Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OFF-GAS SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Integrated Waste Treatment Unit (IWTU) Input Coal Analyses and Off-Gass Filter (OGF) Content Analyses

A full engineering scale Fluidized Bed Steam Reformer (FBSR) system is being used at the Idaho Nuclear Technology and Engineering Center (INTEC) to stabilize acidic Low Activity Waste (LAW) known as Sodium Bearing Waste (SBW). The INTEC facility, known as the Integrated Waste Treatment Unit (IWTU), underwent an Operational Readiness Review (ORR) and a Technology Readiness Assessment (TRA) in March 2014. The IWTU began non-radioactive simulant processing in late 2014 and by January, 2015 ; the IWTU had processed 62,000 gallons of simulant. The facility is currently in a planned outage for inspection of the equipment and will resume processing simulated waste feed before commencing to process 900,000 gallons of radioactive SBW. The SBW acidic waste will be made into a granular FBSR product (carbonate based) for disposal in the Waste Isolation Pilot Plant (WIPP). In the FBSR process calcined coal is used to create a CO2 fugacity to force the waste species to convert to carbonate species. The quality of the coal, which is a feed input, is important because the reactivity, moisture, and volatiles (C,H,N,O, and S) in the coal impact the reactions and control of the mineralizing process in the primary steam reforming vessel, the Denitration and Mineralizing Reformer (DMR). Too much moisture in the coal can require that additional coal be used. However since moisture in the coal is only a small fraction of the moisture from the fluidizing steam this can be self-correcting. If the coal reactivity or heating value is too low then the coal feed-rate needs to be adjusted to achieve the desired heat generation. Too little coal and autothermal heat generation in the DMR cannot be sustained and/or the carbon dioxide fugacity will be too low to create the desired carbonate mineral species. Too much coal and excess S and hydroxide species can form. Excess sulfur from coal that (1) is too rich in sulfur or (2) from overfeeding coal can promote wall scale and contribute to corrosion in process piping and materials, in excessive off-gas absorbent loading, and in undesired process emissions. The ash content of the coal is important as the ash adds to the DMR and other vessel products which affect the final waste product mass and composition. The amount and composition of the ash also affects the reaction kinetics. Thus ash content and composition contributes to the mass balance. In addition, sodium, potassium, calcium, sulfur, and maybe silica and alumina in the ash may contribute to wall-scale formation. Sodium, potassium, and alumina in the ash will be overwhelmed by the sodium, potassium, and alumina from the feed but the impact from the other ash components needs to be quantified. A maximum coal particle size is specified so the feed system does not plug and a minimum particle size is specified to prevent excess elutriation from the DMR to the Process Gas Filter (PGF). A vendor specification was used to procure the calcined coal for IWTU processing. While the vendor supplied a composite analysis for the 22 tons of coal (Appendix A), this study compares independent analyses of the coal performed at the Savannah River National Laboratory (SRNL) and at the National Energy Technology Laboratory (NETL). Three supersacks a were sampled at three different heights within the sack in order to determine within bag variability and between bag variability of the coal. These analyses were also compared to the vendor’s composite analyses and to the coal specification. These analyses were also compared to historic data on Bestac coal analyses that had been performed at Hazen Research Inc. (HRI) between 2004-2011.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing an Engineered Form of MOFs CaSDB and HKUST –1

Selective Kr and Xe capture to various adsorbents have been studied extensively as part of the Off-gas Sigma Team. In hopes to develop a better adsorbent, Pacific Northwest Nation Laboratory (PNNL) has suggested the use of metal-organic frameworks (MOFs). In 2016, PNNL developed compressed and ground engineered forms of calcium–4,4’–sulfonyl dibenzoate (CaSDB) MOF which was tested at Idaho National Laboratory (INL). The tests found that the CaSDB had a sufficient saturation capacity, but a low breakthrough capacity. The larger issue was that the CaSDB form was not robust enough to withstand handling necessary for installation in a column and flow system. In 2018, PNNL sent two MOFs, CaSDB and Hong Kong University of Science and Technology – 1 (HKUST–1), to INL. INL’s goal was to develop an engineered form that maintained adsorption properties comparable to the original MOFs and was robust enough to use in a column. Initial testing consisted of batch-wise contacts of the MOFs with aprotic solvents and water, to ensure there was not a dramatic degradation of the material. BET analyses confirmed that the MOFs could be exposed to water and DMSO without significant loses in surface area. MOF engineered forms were successfully produced, CaSDB–EF1 and HKUST–EF2, using the INL-patented PAN technique (USA Patent No. 8,686,083, 2013). Brunauer, Emmet and Teller (BET) analyses performed on the engineered forms yielded surface areas of 148 m 2 /g and 1487 m 2 /g for CaSDB–EF1 and HKUST–EF2 respectively, 67.6% and 83.7% of the surface areas of the respective pristine materials. Both engineered form MOFs are deemed acceptable for further study to determine efficacy for selective Kr and Xe capture.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of an Engineered Form MOF CaSDB

Under the Off-Gas Sigma Team, Idaho National Laboratory (INL) and Pacific Northwest National Laboratoory (PNNL) have been able to study various sorbents for the separation of krypton (Kr) and xenon (Xe). PNNL has researched and prepared various metal-organic frameworks (MOFs) to use for the separation. Calcium–4,4’–sulfonyl dibenzoate (CaSDB), a high surface area MOF, was synthesized and sent to INL for deep bed testing. The MOF showed an acceptable saturation capacity, but a low breakthrough capacity; However, the recieved MOF was deemed as unusable in a flow system because of its powdery nature. In 2018, PNNL sent a sample of CaSDB – MOF powder to INL with the goal to incorporate it into an engineered form that maintained adsorption properties comparable to the original MOF. It was anticipated that the engineered form of the sorbent would possess sufficient mechanical strength to be used in a column, and eliminate the dustiness of the raw material to improve handling and operability. An engineered from of CaSDB – MOF (CaSDB – EF1) was produced by incorporating the raw powder into a polyacrylonitrile (PAN) binder. The PAN binding material eliminated the dustiness of the raw MOF and provided a robust matrix that prevents damage from handling and use in a column. Xe adsorption testing of the sorbent revealed that it performs as well or better than previous CaSDB samples tested at INL, with an initial breakthrough capacity of 14.4 mmol/ kg at ambient temperature. Reducing the operating temperature to 253 K resulted in an increased breakthrough capacity of Xe.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Novel Calibration Approach for Monitoring Aerosol Hydrogen Isotopes Using Laser-Induced Breakdown Spectroscopy for Molten Salt Reactor Off-Gas Streams

Online monitoring is a key challenge for the continued development of molten salt reactor (MSR) technology. Laser-induced breakdown spectroscopy (LIBS) has previously been demonstrated to be a viable tool for monitoring aerosolized species and noble gases in real time, but the ability to discern varying isotopes in these streams has not yet been investigated for MSR applications. Tritium will form in MSRs from ternary fission and from (n,α)-reactions occurring in lithium-containing salts. This study compares three spectrometers of varying resolutions and types for measuring hydrogen isotope shifts in LIBS spectra of wetted filter paper. For each spectrometer, multivariate models were built (i.e., principal component regression, partial least squares regression, and multivariate curve resolution) to quantify the isotope ratio. The top models were then modified and corrected to apply the models to aerosol samples with varying isotope ratios. This novel calibration strategy offers an 82% reduction in volume of the calibration samples needed and is a more viable pathway for calibrating deployable LIBS systems. Lastly, this calibration model was compared with an all-aerosol trained model for monitoring hydrogen isotopes during a real-time test where the protium/deuterium ratio, along with representative salt species (i.e., lithium, sodium, and potassium) were adjusted dynamically. Results of this test validated the predictive capabilities of the transferred model and highlighted the capabilities of LIBS for real-time monitoring of MSR effluent streams.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY2020 Rotating Bed Reactor for Iodine Removal from WTP Melter Effluent to Support DFLAW Start-Up

In Performance Assessment (PA) of the Hanford Integrated Disposal Facility (IDF), 129 I is a significant contributor to the risk. The 2017 IDF PA accounted for 0.22% of the total 129 I inventory in Hanford tank waste as residing in the solidified liquid waste from the Effluent Treatment Facility (ETF). However, recent estimates suggest that higher percentages of the iodine processed at the Hanford Waste Treatment and Immobilization Plant (WTP) may be present in the liquid waste routed to the Liquid Effluent Retention Facility (LERF) for eventual treatment at the ETF. In addition, a recent integrated melter test performed at the Vitreous State Laboratory (VSL) at The Catholic University of America (CUA) showed the possibility that a significant fraction (>50%) of the total iodine in the melter feed could be present in the aqueous waste stream destined for the ETF. This stream represents a combination of the Effluent Management Facility (EMF) evaporator overhead condensate and the liquid waste from the WTP off-gas caustic scrubber. Higher levels of 129 I in this stream could affect the LERF and ETF Hazard Categorizations as well as the acceptability of the solidified ETF liquid secondary waste brine for disposal at the IDF. Accordingly, there is a need to investigate and develop potential methods and processes to mitigate this risk. Washington River Protection Solutions, LLC (WRPS) tasked Atkins and VSL to perform development and testing work to evaluate potential methods for removal of iodine species from the waste stream routed to the LERF. In particular, the testing investigated the use of an Atkins-SpinIonic™ Rotating Bed Reactor (RBR) system as a potential alternative to conventional column-based ion exchange or absorption processes. The present report provides results obtained from testing with an RBR system for the removal of iodine from simulants of the projected WTP waste stream that discharges to the LERF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantify the Extent of Physisorption on Silver Based Sorbents under VOG Conditions

US regulations govern release limits for volatile radionuclides contained in the gaseous effluents of used nuclear fuel reprocessing facilities. Of the four volatile radionuclides that are most restricted by the release limits ( 3 H, 14 C, 85 Kr, and 129 I), 129 I will require the greatest degree of abatement. Within a reprocessing facility, the vessel off-gas stream will likely contain 1%–5% of the total iodine at parts per billion (ppb) concentrations. Studies conducted by the authors have now investigated both I 2 and methyl iodide (CH 3 I) adsorption by two silver-bearing sorbents, hydrogen-reduced silver-exchanged mordenite (Ag 0 Z) and silver functionalized aerogel (AgAerogel) at a range of concentrations up to 1,000 ppb. Throughout this suite of tests, and particularly in the case of CH3I adsorption tests, there was a significant discrepancy in the amount of iodine recovered on sorbent beds compared to the amount of iodine that was believed to be delivered to the test system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Glass-bonded ceramic waste forms for immobilization of radioiodine from caustic scrubber wastes

Glass-bonded sodalite composite waste forms have been developed for the immobilization of liquid radioactive wastes resulting from off-gas treatment during aqueous reprocessing of used nuclear fuel, with a particular focus on 129I. The proposed composite waste form is comprised of aluminosilicate ceramic phases containing volatile radionuclides bonded with a glassy matrix. In this work, a suite of ten candidate low-temperature glass binders (ZnO-Bi2O3-based glasses and a Na2O-B2O3-SiO2 glass) were examined. Six glasses were mixed with caustic scrubber waste simulant previously converted into a sodalite-rich material (to provide glass fractions of 10 and 20 wt.%), uniaxially pressed into pellets, and sintered at 350 °C or 550 °C for 8 h in air. Iodine retention after heat treatment was assessed by neutron activation analysis, showing retention of 67-100 % of expected iodine. The aqueous durabilities of the resulting materials were then determined, following the ASTM C1308 standard test, showing iodine releases of 1 to 23 g m-2 after 4 d. The cumulative iodine release for the best performing system (a zinc-bismuth-borate glass binder) was <1 g m-2, and its iodine retention from processing was 67 %. The iodine releases compared favorably with other waste forms. In parallel, this best-performing composition was also consolidated via hot isostatic pressing (HIP) in a stainless-steel canister at 550 °C for 2 h under 100 MPa pressure. The HIPed sample was produced at the ~20 g scale and showed improved densification and minimal reaction with the canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Project Report (Oct 2014-Dec 2017): Zeolite Membranes for Krypton/Xenon Separation from Spent Nuclear Fuel Reprocessing Off-Gas

The overall focus of this project is to develop and understand SAPO-34 zeolitic membranes that can separate mixtures of radioisotope krypton-85 and xenon released as off-gases during used nuclear fuel recycling. The primary advantage of separating 85 Kr from Xe is to reduce the volume of radioactive waste for storage. The second advantage is the revenue generated from the sale of high-purity Xe. Zeolite membranes are attractive because of their much lower energy requirements relative to cryogenic distillation, and their high resistance to radiation degradation. We report the detailed study of silicoaluminophosphate zeolite SAPO-34 materials and membranes for this application, due to hypothesized favorable molecular sieving properties. In the 3-year Mission Support project, we developed a novel, high-performance, low-energy intensity, lower-cost zeolite membrane process for Kr/Xe separation during SNF processing; and investigated the underlying molecular adsorption and transport processes in both ‘idealized’ and ‘realistic’ operating conditions to develop reliable synthesis-structure-property relationships for such membranes. Adsorption and diffusion measurements on SAPO-34 crystals indicate their potential for use in Kr-Xe separation membranes, but also highlight competing effects of adsorption and diffusion selectivity. SAPO-34 membranes synthesized on α-alumina substrates via steam-assisted conversion seeding and hydrothermal growth are characterized in detail, with Kr permeances 26 GPU and ideal Kr/Xe selectivities >20 at 298 K after thickness reduction. Post-synthesis cation exchange shows large (>50%) increases in selectivity at ambient or slight sub-ambient conditions. In addition, we confirm that SAPO-34 membrane is stable under radiation exposure and the impact of radiation exposure on membrane performance would not be substantial. We also successfully synthesized hollow-fiber SAPO-34 membranes with the same performance levels as the disk-type and tubular membranes. This important development will allow a very compact and low-cost Kr/Xe separation system. Finally, a detailed process calculation for techno-economic analysis was performed by integrating Maxwell-Stefan model into cross-flow membrane system, in order to estimate the required number of membrane stages and the total cost.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Models to Incorporate Reaction Mechanisms into DG-OSPREY: Fixed-Bed Simulations for Organic Iodides Capture Using Ag 0 Z

As one of the most potent radioisotopes released during spent nuclear fuel reprocessing, 129 I is strictly regulated and must be removed before discharge. Organic iodides (primarily alkyl iodides with different chain lengths, i.e., CH 3 I, C 4 H 9 I, and C 12 H 25 I) comprise ~2% of the total iodine in the reprocessing off-gases and are primarily present in vessel off-gas (VOG). Reduced silver mordenite (Ag 0 Z) is predominantly considered for the removal of radioiodine; however, its capture performance and underlying interaction processes with long-chain organic iodides are not fully understood. Two major tasks were accomplished in this study. First, to improve upon the previous experimental studies where Ag 0 Z was used to capture CH 3 I, C 4 H 9 I, and C 12 H 25 I at different concentrations, we comprehensively investigated the corresponding capture mechanisms by characterizing fully loaded Ag 0 Z samples. Second, computational codes were implemented to perform fixed-bed simulations that account for transport and reaction mechanisms. Scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDX), powder X-ray diffraction (PXRD), UV-visible diffuse reflectance spectroscopy (UV-vis DRS), and thermogravimetric analysis (TGA) were conducted on Ag 0 Z samples that are saturated with I 2 , CH 3 I, C 4 H 9 I, and C 12 H 25 I), respectively. Results indicate that AgI is the predominant adsorption product regardless of the adsorbed iodine species, yet alkyl iodides with different carbon chain lengths may have different compositions of α- and γ-AgI. Synchrotron pair distribution function (PDF) measurements and TGA coupled with a Fourier transformed infrared detector (TGA FTIR) have been performed, and experimental data are currently analyzed. Results are expected to provide further insights into the adsorption mechanisms. The fixed-bed capture performance for CH 3 I was successfully simulated by solving mathematical equations that describe the underlying transport processes and adsorption reactions. The computational framework, Catalytic After Treatment System (CATS), that was originated in our research group, was used to solve the governing equations. Kinetic parameters, including the pore diffusivity and reaction rate constant were obtained by optimization techniques using data from thin-bed experiments performed at Oak Ridge National Laboratory. The performance of a deep bed predicted using the optimized parameters showed promising agreement with the experimental data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iodobutane Deep Bed Adsorption Test Report

The Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) Program Material Recovery and Waste Form Development (MRWFD) Campaign Off-gas Sigma Team has supported research and development on iodine control and iodine waste forms for the past several years. As a part of this on-going research, two deep-bed iodobutane adsorption tests have been performed with higher NO x levels. High (>1,000) iodine decontamination factors (DFs, the ratios of the inlet iodine concentrations divided by the outlet iodine concentrations, when the gas flowrate is constant) were achieved with both the silver aerogel and silver zeolite sorbents. The iodine adsorption mass transfer zone (the depth of the sorbent bed in which adsorption is occurring at any specific time) for these tests was estimated at 4 inches for both sorbents under the test conditions. Silver utilization for silver aerogel sorbent reached 41% (up to 12 g adsorbed iodine per 100 g silver aerogel sorbent), while silver utilization reached 43% (up to 6.8 g adsorbed iodine per 100 g silver zeolite sorbent). These values are generally consistent with results for prior methyl iodide adsorption tests. The results also indicate that, during iodine adsorption process, the organic iodide molecule decomposes so that the iodine can be adsorbed. Even when sorbent breakthrough is reached, the organic iodide molecule continues to decompose; and the unadsorbed iodine that passes through bed is no longer in the form of the original organic iodide; but in the form of iodine compounds that are soluble in NaOH solutions, such as HI or I 2 . This research and development has included iodine adsorption tests using a laboratory-scale test system containing segmented fixed beds of iodine adsorbents in series. Non-radioactive synthetic gas mixtures were blended from air, nitrogen, NO, NO 2 , water, and the target iodine compounds to represent dissolver off-gas (DOG) streams from used nuclear fuel aqueous reprocessing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of changes in microbial community structure during operation of an ammonia biofilter with molecular tools

Biofiltration has been used for two decades to remove odors and various volatile organic and inorganic compounds in contaminated off-gas streams. Although biofiltration is widely practiced, there have been few studies of the bacteria responsible for the removal of air contaminants in biofilters. In this study, molecular techniques were used to identify bacteria in a laboratory-scale ammonia biofilter. Both 16S rRNA and ammonia monooxygenase (amoA) genes were used to characterize the heterotrophic and ammonia-oxidizing bacteria collected from the biofilter during a 102-day experiment. The overall diversity of the heterotrophic microbial population appeared to decrease by 38% at the end of the experiment. The community structure of the heterotrophic population also shifted from predominantly members of two subdivisions of the Proteobacteria (the beta and gamma subdivisions) to members of one subdivision (the gamma subdivision). An overall decrease in the diversity of ammonia monooxygenase genes was not observed. However, a shift from groups dominated by organisms containing Nitrosomonas-like and Nitrosospira-like amoA genes to groups dominated by organisms containing only Nitrosospira-like amoA genes was observed. In addition, a new amoA gene was discovered. This new gene is the first freshwater amoA gene that is closely affiliated with Nitrosococcus oceanus and the particulate methane monooxygenase gene from the methane oxidizers belonging to the gamma subdivision of the Proteobacteria.

NASA Discipline Life Support Systems↗

Process Considerations for the Production of Hydrogen via Steam Reforming of Oxygenated Gases from Biomass Pyrolysis and Other Conversion Processes

Abstract In 2021, average CO 2 emissions was 9.7 g CO 2 /g H 2 produced, primarily based on steam methane reforming (SMR) technology that currently dominates hydrogen production. The substitution of natural gas (NG) and other fossil feedstocks in SMRs with renewable gases may be considered as an option for reducing greenhouse gas emissions. This analysis explores process impacts and constraints associated with the potential introduction of biogenic gases into SMRs. The results indicate that replacing NG in the fuel train of the SMR, followed by partial replacement of NG in the feed train may be a feasible approach. For the CO‐ and CO 2 ‐rich gas compositions assumed in this analysis the results indicate that feed train may accommodate up to 25 mole % of biogenic gases using allowances in existing designs and/or with small modifications, while maintaining similar hydrogen output. NG substitution in higher proportions require more major changes because of increased flow rates and heat exchange requirements in the system. Biogenic gases with lower CO 2 and higher calorific values are advantageous for NG substitution, and dry reforming using the CO 2 present in the feed gas can reduce steam consumption and increase process efficiency within limits where coking does not become a new constraint.

08 HYDROGEN↗

Effectiveness of purging on preventing gas emission buildup in wood pellet storage

Storage of wood pellets has resulted in deadly accidents in connection with off-gassing and self-heating. A forced ventilation system should be in place to sweep the off-gases and control the thermal conditions. In this study, multiple purging tests were conducted in a pilot scale silo to evaluate the effectiveness of a purging system and quantify the time and volume of the gas needed to sweep the off-gases. To identify the degree of mixing, residence time distribution of the tracer gas was also studied experimentally. Large deviations from plug flow suggested strong gas mixing for all superficial velocities. As the velocity increased, the system dispersion number became smaller, which indicated less degree of mixing with increased volume of the purging gas. Finally, one-dimensional modelling and numerical simulation of the off-gas concentration profile gave the best agreement with the measured gas concentration at the bottom and middle of the silo.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lab-scaled performance evaluation of novel water-lean solvents for post combustion CO 2 capture

Here, this work focuses on demonstrating the energetic performance and operational reliability in a continuous system of RTI's water-lean solvents for post-combustion CO 2 capture applications. RTI's Non-Aqueous Solvent, NAS-1A was subjected to 100 h of continuous, CO 2 capture and regeneration operation using a Lab-scale Gas Absorption System (LsGAS) while the CO 2 capture efficiency, mass balance, and total energy inputs were monitored. Throughout the test period, NAS-1A demonstrated stable operation with 90% CO 2 capture while requiring about 15% lower total energy input for solvent regeneration compared to 30 wt% monoethanolamine (MEA) solution. The use of a slipstream of CO 2 -rich solvent from the absorber sump reduced the regenerated CO 2 temperature before the gas was further cooled by the overhead condenser at the top of the desorber. The rich-split setup combined with a wash section may be an effective approach to remove water and solvent vapor from the regenerated CO 2 as well as to recover heat at the top of the desorber. NAS-1B was later developed and included a modifier component that lowers the heat of CO 2 absorption and reduces the vapor pressure of the amine component. The total energy inputs for 90% CO 2 capture with NAS-1B was found to be 25% less than that of the MEA. A gas chromatograph was used to monitor the amine concentration in the gas leaving the absorber wash section. It was found that under similar operating conditions, the presence of the modifier in NAS-1B reduces the amine in the absorber off-gas from 143 ppm in NAS-1A to 20 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reactor Facility Operational State Classification Using Gas Effluents and Radiation Measurements

Inferring the operational state of a reactor facility, using measurements from an independent in-situ monitoring system, is critical to the assessment of its compliance to agreements. We consider the problem of inferring the on/off operational state of a facility by using gas effluents and radiation measurements collected at the reactor's off-gas ventilation stack and within its surrounding area. Effluent release concentrations of three noble gases, namely, Ar-41, Cs-138, and Xe-138, are collected inside the ventilation stack and provided every four hours. Gamma spectra is recorded every second by a radiation detector located about 100 meters offset from the stack, which is affected by weather and nearby conditions. We study classifiers based on the correlation coefficient (CC) method [1] applied to individual modalities and their combinations. We implement CC classifiers using ground truth measurements collected over 2 operational cycles of High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) in year 2017.

Ramirez Aviles, Camila A.↗

On/Off State Classification of a Reactor Facility Using Gas Effluence Measurements

Inferring on/off operational state of a reactor facility using measurements from an independent monitoring system is critical to the assessment of its compliance to agreements. In this paper, we consider the problem of inferring on/off state of a reactor facility using measurements of Ar-41, Cs-138, and Xe-138 gas effluence types collected at the facility’s off-gas stack. We present classifiers based on thresholding measurements of individual effluence types, and then present fusers that combine their outputs or measurements. We present five fusers based on simple majority rule, Chow’s pattern recognition function, Fisher’s combined p-value statistic, physics-based Poisson radiation counts model, and correlation coefficient method. In addition, we also test five machine learning methods based on non-linear classifiers, which are available as R packages. Finally, our results show that: (i) these gas effluence measurements are effective in inferring on/off state of a reactor facility; for example, best fusers achieve ~97% detection at ~1% false alarm rate, and (ii) fusers that combine all effluence types based on physics-based models, correlation coefficient and Fisher’s method outperform simple majority rule, Chow’s fusers and machine learning methods, as well as when they are applied to individual and pairs of effluence types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Iodine and Water Co-adsorption on Silver-Functionalized Aerogel

The co-adsorption of iodine and water on silver-functionalized silica aerogel was evaluated using research quantities of the aerogel prepared at Pacific Northwest National Laboratory. A macro thermogravimetric analyzer was used to measure weight changes in a thin bed of the aerogel as air streams containing moisture and/or iodine flowed through the bed. The total gas flow in all tests was adjusted to achieve a velocity of 10 m/min through the bed. Initial heating of the aerogel sample to 150°C in dry air (dew point < -60°C) resulted in weight loss on the order of 1 wt %. Because subsequent phases of the tests indicated that the aerogel did not sorb water, the weight loss was speculated to be caused by volatilization of material that may have been used in the manufacture of the aerogel. Follow-on tests are recommended to ascertain if the aerogel sorbs water at low temperatures, such as 25°C—this would help to determine if a manufacturing reagent is volatilized when raising the sample to iodine sorption temperatures (i.e., 150°C). Alternatively, the off-gas released upon heating could be condensed and analyzed. In tests using humidified air streams with dew points between -60°C and +10°C, the aerogel did not adsorb water at test temperatures of either 75°C or 150°C. Because water alone was not adsorbed, tests were performed to ascertain if iodine sorption varied between cases when nearly no water was present in the gas stream and when water was present. In one experiment, the gas stream consisted of dry air (dew point < -60°C) with an iodine concentration of 50 ppmv. In the other experiment, the gas stream consisted of air with a water dew point of 0°C and an iodine concentration of 50 ppmv. The ultimate weight gain was nearly the same in both experiments and was presumed to be due entirely to adsorption of iodine. However, a reduced rate of iodine uptake is indicated when water vapor is present. The reason for this is unclear. In both cases, purging the sample with dry, iodine-free air resulted in some weight loss (~2 wt %). It is recommended that the gas phase chemistry of the iodine–water system be reviewed to ascertain if iodine species that are less reactive with silver than molecular iodine are present; this could explain the reduced sorption rates when water is present. Further evaluation of the desorption is recommended, especially to determine how raising the temperature would affect desorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Extended and Accelerated VOG Tests

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas streams of a processing plant, including ¹²⁹I. The dissolver off-gas and more dilute vessel off-gas streams (VOG) must both be targeted when mitigating ¹²⁹I environmental release because each contains some amount of iodine. Iodine-129 will likely be found as elemental iodine (I₂) and methyl iodide (CH₃I) in these off-gas streams. Reduced silver-exchanged mordenite (AgZ or Ag⁰Z) has been investigated as a potential sorbent for iodine abatement and is studied here under prototypic VOG conditions. Because of the relatively low iodine abundance and high flow rates of the VOG, total iodine concentrations are expected to be in the parts per billion range. Thus, VOG experiments need to run for extended durations at low concentrations to reach sorbent saturation. Because the sorbent will be exposed to oxidizing gas streams for extended periods of time, aging effects and sorbent degradation need to be considered when designing a sorbent-based abatement system. Three sets of experiments were performed with the aim of determining how the adsorption of iodine by AgZ is affected by differing test durations and gas compositions. The first tested the capacity of sorbent aged for 8 months under a humid air stream. The second tested differences in sorbent capacity and mass transfer zone (MTZ) length during high-concentration (1200 ppb v ) CH₃I loading in a humid nitrogen gas (N₂) stream and a humid air gas stream over 28 days. The third tested sorbent capacity and MTZ length during low concentration (< 200 ppb v ) CH₃I and I₂ loading in a humid air stream over 9 months. The results of these tests suggest that AgZ capacity drops by ~50% after 1 month of aging, by ~60% after 2 months of aging, and then does not continue to decrease significantly at up to 8 months of aging. One-month aging tests that compared N₂ and air as the gas stream diluent resulted in similar maximum loading capacities and overall loading curves, indicating that the effects of aging cannot be mitigated by avoiding air as the balance gas. The 9-month extended VOG tests did not result in clear sorbent saturation at the inlet, but it can be inferred using an assumption of a maximum capacity of 45 mg I/g AgZ. Applying this assumption, then the MTZ of CH₃I is 12.8 cm, and the MTZ of I₂ is 12.4 cm. These results are similar to previous tests. Comparisons to tests completed at Idaho National Laboratory suggest that the CH₃I MTZ may be dependent on concentration. Future work should re-evaluate the design of the VOG iodine capture system with this updated data and should seek to understand fundamental characteristics of CH₃I adsorption by AgZ, such as the effect of concentration, gas velocity, and gas composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗