Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron generators.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Global characterization of a laser-generated neutron source

Laser-driven neutron sources are routinely produced by the interaction of laser-accelerated protons with a converter. They present complementary characteristics to those of conventional accelerator-based neutron sources (e.g. short pulse durations, enabling novel applications like radiography). We present here results from an experiment aimed at performing a global characterization of the neutrons produced using the Titan laser at the Jupiter Laser Facility (Livermore, USA), where protons were accelerated from 23 $\mathrm {\mu }$ m thick plastic targets and directed onto a LiF converter to produce neutrons. For this purpose, several diagnostics were used to measure these neutron emissions, such as CR-39, activation foils, time-of-flight detectors and direct measurement of $^7{\rm Be}$ residual activity in the LiF converters. The use of these different, independently operating diagnostics enables comparison of the various measurements performed to provide a robust characterization. These measurements led to a neutron yield of $2.0\times 10^{9}$ neutrons per shot with a modest angular dependence, close to that simulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy

Several compact proton accelerator systems for use in proton therapy have recently been proposed. Of paramount importance to the development of such an accelerator system is the maximum kinetic energy of protons, immediately prior to entry into the patient, that must be reached by the treatment system. The commonly used value for the maximum kinetic energy required for a medical proton accelerator is 250 MeV, but it has not been demonstrated that this energy is indeed necessary to treat all or most patients eligible for proton therapy. This article quantifies the maximum kinetic energy of protons, immediately prior to entry into the patient, necessary to treat a given percentage of patients with rotational proton therapy, and examines the impact of this energy threshold on the cost and feasibility of a compact, gantry-mounted proton accelerator treatment system. One hundred randomized treatment plans from patients treated with IMRT were analyzed. The maximum radiological pathlength from the surface of the patient to the distal edge of the treatment volume was obtained for 180 deg. continuous arc proton therapy and for 180 deg. split arc proton therapy (two 90 degree sign arcs) using CT profiles from the Pinnacle (Philips Medical Systems, Madison, WI) treatment planning system. In each case, the maximum kinetic energy of protons, immediately prior to entry into the patient, that would be necessary to treat the patient was calculated using proton range tables for various media. In addition, Monte Carlo simulations were performed to quantify neutron production in a water phantom representing a patient as a function of the maximum proton kinetic energy achievable by a proton treatment system. Protons with a kinetic energy of 240 MeV, immediately prior to entry into the patient, were needed to treat 100% of patients in this study. However, it was shown that 90% of patients could be treated at 198 MeV, and 95% of patients could be treated at 207 MeV. Decreasing the proton kinetic energy from 250 to 200 MeV decreases the total neutron energy fluence produced by stopping a monoenergetic pencil beam in a water phantom by a factor of 2.3. It is possible to significantly lower the requirements on the maximum kinetic energy of a compact proton accelerator if the ability to treat a small percentage of patients with rotational therapy is sacrificed. This decrease in maximum kinetic energy, along with the corresponding decrease in neutron production, could lower the cost and ease the engineering constraints on a compact proton accelerator treatment facility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of the LiCaAlF 6 :Eu Scintillator Family for Next-Generation Neutron Detection (Annual Report)

LiCaAlF 6 :Eu (LiCAF:Eu) is a promising scintillator that possesses several fundamental advantages over CsLiYCl 6 :Ce (CLYC). This scintillator, however, is just one member of a much broader family of materials known as colquiriites, designated as LiMe II Me III F 6 , where Me II and Me III can be any number of divalent and trivalent cations, respectively. The LiCAF system has incredible potential for a wide variety of substitutions in the Me II and Me III sites, and its members are recognized as excellent hosts for luminescing activator dopants (e.g., Ce 3+ , Eu 2+ , Cr 3+ , Pb 2+ and Yb 2+ ) in order to tune the nuclear and luminescence performance in several ways. We intend to fully exploit this versatility by investigating the effects of substituting other alkali, alkali-earth, rare-earth, Group III, and Group XIII elements. The objective of this work is to explore the colquiriite system of scintillating materials, most notably LiCaAlF 6 :Eu, to identify and characterize new scintillators with improved scintillation performance, simplified crystal growth, and tunable neutron and gamma sensitivities.

Harrison, Mark J.↗

Primary Hazard Screening Neutron Generator Monitor Laboratory

The description and notes describe and scope the activities performed under this PHS. All hazards have been identified. Questions are answered correctly and, as necessary, rationale or clarification is provided. All hazards in the HA have been analyzed, including the identification of controls for each hazard. l have performed the above reviews and concur that those items are complete and accurate.

99 GENERAL AND MISCELLANEOUS↗

Initial Assessment for a Generic Horizontal Fissile Solution Vessel with an Electron Beam-based Neutron Generator

The LANL NA-23 program office has provided an extensive design study for a medical isotope (i.e. Molybdenum-99) production facility based on a fissile solution vessel with various accelerator technologies. These concept designs and associated R&D have provided affordable pathways for system optimization for industry counter partner such as SHINE and Global Medial Isotope Supply (GMIS). A horizontal fissile solution vessel design with an electron beam (E-beam) accelerator is proposed and studied with modeling capabilities developed for previous concepts (i.e. a generic vertical fissile solution vessel with a deuterium-tritium (DT) accelerator). An initial system assessment is performed by estimating theoretical Molybdenum-99 production yield with MCNP6.2. A baseline system configuration is constructed based on early design discussions between LANL and GMIS. Since only an initial design concept is available at this stage, all associated system design parameters can be adjusted to fit the best system performance characteristics. In this work, unlike previous vertical system studies, the cooling configuration of the horizontal fissile solution vessel is not considered, and only fission reactions are used to quantify the theoretical product yield. Five parametric design studies are proposed, preliminary results are briefly reported, and extended design studies beyond what is proposed here are also discussed. It is concluded that a comprehensive system analysis via multiphysics coupled calculation developed by LANL should be further conducted for the final design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design Optimization of A generic Fissile Solution for Mo99 production using Electron Beam-based Neutron Generator using MCNP+CFD

Molybdenum-99 ( 99 Mo) is a medical isotope used in 80% of all medical imaging procedures today. However, 99 Mo is not directly administered to patients for imaging; its decay product, technetium-99m ( 99 mTc), is a metastable isotope with a half-life of ~6 hours. Such a short half-life does not allow for production, separation, and application to a patient before decaying further. Therefore, the solution is to produce the precursor to 99 mTc, 99 Mo. 99 Mo has a half-life of 66 hours, long enough to produce the material and send it to the desired location before it fully decays. Under National Nuclear Security Administration’s (NNSA) highly enriched uranium (HEU) minimization mission, the Material Management and Minimization (M3) office leads the Molybdenum-99 (Mo-99) program. A major goal of the Mo-99 program is to develop methods of producing 99 Mo using low enriched uranium (LEU) opposed to the traditionally used HEU domestically in the U.S. Internationally, LEU is the new standard for use in research reactors and isotope production facility. In this study, we introduce a generic fissile solution system for 99 Mo production facility meeting the design requirement of 1) LEU usage as fissile material and 2) subcritical fissile system coupled with a horizontal electron beam (E-beam) accelerator. The focus of this research is to optimize a fissile solution configuration for maximum 99 Mo production yield using MCNP model, and ultimately implement the optimized design with computational fluid dynamics (CFD) model to understand thermal hydraulic behavior and solution convection characteristic. The report consists of two parts: 1) isotope yield calculation and criticality analysis with a wide range of parametric test matrix, and 2) thermal hydraulic analysis for solution mixing and cooling assessment.

60 APPLIED LIFE SCIENCES↗

NEXT GENERATION NEUTRON SCINTILLATORS BASED ON SEMICONDUCTOR NANOSTRUCTURES

The results reported here successfully demonstrate the technical feasibility of ZnS QDs/{sup 6}LiF/polymer composites as thermal neutron scintillators. PartTec has obtained stable ZnS QDs with a quantum yield of 17% induced by UV light, and light pulse decay lifetimes of 10-30 ns induced by both UV and neutrons. These lifetime values are much shorter than those of commercial ZnS microparticle and {sup 6}Li-glass scintillators. Clear pulse height peaks induced by neutron irradiation were seen for PartTec's ZnS nanocomposites. By adjusting the concentrations, particle size and degree of dispersion of ZnS QD/{sup 6}LiF in a PVA matrix, the light absorption and light yield of films at 420-440 nm can be optimized. PartTec's novel scintillators will replace traditional {sup 6}Li-glass and ZnS/{sup 6}LiF:Ag scintillators if the PL quantum yield can be improved above 30%, and/or increase the transparency of present nanoscintillators. Time and resources inhibited PartTec's total success in Phase I. For example, bulk doping preparations of ZnS QDs with Ag{sup +}, Eu{sup 3+} or Ce{sup 3+} QDs was impractical given those constraints, nor did they permit PartTec to measure systematically the change of PL decay lifetimes in different samples. PartTec will pursue these studies in the current proposal, as well as develop a better capping and dopant along with developing brighter and faster ZnS QD scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗