Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Decay spectroscopy in the neutron-rich Mo–Ru–Pd region

A leading challenge of nuclear-structure research is to understand the properties of nuclides of extreme isospin. Experiments at radioactive-ion-beam facilities, such as the Facility for Rare Isotope Beams in the US, may answer key questions that address diverse topics including fundamental nuclear physics, stellar nucleosynthesis and nuclear applications. The neutron-rich Mo–Ru–Pd (Z = 42 – 46) nuclides are hypothesised to exhibit triaxial-oblate deformation. We performed an experiment with the Facility for Rare Isotope Beams Decay Station initiator (FDSi) to study the structure and decay properties of nuclides in this region. Over 100 different nuclides have been identified in a preliminary analysis of the data. This work presents a first look at several examples between Rb (Z = 37) and Ag (Z = 47). Performance of the FDSi and methods developed to measure ground-state and excited-state lifetimes are presented, and plans for future work are also discussed.

Allmond, James [ORNL] (ORCID:0000000165338721)↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A field-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt γ-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium γ-ray detector. Fine spatial resolution neutron and α detectors enable precise mapping of characteristic γ-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus significantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

Bucher, Brian [Idaho National Laboratory (INL)]↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Anomalous neutron nuclear-magnetic interference spectroscopy

The electron–phonon interaction plays a critical role in materials’ electrical, thermal, optical, and superconducting properties. However, measuring the phonon mode-resolved electron–phonon interaction has been challenging. Here we propose neutron-scattering-based Anomalous Neutron nUclear-Magnetic Interference Spectroscopy (ANUBIS), where the co-existence of neutron nuclear scattering and magnetic scattering leads to anomalous dynamical structure factor under the presence of the electron–phonon interaction. Such anomalous structure factor is linear in electron–phonon coupling constant at the phonon wavevector, and is directly proportional to the momentum and energy-resolved dielectric function. The experimental configuration can be achieved using existing polarized inelastic neutron scattering setup, and an order-of-magnitude estimate shows the viability to observe the anomalous scattering signal is around to 10 –4 to 10 –3 relative to phonon scattering, which is examined through the preliminary experiments and achievable at emerging neutron facilities. As a result, our proposal offers an alternative neutron-based metrology to probe the crucial electronic properties.

Electron-phonon interactions↗

The scientific case for concurrent neutron and X-ray scattering and spectroscopy

The interrogation of materials with X-rays or neutrons to determine structure, energetics, and dynamics is fundamental to advancing physical and chemical materials science and enabling innovative material technologies. A persistent challenge in materials development is that progress depends on understanding structure and dynamics across multiple length and time scales in increasingly complex, multicomponent systems featuring interfaces, heterogeneity, and hierarchical organization. Despite rapidly growing demands on materials characterization, current experimental approaches are almost exclusively based on isolated X-ray or neutron scattering and spectroscopy, reflecting a paradigm largely unchanged for decades. To assess the scientific need for a new experimental paradigm, a 3-day workshop sponsored by the U.S. National Science Foundation (NSF) was held at the SpringHill Suites, San Jose, California, from June 2 to 4, 2022. The workshop brought together 70 national and international experts who critically evaluated opportunities enabled by concurrent neutron and X-ray (NeX) scattering, spectroscopy, and imaging experiments. The participants reached a clear consensus that establishing NeX capabilities is crucial for advancing the science of complex materials in the United States. This report illustrates the scientific drivers for NeX experiments through representative examples spanning biomaterials, energy materials, soft matter, nanomaterials, quantum materials, geoscience, and applied materials research. The complementarity of neutrons and X-rays is essential for robust model development and refinement, particularly in multiphase and multicomponent systems. While joint refinement of data from separate experiments is valuable, concurrent measurements uniquely eliminate uncertainties arising from sample evolution, environmental drift, and irreproducibility associated with experiments performed at different locations and times. Realizing NeX capabilities will require the development of new instrumentation, data analysis frameworks, and robust sample environments compatible with both neutron and X-ray probes. Addressing these challenges will enable unambiguous interpretation of complex materials behavior and open new frontiers in materials research.

X-ray↗

National Diagnostic Working Group (NDWG) for inertial confinement fusion (ICF)/high-energy density (HED) science: The whole exceeds the sum of its parts

The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. Here, an abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.

47 OTHER INSTRUMENTATION↗

SEEMS: A Single Event Effects and Muon Spectroscopy facility at the Spallation Neutron Source

This study outlines a concept that would leverage the existing proton accelerator at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory to enable transformative science via one world-class facility serving two missions: Single Event Effects (SEE) and Muon Spectroscopy (μSR). The μSR portion would deliver the world’s highest flux and highest resolution pulsed muon beams for material characterization purposes, with precision and capabilities well beyond comparable facilities. The SEE capabilities deliver neutron, proton, and muon beams for aerospace industries that are facing an impending challenge to certify equipment for safe and reliable behavior under bombardment from atmospheric radiation originating from cosmic and solar rays. With negligible impact on the primary neutron scattering mission of the SNS, the proposed facility will have enormous benefits for both science and industry. Herein, we have designated this facility “SEEMS.”

47 OTHER INSTRUMENTATION↗

Validating first-principles phonon lifetimes via inelastic neutron scattering

Phonon lifetimes are a key component of quasiparticle theories of transport; yet first-principles lifetimes are rarely directly compared with inelastic neutron scattering (INS) results. Existing comparisons show discrepancies even at temperatures where perturbation theory is expected to be reliable. In this paper, we demonstrate that the reciprocal space voxel (q voxel), which is the finite region in reciprocal space required in INS data analysis, must be explicitly accounted for within theory in order to draw a meaningful comparison. Here, we demonstrate accurate predictions of peak widths of the scattering function when accounting for the q voxel in CaF 2 and ThO 2 . Passing this test implies high fidelity of the phonon interactions and the approximations used to compute the Green's function, serving as a critical benchmark of theory and indicating that other material properties should be accurately predicted, which we demonstrate for thermal conductivity.

36 MATERIALS SCIENCE↗

Building Neutron Scattering Infrastructure in Louisiana for Advanced Materials (Final Report)

The main objective of the Louisiana Consortium for Neutron Scattering (LaCNS) is to build a major neutron scattering infrastructure capable of treating both soft and hard materials. The goal is to create a sustainable effort having the quality, breadth, and depth necessary to produce competitive proposals including collaborative and center type proposals. Our scientific aim is to understand the role of coupling in emergent complex materials and its impact on the structure/property relationship and to explore how to tune the key couplings to guide the design of materials with the desired properties. This naturally includes building a base of users of the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR) in Louisiana; to train highly talented graduate and post-doctoral students in synthesis, neutron scattering, and simulation and modeling techniques, thereby helping to produce the next generation of scientist who use neutron scattering techniques as a crucial part of their research. The goal of our hard matter program is to understand the interplay between spin, charge, orbital, and lattice degrees of freedom in carefully selected complex materials. We have made considerable progress on number of complex systems including the oxide Sr3(Ru1-xMnx)2O7 where short-range magnetic ordering with anisotropic spin texture is initiated at the metal-insulator transition that clearly indicates a strong spin-charge coupling. Another critical area is in quantum materials. For example, in the topological semimetal BaMnSb2, we found a 3D canted antiferromagnetic Weyl semimetal with a 2D electronic structure and a nontrivial Berry phase. In addition, in the hexagonal chiral Mn1/3NbS2 system, we found soliton/soliton and soliton/antisoliton domain walls where the application of small fields or small currents can be used to control nanoscopic magnetic domains where the control of domain walls is crucially important for information storage. In addition, chemical transformation investigations were performed on the VISION instrument at Spallation Neutron Source (SNS). The soft matter effort was focused on understanding the role of non-covalent interactions on the structure and dynamics of fluid-based soft matter. One key focus was on sequence-defined (SD) amphiphilic peptoid polymers that allow encoding of molecular interactions and thereby systematic investigations of how charge directs the solution self-assembly of amphiphilic polymers in water. Another important area was on the dynamics of lipids self-assembled into membranes for exploring the permeability and mechanical using both neutron spin echo (NSE) spectroscopy and quasielastic neutron scattering (QENS) to distinguished between viscoelasticity and permeability at the molecular scale. Overall, the LaCNS project was quite successful, generating 145 publications and 245 presentations. Our graduate and post-doctoral students were well trained resulting in positions in national laboratories (Oak Ridge National Laboratory (ORNL), Argonne National Laboratory and Los Alamos National Laboratory), major research universities, and industry. We also developed a uniaxial pressure cell along with ORNL for SNS. A critical goal of this project was to establish a foundation for competing nationally in federally funded research programs. To this end, we were quite successful in generating over twenty-two federally and non-federally funded grants including awards from NSF, DOE, and DOD, and two early career awards. Equally important, we were able to secure a key major piece of instrumentation via a large ARO grant for a state-of-the-art electron microscope.

36 MATERIALS SCIENCE↗

Analysis of SPND Material Candidates for Real-Time Neutron Spectrum Monitoring Poster

The future of the nuclear industry will be shaped by advanced reactor designs requiring innovative instrumentation for safe operation. A key area of innovation is the ability to accurately and reliably monitor the neutron energy spectrum during operations, which would also enhance the experimental capabilities of existing research reactors. To address this need, our research focuses on the potential use of Self-Powered Neutron Detectors (SPNDs) for real-time neutron spectrum monitoring. We investigated various candidate materials for SPNDs by evaluating their energy-dependent reaction rates. Promising materials were further modeled using MCNP to determine the free electron production per neutron across the neutron energy spectrum, approximating their energy-dependent signal sensitivity. Our findings identified Samarium (Sm) and Gadolinium (Gd) as top candidates for thermal neutrons, Hafnium (Hf) and Thulium (Tm) for epithermal neutrons, and Tantalum (Ta) for fast neutrons. These materials will undergo future experimental validation to confirm the modeled responses and assess their feasibility for real-time neutron spectrum measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oak Ridge National Laboratory Neutron Spin Echo Beamline on NB-2

Neutron Spin Echo (NSE) spectroscopy uniquely measures the Q-dependence of slow relaxation dynamics, and having such a machine at HFIR will advance polarized neutron spectroscopy and promote the study of biophysical and energy materials using neutrons. The 2018 Instrument Advisory Board (IAB) advises Neutron Sciences Directorate, ORNL to upgrade the cold neutron delivery system at HFIR, addressing geometrical challenges in neutron transfer from the bright cold source. This is being optimized now: the entrance to the guide system is moving closer to the source, and more guides are being added. However, there are still significant challenges to making the cold flux at the sample world-class. With the proposed guide system, NB-2 can deliver more than 10 6 polarized neutrons per cm 2 /sec below 8Å, and probably 10Å with further optimization. With no potential for running user experiments with neutrons longer than 15Å, the utility of such a machine for biological studies is limited. However, there is a large demand for this class of spectrometer in materials science, chemical engineering, and nanotechnology. Workshops held over the past decade and the three-source vision have highlighted the community's need for a low-angle, high-energy resolution spectrometer at HFIR. A detailed design study of this spectrometer is needed, focusing on optimizing the neutron delivery system for SANS-type studies. This neutron spectrometer would complement studies already performed on both SNSNSE and BASIS by overlapping and extend the dynamic range accessible, while acknowledging the proposed machine, EXPANSE, at the Second Target Station. Two technologies currently exist for such a spectrometer: traditional DC solenoids like those on BL-15 at SNS and IN15 at the ILL, and RF-flipper-based machines similar to RESEDA at FRMII. Either instrument would satisfy the scientific justification. However, there are strong business and scientific cases to utilize the thermal flux, the resonant expertise developed at ORNL, and the potential to utilize an entangled beam of neutrons to probe quantum matter by adopting the neutron resonant spin-echo configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian Gaussian process inference for neutron spin echo measurement

Neutron spin echo (NSE) spectroscopy provides unique access to microscopic dynamics, but its application is often constrained by low neutron flux, long acquisition times, and significant noise. Here, we present a Bayesian inference approach based on Gaussian process regression (GPR) to reconstruct high-quality spin echo signals from sparse and noisy data by exploiting correlations in reciprocal space. Benchmarks on synthetic datasets and validation with experimental NSE measurements of dendrimers show that GPR suppresses noise, interpolates missing intensity values, and accommodates irregular observations. The method improves accuracy, shortens acquisition times, and enables high-throughput and real-time studies. Beyond NSE, the framework is broadly applicable to other low signal-to-noise ratio scattering techniques, thereby extending the scope of neutron spectroscopy.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Computational study of tungsten and depleted uranium photoneutron targets for a 20 MeV electron linear accelerator

Neutron production can be realized with a high energy electron linear accelerator by using Bremsstrahlung and photoneutron converters. In this study, Monte Carlo N-Particle Code (MCNP) was used to evaluate potential photonuclear target designs for a high energy electron linear accelerator for applications such as neutron radiography and neutron resonance spectroscopy. A computational model was developed to inform a target design that would yield a high number of neutrons. It consists of a 20 MeV electron beam incident on a Bremsstrahlung target and a photonuclear target to generate neutrons. This computational model showed that a thickness of 0.75 inches for both tungsten and depleted uranium yields the most neutrons from photoneutron reactions. Saturation in the total number of generated neutrons was observed at over 0.75-inch thickness for both evaluated materials. Depleted uranium yielded approximately twice the number of neutrons overall compared to tungsten. The highest neutron surface flux for Depleted Uranium was 1.06 × 10-4 neutrons/cm2/source electron, and for Tungsten it was 5.12 × 10-5 neutrons/cm2/source electron. The optimal target design for this study’s application would consist of a 0.75 inch-thick block of depleted uranium with the length, width, and/or diameter varying dependent on application.

43 PARTICLE ACCELERATORS↗