An Overview of Space Nuclear Power Capabilities at Idaho National Laboratory
Slides for a talk about space nuclear capabilities in modeling and simulation at INL.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Slides for a talk about space nuclear capabilities in modeling and simulation at INL.
In this study, benchmark calculations were performed for the Quad Cities Unit 1 cycles 1–3 to validate the SCALE 6.3/Polaris–PARCS v3.4.2 code package with the ENDF/B-VII.1 AMPX 56-group library by comparing the simulated results with the measured data. The benchmark results will be used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for boiling water reactor physics analysis for key nuclear parameters such as reactivity and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS; additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results are summarized herein so that they can be used to evaluate uncertainties with other benchmark results for key nuclear parameters.
In this study, benchmark calculations were performed for Peach Bottom Unit 2 cycles 1–3 to validate the SCALE 6.3/Polaris–PARCS v3.4.2 with the ENDF/B-VII.1 AMPX 56-group library by comparing the simulated results with the measured data. The benchmark results will be used to evaluate uncertainties of the SCALE/Polaris–PARCS code package for boiling water reactor physics analysis for key nuclear parameters such as reactivity and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS and PARCS. Additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used to evaluate uncertainties with other benchmark results for key nuclear parameters.
This work develops data-driven models for onset of thermal barrier leakage in reactor coolant pumps. It incorporates uncertainty quantification to enhance the reliability and robustness of pre- dictions. Using synthetic data generated by the Generic Pressurized Water Reactor simulator, realistic degradation scenarios were simulated across lifecycle stages—beginning, middle, and end of life. Key variables, including differential pressure, flow rate, vibration, and temperatures, were analyzed using machine learning framework. The fully connected neural network models demonstrated exceptional performance, achieving R2 scores exceeding 0.99 and root mean square errors as low as around 8.23 × 10-2 gallon per minute (gpm) for the three stages of the lifecy- cle. UQ analysis further validated the model’s robustness, with narrow uncertainty bounds during steady-state operations and appropriately wider bounds during transitional phases, reflecting the physical behavior of the system. This work addresses important gaps in real-time condition moni- toring and regulatory compliance by integrating advanced condition monitoring technologies with UQ into IST programs. The ability to detect thermal barrier leakage early and quantify prediction reliability supports optimizing maintenance strategies while ensuring nuclear power plants’ safe and reliable operation.
A recovery action is defined as the action that prevents deviant conditions from producing unwanted effects. It generally indicates a kind of countermeasure performed in response to a failure of human action. The recovery actions especially play an important role in complex systems like nuclear power plants (NPPs), which consist of highly sophisticated controllers to ensure that desired performance and safety must be achieved and maintained. This is because a combination of human error and its recovery failure may be able to cause a catastrophic effect on a system. Analyzing recovery actions has been a critical part of HRA, which is a technique to evaluate human errors and provide human error probabilities (HEPs) for application in probabilistic safety assessment (PSA). If recovery actions are not adequately analyzed and applied to PSA models, the PSA results may be under-estimated or be not able to reasonably account for the failure of human actions in the context of PSA. For this reason, some regulatory documents such as ASME/ANS RA-Sb-2013 by the American Society for Mechanical Engineers and the American Nuclear Society and NUREG-1792 by U.S. Nuclear Regulatory Commission have emphasized the importance of recovery analysis within the HRA. A couple of existing HRA methods, such as the Technique for Human Error-Rate Prediction (THERP), the Cause-Based Decision Tree (CBDT), and the Korean Standard HRA (K-HRA), have respectively suggested their own approaches to the HRA recovery analysis. However, there are a couple of limitations to treating recovery actions using only the current HRA methods available. The biggest limitation is that the existing recovery analysis does not explicitly consider a variety of recovery action types and recovery sequences as they occur in actual NPPs. To handle the limitations of existing recovery analysis, this study proposes a simulation-based recovery analysis method using the Event Modeling Risk Assessment Using Linked Diagram (EMRALD) software. The EMRALD software is a dynamic simulation tool for PSA. It supports realistic and dynamic modeling of human actions as they would be performed at NPPs. It is also favorable to simultaneously model the specific moment at which an action is performed, the time it takes to perform the action, and the failure probability of that action. In this paper, a detailed methodology for modeling recovery actions in the simulation platform is proposed with a couple of examples. Then, outputs from the simulation are discussed as reviewing if this novel approach can complement the challenges of existing recovery analyses.
This study was the performance of the benchmark calculation for the Hatch Unit 1 cycles 1–3, to validate the SCALE 6.3/Polaris–PARCS v3.4.2 with the ENDF/B-VII.1 AMPX 56-group library by comparing the simulated results with the measured data. The benchmark results will be used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for boiling water reactor (BWR) physics analysis for key nuclear parameters such as reactivity and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS and PARCS, and additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties for key nuclear parameters with other BWR benchmark results.
Computational tools have a crucial role to play in accelerating the deployment of fusion as a clean, reliable, abundant, and sustainable energy source. Multiphysics, high-fidelity simulation capabilities can help model, study, and predict intricate interactions between materials performance, plasma exposure, neutron irradiation, and engineering processes. As such, they can assist in the resolution of scientific and engineering challenges underpinning design, construction, and commission of fusion power plants. To address these needs, ongoing efforts are leveraging the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework and delivering new computational tools for the fusion community. These tools inherit crucial attributes from MOOSE. They are open-source, modular, integrated with nuclear industry-standard software quality assurance processes, and enable multiphysics, multi-fidelity, fully integrated, zero- to three-dimensional, and massively parallel simulations. After a short overview of these capabilities, we will present the development of Fusion ENergy Integrated multiphys-X (FENIX), a MOOSE-based application designed to enable plasma facing component design and performance evaluation. Throughout their lifetime, plasma facing components are exposed to extreme thermal loads, repeated thermal shocks, and irradiation by plasma ions, neutral particles, and high-energy neutrons. Consequently, designing a plasma facing component with acceptable lifetime degradation is extremely challenging. FENIX aims to model the multiphysics environment in which plasma facing components evolve to accelerate their design studies. To that end, FENIX couples existing MOOSE capabilities such as heat transfer, thermomechanics, and thermal hydraulics, with tritium transport via the MOOSE-based Tritium Migration Analysis Program, Version 8 (TMAP8), with neutronics via the MOOSE-based high-fidelity neutron-photon transport and fluid dynamics code Cardinal, and finally with Particle-in-Cell plasma simulation capabilities being developed in this project. In this study, we present the current FENIX capabilities and preliminary results of its application to model the Tritium Plasma Experiment set up at Idaho National Laboratory.
This report documents the review of the hydrologic and hydraulic modeling approaches used to estimate local intense precipitation (LIP) flooding and their implementation in readily available simulation software packages. The review focused on a few representative simulation software packages because of the similarity of their underlying mathematical bases and the rainfall-runoff and hydraulic processes included. Their availability for use in estimating LIP flood hazards and for U.S. Nuclear Regulatory Commission staff review of these estimates at the nuclear power plant (NPP) site scale were also considered.
A transient benchmark based on the Transient Reactor Test Facility (TREAT) M2 Calibration experiment (M2-CAL) is under development. TREAT, at Idaho National Laboratory, is a graphite moderated air-cooled research reactor which has been used extensively for fuel material testing under extreme and accident conditions. Accurate benchmark models are a beneficial component in the operations, experimental planning, and development of TREAT. In this work, we present a transient benchmark model for the M2-CAL experiment core loading. The benchmark model incorporates the coupling between the Monte Carlo Code SERPENT and the computational fluid dynamics code OpenFOAM to capture the temperature feedback mechanism. The M2-CAL transient 2580 was simulated in this work. A pre-transient analysis was performed to determine the optimum core composition and conditions before the beginning of the transient. The analysis was validated against historic TREAT kinetic measurements and the worth of the transient rod T-2. The axial power distribution in the flux wire for the M2-CAL experiment was determined and contrasted with the experiment. The model was then used to simulate the M2-CAL transient 2580 experiment based on the reported pre-transient and transient conditions. Several transient observables were calculated and compared to the experiment. The model shows good agreement with the experimental power traces, period, and average increase of power at the power ramp (time > 7.8 s). Inverse point kinetics analysis was performed during the period of the power ramp for the model and the experiment based on that, the temperature feedback component was isolated and contrasted with the experimental feedback. (authors)
The Westinghouse Electric Company’s Advanced Passive Reactor (AP1000) is characterized by the incorporation of passive safety systems (PSSs) designed to ensure core cooling during transient events. The assessment of PSSs requires evaluation of their performance through a combination of experiments and simulations employing various thermal-hydraulic codes. In addition, detailed evaluation of PSSs for a specific reactor system transient analysis such as loss-of-coolant-accident analysis supports understanding representative integral effects test facility development and the further evolution model development and assessment process. Developing a reactor system code is a complex and time-consuming process that requires significant engineering expertise and effort. It can take several months to even years to complete in the early stages of reactor system design and analysis. However, this process can be expedited through the use of transient simulator models for similar reactor systems, which can be used for lesson learning and training purposes. This study uses the Personal Computer Transient Analyzer (PCTRAN) code. The main advantage of PCTRAN is its ease of use and ability to run faster than real time. This study presents the results obtained for a small-break loss-of-coolant accident (SBLOCA) for two breaks using the full version (licensed) of PCTRAN. The purpose of this investigation is to evaluate the overall system behavior during the postulated SBLOCA event as well as assess the capability of the PCTRAN code to reproduce the system response during transient events. The obtained results were compared with the Westinghouse NOTRUMP system code. The PCTRAN code proved to be reliable in predicting the qualitative behavior of the system in both transient cases. As for the system response, it was found that it is contingent on the activation time of the PSSs. The differences in reactor coolant system pressure between the two codes were attributed to the critical flow model and simplification of mass and energy balance. Despite PCTRAN’s limitations, it can still provide a reasonable prediction of various reactor parameters such as pressure, mass flow rate, and void fraction during a SBLOCA scenario. It is worth noting that PCTRAN currently employs a bulk approach similar to that of the Modular Accident Analysis Program (MAAP) and MELCOR codes. However, the upcoming version of PCTRAN will include an artificial intelligence–based detection and accident prevention system, as well as different models for different reactor components. Consequently, PCTRAN has the potential to be upgraded to match the system thermal-hydraulic codes of the U.S. Nuclear Regulatory Commission and become more widely used in cybersecurity to safeguard nuclear power plants from cyberattacks.
Here in this paper, we assessed the performance of a model-based approach for fault diagnosis of a nuclear power plant feedwater pump system. Physics-based models were constructed to monitor the performance of the system components. Plant data were used for the calibration of the models and subsequently in the diagnosis of abnormal events. We considered two real-time events representing scenarios of a pump fault and component performance degradation. The two events were correctly diagnosed, and the results demonstrated the high detection sensitivity of the physics-based models. Various sensor fault scenarios were simulated to show the capability of the approach to detect and uniquely identify sensor faults. Results for a scenario in which the plant operated in flexible power mode also showed that the diagnostic approach is insensitive to changes of operating conditions, which is one of the advantages of the model-based approach using physics-based models over purely data-driven approach.
Gallium nitride (GaN), a wide bandgap semiconductor, has vast potential to address two environment conditions associated with the application of electronics to nuclear power: elevated temperatures, and high levels of radiation. A process was developed at The Ohio State University (OSU) to enable fabrication of complex digital and analog electronics circuits for application to nuclear power environments such as locations near or in the reactor core or in spent nuclear fuel casks. Radio frequency (RF)-grade GaN high electron mobility transistor (HEMT) devices were fabricated as part of this process. These were fabricated as depletion mode and enhancement mode devices. They have been electrically characterized and have demonstrated the expected performance. Behavioral models (Verilog-A) were developed from these device measurements to enable electrical simulation of GaN HEMT devices and circuits using common electronics simulation tools based on Simulation Program with Integrated Circuit Emphasis (SPICE). A similar set of GaN HEMT devices is being developed to provide lower speed devices for logic and analog functions. These accomplishments position this technology for effective application to sensor interfacing, signal processing, and data communications in nuclear power plants, including operation in or near the reactor core.
Human reliability analysis (HRA) is a method for evaluating human errors in a variety of complex systems such as nuclear power plants, military systems, aircraft, and chemical plants. Most HRA methods currently used by regulatory institutes or utilities are called static HRA and are carried out by simple worksheets or simple calculators. To date, there are many unsolved or intrinsic challenges in static HRA. For example, existing static HRA does not realistically model and evaluate human actions as they would be performed at actual systems. There is no method with HRA to objectively estimate the time required for human actions despite being essential to HRA processes. In addition, many HRA methods still rely on a dataset generated prior to the 1980s, from unrelated industry experience or simply from expert judgment. Accordingly, this study attempted to research how to overcome the challenges of existing HRA via dynamic risk assessment (a.k.a., simulation-based or computation-based risk assessment) techniques. First, this study developed a dynamic HRA method, named as PRocedure-based Investigation Method of EMRALD Risk Assessment – HRA (PRIMERA-HRA). The PRIMERA-HRA mainly concentrates on providing HRA analysts with specific guidelines on how to reasonably model human actions, assign human reliability data and evaluate output of simulation within a dynamic probabilistic risk assessment tool, called as Event Modeling Risk Assessment using Linked Diagrams (EMRALD). Second, this study also developed a module for performance shaping factors (i.e., the key concept in HRA quantification) applicable to dynamic HRA, then implemented it based on PRIMERA-HRA within the EMRALD tool. Third, this study developed an HRA data collection framework to support dynamic HRA, called as Simplified Human Error Experimental Program (SHEEP). Originally, the SHEEP study aimed to support static HRA and its data collection, but recently extended the scope to the new technologies such as dynamic HRA or HRA for advanced reactors. SHEEP focuses on the use of data collected from simplified simulators to complement—but not replace—data collection studies using full-scope simulators and actual operators. To date, many experiments were conducted under the SHEEP framework. Multiple analyses, such as human performance analysis, human error analysis, task complexity analysis, learning effect analysis and time distribution analysis, were also carried out using the collected data. Then, based on the major insights, an approach to inferring full-scope data based on simplified simulator data was proposed. The PRIMERA-HRA and SHEEP research are expected to evaluate human actions more realistically than existing static HRA, provide an opportunity to collect more HRA data with reasonable cost and labor, then contribute to enhance the quality of HRA.
Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. THE CHORNOBYL ACCIDENT: 195 The Chornobyl Accident Revisited, Part III: Chernobyl Source Term Release Dynamics and Reconstruction of Events During the Active Phase, A. R. Sich; GENERAL SAFETY CONSIDERATIONS: 218 Second ANS Workshop on the Safety of Soviet-Designed Nuclear Power Plants, R. A. Bari; 234 Elements of a Nuclear Criticality Safety Program, C. M. Hopper; 243 Rickover, Excellence, and Criticality Safety Programs, R. E. Wilson; ACCIDENT ANALYSIS: 249 Transient Analysis of the PIUS Advanced Reactor Design with the TRAC-PF1/MOD2 Code, B. E. Boyack, J. L Steiner, S. C. Harmony, H. J. Stumpf, and J. F. Lime; 278 The Hierarchy-By-Interval Approach to Identifying Important Models that Need Improvement in Severe-Accident Simulation Codes, T. J. Heames, M. Khatib-Rahbar, J. E. Kelly, R. P. Jenks-Johnson, and Y.-S. Chen; 290 RELAP5/MOD3 Code Coupling Model, R. P. Martin; 299 Missiles Caused by Severe Pressurized-Water Reactor Accidents, R. Krieg; DESIGN FEATURES: 310 Validation of COMMIX with Westinghouse AP-600 PCCS Test Data, J. G. Sun, T. H. Chien, J. Ding, and W T. Sha; ENVIRONMENTAL EFFECTS: 321 Spent Nuclear Fuel Characterization for a Bounding Reference Assembly for the Receiving Basin for Off-Site Fuel, S. D. Kahook, R. L. Garrett, L. R. Canas, and M J. Beckum; OPERATING EXPERIENCES: 332 Reactor Shutdown Experience, Compiled by J. W. Cletcher; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 335 Reactor Coolant System Blowdown at Wolf Creek on September 17, 1994, J. V. Kauffman and S. L. Israel; RECENT DEVELOPMENTS: 344 Reports, Standards, and Safety Guides, D. S. Oueener; 349 Proposed Rule Changes as of June 30, 1995; ANNOUNCEMENTS: 320 Symposium on Acceptability of Risk From Radiation—Application to Manned Space Flight; 320 24th DOE/NRC Nuclear Air Cleaning and Treatment Conference; 361 Radiation Biology and Radiation Protection— Modern Developments and Tendencies in Radiation Biology; 362 1997 IEEE Sixth Conference on Human Factors and Power Plants; 354 The Authors; 360 Reviewers of Nuclear Safety, Vol. 36.
Benchmark calculations for the Watts Bar Unit 1 cycles 1–3 were performed to validate the SCALE 6.3/Polaris–PARCS v3.4.2 with the ENDF/B-VII.1 56-group library by comparing the simulated results with the measured data. The benchmark results are used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided for the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties for key nuclear parameters with other benchmark results.
During the summer and fall of 2021, several functional area drills were held that focused on exercising Consequence Management’s (CM) ability to extract and use data from RadResponder for the purpose of answering intermediate-phase questions presented as technical inject requests for information (RFI) in Sandia National Laboratories (SNL) Consequence Management Operational System (COSMOS) software. The scenario chosen was that of Northern Lights 2016 (NL16) which was a large-scale nuclear power plant (NPP) release exercise in the state of Minnesota. The NL16 data was extracted from the Radiological Assessment and Monitoring System (RAMS) event where it was created and was reformatted for implanting to a new RadResponder event. Next, the beta-version of a laboratory sample data simulator was used to generate more sample data that was injected to the event. Five “mini-drills” were devised with each prompt defined by a data-based need. For each drill, a team of assessment and NARAC scientists worked the problem using the drill prompt and the available data in RadResponder. The teams held a kickoff meeting, had several days to work the problem, and then reported their results as well as observations in a hotwash. Several areas for improvement in both the software and process were identified during the course of these drills. This report will document the process of addressing each RFI and the discovered gaps in both software capability and methodology so that they can be considered for future development and investment by the CM and NIRT programs.
The benchmark calculations were performed for Surry Unit 1 cycles 1–3 to validate the SCALE 6.3/Polaris–Purdue Advanced Reactor Core Simulator (PARCS) v3.4.2 with the ENDF/B–VII.1 56–group library by comparing the simulated results with the measured data. The benchmark results will be used to evaluate uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris, GenPMAXS, and PARCS. Additional details are provided for the input and output files produced for the benchmark calculations. The benchmark results were summarized such that they can be used in evaluating uncertainties with other benchmark results for key nuclear parameters.
This study performed the benchmark calculation for BEAVRS to validate the SCALE 6.3/Polaris–PARCS v3.4.2 code package with the ENDF/B-VII.1 56-group library, comparing the simulated results with the measured data. The benchmark results will be used in evaluating uncertainties of the SCALE/Polaris–PARCS code package for pressurized water reactor physics analysis for key nuclear parameters such as reactivity, control bank worth, temperature coefficients, and pin and assembly power peaking factors. This report details plant and fuel design specifications and input data for SCALE/Polaris as well as GenPMAXS and PARCS. Additionally, detailed information is provided for all the input and output files produced for the benchmark calculations. The benchmark results are summarized herein so that they can be used in evaluating uncertainties for key nuclear parameters with other benchmark results.