Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Noise floor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

VERNE: Revealing the Mysteries and Histories of Venus

Introduction: The three Venus missions that were recently selected for upcoming flight (VERITAS, DAVINCI+, and EnVision) will be incredibly valuable to our understanding of Venus’ history, geology, and atmosphere. However, even once completed, key gaps in our knowledge of Venus, and more generally the formation and active processes on rocky, Earth-like planets, will still persist. Remaining questions include 1) how global intrinsic magnetic fields might be maintained on rocky worlds, and how they could then go extinct, and 2) what role atmospheric sulfur chemistry plays in climates of Earth-like planets, which is an increasingly timely subject as Earth’s own atmospheric sulfur content is climbing due to human activity. These questions require in-situ observations from Venus’ cloud deck, at the altitudes at which the UV absorber exists. The Venus Environment Research and Novel Exploration (VERNE) mission will address these questions with an aerial platform that will drift around the equatorial region of the planet for 9 days. VERNE will collect data to determine the identity of the mysterious UV absorber, while also taking magnetic field measurements over the tesserae, the regions on Venus that are most likely to retain remanent crustal magnetization, in order to understand the potential role of a past intrinsically-generated global magnetic field on Venus. Mission Objectives: The two major science objectives that drive the VERNE mission are: 1) Determine the identity of the Venusian unknown ultraviolet absorber(s). First observed approximately a century ago [1], the composition of Venus’ ultraviolet (UV) absorber is one of the oldest mysteries in Venus atmospheric chemistry [2,3]. While several candidate UV absorbers (mostly sulfur species) have been proposed, no consensus has been reached on its composition and its specific interactions with the atmosphere. Determining the identity of the UV absorber will aid climate models by showing how and where incident solar energy is absorbed by the atmosphere and make progress towards understanding the chemical and energetic processes taking place above Venus’ upper cloud deck [4]. 2) Determine if Venus retains evidence of a past, internally-generated magnetic field. While Venus does not currently have an intrinsically-generated magnetic field, evidence for the existence of a past field on Venus and a timeline of its decay will fill in a more holistic picture of the evolution of Venus’ geological record and atmosphere. As the oldest geologic units on the surface, Venus’ tesserae may still have remanent crustal magnetization signatures within the rocky composition [5]. In any case, the signatures detected will provide insight into Venus’ past geological and core dynamo activity. Mission Summary: VERNE includes a 3-part flight system made up of 1) an entry system with a HEEET (Heatshield for Extreme Entry Environment Technology) aeroshell, 2) an orbiter for data relay, and 3) an in-situ balloon and gondola. After entry into Venus’ atmosphere, the balloon will be deployed within the upper cloud deck, at an altitude of 62 km, over a tesserae region. The in-situ data collection will last for the duration of 2 full circumnavigations of the planet, which will take ~9 days. Instrumentation Suite: The four instruments that comprise VERNE’s instrument payload will enable the identification of the unknown UV absorber and the detection of remanent crustal magnetization if it exists in the tesserae. The proposed instrument suite cycle during mission operations is shown in Fig. 1. The four instruments are described below: 1) Adams (ion neutral mass spectrometer) has a range of 18-257 AMU and will detect and distinguish the mixing ratios of O₂, H₂O, H₂SO₄, S, S₂, S₃, S₄, S₅, S₆, S₇, S₈, SO, SO₂, OSSO, SO₃, Cl₂, FeCl₃ and other trace sulfur and organic species. The spatial (longitudinal) and temporal (day/night) variations will be observed throughout 2 circumnavigations with a sample cadence of 12 minutes. 2) Shelley (nephelometer) will determine the size distribution of the aerosols (0.4 to 36 um) in the atmosphere. With a size resolution of <0.7 um, it can determine which mode of H2SO4 is present and characterize the large (>30 um) organic particles previously detected by the Venera and Galileo missions [6,7]. 3) Herbert (UV imager) will measure UV radiance at 283 nm (the wavelength of SO2 absorption) and 365 nm (the unknown part of the absorber). UV images will be taken concurrently with the INMS and nephelometer to correlate UV absorption with abundances of the UV absorber species. 4) Vonnegut (magnetometer) has a range of >600 nT and a precision and accuracy of 1 nT. If magnetized by a past field, the crust may have retained a magnetization of up to 3 A/m2 [5]. With a noise floor of 10 nT, the magnetometer will be able to detect RCM from an altitude of 62 km, even if the thickness of the magnetized crust is just 1 km (Fig. 2). Mission Concept Design: VERNE will be launched with a mass of 3300 kg in an intermediate-high performance class vehicle with a 4-m fairing. The 475-day mission includes 466 days for the cruise, coasting, and orbit initialization phases before entry, descent, and balloon deployment. During the 9-day science phase, the aerial platform will make 2 circumnavigations of the planet at an altitude of 62 km. The INMS and the nephelometer will acquire data for 2 hours during the daytime and nighttime during each circumnavigation, while the UV imager will be on for the duration of the daytime, and the magnetometer will be operational throughout the entirety of the science phase. Data will be stored and processed with the JPL-designed Sphinx command and data handling system. Data will be sent from the balloon to the orbiter using an S-band relay link, stored on the orbiter, and then forwarded to Earth where it will be received by the DSN. Conclusion: VERNE will fill key gaps in our understanding of the history and ongoing processes related to the geology and atmosphere of Venus and rocky worlds in general. Even with adequate flight system contingencies and expected costs below the $900M New Frontiers cost cap, VERNE is not without its risks and challenges. Further trade spaces to explore include 1) using solely battery power vs. including solar panels to increase the mission duration and 2) investigating the use of lightweight materials and 3D-printed structures to reduce the gondola mass, among others. Acknowledgments: We would like to thank the JPL Planetary Science Summer School, especially our mentors Troy Hudson, Karl Mitchell, and Leslie Lowes, as well as our Team-X study lead Al Nash and the members of Team-X. We’d additionally like to thank our review panel for asking insightful questions and providing valuable feedback. References: [1] Ross, F. E. (1928) Astrophysical J., 68, 57-92. [2] Rossow, W. B. et al. (1980) J. Geophysical Research, 85, 8107-8128. [3] Pinto, J. P. et al. (2021) Nature Communications, 12, 175. [4] Titov, D. V. et al. (2007) Cosmic Research, 21, 401. [5] O’Rourke, J. et al. (2019) Geophysical Research Lett., 46, 5768–5777. [6] Limaye, S. S. et al. (2018) Astrobiology, 18(9), 1181-1198. [7] Grinspoon, D. H. et al. (2013) Planetary and Space Sci., 41(7), 515-542. [8] Parker, R. L. (2003) J. Geophysical Research, 108, 5006. *The cost information contained in this document is of a budgetary and planning nature and is intended for informational purposes only. It does not constitute a commitment on the part of JPL and/or Caltech.

H Alpert↗

Test Section Characterization of the 9- by 15-Foot Low Speed Wind Tunnel

Following completion of the 9- by 15-Foot Low Speed Wind Tunnel acoustic improvement modification project, a characterization of the flow field throughout the 9- by 15-foot test section was conducted in 2019. The acoustic improvement modifications project included several large-scale tunnel loop modifications and reconstruction of the 9- by 15-Foot Low Speed Wind Tunnel test section and diffuser to decrease the noise floor in the test section. Data were collected at three cross-sectional planes in the 9- by 15-ft test section using a 15-foot traversing calibration rake and a set of eight boundary layer rakes. The data from the characterization test were used to generate calibration relationships for facility operation and understand the flow quality in the new test section, including uniformity, flow angularity, turbulence intensity, and boundary layer characteristics. Additionally, the subsonic quick check rake was used to baseline the check calibration data set for the new test section.

Calibration↗

The Laser Interferometer Space Antenna (LISA): Current plans and prospects for quantum sensing in future space-based gravitational wave observatories

ESA’s third large class mission is a space-based gravitational wave observatory with NASA as a partner. This talk will describe the current plans for this mission, including the expected science, the instrument design, and a schedule for the development and launch. The noise floor of the system will be described and opportunities for improvement, including possible applications os quantum sensing and measurement techniques.

Jeff Livas↗

Final Report for Grant

This is the final report for this project. The major objectives were to develop full models and standard cells of CMOS silicon photomultipliers (SiPM) for neutron detection applications. Specifically, the research seeks to replace photomultiplier tubes, used in neutron detection applications, with SiPMs containing integrated readout electronics fabricated in standard CMOS processes. The detectors improve on the detection efficiency, readout speed, resolution (sensitivity), and spatial resolution of current systems. In particular, this work involved collaboration with the instrument and detector group at ORNL who build detectors based on discrete commercially available PMTs and SiPMs. The SiPM detectors developed in this work are based on Perimeter Gated Single Photon Avalanche Diodes (PGSPAD). These devices have tunable breakdown voltage which affects other performance characteristics of the detectors. The ability of the detectors to have integrated readout and tune the noise floor and dynamic range in addition to offering a method for non-uniformity compensation in a compact form significantly impacts the imaging research field and includes the nuclear sciences field, circuits and systems field in addition to varied fields such as geography and biology/medicine.

42 ENGINEERING↗

Test of Harmonic Coil Accuracy Using a Multi Vertex Probe

Magnets are integral components of particle accelerators, with different multipoles used to perform various beam conditioning functions, like steering and focusing. Testing accelerator magnets to ensure compliance with specification is a crucial step of fabrication. One of the most popular techniques for verifying magnetic field strength and integrity is the harmonic coil probe. Harmonic coil probes are comprised of passive loops that are rotated around the aperture of a magnet and are used to measure magnetic flux. Oftentimes the measurements of the harmonic coil probe are affected by transverse vibrations along the axis of rotation and torsional vibrations of the position closure sensor, both causing spurious harmonics. To make matters challenging, it is difficult to distinguish between the real harmonics of the magnet and the spurious harmonics during analysis. This research explores the use of a novel configuration of harmonic coil probe, Multi-Vertex Probe (MVP), to address multiple factors that affect the accuracy and repeatability of harmonic coil probe measurement. Most of the results are based on simulation data, in which artificial torsional distortions are introduced and removed with the proposed processing method. In addition to implementing torsional vibration removal in simulation, laboratory analysis regarding the source of vibrations was performed using a pre-fabricated MVP. More specifically, various mechanical conditions were used to explore the standard deviation of main harmonic’s flux amplitude. The conditions included: coupling type (rigid or soft), rotation speed, probe starting position within magnetic field, and cabling location inside the magnetic field. Along with this, the MVP’s measured noise floor in and outside a magnetic field was quantified.

Lofquist, Claire [Northern Illinois U.]↗

High resolution atomic force microscopy with an active piezoelectric microcantilever

Active microcantilevers with on-chip sensing and actuation provide significant advantages in tapping mode Atomic Force Microscopy (AFM). Collocated transduction allows for effective manipulation of cantilever dynamics through feedback control, enabling higher scan rates. However, the adjacency of the sensing and actuation electrodes is known to result in a high level of feedthrough, leading to a low imaging resolution. Readout circuit noise further deteriorates the imaging precision. Here, we investigate the noise sources that affect AFM microcantilevers with collocated aluminum nitride (AlN) actuator–sensor pairs. We reported these cantilevers in earlier work and demonstrated that they display a very low level of feedthrough between the actuation and sensing electrodes. We present a high signal-to-noise ratio (SNR) sensing method that enables us to demonstrate high-resolution AFM on a calibration grating with nm-step silicon carbide (SiC) terraces. In conclusion, measuring the Lorentzian response of the cantilever’s Brownian motion with the on-chip active sensor at resonance enables us to calibrate the dynamic stiffness at the first fundamental resonance mode, without utilizing an optical sensor.

47 OTHER INSTRUMENTATION↗

On the Alleviation of Background Noise for the High-Lift Common Research Model Aeroacoustic Test

Microphone array measurements of the airframe noise from the High-Lift Common Research Model (CRM-HL) in the NASA Langley 14- by 22- Foot Subsonic Tunnel were initially hindered by extraneous noise sources. The steps taken to reduce the background noise in the open-jet test section for the aeroacoustic test are described in this paper. Adhesive-backed felt was used to attenuate noise resulting from the interaction of the test section shear layer with the collector and diffuser surfaces, scrubbing noise from the floor perforated panels, as well as an extraneous noise source produced near the junction of the model and the floor when the model was producing significant lift. The effects of the felt on noise attenuation and acoustic reflections are discussed. Following the CRM-HL test, scrubbing noise measurements from a floor basket with a perforated top panel were acquired in the Quiet Flow Facility to compare the performance of different perforated panel covers and their respective effects on the noise spectra. Aside from a smooth, hard wall, the felt cover was found to produce the minimum scrubbing noise of all the materials tested.

background noise↗

Analytical prediction of the interior noise for cylindrical models of aircraft fuselages for prescribed exterior noise fields. Phase 2: Models for sidewall trim, stiffened structures and cabin acoustics with floor partition

An airplane interior noise prediction model is developed to determine the important parameters associated with sound transmission into the interiors of airplanes, and to identify apropriate noise control methods. Models for stiffened structures, and cabin acoustics with floor partition are developed. Validation studies are undertaken using three test articles: a ring stringer stiffened cylinder, an unstiffened cylinder with floor partition, and ring stringer stiffened cylinder with floor partition and sidewall trim. The noise reductions of the three test articles are computed using the heoretical models and compared to measured values. A statistical analysis of the comparison data indicates that there is no bias in the predictions although a substantial random error exists so that a discrepancy of more than five or six dB can be expected for about one out of three predictions.

Pope, L. D.↗

Sensing depths in frequency domain thermoreflectance

In this work, a method is developed to calculate the length into a sample to which a Frequency Domain Thermoreflectance (FDTR) measurement is sensitive. Sensing depth and sensing radius are defined as limiting cases for the spherically spreading FDTR measurement. A finite element model for FDTR measurements is developed in COMSOL multiphysics and used to calculate sensing depth and sensing radius for silicon and silicon dioxide samples for a variety of frequencies and laser spot sizes. The model is compared to experimental FDTR measurements. Design recommendations for sample thickness are made for experiments where semi-infinite sample depth is desirable. For measurements using a metal transducer layer, the recommended sample thickness is three thermal penetration depths, as calculated from the lowest measurement frequency.

36 MATERIALS SCIENCE↗

A cryogenic torsion balance using a liquid-cryogen free, ultra-low vibration cryostat

We describe a liquid-cryogen free cryostat with ultra-low vibration levels, which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. Here, the torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency range of 3–10 mHz, limited by residual seismic motion and by radiative heating of the pendulum body. In addition to lowering thermal noise below room-temperature limits, the low-temperature environment enables novel torsion balance experiments. Currently, the maximum duration of a continuous measurement run is limited by accumulation of cryogenic surface contamination on the optical elements inside the cryostat.

47 OTHER INSTRUMENTATION↗

Photonic circuits for laser stabilization with integrated ultra-high Q and Brillouin laser resonators

The integration of stabilized lasers, sources that generate spectrally pure light, will provide compact, low-cost solutions for applications including quantum information sciences, precision navigation and timing, metrology, and high-capacity fiber communications. We report a significant advancement in this field, demonstrating stabilization of an integrated waveguide Brillouin laser to an integrated waveguide reference cavity, where both resonators are fabricated using the same CMOS-compatible integration platform. We demonstrate reduction of the free running Brillouin laser linewidth to a 292 Hz integral linewidth and carrier stabilization to a 4.9 × 10 –13 fractional frequency at 8 ms reaching the cavity-intrinsic thermorefractive noise limit for frequencies down to 80 Hz. We achieve this level of performance using a pair of 56.4 x 10 6 quality factor Si 3 N 4 waveguide ring-resonators that reduce the high-frequency noise by the nonlinear Brillouin process and the low-frequency noise by Pound–Drever–Hall locking to the ultra-low loss resonator. These results represent an important step toward integrated stabilized lasers with reduced sensitivity to environmental disturbances for atomic, molecular, and optical physics (AMO), quantum information processing and sensing, and other precision scientific, sensing, and communications applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗

A novel method may reveal bulk metallic glass compressive ductility trends in high data rate nanoindentation

Recent methods allow novel amorphous alloy compositions to be rapidly manufactured at small scale; however, obtaining materials properties such as compressive ductility from these smaller specimens has remained a challenge. Here, we suggest a potential high-throughput nanoindentation method that may be able to rapidly characterize the relative compressive ductility between these alloys based on their serration characteristics. The properties of emergent serrations, when interpreted in a simple micromechanical stress relaxation model, may order these materials by their compressive plastic strain to failure. These results are consistent with the ordering obtained from compressed specimens as well as with model simulations, suggesting that this model may be broadly useful for interpreting compressive ductility from nanoindentation serrations. After it is validated on more materials, this new method will match the rapid pace of amorphous alloy development, thus allowing metallic glass properties to be fine-tuned for each application prior to scale prototyping.

36 MATERIALS SCIENCE↗

On-target uniformity of the OMEGA 60-beam inertial confinement fusion laser

Successful direct-drive inertial confinement fusion (ICF) experiments require excellent on-target laser 9 irradiance uniformity maintained over the duration of the pulse. Achieving this symmetry relies on maintaining an 10 energy, power, and fluence balance among all beams in a multibeam laser system. As a result of the improvements 11 described in this paper, the OMEGA 60-beam laser performance has been assessed at approximately 2% on-target 12 irradiance nonuniformity using an updated performance assessment metric that accounts for the laser diagnostic noise 13 floor. The performance is measurement-limited, prompting the need for an improved diagnostic suite. This manuscript 14 provides a comprehensive first-order assessment of extant status of on-target energy, power, and fluence uniformity 15 and explores avenues for improvements.

Diagnostics↗

A method for using a time interval counter to measure frequency stability

It is shown how a commercial time interval counter can be used to measure the relative stability of two signals that are offset in frequency and mixed down to a beat note of about 1 Hz. To avoid the dead-time problem, the counter is set up to read the time interval between each beat note upcrossing and the next pulse of a 10 Hz reference pulse train. The actual upcrossing times are recovered by a simple algorithm whose outputs can be used for computing residuals and Allan variance. A noise floor-test yielded a delta f/f Allan deviation of 1.3 times 10 to the minus 9th power/tau relative to the beat frequency.

Greenhall, C. A.↗

A method for using a time interval counter to measure frequency stability

It is shown how a commercial time interval counter can be used to measure the relative stability of two signals that are offset in frequency and mixed down to a beat note of about 1 Hz. To avoid the dead-time problem, the counter is set up to read the time interval between each beat note upcrossing and the next pulse of a 10 Hz reference pulse train. The actual upcrossing times are recovered by a simple algorithm whose outputs can be used for computing residuals and Allan variance. A noise floor-test yielded a delta f-f Allan deviation of 1.3 times 10 to the minus 9th power/tau relative to the beat frequency.

Greenhall, Charles A.↗

Aircraft interior noise models - Sidewall trim, stiffened structures, and cabin acoustics with floor partition

As part of the continuing development of an aircraft interior noise prediction model, in which a discrete modal representation and power flow analysis are used, theoretical results are considered for inclusion of sidewall trim, stiffened structures, and cabin acoustics with floor partition. For validation purposes, predictions of the noise reductions for three test articles (a bare ring-stringer stiffened cylinder, an unstiffened cylinder with floor and insulation, and a ring-stringer stiffened cylinder with floor and sidewall trim) are compared with measurements.

Pope, L. D.↗

Concorde noise-induced building vibrations, Sully Plantation - Report no. 2, Chantilly, Virginia

Noise-induced building vibrations associated with Concorde operations were studied. The approach is to record the levels of induced vibrations and associated indoor/outdoor noise levels in selected homes, historic and other buildings near Dulles International Airport. Representative data are presented which were recorded at Sully Plantation, Chantilly, Virginia during the periods of May 20 through May 28, 1976, and June 14 through June 17, 1976. Recorded data provide relationships between the vibration levels of windows, walls, floors, and the noise associated with Concorde operations, other aircraft, and nonaircraft events. The results presented are drawn from the combined May-June data base which is considerably larger than the May data base covered. The levels of window, wall and floor vibratory response resulting from Concorde operations are higher than the vibratory levels associated with conventional aircraft. Furthermore, the vibratory responses of the windows are considerably higher than those of the walls and floors. The window response is higher for aircraft than recorded nonaircraft events and exhibits a linear response relationship with the overall sound pressure level. For a given sound pressure level, the Concorde may cause more vibration than a conventional aircraft due to spectral or other differences. However, the responses associated with Concorde appear to be much more dependent upon sound pressure level than spectral or other characteristics of the noise.

Source record↗