed post mortem. Finally, the post mortem results will be discussed as will the potential of redesigns on future packaging strategies.

42 ENGINEERING↗

Optical systems for digit-serial computation

High-accuracy optical systems for implementing digit-serial computations are discussed which incorporate parallelism and carry-free addition to achieve high processing speed. Employing on-line arithmetic, parallel calculations can be performed by the concurrent execution of operations. The algorithms are shown to be problem invariant and step invariant. Architectures using optical bistable devices and optical interconnects are discussed which can implement digit-serial addition, subtraction, multiplication, and division algorithms via the present approach.

Perlee, Caroline J.↗

Effect of the Enhanced Breakdown Strength in Plasma-Filled Optical System of Electron Beam Formation

The article presents recent results of the dramatically enhanced electric breakdown strength observed in the accelerating gap of a plasma-filled optical system for the formation and focusing of a wide-aperture pulsed electron beams with currents up to 80 A and energies up to 35 keV. This system is a plasma-optical diode type device in which the acceleration and formation of the electron beam occurs in the double layer between the emissive surface of the plasma cathode (electron emitter) stabilized by a fine mesh grid and the open surface of the anode plasma. The anode plasma is created by the toroidal plasma generator of original design based on the ion source with closed drift of electrons with an anode layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A radiometric model of an earth radiation budget radiometer optical system with diffuse-specular surfaces

The Earth Radiation Budget Experiment (ERBE) is to fly on NASA's Earth Radiation Budget Satellite (ERBS) and on NOAA F and NOAA G. Large spatial scale earth energy budget data will be derived primarily from measurements made by the ERBE nonscanning instrument (ERBE-NS). A description is given of a mathematical model capable of simulating the radiometric response of any of the ERBE-NS earth viewing channels. The model uses a Monte Carlo method to accurately account for directional distributions of emission and reflection from optical surfaces which are neither strictly diffuse nor strictly specular. The model computes radiation exchange factors among optical system components, and determines the distribution in the optical system of energy from an outside source. Attention is also given to an approach for implementing the model and results obtained from the implementation.

Luther, M. R.↗

Information and resolution in electromagnetic optical systems

Quantitative analysis can play a vital role in a number of polarization-based optical systems, yet to date no definition regarding resolution in the polarization domain exists. By adopting a stochastic framework, a suitable metric is developed in this article, allowing a number of polarimetric systems to be assessed and compared. In so doing, the performance dependencies of polarization-based systems are demonstrated and fundamental trends are identified.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-aperture optical system for high-resolution imaging

Technologies pertaining to a multi-aperture optical imaging system are described herein. The multi-aperture optical system comprises an afocal optical telescope and a plurality of sub-apertures that receive light from the telescope. Each sub-aperture comprises a focusing optic that creates a full-field image onto an individual image sensor that outputs data indicative of an intensity of light received at the sensor. Image processing techniques can be used to combine the sensor outputs for spectral discrimination, to improve dynamic range or to enhance resolution of a scene.

47 OTHER INSTRUMENTATION↗

An optical systems analysis approach to image resampling

All types of image registration require some type of resampling, either during the registration or as a final step in the registration process. Thus the image(s) must be regridded into a spatially uniform, or angularly uniform, coordinate system with some pre-defined resolution. Frequently the ending resolution is not the resolution at which the data was observed with. The registration algorithm designer and end product user are presented with a multitude of possible resampling methods each of which modify the spatial frequency content of the data in some way. The purpose of this paper is threefold: (1) to show how an imaging system modifies the scene from an end to end optical systems analysis approach, (2) to develop a generalized resampling model, and (3) empirically apply the model to simulated radiometric scene data and tabulate the results. A Hanning windowed sinc interpolator method will be developed based upon the optical characterization of the system. It will be discussed in terms of the effects and limitations of sampling, aliasing, spectral leakage, and computational complexity. Simulated radiometric scene data will be used to demonstrate each of the algorithms. A high resolution scene will be "grown" using a fractal growth algorithm based on mid-point recursion techniques. The result scene data will be convolved with a point spread function representing the optical response. The resultant scene will be convolved with the detection systems response and subsampled to the desired resolution. The resultant data product will be subsequently resampled to the correct grid using the Hanning windowed sinc interpolator and the results and errors tabulated and discussed.

Lyon, Richard G.↗

Reflective optical system for a hemispherical field radiometer

The Radiation Measurement System (RAMS) is a project at NASA Ames Research Center to develop infrared radiometers for use in studying radiative transfer within the earth's atmosphere. These radiometers will use a liquid nitrogen cooled reference source and thermal stabilization of the optics. One of the radiometer designs calls for a hemispherical field of view, which has stimulated development of a new optical system. The system developed uses Winston cones, some of them in the reverse of the usual direction. This optical system has been optimized for the RAMS project needs and simulated on a computer for verification.

Davis, Paul K.↗

A Phase-Shifting Zernike Wavefront Sensor for the Palomar P3K Adaptive Optics System

A phase-shifting Zernike wavefront sensor has distinct advantages over other types of wavefront sensors. Chief among them are: 1) improved sensitivity to low-order aberrations and 2) efficient use of photons (hence reduced sensitivity to photon noise). We are in the process of deploying a phase-shifting Zernike wavefront sensor to be used with the realtime adaptive optics system for Palomar. Here we present the current state of the Zernike wavefront sensor to be integrated into the high-order adaptive optics system at Mount Palomar's Hale Telescope.

adaptive optics↗

Investigation of the effects of long duration space exposure on active optical system components

This experiment was exposed to the space environment for 6 years on the Long Duration Exposure Facility (LDEF). It investigated quantitatively the effects of the long-duration space exposure on the relevant performance parameters of a representative set of electron-optic system components, including lasers, radiation detectors, filters, modulators, windows, and other related components. It evaluated the results and implications of the measurements indicating real or suspected degradation mechanisms. This information will be used to establish guidelines for the selection and use of components for space-based, electro-optic systems.

Blue, M. D.↗

Integral image tube-optical systems for the far UV.

Description of proposed image tube optical systems for narrow-band direct photography and broad bandpass photography from spacecraft outside the atmosphere. For narrow-band photography an f/1.5 Schmidt camera with a photocathode located on the focal surface is recommended. The photoelectrons are accelerated and magnetically focused onto a phosphor/fiber optics surface, the curvature of which partially corrects for distortions of the electric field introduced by the curved photocathode. The second stage can be any other tube, electrostatically or magnetically focused, having a fiber optics faceplate butted to the first stage. For broad bandpass a spectrograph with an f/3 all-reflecting Schmidt image tube camera is recommended.

Chincarini, G.↗

Submillisecond measurements of system optical modulation functions in mosaic focal plane arrays

Measurements of system optical modulation functions (MTF, SWR) may be distorted by time-dependent environmental effects (thermal, vibration, flexure) and by electronics drift. Fast data collection may therefore be advantageous by minimizing drift time. The problem of fast data collection is accentuated when modulation data must be taken on a large number of detectors in a focal plane array. A method has been developed for the generation and storage of knife edge data from focal plane arrays, where data collection time per detector is in the submillisecond range. Once knife edge collects are completed, MTF response is found using conventional convolution techniques. SWR is obtained directly from knife edge response using a computerized simulation algorithm which bypasses use of MTF harmonics. Requirements for detector electronics speed, damping, and dynamic range are considered.

Thurlow, P. E.↗

Dual laser optical system and method for studying fluid flow

A dual laser optical system and method is disclosed for visualization of phenomena in transport substances which induce refractive index gradients such as fluid flow and pressure and temperature gradients in fluids and gases. Two images representing mutually perpendicular components of refractive index gradients may be viewed simultaneously on screen. Two lasers having wave lengths in the visible range but separated by about 1000 angstroms are utilized to provide beams which are collimated into a beam containing components of the different wave lengths. The collimated beam is passed through a test volume of the transparent substance. The collimated beam is then separated into components of the different wave lengths and focused onto a pair of knife edges arranged mutually perpendicular to produce and project images onto the screen.

Owen, R. B.↗