Enhancing VHTR Passive Safety and Economy with Thermal Radiation Based Direct Reactor Auxiliary Cooling System

One of the most important requirements for Gen. IV Very High Temperature Reactor (VHTR) is passive safety. Currently all the gas cooled version of VHTR designs use Reactor Vessel Auxiliary Cooling System (RVACS) for passive decay heat removal. The decay heat first is transferred to the core barrel by conduction and radiation, and then to the reactor vessel by thermal radiation and convection; finally the decay heat is transferred to natural circulated air or water systems. RVACS can be characterized as a surface based decay heat removal system. The RVACS is especially suitable for smaller power reactors since small systems have relatively larger surface area to volume ratio. However, RVACS limits the maximum achievable power level for modular VHTRs due to the mismatch between the reactor power (proportional to volume) and decay heat removal capability (proportional to surface area). When the relative decay heat removal capability decreases, the peak fuel temperature increases, even close to the design limit. Annular core designs with inner graphite reflector can mitigate this effect; therefore can further increase the reactor power. Another way to increase the reactor power is to increase power density. However, the reactor power is also limited by the decay heat removal capability. Besides the safety considerations, VHTRs also need to be economical in order to compete with other reactor concepts and other types of energy sources. The limit of decay heat removal capability set by using RVACS has affected the economy of VHTRs. A potential alternative solution is to use a volume-based passive decay heat removal system, called Direct Reactor Auxiliary Cooling Systems (DRACS), to remove or mitigate the limitation on decay heat removal capability. DRACS composes of natural circulation loops with two sets of heat exchangers, one on the reactor side and another on the environment side. For the reactor side, cooling pipes will be inserted into holes made in the outer or inner graphite reflector blocks. There will be gaps between these cooling pipes and their corresponding surrounding graphite surfaces. Graphite has an excellent heat conduction property. By taking advantage of this feature, we can have a volume-based method to remove decay heat. The scalability can be achieved, if needed, by employing more rows of cooling pipes to accommodate higher decay heat rates. Since heat can easily conduct through the graphite regions between the holes made for the cooling pipes, those cooling pipes located further away from the active core region can still be very effective in removing decay heat. By removing the limit on the decay heat removal capability due to the limited available surface area as in a RVACS, the reactor power and power density can be significantly increased, without losing the passive heat removal feature. This paper will introduce the concept of using DRACS to enhance VHTR passive safety and economics. Three design options will be discussed, depending on the cooling pipe locations. Analysis results from a lumped volume based model and CFD simulations will be presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-resolution wall temperature measurements with distributed fiber optic sensors

Conventional approaches of surface temperature measurement are often unreliable, and other methods may not be practical in closed, high-temperature spaces. In this study, surface temperature measurements of the cooling panel of a natural circulation facility were performed with fiber optic distributed temperature sensors (DTS). High resolution surface temperature profiles of the cooling panel were acquired under two steady experimental conditions, and compared with measurements performed with nearby thermocouples. The total measurement error of the DTS results presented has been estimated to be ±4.4 °C. The findings reflected herein show that these DTS can reasonably measure surface temperature when installed with the methods developed in this study. Through the analysis of the DTS data collected, the interesting behavior of the cooling panel was revealed, providing new insights on the system's behavior that may be beneficial to the design and optimization of such heat transfer devices. These sensors can also provide the measurement density necessary for validation efforts with highly-resolved prediction methods such as finite element analysis (FEA) or computational fluid dynamics (CFD).

47 OTHER INSTRUMENTATION↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗

Mixed Convection in the VHTR in the Event of a LOFA

The US Department of Energy, Office of Nuclear Energy (DOE-NE) is supporting the development of a very high temperature reactor (VHTR) concept as the primary focus of it next generation nuclear power plant (NGNP) program. The VHTR is cooled by forcing helium downwards through the core into the lower plenum and out the hot duct. In the event that the coolant circulators are lost, the driving pressure drop across the core will reduce to zero and there will be the opportunity for natural circulation to occur. During the time that the circulators are powering down, the heat transfer in the core from the graphite blocks to the helium coolant will transform from turbulent forced convection to mixed convection, where buoyancy effects become important, to free or natural convection, where buoyancy is dominant. Analysis of the nature of the forced, mixed and free convection is best done using computational fluid dynamic (CFD) software that can provide fine details of the flow and heat transfer. However, CFD analysis involves approximations in the results because of the finite nature of the spatial and temporal discretizations required, the inexact nature of the turbulence models that are used and the finite precision of the computers employed. Therefore, it is necessary to validate the CFD computations. Validation is accomplished by comparing results from specific CFD computations to experimental data that have been taken specifically for the purpose of validation and that are related to the physical phenomena in question. The present report examines the flow and heat transfer parameters (dimensionless numbers) that characterize the flow and reports ranges for their values based on specific CFD studies performed for the VHTR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Postulated Accident Scenarios for the Transformational Challenge Reactor

The Transformational Challenge Reactor (TCR) is a helium-cooled, yttrium-hydride-moderated reactor that was designed for the U.S. Department of Energy Office of Nuclear Energy. A key objective of the TCR was to employ advanced manufacturing techniques in a nuclear system and demonstrate their potential for revolutionizing the nuclear reactor design process. One purpose of the present work is to demonstrate the safety of the TCR under postulated accidents. Based on RELAP5-3D and COMSOL analyses, the TCR remained below all current safety limits and far below the expected failure limits for the core materials. Another purpose of this work is to provide useful insights and recommendations regarding the application of RELAP5-3D to gas-cooled or other advanced reactors. A novel approach was implemented for simultaneously modeling conduction and radiation in RELAP5-3D, which was found to provide reasonable predictions of radial core, vessel, and ex-vessel heat transfer during postulated events. A multicode approach was also applied, in which high-fidelity COMSOL calculations were used to tune the radial heat transfer parameters in RELAP5-3D. The tuned RELAP5-3D model demonstrated comparable peak temperature predictions as COMSOL, despite a coarse treatment of the core in RELAP5-3D consisting of only two lumped heat structures. This high-fidelity tuning approach enabled enhanced accuracy as well as minimal complexity within the RELAP5-3D model, even for complex fuel geometric designs as in the TCR. Finally, investigations were made into the potential for flow reversal during a pressurized loss-of-forced-flow event in the TCR. The TCR is designed with downward helium flow through the core during normal operation. The RELAP5-3D model predicted that this downward flow would persist, without flow reversal, up to several days after the circulator trip. This was attributed to natural circulation hysteresis effects as have been noted in similar thermofluidic systems. Although flow stagnation and eventual reversal did not lead to unsafe TCR conditions, interesting spatial effects were observed which may have safety relevance for other reactor system designs and coolant types that are designed for downward core flow during normal operation, warranting closer investigation of the flow reversal phenomenon.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An overview of the activities carried out by the IAEA Technical Working Group on Fast Reactors

The Technical Working Group on Fast Reactors (TWG-FR) of the International Atomic Energy Agency (IAEA) is a group of experts to provide advice and support programme implementation, reflecting a global network of excellence and expertise in the area of advanced technologies and R and O for fast reactors and sub-critical hybrid systems. Consistent with its mandate, the TWG-FR assists in defining and carrying out the Agency's activities in the field of nuclear power technology development for fast reactors and sub-critical hybrid systems. It promotes the exchange of information on national and multi-national programmes and new developments and experience, with the goal to identify and review problems of importance and to stimulate and facilitate cooperation, development and practical application of fast reactors and sub-critical hybrid systems. Finally, the TWG-FR provides Member States with information about the current status and development trends of advanced technologies for fast reactors and sub-critical hybrid systems. The TWG-FR coordinates its activities with other IAEA projects and initiatives, especially those of the Technical Working Group on Nuclear Fuel Cycle Options (TWG-NFCO), the Dept. of Nuclear Safety and Security and, last but not least, the International Project on Innovative Nuclear Reactors and the Fuel Cycle INPRO. It also cooperates with FR-related initiatives implemented within the framework of other international programmes (e.g. GIF, OECD/NEA, ESNII, etc.). The paper presents the recent relevant activities of the TWG-FR as well as the status of the current Coordinated Research Projects jointly carried out by a number of organizations representing the various Member States within the TWG-FR. In particular they concern benchmark analyses of: - the sodium natural circulation tests performed during Phenix End-of-Life experiments; - the sodium natural convection in the upper plenum of the Monju reactor vessel; - an EBR-II Shutdown Heat Removal Test. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bypass flow computations on the LOFA transient in a VHTR

Bypass flow in the prismatic gas-cooled very high temperature reactor (VHTR) is not intentionally designed to occur, but is present in the gaps between graphite blocks. Previous studies of the bypass flow in the core indicated that the cooling provided by flow in the bypass gaps had a significant effect on temperature and flow distributions for normal operating conditions. However, the flow and heat transports in the core are changed significantly after a Loss of Flow Accident (LOFA). This study aims to study the effect and role of the bypass flow after a LOFA in terms of the temperature and flow distributions and for the heat transport out of the core by natural convection of the coolant for a 1/12 symmetric section of the active core which is composed of images and mirror images of two sub-region models. The two sub-region models, 9 x 1/12 and 15 x 1/12 symmetric sectors of the active core, are employed as the CFD flow models using computational grid systems of 70.2 million and 117 million nodes, respectively. It is concluded that the effect of bypass flow is significant for the initial conditions and the beginning of LOFA, but the bypass flow has little effect after a long period of time in the transient computation of natural circulation.

99 GENERAL AND MISCELLANEOUS↗

STUDY ON AIR INGRESS MITIGATION METHODS IN THE VERY HIGH TEMPERATURE GAS COOLED REACTOR (VHTR)

An air-ingress accident followed by a pipe break is considered as a critical event for a very high temperature gas-cooled reactor (VHTR). Following helium depressurization, it is anticipated that unless countermeasures are taken, air will enter the core through the break leading to oxidation of the in-core graphite structure. Thus, without mitigation features, this accident might lead to severe exothermic chemical reactions of graphite and oxygen. Under extreme circumstances, a loss of core structural integrity may occur along with excessive release of radiological inventory. Idaho National Laboratory under the auspices of the U.S. Department of Energy is performing research and development (R&D) that focuses on key phenomena important during challenging scenarios that may occur in the VHTR. Phenomena Identification and Ranking Table (PIRT) studies to date have identified the air ingress event, following on the heels of a VHTR depressurization, as very important (Oh et al. 2006, Schultz et al. 2006). Consequently, the development of advanced air ingress-related models and verification and validation (V&V) requirements are part of the experimental validation plan. This paper discusses about various air-ingress mitigation concepts applicable for the VHTRs. The study begins with identifying important factors (or phenomena) associated with the air-ingress accident by using a root-cause analysis. By preventing main causes of the important events identified in the root-cause diagram, the basic air-ingress mitigation ideas can be conceptually derived. The main concepts include (1) preventing structural degradation of graphite supporters; (2) preventing local stress concentration in the supporter; (3) preventing graphite oxidation; (4) preventing air ingress; (5) preventing density gradient driven flow; (4) preventing fluid density gradient; (5) preventing fluid temperature gradient; (6) preventing high temperature. Based on the basic concepts listed above, various air-ingress mitigation methods are proposed in this study. Among them, the following two mitigation ideas are extensively investigated using computational fluid dynamic codes (CFD): (1) helium injection in the lower plenum, and (2) reactor enclosure opened at the bottom. The main idea of the helium injection method is to replace air in the core and the lower plenum upper part by buoyancy force. This method reduces graphite oxidation damage in the severe locations of the reactor inside. To validate this method, CFD simulations are addressed here. A simple 2-D CFD model is developed based on the GT-MHR 600MWt design. The simulation results showed that the helium replace the air flow into the core and significantly reduce the air concentration in the core and bottom reflector potentially protecting oxidation damage. According to the simulation results, even small helium flow was sufficient to remove air in the core, mitigating the air-ingress successfully. The idea of the reactor enclosure with an opening at the bottom changes overall air-ingress mechanism from natural convection to molecular diffusion. This method can be applied to the current system by some design modification of the reactor cavity. To validate this concept, this study also uses CFD simulations based on the simplified 2-D geometry. The simulation results showed that the enclosure open at the bottom can successfully mitigate air-ingress into the reactor even after on-set natural circulation occurs.

99 GENERAL AND MISCELLANEOUS↗

Passive compact molten salt reactor (PCMSR), modular thermal breeder reactor with totally passive safety system

Design Study Passive Compact Molten Salt Reactor (PCMSR) with totally passive safety system has been performed. The term of Compact in the PCMSR name means that the reactor system is designed to have relatively small volume per unit power output by using modular and integral concept. In term of modular, the reactor system consists of three modules, i.e. reactor module, turbine module and fuel management module. The reactor module is an integral design that consists of reactor, primary and intermediate heat exchangers and passive post shutdown cooling system. The turbine module is an integral design of a multi heating, multi cooling, regenerative gas turbine. The fuel management module consists of all equipments related to fuel preparation, fuel reprocessing and radioactive handling. The preliminary calculations show that the PCMSR has negative temperature and void reactivity coefficient, passive shutdown characteristic related to fuel pump failure and possibility of using natural circulation for post shutdown cooling system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A user's guide to the PLTEMP/ANL code.

PLTEMP/ANL V4.1 is a FORTRAN program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of ''PLTEMP'' codes in use at ANL for the past 20 years. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. The temperature solution is effectively 2-dimensional. It begins with a one-dimensional solution across all coolant channels and fuel plates/tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available with which to determine safety margins such as Onset-of-Nucleate boiling (ONB), departure from nucleate boiling (DNB), and onset of flow instability (FI). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst's time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Scaling-based Applicability Assessment of the CAER Integrated Systems Test Facility

This paper presents a scaling-based applicability assessment of the Integrated Systems Test (IST) facility located at the Center of Advanced Engineering Research in Forest, Virginia. The assessment draws upon both traditional and contemporary scaling methods, seeking an optimal representation of light water reactor (LWR) and small modular reactor (SMR) characteristics during design-basis events. Based on published LWR loss-of-coolant-accident phenomena identification and ranking tables compiled with a similar assessment completed by BWXT mPower, Inc., for the mPower{sup TM} SMR, the phenomena considered in the IST design include break flow, decay heat, loop thermal-hydraulics, and primary-to-secondary heat transfer. Among these, the single- and two-phase natural circulation and system depressurization, by association to loop thermal-hydraulics, were the principal challenges. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improvement of Wall Drag Modeling Capabilities of CTF

Coolant Boiling in Rod Arrays-Two Fluid (COBRA-TF), or CTF, is a nuclear thermal hydraulic subchannel code used throughout academia and industry. It solves discretized forms of nine coupled equations for the mass, momentum, and energy equations for the liquid and vapor fields; the mass and momentum equation for the droplet field; and the energy equation for solid structures. This work focuses on improving the wall drag modeling capabilities of CTF by adding new friction models that account for surface roughness. Prior to this work, CTF used simple correlations that assumed that surfaces were smooth. In reality, different materials in the reactor have varying degrees of roughness that act to increase drag and frictional pressure drop. The frictional pressure drop is important, as it partly defines the driving head necessary for achieving certain flow conditions. This is particularly important in passively cooled systems that rely on natural circulation. Therefore, the effects of surface roughness cannot be neglected, as it affects flow rate and distribution, heat transfer and turbulence. (authors)

42 ENGINEERING↗

Simulation of the passive condensation cooling tank of the PASCAL test facility using the component thermal-hydraulic analysis code CUPID

For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. In the present study, the CUPID code was applied for the simulation of the PASCAL (PAFS Condensing Heat Removal Assessment Loop) test facility constructed with an aim of validating the cooling and operational performance of the PAFS (Passive Auxiliary Feedwater System). The PAFS is one of the advanced safety features adopted in the APR+ (Advanced Power Reactor +), which is intended to completely replace the conventional active auxiliary feedwater system. This paper presents the preliminary simulation results of the PASCAL facility performed with the CUPID code in order to verify its applicability to the thermal-hydraulic phenomena inside the system. A standalone calculation for the passive condensation cooling tank was performed by imposing a heat source boundary condition and the transient thermal-hydraulic behaviors inside the system, such as the water level, temperature and velocity, were qualitatively investigated. The simulation results verified that the natural circulation and boiling phenomena in the water pool can be well reproduced by the CUPID code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Compact D-D Neutron Source-Driven Subcritical Multiplier and Beam-Shaping Assembly for Boron Neutron Capture Therapy

This work assesses the feasibility of using a small, safe, and inexpensive keff 0.98 subcritical fission assembly [subcritical neutron multiplier (SCM)] to amplify the treatment neutron beam intensity attainable from a compact deuterium-deuterium (D-D) fusion neutron source delivering [approximately]1012 n/s. The objective is to reduce the treatment time for deep-seated brain tumors to [approximately]1 h. The paper describes the optimal SCM design and two optimal beam-shaping assemblies (BSAs) - one designed to maximize the dose rate and the other designed to maximize the total dose that can be delivered to a deep-seated tumor. The neutron beam intensity amplification achieved with the optimized SCM and BSA results in an increase in the treatment dose rate by a factor of 18: from 0.56 Gy/h without the SCM to 10.1 Gy/h. The entire SCM is encased in an aluminum structure. The total amount of 20% enriched uranium required for the SCM is 8.5 kg, and the cost (not including fabrication) is estimated to be less than $60,000. The SCM power level is estimated at 400 W when driven by a 1012 n/s D-D neutron source. This translates into consumption of only [approximately]0.6% of the initially loaded 235U atoms during 50 years of continuous operation and implies that the SCM could operate continuously for the entire lifetime of the facility without refueling. Cooling the SCM does not pose a challenge; it may be accomplished by natural circulation as the maximum heat flux is only 0.034 W/cm2.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On Physics-Based Preconditioning of the Navier-Stokes Equations

An new and more ecient all-speed flow algorithm is developed. The governing hy- drodynamic equations, in conservative form, are solved implicitly using Jacobian- free Newton-Krylov methods. To overcome numerical stiffness caused by the dis- parity between acoustic and advective modes, the governing hydrodynamic equa- tions are transformed to the primitive variable form in a preconditioning step. This transformation enables implicit treatment of distinct physics using traditional semi- implicit and physics-based splitting approaches without a loss of consistency be- tween the original and preconditioned systems. The resulting algorithm is capable of solving slow natural circulations (M ~ 10^-4) with signicant heat flux as well as the high-speed (M ~ 1) flows effciently by following dynamical time scales.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A User's Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.2 is a FORTRAN program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of ''PLTEMP'' codes in use at ANL for the past 20 years. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. The temperature solution is effectively 2-dimensional. It begins with a one-dimensional solution across all coolant channels and fuel plates/tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available with which to determine safety margins such as Onset-of- Nucleate boiling (ONB), departure from nucleate boiling (DNB), and onset of flow instability (FI). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.