Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NSLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Optimization of echo-enabled harmonic generation toward coherent EUV and soft X-ray free-electron laser at NSLS-II

Prebunching via echo-enabled harmonic generation (EEHG) is an efficient way to reduce the radiator length and improve the longitudinal coherence as well as output stability in storage-ring-based free-electron lasers. We propose a conceptual design, which uses two straight sections to seed coherent extreme-ultraviolet (EUV) and soft X-ray emission with nearly MHz repetition rate. To take the large energy spread (10 –3 ) of a storage ring into account and utilize the existing bending magnets between the two straight sections as the first chicane, we implement a special modeling tool, named EEHG optimizer. This tool has been successfully applied to maximize the prebunching with a reasonably low energy modulation, thereby generating intense coherent X-ray pulses within a short undulator length (a few meters) limited by the available space of a storage ring. Numerical simulations confirm that the optimized EEHG parameters can be directly applied to generate a 10 MW scale peak power with fully coherent ultrafast EUV to soft X-ray pulses based on the NSLS-II parameters. This method can be easily extended to other types of diffraction-limited storage rings.

36 MATERIALS SCIENCE↗

Optical Design of $\mathrm{DEI/ABI}$ System at the $\mathrm{HEX}$ Beamline at the $\mathrm{NSLS-II}$

Diffraction Enhanced Imaging (DEI) or Analyzer Based Imaging (ABI) uses a perfect crystal monochromator and matching analyzer to achieve sensitivity to x-ray refraction and ultra small-angle scattering on the order of 0.01 micro-radians. As such, a thermal bump caused by heat-load in the order of 1 W is detrimental. The heat load at the HEX (High Energy Engineering X-ray) super-conducting wiggler (SCW) beamline, under construction at the NSLS-II, is on the order of 1 kW. How to reconcile the three orders of magnitude difference between the HEX source power and the DEI/ABI requirements? The solution involves using a double-crystal bent-Laue monochromator as pre-monochromator to prepare a beam with a large divergence and bandwidth that is matched to a flat crystal post-monochromator. We show through phase-space (x-ray energy vs. angle as viewed by a flat crystal) analysis and Dumond diagrams that there is indeed a unique bending radius that matches the double-crystal bent-Laue monochromator in phase space to the flat Bragg crystal. The matched system has a desirable feature that the phase space of the bent crystal’s output beam is much larger than that of the flat crystal, making the combined system stable. Based on these considerations, here we present our optical design for performing DEI/ABI at the HEX beamline

36 MATERIALS SCIENCE↗

The Electron Spectro-Microscopy (ESM) Beamline at NSLS-II

Photoelectron spectroscopy is a primary tool for the study of the electronic structure of materials and the chemical composition of surfaces. High-resolution angle-resolved photoemission spectroscopy (ARPES) has the unique ability to map the energy bands in momentum space. Furthermore, going beyond the single particle picture, the self-energy corrections caused by correlations in solids can be extracted from the analysis of the emission line shape. The current level of refinement, in terms of energy and angular resolution (ΔE < 1 meV, Δθ < 0.1°), makes the technique sensitive to the lowest energy excitations and the dynamics of electrons, which in turn virtually determine all the macroscopic properties of any system and govern the chemical, electrical, magnetic, and physical processes. Similarly important, X-ray photoelectron microscopy (XPEEM), combined with the low-energy electron microscopy (LEEM), is indispensable in probing the complexity of chemical, structural, electronic and magnetic properties of surfaces and shallow interfaces, with the spatial resolution of few tens of nanometer (nm). The Electron-Spectro-Microscopy beamline (ESM) has been recently commissioned at NSLS-II and is now in operation. The primary spectroscopic technique is photoemission, performed over a wide energy range with control of light polarization and in a variety of flux/resolution conditions. The beamline has two experimental end stations that allow to perform ARPES and XPEEM/LEEM, separately. The ARPES end station focuses on high energy-resolution work, with spot-size of a few microns. The XPEEM/LEEM end station is a full-field microscope (XPEEM) operating either with the synchrotron generated X-rays (XPEEM), or with an internal electron gun (LEEM). Spatial resolution is crucial in studies of newly synthesized complex materials since they are often initially available only as small specimens (typically micron size). Furthermore, chemical inhomogeneities on surfaces are often an integral part of surface chemical processes. Finally, the ESM beamline with X-ray spots of few microns is optimized to study the electronic structure of novel materials with microscopy capabilities.

47 OTHER INSTRUMENTATION↗

Linear optics compensation for the HEX superconducting wiggler at NSLS-II

At the NSLS-II ring, a 1.2 m long superconducting wiggler with the maximum 4.34T magnetic field has been installed at a low-β straight section (cell 27) to drive the high energy engineering X-ray scattering (HEX) beamline. To mitigate the potential performance degradation due to the linear optics distortion, a local compensation scheme was adopted and confirmed with the online beam measurement. A feedforward control to enable a dynamic compensation of the linear optics distortion was deployed. It can maintain the storage ring lattice performance when the device main coil current ramps.

36 MATERIALS SCIENCE↗

The Inner Shell Spectroscopy beamline at NSLS-II: a facility for in situ and operando X-ray absorption spectroscopy for materials research

The Inner Shell Spectroscopy (ISS) beamline on the 8-ID station at the National Synchrotron Light Source II (NSLS-II), Upton, NY, USA, is a high-throughput X-ray absorption spectroscopy beamline designed for in situ, operando, and time-resolved material characterization using high monochromatic flux and scanning speed. This contribution discusses the technical specifications of the beamline in terms of optics, heat load management, monochromator motion control, and data acquisition and processing. Results of the beamline tests demonstrating the quality of the data obtainable on the instrument, possible energy scanning speeds, as well as long-term beamline stability are shown. The ability to directly control the monochromator trajectory to define the acquisition time for each spectral region is highlighted. Examples of studies performed on the beamline are presented. The paper is concluded with a brief outlook for future developments.

36 MATERIALS SCIENCE↗

A new Kirkpatrick–Baez-based scanning microscope for the Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II

The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick–Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

36 MATERIALS SCIENCE↗

AMX – the highly automated macromolecular crystallography (17-ID-1) beamline at the NSLS-II

The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 10 12 photons s −1 ), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5–18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.

36 MATERIALS SCIENCE↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Optimization of an In-Vacuum Undulator at NSLS-II Transactions on Applied Superconductivity

A 3.0 m long In-Vacuum Undulator (IVU) is employed at the National Synchrotron Light Source II (NSLS-II) for the Hard X-ray Nanoprobe (HXN) beamline providing structural and X-ray fluorescence imaging with world-leading spatial resolution. On July 1 st 2018 a gearbox shaft in the gap drive train assembly sheared due to corrosion fatigue caused by stress due to mechanical misalignment. Furthermore, the device was extracted from the storage ring and measured. The magnetic field measurements detected a degradation of the magnetic performance as well as a localized demagnetization of the magnetic modules of the first 3 upstream periods. We describe here the mechanical repairs and the magnetic phase shimming optimization implemented to restore the spectral performance of the device.

43 PARTICLE ACCELERATORS↗

Phasing Magnet for CSX-2 Beamline at NSLS-II

A phasing magnet has been developed at National Synchrotron Light Source II (NSLS-II) for the Coherent Soft X-ray Scattering (CSX) beamline. The phasing magnet will be located at the center of the straight section in between two identical and independent variably polarized APPLE-II devices. Based on Permanent Magnet technology, the phasing magnet has been designed to achieve the required electron beam delay to properly adjust the phase matching of these two consecutive EPUs (Elliptically Polarizing Undulators) and ensure a positive interference between the photon beam emitted in each device. Also this paper will describe the mechanical and magnetic design together with the final field measurements and magnetic tuning results. Also, the spectral performance of the two EPUs and the method used to properly set the field strength of the phasing magnet for any given radiation wavelength and polarization mode will be presented as well.

36 MATERIALS SCIENCE↗

On-axis 3D microscope for x-ray beamlines at NSLS-II

A series of versatile on-axis X-ray microscopes with large working distances, high resolution and large magnification have been developed at NSLS-II [1,2]. These microscopes use reflective optics, which minimizes dispersion, and allows imaging from Ultraviolet (UV) [3] to Infrared (IR) with specifically chosen objective components (coatings, etc.). Additional customizations can be implemented to provide dual-view with high/low magnification [4], 3-D imaging, long working range, as well as ruby fluorescence measurement for high pressure samples. In this publication we discuss 3D imaging enhancement to on-axis microscopes.

47 OTHER INSTRUMENTATION↗

A New Magnetic Measurement System for the Future Low Emittance NSLS-II Storage Ring

A new magnetic measurement system is under construc-tion at BNL for accurate field harmonic measurements and fiducialization of magnets for a future upgrade of the NSLS- II storage ring. The entire storage ring is envi-sioned to be replaced with a new lattice concept, known as Complex Bend, which superimposes dipole and high-gradient quadrupole fields. The magnetic measurement system will use rotating wire and a PCB rotating coil specifically designed for small-aperture (< 15 mm) high gradient magnets. In this paper we describe in detail the mechanical design and the data acquisition hardware and software.

43 PARTICLE ACCELERATORS↗

A New Experimental Station for Liquid Interface X-Ray Scattering At NSLS-II Beamline 12-ID

Open Platform and Liquids Scattering (OPLS) is a new experimental station recently built and currently being commissioned at the Soft Matter Interfaces (SMI) beamline 12-ID at NSLS-II. The new instrument expands SMI’s beamline scientific capabilities via the addition of X-ray scattering techniques from liquid surfaces and interfaces. The design of this new instrument, located inside the 12-ID beamline shielding enclosure (hutch B), is based on a single Ge (111) crystal deflector, which bounces the incident x-ray beam downward towards a liquid sample which must be maintained in a horizontal orientation (gravity-driven consideration). The OPLS instrument has a variable deflector-to-sample distance ranging from 0.6 m to 1.5 m. X-ray detectors are mounted on a 2-theta scattering arm located downstream of the sample location. The 2-theta arm is designed to hold up to three X-ray detectors, with fixed 2-theta angular offsets, each dedicated to a different X-ray technique such as X-ray reflectivity, grazing-incidence X-ray scattering, and small- and wide-angle X-ray scattering. Currently, the OPLS experimental station intercepts the SMI beam that otherwise propagates to the experimental endstation located in hutch C and can be retracted to a ’parking’ position laterally out of this beam to allow installation of a removable beam pipe that is needed to support operations in hutch C. The design of OPLS is flexible enough to quickly adapt to a planned future configuration of the SMI beamline in which a OPLS is illuminated separately from the main SMI branch via a second, canted undulator source and a separate photon delivery system. In this future configuration, both branches will be able to operate independently and simultaneously.

36 MATERIALS SCIENCE↗

A New PCB Rotating Coil at NSLS-II

Several R&D projects are underway at NSLS-II towards an upgrade of its storage ring with a new lattice that will use high field magnets with small bores of 16-22 mm. A large fraction of the high field magnets are expected to be of permanent magnet technology that will require precise magnetic measurements and field harmonics corrections. A new magnetic measurement bench has been built based on a printed circuit board (PCB) coil of 12 mm diameter and 270 mm active length. This PCB coil has the capabil-ity of measuring field quality to a level of 10 ppm of the main field up to the 15th harmonic with a sensitivity between 0.01 m2 and 0.02 m2 at the reference radius of 5 mm. This paper will describe the main features of the rotating coil bench and discuss the measurement results of a permanent-magnet Halbach quadrupole of 12.7 mm bore diameter.

43 PARTICLE ACCELERATORS↗

NSLS-II: Nonlinear Model Calibration for Synchrotrons

This tech note is essentially a summary of a lecture we delivered to the Acc. Phys. Journal Club Apr, 2010. However, since the estimated accuracy of these methods has been naive and misleading in the field of particle accelerators, i.e., ignores the impact of noise, we will elaborate on this in some detail. A prerequisite for a calibration of the nonlinear Hamiltonian is that the quadratic part has been understood, i.e., that the linear optics for the real accelerator has been calibrated. For synchrotron light source operations, this problem has been solved by the interactive LOCO technique/tool (Linear Optics from Closed Orbits). Before that, in the context of hadron accelerators, it has been done by signal processing of turn-by-turn BPM data. We have outlined how to make a basic calibration of the nonlinear model for synchrotrons. In particular, we have shown how this was done for LEAR, CERN (antiprotons) in the mid-80s. Specifically, our accuracy for frequency estimation was {approx} 1 x 10{sup -5} for 1024 turns (to calibrate the linear optics) and {approx} 1 x 10{sup -4} for 256 turns for tune footprint and betatron spectrum. For a comparison, the estimated tune footprint for stable beam for NSLS-II is {approx}0.1. Since the transverse damping time is {approx}20 msec, i.e., {approx}4,000 turns. There is no fundamental difference for: antiprotons, protons, and electrons in this case. Because the estimated accuracy for these methods in the field of particle accelerators has been naive, i.e., ignoring the impact of noise, we have also derived explicit formula, from first principles, for a quantitative statement. For e.g. N = 256 and 5% noise we obtain {delta}{nu} {approx} 1 x 10{sup -5}. A comparison with the state-of-the-arts in e.g. telecomm and electrical engineering since the 60s is quite revealing. For example, Kalman filter (1960), crucial for the: Ranger, Mariner, and Apollo (including the Lunar Module) missions during the 60s. Or Claude Shannon et al since the 40s for that matter. Conclusion: what's elementary in the latter is considered 'advanced', if at all, in the former. It is little surprise then that published measurements typically contains neither error bars (for the random errors) nor estimates for the systematic in the former discipline. We have also showed how to estimate the state space by turn-by-turn data from two adjacent BPMs. And how to improve the resolution of the nonlinear resonance spectrum by Fourier analyzing the linear action variables instead of the betatron motion. In fact, the state estimator could be further improved by adding a Kalman filter. For transparency, we have also summarized on how these techniques provide a framework- and method for a TQM (Total Quality Management) approach for the main ring. Of course, to make the ($2.5M) turn-by-turn data acquisition system that is being implemented (for all the BPMs) useful, a means ({approx}10% contingency for the BPM system) to drive the beam is obviously required.

43 PARTICLE ACCELERATORS↗

Optimisation of NSLS-II Blade X-ray Beam Position Monitors: from Photoemission type to Diamond Detector

Optimisation of blade type x-ray beam position monitors (XBPM) was performed for NSLS-II undulator IVU20. Blade material, con and #64257;guration and operation principle was analysed in order to improve XBPM performance. Optimisation is based on calculation of the XBPM signal spatial distribution. Along with standard photoemission type XBPM a Diamond Detector Blades (DDB) were analysed as blades for XBPMs. DDB XBPMs can help to overcome drawbacks of the photoemission blade XBPMs.

43 PARTICLE ACCELERATORS↗

Settings of the NSLS-II BSR magnets for energy interlock

It was determined that for the commissioning purposes energy range of the beam reaching the NSLS-II storage ring (SR) is allowed to be 2 GeV - 3.15 GeV. The Booster to SR (BSR) bends B1 and B2 interlocked at their nominal 3 GeV settings with ± 5% window provide the required “energy filter”. Another scenario of Booster operation suggests extracting the beam from the Booster to the BSR phase 1 line (or dump line). Under these circumstances the bend B2 is turned off. An adequate shielding is planned in BSR phase one line for B1 set within the boundaries of its 2 GeV nominal setting minus 5% and its 3 GeV setting plus 5 %. The goal of this exercise is to find the proper settings of respective bends PS currents, which will realize described interlock.

43 PARTICLE ACCELERATORS↗

Safe operating conditions for NSLS-II Storage Ring Frontends commissioning

The NSLS-II Storage Ring Frontends are designed to safely accept the synchrotron radiation fan produced by respective insertion device when the electron beam orbit through the ID is locked inside the predefined Active Interlock Envelope. The Active Interlock is getting enabled at a particular beam current known as AI safe current limit. Below such current the beam orbit can be anywhere within the limits of the SR beam acceptance. During the FE commissioning the beam orbit is getting intentionally disturbed in the particular ID. In this paper we explore safe operating conditions for the Frontends commissioning.

43 PARTICLE ACCELERATORS↗