Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NiPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

152 records · Page 9

Tape-Drop Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

Composite parts of nonuniform thickness can be fabricated by in-situ automated tape placement (ATP) if the tape can be started and stopped at interior points of the part instead of always at its edges. This technique is termed start/stop-on-the-part, or, alternatively, tape-add/tape-drop. The resulting thermal transients need to be managed in order to achieve net shape and maintain uniform interlaminar weld strength and crystallinity. Starting-on-the-part has been treated previously. This paper continues the study with a thermal analysis of stopping-on-the-part. The thermal source is switched off when the trailing end of the tape enters the nip region of the laydown/consolidation head. The thermal transient is determined by a Fourier-Laplace transform solution of the two-dimensional, time-dependent thermal transport equation. This solution requires that the Peclet number Pe (the dimensionless ratio of inertial to diffusive heat transport) be independent of time and much greater than 1. Plotted isotherms show that the trailing tape-end cools more rapidly than the downstream portions of tape. This cooling can weaken the bond near the tape end; however the length of the affected region is found to be less than 2 mm. To achieve net shape, the consolidation head must continue to move after cut-off until the temperature on the weld interface decreases to the glass transition temperature. The time and elapsed distance for this condition to occur are computed for the Langley ATP robot applying PEEK/carbon fiber composite tape and for two upgrades in robot performance. The elapsed distance after cut-off ranges from about 1 mm for the present robot to about 1 cm for the second upgrade.

Costen, Robert C.↗

Valiant 'Zero-Valent' Effort Restores Contaminated Grounds

Dense non-aqueous phase liquids (DNAPLs) are chemical compounds that can contaminate soil and groundwater to the point of irreparability. These substances are only slightly soluble in water, and are much denser than water. Because of their solubility, DNAPLs form separate liquid phases in groundwater, and because of their density, DNAPLs sink in aquifers instead of floating at the water table, making it extremely difficult to detect their presence. If left untreated in the ground, they can taint fresh water sources. Common DNAPLs include chlorinated hydrocarbon compounds such as carbon tetrachloride, chloroform, tetrachloroethylene, and trichloroethylene. Trichloroethylene was used during the early days of the Space Program, as a solvent for flushing rocket engines, and for metal cleaning and degreasing of equipment, electronics, and heavy machinery. As a result, areas of Cape Canaveral s Launch Complex 34, the site of several historic Saturn rocket launches occurring from 1959 to 1968, were polluted with chlorinated DNAPLs. Through the direction and guidance of Dr. Jacqueline Quinn, an environmental engineer in the Spaceport Engineering and Technology Directorate at NASA s Kennedy Space Center, a biodegradable environmental cleanup technology was developed to reductively dechlorinate DNAPL sources in polluted water at Launch Complex 34. It was important for Kennedy to nip this problem in the bud, in light of the fact that the Space Center is also a National Wildlife Refuge, home to thousands of shorebirds, endangered sea turtles and eagles, manatees, alligators, and diverse habitats that include brackish marshes and salt water estuaries. The success in remediating this historic launch site has led to numerous commercial applications that are restoring the health of our environmental surroundings.

Source record↗

Unitary plate electrode

The unitary electrode (10) comprises a porous sheet (12) of fiberglass the strands (14) of which contain a coating (16) of conductive tin oxide. The lower portion of the sheet contains a layer (18) of resin and the upper layer (20) contains lead dioxide forming a positive active electrode on an electrolyte-impervious layer. The strands (14) form a continuous conduction path through both layers (16, 18). Tin oxide is prevented from reduction by coating the surface of the plate facing the negative electrode with a conductive, impervious layer resistant to reduction such as a thin film (130) of lead or graphite filled resin adhered to the plate with a layer (31) of conductive adhesive. The plate (10) can be formed by casting a molten resin from kettle (60) onto a sheet of glass wool (56) overlying a sheet of lead foil and then applying positive active paste from hopper (64) into the upper layer (68). The plate can also be formed by passing an assembly of a sheet ( 80) of resin, a sheet (86) of sintered glass and a sheet (90) of lead between the nip (92) of heated rollers (93, 95) and then filling lead oxide into the pores (116) of the upper layer (118).

Rowlette, John J.↗

Battery plate containing filler with conductive coating

The plate (10) comprises a matrix or binder resin phase (12) in which is dispersed particulate, conductive tin oxide such as tin oxide coated glass fibers (14). A monopolar plate (11) is prepared by coating a layer (18) of electrolytically active material onto a surface of the plate (10). Tin oxide is prevented from reduction by coating a surface of the plate (10) with a conductive, impervious layer resistant to reduction such as a thin film (22) of lead adhered to the plate with a layer (21) of conductive adhesive. The plate (10) can be formed by casting a molten dispersion from mixer (36) onto a sheet (30) of lead foil or by passing an assembly of a sheet (41) of resin, a sheet (43) of fiberglass and a sheet (45) of lead between the nip of heated rollers (48, 50).

Rowlette, John J.↗

Battery plate containing filler with conductive coating

The plate (10) comprises a matrix or binder resin phase (12) in which is dispersed particulate, conductive tin oxide such as tin oxide coated glass fibers (14). A monopolar plate (11) is prepared by coating a layer (18) of electrolytically active material onto a surface of the plate (10). Tin oxide is prevented from reduction by coating a surface of the plate (10) with a conductive, impervious layer resistant to reduction such as a thin film (22) of lead adhered to the plate with a layer (21) of conductive adhesive. The plate (10) can be formed by casting a molten dispersion from mixer (36) onto a sheet (30) of lead foil or by passing an assembly of a sheet (41) of resin, a sheet (43) of fiberglass and a sheet (45) of lead between the nip of heated rollers (48, 50).

Rowlette, John J.↗

Influence of Calcium Concentration on Permeability Changes in Flow-paths Altered by Highly Alkaline Groundwater - 17129

Groundwater around the geological repository of HLW is altered to the highly alkaline and Ca-rich condition by the constituents leaching from cementitious materials. Under such condition, the formation of CSH will affect the migration of radionuclides with the change in the hydraulic and chemical properties of the fracture (micro flow-path) in the host rock. In particular, the clogging effect with the deposition of CSH in the flow path the may contribute the retardation of radionuclide migration. In this study, the influence of Ca concentration on such clogging effect in the micro flow-path under the highly alkaline condition was examined by estimating the permeability changes with the deposition of CSH. In the experiment, the micro fractures in host rock were simulated by the micro flow-cell nipping the Teflon sheet (80 μm of thickness) between a granite chip and Teflon basement. The flow experiment was conducted by continuously injecting Ca solution to the micro flow-cell with constant flow rate. The concentrations of Ca ions for the injection solution were set in the range from 0 to 7.5 mM, and the value of pH was 12.5. As a result, under all conditions of Ca concentrations, the permeability in the flow path decreased to the range of 1. 10{sup -10} to 2.0x10{sup -10} m{sup 2} with the deposition of CSH. Besides, such decreased permeability was almost constant with increasing and decreasing periodically. Such increase and decrease in the permeability will be caused by the deposition and outflow of CSH formed in the flow path. In other words, because CSH is stable in pH higher than at least 10, under the condition with no man-made outlet such as real underground around the repository of radioactive waste, most CSH might clog through the flow-paths in the spatial range where pH exceeds at least 10, contributing the retardation effect of the migration of radionuclides released from the repository. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influences of temperature on permeability changes of flow-paths altered by highly alkaline Ca-rich groundwater - 15192

Fractures (or cracks) in host rock around the geological repository are considered as main flow-paths for the migration of radionuclides. Such fractures would be altered by the alkaline components (Ca, Na, K) leaching from cementitious materials for the construction of the repository. While silicate minerals in fractures are dissolved by highly alkaline groundwater, secondary minerals would deposit on the surface of fractures because of the reaction between the alkaline components and silicate species. The authors' previous study showed the generation of CSH-gel and the clogging of micro flow-path under the condition of Ca-rich and high pH by flow experiments. The present study examined the permeability changes with temperature in micro flow-path flowing highly alkaline Ca-rich solution, considering temperature at the depth of geological disposal system. For the simulation of micro flow-path such as fractures, 'micro flow-cell', which nipped a thin Teflon sheet with a slit between granite chip and Teflon basement, were used for the experiments. Highly alkaline Ca-rich solution (pH>12 and 8.5 mM Ca(OH){sub 2}) were injected into micro flow-cell with 2.0 ml/h of flow rate under the given temperature conditions (278 K, 296 K or 313 K). As a result, the permeability became lower with the increase in temperature. In addition, the deposition rates of CSH-gel became larger with the increase in temperature, and the activation energy was estimated to be 32.0 kJ/mol. These results suggest that flow-paths around the geological repository would undergo the clogging with CSH-gel in a shorter time-period under a condition of higher temperature. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Diagnosing implosion velocity and ablator dynamics at NIF (u)

An enhanced understanding of the unique physics probed in a burning NIP capsule is important for both nuclear weapons physics and thermonuclear ignition. In this talk we introduce a new diagnostic idea, designed to measure dynamic aspects of the capsule implosion that are not currently accessible. The current set of diagnostics for the NIF experiments includes reaction history (a time resolved measure of the d + t burn), neutron time-of-flight and spectrometry and spatial imaging of the neutron production and scattering. Although valuable, this abbreviated set of diagnostics cannot determine key dynamical properties of the implosion, such as implosion velocity (v{sub impl}) and ablator thickness. To surpass the present limits of {approx} 10{sup 15} d+t reactions, it will be necessary to increase significantly the implosion energy delivered to the DT fuel by finely tuning the balance between the remaining (imploding) ablator mass and velocity. If too much mass remains, the implosion velocity will be too slow, and the subsecpwnt PdV work will not be sufficient to overcome cooling via conduction and radiation. If too little mass remains, hydrodynamic instabilities will occur, resulting in unpredictable and degraded performance. Detailed calculations suggest the ablator must reach an implosion velocity of 3-4 x 10{sup 7} cm/sec and an areal density of {rho}{Delta}R {approx}200 mg/cm{sup 2} in order to achieve ignition. The authors present a new scheme to measure these important quantities using neutron reactions on the ablator material. During the burn, the ablator is moving relative to the 14.1 MeV d+t neutrons that are traversing the capsule. The resulting neutron-ablator Doppler shift causes a few unique nuclear reactions to become sensitive detectors of the ablator velocity at peak burn time. The 'point-design' capsule at the NIF will be based on a {sup 9}Be ablator, and the {sup 9}Be(n,p){sup 9}Li reaction has an energy threshold of 14.2 MeV, making it the ideal probe. As discussed in detail below, differences in the ablalor velocity lead to significant differences in the rate of {sup 9}Li production. We present techniques for measuring this {sup 9}Li implosion velocity diagnostic at the NIF . The same experimental techniques measuring neutron reactions on the ablator material, will allow us to determine other important dynamical quantities, such as the areal density ({rho}{Delta}R) and approximate thickness ({Delta}R) of the ablator at peak burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗