Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

Purpose: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).Methods: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Results: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion-blurring artifacts are present, leading to a 24.4% relative reconstruction error in the NACT phantom. View aliasing artifacts are present in 4D-CBCT reconstructed by FDK from 20 projections, with a relative error of 32.1%. When total variation minimization is used to reconstruct 4D-CBCT, the relative error is 18.9%. Image quality of 4D-CBCT is substantially improved by using the SMEIR algorithm and relative error is reduced to 7.6%. The maximum error (MaxE) of tumor motion determined from the DVF obtained by demons registration on a FDK-reconstructed 4D-CBCT is 3.0, 2.3, and 7.1 mm along left–right (L-R), anterior–posterior (A-P), and superior–inferior (S-I) directions, respectively. From the DVF obtained by demons registration on 4D-CBCT reconstructed by total variation minimization, the MaxE of tumor motion is reduced to 1.5, 0.5, and 5.5 mm along L-R, A-P, and S-I directions. From the DVF estimated by SMEIR algorithm, the MaxE of tumor motion is further reduced to 0.8, 0.4, and 1.5 mm along L-R, A-P, and S-I directions, respectively.Conclusions: The proposed SMEIR algorithm is able to estimate a motion model and reconstruct motion-compensated 4D-CBCT. The SMEIR algorithm improves image reconstruction accuracy of 4D-CBCT and tumor motion trajectory estimation accuracy as compared to conventional sequential 4D-CBCT reconstruction and motion estimation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of image guided motion management methods in lung cancer radiotherapy

Purpose: To evaluate the accuracy and reliability of three target localization methods for image guided motion management in lung cancer radiotherapy. Methods: Three online image localization methods, including (1) 2D method based on 2D cone beam (CB) projection images, (2) 3D method using 3D cone beam CT (CBCT) imaging, and (3) 4D method using 4D CBCT imaging, have been evaluated using a moving phantom controlled by (a) 1D theoretical breathing motion curves and (b) 3D target motion patterns obtained from daily treatment of 3 lung cancer patients. While all methods are able to provide target mean position (MP), the 2D and 4D methods can also provide target motion standard deviation (SD) and excursion (EX). For each method, the detected MP/SD/EX values are compared to the analytically calculated actual values to calculate the errors. The MP errors are compared among three methods and the SD/EX errors are compared between the 2D and 4D methods. In the theoretical motion study (a), the dependency of MP/SD/EX error on EX is investigated with EX varying from 2.0 cm to 3.0 cm with an increment step of 0.2 cm. In the patient motion study (b), the dependency of MP error on target sizes (2.0 cm and 3.0 cm), motion patterns (four motions per patient) and EX variations is investigated using multivariant linear regression analysis. Results: In the theoretical motion study (a), the MP detection errors are −0.2 ± 0.2, −1.5 ± 1.1, and −0.2 ± 0.2 mm for 2D, 3D, and 4D methods, respectively. Both the 2D and 4D methods could accurately detect motion pattern EX (error < 1.2 mm) and SD (error < 1.0 mm). In the patient motion study (b), MP detection error vector (mm) with the 2D method (0.7 ± 0.4) is found to be significantly less than with the 3D method (1.7 ± 0.8,p < 0.001) and the 4D method (1.4 ± 1.0, p < 0.001) using paired t-test. However, no significant difference is found between the 4D method and the 3D method. Based on multivariant linear regression analysis, the variances of MP error in SI direction explained by target sizes, motion patterns, and EX variations are 9% with the 2D method, 74.4% with the 3D method, and 27% with the 4D method. The EX/SD detection errors are both < 1.0 mm for the 2D method and < 2.0 mm for the 4D method. Conclusions: The 2D method provides the most accurate MP detection regardless of the motion pattern variations, while its performance is limited by the accuracy of target identification in the projection images. The 3D method causes the largest error in MP determination, and its accuracy significantly depends on target sizes, motion patterns, and EX variations. The 4D method provides moderate MP detection results, while its accuracy relies on a regular motion pattern. In addition, the 2D and 4D methods both provide accurate measurement of the motion SD/EX, providing extra information for motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Applicability of 1D site response analysis to shallow sedimentary basins: A critical evaluation through physics-based 3D ground motion simulations

One-dimensional site response analysis (1D SRA) remains the standard practice in considering the effect of local soil deposits and predicting site-specific ground motions, although its range of applicability to realistic seismic wavefields is still in question. In this 1D approach, horizontal and vertical ground shaking are assumed to be induced by vertically propagating shear and compressional waves, respectively. A recent study based on analytical two-dimensional (2D) plane waves and simple point source earthquake simulations has shown two mechanistic limitations in this 1D modelling technique for general inclined seismic waves, that is, systematic over-prediction of the vertical motion and wave trapping in the 1D soil column. In this article, we evaluate in detail the applicability of this 1D modelling approach to realistic three-dimensional (3D) simulated seismic wavefields in shallow sedimentary basins. Linear-viscoelastic 1D SRA predictions using two types of input motions that are commonly used in practice—rock outcrop and in-column motions, are compared with the reference true site response results from 3D earthquake simulations in terms of various measures in the frequency and time domain. It is shown that the horizontal motion in the 3D seismic wavefield exhibits dominant shear wave propagation phenomenon, while the vertical motion is a combined effect of compressional and shear waves and can be over-predicted by the 1D approach when the incident seismic waves are inclined. Direct evidence of the wave refraction process that leads to the vertical motion over-prediction is provided. 1D SRA with in-column inputs can yield motions that have significantly longer duration compared to the true 3D site response solution due to trapped waves, casting in doubt the frequent need for increased soil damping in existing site studies to compensate for wave attenuation due to scattering alone. Sensitivity investigation on the increase of soil profile damping by a multiplier D mul shows D mul values compatible with those found in the literature for both horizontal and vertical motions. It is shown that the level of D mul optimized for a best match of the spectral acceleration is dependent on the characteristic of the input motion and a larger D mul is typically required for the vertical component. In contrast, 1D SRA with outcrop motions predicts motions with shorter significant duration due to its inability to capture the basin-edge generated surface waves. A suite of ground motion simulations was performed to assess the sensitivity of the observations to the basin geologic structure including the velocity gradient, rock-basin impedance contrast and basin depth. The analysis results show that the accuracy of the simplified 1D procedure is dependent on the wavefield composition of both the input motions and the true 3D site response solution. While the horizontal motions in shallow sedimentary basins can, to the first order, be reasonably captured by the simplified 1D approach, 1D SRA for the vertical component is in general not reliable and contributions from inclined shear waves should be accounted for in site-specific evaluation of the vertical design ground motion.

1D assumption↗

A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities

Purpose: To develop a physical, adaptive motion perturbation model to predict tumor motion using feedback from dynamic measurement of breathing conditions to compensate for breathing irregularities. Methods and Materials: A novel respiratory motion perturbation (RMP) model was developed to predict tumor motion variations caused by breathing irregularities. This model contained 2 terms: the initial tumor motion trajectory, measured from 4-dimensional computed tomography (4DCT) images, and motion perturbation, calculated from breathing variations in tidal volume (TV) and breathing pattern (BP). The motion perturbation was derived from the patient-specific anatomy, tumor-specific location, and time-dependent breathing variations. Ten patients were studied, and 2 amplitude-binned 4DCT images for each patient were acquired within 2 weeks. The motion trajectories of 40 corresponding bifurcation points in both 4DCT images of each patient were obtained using deformable image registration. An in-house 4D data processing toolbox was developed to calculate the TV and BP as functions of the breathing phase. The motion was predicted from the simulation 4DCT scan to the treatment 4DCT scan, and vice versa, resulting in 800 predictions. For comparison, noncorrected motion differences and the predictions from a published 5-dimensional model were used. Results: The average motion range in the superoinferior direction was 9.4 ± 4.4 mm, the average ΔTV ranged from 10 to 248 mm{sup 3} (−26% to 61%), and the ΔBP ranged from 0 to 0.2 (−71% to 333%) between the 2 4DCT scans. The mean noncorrected motion difference was 2.0 ± 2.8 mm between 2 4DCT motion trajectories. After applying the RMP model, the mean motion difference was reduced significantly to 1.2 ± 1.8 mm (P=.0018), a 40% improvement, similar to the 1.2 ± 1.8 mm (P=.72) predicted with the 5-dimensional model. Conclusions: A novel physical RMP model was developed with an average accuracy of 1.2 ± 1.8 mm for interfraction motion prediction, similar to that of a published lung motion model. This physical RMP was analytically derived and is able to adapt to breathing irregularities. Further improvement of this RMP model is under investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Liver motion during cone beam computed tomography guided stereotactic body radiation therapy

Purpose: Understanding motion characteristics of liver such as, interfractional and intrafractional motion variability, difference in motion within different locations in the organ, and their complex relationship with the breathing cycles are particularly important for image-guided liver SBRT. The purpose of this study was to investigate such motion characteristics based on fiducial markers tracked with the x-ray projections of the CBCT scans, taken immediately prior to the treatments. Methods: Twenty liver SBRT patients were analyzed. Each patient had three fiducial markers (2 Multiplication-Sign 5-mm gold) percutaneously implanted around the gross tumor. The prescription ranged from 2 to 8 fractions per patient. The CBCT projections data for each fraction ({approx}650 projections/scan), for each patient, were analyzed and the 2D positions of the markers were extracted using an in-house algorithm. In total, >55 000 x-ray projections were analyzed from 85 CBCT scans. From the 2D extracted positions, a 3D motion trajectory of the markers was constructed, from each CBCT scans, resulting in left-right (LR), anterior-posterior (AP), and cranio-caudal (CC) location information of the markers with >55 000 data points. The authors then analyzed the interfraction and intrafraction liver motion variability, within different locations in the organ, and as a function of the breathing cycle. The authors also compared the motion characteristics against the planning 4DCT and the RPM Trade-Mark-Sign (Varian Medical Systems, Palo Alto, CA) breathing traces. Variations in the appropriate gating window (defined as the percent of the maximum range at which 50% of the marker positions are contained), between fractions were calculated as well. Results: The range of motion for the 20 patients were 3.0 {+-} 2.0 mm, 5.1 {+-} 3.1 mm, and 17.9 {+-} 5.1 mm in the planning 4DCT, and 2.8 {+-} 1.6 mm, 5.3 {+-} 3.1 mm, and 16.5 {+-} 5.7 mm in the treatment CBCT, for LR, AP, and CC directions, respectively. The range of respiratory period was 3.9 {+-} 0.7 and 4.2 {+-} 0.8 s during the 4DCT simulation and the CBCT scans, respectively. The authors found that breathing-induced AP and CC motions are highly correlated. That is, all markers moved cranially also moved posteriorly and vice versa, irrespective of the location. The LR motion had a more variable relationship with the AP/CC motions, and appeared random with respect to the location. That is, when the markers moved toward cranial-posterior direction, 58% of the markers moved to the patient-right, 22% of the markers moved to the patient-left, and 20% of the markers had minimal/none motion. The absolute difference in the motion magnitude between the markers, in different locations within the liver, had a positive correlation with the absolute distance between the markers (R{sup 2}= 0.69, linear-fit). The interfractional gating window varied significantly for some patients, with the largest having 29.4%-56.4% range between fractions. Conclusions: This study analyzed the liver motion characteristics of 20 patients undergoing SBRT. A large variation in motion was observed, interfractionally and intrafractionally, and that as the distance between the markers increased, the difference in the absolute range of motion also increased. This suggests that marker(s) in closest proximity to the target be used.

60 APPLIED LIFE SCIENCES↗

Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum improvement of the NCC value by 100% and of the RMSD value by 81%. The corresponding maximum improvements for the registration-based approach were 20% and 40%. In phases with very rapid motion the registration-based algorithm obtained better image quality, while the image quality of the MAM algorithm was superior in phases with less motion. The image quality improvement of the MAM optimization was visually confirmed for the different clinical cases. Conclusions: The proposed method allows a software-based best-phase image quality improvement in coronary CT angiography. A short scan data interval at the target heart phase is sufficient, no additional scan data in other cardiac phases are required. The algorithm is therefore directly applicable to any standard cardiac CT acquisition protocol.

60 APPLIED LIFE SCIENCES↗

Using an external surrogate for predictor model training in real-time motion management of lung tumors

Purpose: Precise prediction of respiratory motion is a prerequisite for real-time motion compensation techniques such as beam, dynamic couch, or dynamic multileaf collimator tracking. Collection of tumor motion data to train the prediction model is required for most algorithms. To avoid exposure of patients to additional dose from imaging during this procedure, the feasibility of training a linear respiratory motion prediction model with an external surrogate signal is investigated and its performance benchmarked against training the model with tumor positions directly. Methods: The authors implement a lung tumor motion prediction algorithm based on linear ridge regression that is suitable to overcome system latencies up to about 300 ms. Its performance is investigated on a data set of 91 patient breathing trajectories recorded from fiducial marker tracking during radiotherapy delivery to the lung of ten patients. The expected 3D geometric error is quantified as a function of predictor lookahead time, signal sampling frequency and history vector length. Additionally, adaptive model retraining is evaluated, i.e., repeatedly updating the prediction model after initial training. Training length for this is gradually increased with incoming (internal) data availability. To assess practical feasibility model calculation times as well as various minimum data lengths for retraining are evaluated. Relative performance of model training with external surrogate motion data versus tumor motion data is evaluated. However, an internal–external motion correlation model is not utilized, i.e., prediction is solely driven by internal motion in both cases. Results: Similar prediction performance was achieved for training the model with external surrogate data versus internal (tumor motion) data. Adaptive model retraining can substantially boost performance in the case of external surrogate training while it has little impact for training with internal motion data. A minimum adaptive retraining data length of 8 s and history vector length of 3 s achieve maximal performance. Sampling frequency appears to have little impact on performance confirming previously published work. By using the linear predictor, a relative geometric 3D error reduction of about 50% was achieved (using adaptive retraining, a history vector length of 3 s and with results averaged over all investigated lookahead times and signal sampling frequencies). The absolute mean error could be reduced from (2.0 ± 1.6) mm when using no prediction at all to (0.9 ± 0.8) mm and (1.0 ± 0.9) mm when using the predictor trained with internal tumor motion training data and external surrogate motion training data, respectively (for a typical lookahead time of 250 ms and sampling frequency of 15 Hz). Conclusions: A linear prediction model can reduce latency induced tracking errors by an average of about 50% in real-time image guided radiotherapy systems with system latencies of up to 300 ms. Training a linear model for lung tumor motion prediction with an external surrogate signal alone is feasible and results in similar performance as training with (internal) tumor motion. Particularly for scenarios where motion data are extracted from fluoroscopic imaging with ionizing radiation, this may alleviate the need for additional imaging dose during the collection of model training data.

60 APPLIED LIFE SCIENCES↗

SU-F-J-133: Adaptive Radiation Therapy with a Four-Dimensional Dose Calculation Algorithm That Optimizes Dose Distribution Considering Breathing Motion

Purpose: To model patient motion and produce four-dimensional (4D) optimized dose distributions that consider motion-artifacts in the dose calculation during the treatment planning process. Methods: An algorithm for dose calculation is developed where patient motion is considered in dose calculation at the stage of the treatment planning. First, optimal dose distributions are calculated for the stationary target volume where the dose distributions are optimized considering intensity-modulated radiation therapy (IMRT). Second, a convolution-kernel is produced from the best-fitting curve which matches the motion trajectory of the patient. Third, the motion kernel is deconvolved with the initial dose distribution optimized for the stationary target to produce a dose distribution that is optimized in four-dimensions. This algorithm is tested with measured doses using a mobile phantom that moves with controlled motion patterns. Results: A motion-optimized dose distribution is obtained from the initial dose distribution of the stationary target by deconvolution with the motion-kernel of the mobile target. This motion-optimized dose distribution is equivalent to that optimized for the stationary target using IMRT. The motion-optimized and measured dose distributions are tested with the gamma index with a passing rate of >95% considering 3% dose-difference and 3mm distance-to-agreement. If the dose delivery per beam takes place over several respiratory cycles, then the spread-out of the dose distributions is only dependent on the motion amplitude and not affected by motion frequency and phase. This algorithm is limited to motion amplitudes that are smaller than the length of the target along the direction of motion. Conclusion: An algorithm is developed to optimize dose in 4D. Besides IMRT that provides optimal dose coverage for a stationary target, it extends dose optimization to 4D considering target motion. This algorithm provides alternative to motion management techniques such as beam-gating or breath-holding and has potential applications in adaptive radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-08: External and Internal Motion Assessments with Amplitude and Time Based Reconstruction and AveCT

Purpose: To investigate the effects of external surrogate and tumour motion by observing the reconstructed phases and AveCT in an Amplitude and Time based 4DCT. Methods: Based on patient motion studies, Cos6 and sinusoidal motions were simulated as external surrogate and tumour motions in a motion phantom. The diaphragm and tumour motions may or may not display the same waveform therefore the same and different waveforms were programmed into the phantom, scanned and reconstructed based on Amplitude and Time. The AveCT and phases were investigated with these different scenarios. The AveCT phantom images were also compared with CBCT phantom images programmed with the same motions. Results: For the same surrogate and tumour sin motions, the phases (Amplitude and Time) and AveCT indicated similar motions based on the position of the BB at the slice and displayed contrast values respectively. For cos6 motions, due to the varied time the tumour spends at each position, the Amplitude and Time based phases differed. The AveCT images represented the actual tumour motions and the Time and Amplitude based phases were represented by the surrogate with varied times. Conclusion: Different external surrogate and tumour motions may result in different displayed image motions when observing the AveCT and reconstructed phases. During the 4DCT, the surrogate motion is readily available for observation of the amplitude and time of the diaphragm position. Following image reconstruction, the user may need to observe the AveCT in addition to the reconstructed phases to comprehend the time weightings of the tumour motion during the scan. This may also apply to 3D CBCT images where the displayed tumour position in the images is influenced by the long duration of the CBCT. Knowledge of the tumour motion represented by the greyscale of the AveCT may also assist in CBCT treatment beam verification matching.

60 APPLIED LIFE SCIENCES↗

Example-Based Automatic Music-Driven Conventional Dance Motion Synthesis

We introduce a novel method for synthesizing dance motions that follow the emotions and contents of a piece of music. Our method employs a learning-based approach to model the music to motion mapping relationship embodied in example dance motions along with those motions' accompanying background music. A key step in our method is to train a music to motion matching quality rating function through learning the music to motion mapping relationship exhibited in synchronized music and dance motion data, which were captured from professional human dance performance. To generate an optimal sequence of dance motion segments to match with a piece of music, we introduce a constraint-based dynamic programming procedure. This procedure considers both music to motion matching quality and visual smoothness of a resultant dance motion sequence. We also introduce a two-way evaluation strategy, coupled with a GPU-based implementation, through which we can execute the dynamic programming process in parallel, resulting in significant speedup. To evaluate the effectiveness of our method, we quantitatively compare the dance motions synthesized by our method with motion synthesis results by several peer methods using the motions captured from professional human dancers' performance as the gold standard. We also conducted several medium-scale user studies to explore how perceptually our dance motion synthesis method can outperform existing methods in synthesizing dance motions to match with a piece of music. These user studies produced very positive results on our music-driven dance motion synthesis experiments for several Asian dance genres, confirming the advantages of our method.

99 GENERAL AND MISCELLANEOUS↗

Three-Dimensional Motion of Liver Tumors Using Cine-Magnetic Resonance Imaging

Purpose: To measure the three-dimensional motion of liver tumors using cine-magnetic resonance imaging (MRI) and compare it to the liver motion assessed using fluoroscopy. Methods and Materials: Liver and liver tumor motion were investigated in the first 36 patients with primary (n = 20) and metastatic (n = 16) liver cancer accrued to our Phase I stereotactic radiotherapy study. At simulation, all patients underwent anteroposterior fluoroscopy, and the maximal diaphragm excursion in the craniocaudal (CC) direction was observed. Cine-MRI using T{sub 2}-weighted single shot fast spin echo sequences were acquired in three orthogonal planes during free breathing through the centroid of the most dominant liver tumor. ImageJ software was used to measure the maximal motion of the tumor edges in each plane. The intra- and interobserver reproducibility was also quantified. Results: The average CC motion of the liver at fluoroscopy was 15 mm (range, 5-41). On cine-MRI, the average CC tumor motion was 15.5 mm (range, 6.9-35.4), the anteroposterior motion was 10 mm (range, 3.7-21.6), and the mediolateral motion was 7.5 mm (range, 3.8-14.8). The fluoroscopic CC diaphragm motion did not correlate well with the MRI CC tumor motion (r = 0.25). The mean intraobserver error was <2 mm in the CC, anteroposterior, and mediolateral directions, and 90% of measurements between observers were within 3 mm. Conclusions: The results of our study have shown that cine-MRI can be used to directly assess liver tumor motion in three dimensions. Tumor motion did not correlate well with the diaphragm motion measured using kilovoltage fluoroscopy. The tumor motion data from cine-MRI can be used to facilitate individualized planning target volume margins to account for breathing motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Assessment of Renal Motion in Children as Measured via Four-Dimensional Computed Tomography

Objectives: Abdominal intensity-modulated radiation therapy and proton therapy require quantification of target and organ motion to optimize localization and treatment. Although addressed in adults, there is no available literature on this issue in pediatric patients. We assessed physiologic renal motion in pediatric patients. Methods and Materials: Twenty free-breathing pediatric patients at a median age of 8 years (range, 2-18 years) with intra-abdominal tumors underwent computed tomography simulation and four-dimensional computed tomography acquisition (slice thickness, 3 mm). Kidneys and diaphragms were contoured during eight phases of respiration to estimate center-of-mass motion. We quantified center of kidney mass mobility vectors in three dimensions: anteroposterior (AP), mediolateral (ML), and superoinferior (SI). Results: Kidney motion decreases linearly with decreasing age and height. The 95% confidence interval for the averaged minima and maxima of renal motion in children younger than 9 years was 5-9 mm in the ML direction, 4-11 mm in the AP direction, and 12-25 mm in the SI dimension for both kidneys. In children older than 9 years, the same confidence interval reveals a widening range of motion that was 5-16 mm in the ML direction, 6-17 mm in the AP direction, and 21-52 mm in the SI direction. Although not statistically significant, renal motion correlated with diaphragm motion in older patients. The correlation between diaphragm motion and body mass index was borderline (r = 0.52, p = 0.0816) in younger patients. Conclusions: Renal motion is age and height dependent. Measuring diaphragmatic motion alone does not reliably quantify pediatric renal motion. Renal motion in young children ranges from 5 to 25 mm in orientation-specific directions. The vectors of motion range from 5 to 52 mm in older children. These preliminary data represent novel analyses of pediatric intra-abdominal organ motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-210-02: Impact of Intrafractional Motion On TomoTherapy Stereotactic Body Radiotherapy (SBRT) 4D Dosimetry

Purpose: TomoTherapy treatment has unique challenges in handling intrafractional motion compared to conventional LINAC. This study is aimed to gain a realistic and quantitative understanding of motion impact on TomoTherapy SBRT treatment of lung and prostate cancer patients. Methods: A 4D dose engine utilizing GPUs and including motion during treatment was developed for the efficient simulation of TomoTherapy delivered dosimetry. Two clinical CyberKnife lung cases with respiratory motion tracking and two prostate cases with a slower non-periodical organ motion treated by LINAC plus Calypso tracking were used in the study. For each disease site, one selected case has an average motion (6mm); the other has a large motion (10mm for lung and 15mm for prostate). SBRT of lung and prostate cases were re-planned on TomoTherapy with 12 Gyx4 fractions and 7Gyx5 fractions, respectively, all with 95% PTV coverage. Each case was planned with 4 jaw settings: 1) conventional 1cm static, 2) 2.5cm static, 3) 2.5cm dynamic, and 4) 5cm dynamic. The intrafractional rigid motion of the target was applied in the dose calculation of individual fractions of each plan and total dose was accumulated from multiple fractions. Results: For 1cm static jaw plans with motions applied, PTV coverage is related to motion type and amplitude. For SBRT patients with average motion (6mm), the PTV coverage remains > 95% for lung case and 74% for prostate case. For cases with large motion, PTV coverage drops to 61% for lung SBRT and 49% for prostate SBRT. Plans with other jaws improve uniformity of moving target, but still suffer from poor PTV coverage (< 70%). Conclusion: TomoTherapy lung SBRT is less motion-impacted when average amplitude of respiratory-induced intrafractional motion is present (6mm). When motion is large and/or non-periodic (prostate), all studied plans lead to significantly decreased target coverage in actual delivered dosimetry.

60 APPLIED LIFE SCIENCES↗

Validation of earthquake ground-motion models in southern California, USA, using precariously balanced rocks

Accurate estimates of earthquake ground shaking rely on uncertain ground-motion models derived from limited instrumental recordings of historical earthquakes. A critical issue is that there is currently no method to empirically validate the resultant ground-motion estimates of these models at the timescale of rare, large earthquakes; this lack of validation causes great uncertainty in ground-motion estimates. Here, we address this issue and validate ground-motion estimates for southern California utilizing the unexceeded ground motions recorded by 20 precariously balanced rocks. We used cosmogenic 10Be exposure dating to model the age of the precariously balanced rocks, which ranged from ca. 1 ka to ca. 50 ka, and calculated their probability of toppling at different ground-motion levels. With this rock data, we then validated the earthquake ground motions estimated by the Uniform California Earthquake Rupture Forecast, Version 3 (UCERF3) seismic-source characterization and the Next Generation Attenuation (NGA)-West2 ground-motion models. We found that no ground-motion model estimated levels of earthquake ground shaking consistent with the observed continued existence of all 20 precariously balanced rocks. The ground-motion model I14 estimated ground-motion levels that were inconsistent with the most rocks; therefore, I14 was invalidated and removed. At a 2475 year mean return period, the removal of this invalid ground-motion model resulted in a 2−7% reduction in the mean and a 10−36% reduction in the 5th−95th fractile uncertainty of the ground-motion estimates. Our findings demonstrate the value of empirical data from precariously balanced rocks as a validation tool for removing invalid ground-motion models and, in turn, reducing the uncertainty in earthquake ground-motion estimates.

Geology↗

Effect of Soil Properties and Input Motion on Site Amplification Using Validated Nonlinear Soil Model

Here, three-dimensional (3-D) nonlinear site response analyses are conducted using finite element models of actual soil profiles from ten nuclear power plant (NPP) sites in the United States to investigate the effects of soil properties and input motions on site amplification. The modeling approach developed in this study combines several novel elements, such as 3-D analysis (including vertical motions), nonlinear inelastic behavior of soil (strain-dependent shear modulus reduction and hysteretic damping), formulation of nonreflecting boundary conditions at the base, and generation of realistic outcrop ground motions for specific sites. All these elements of the modeling approach are first validated using actual data from five earthquakes at three downhole array stations recorded in the Kiban-Kyoshin network (KiK-net), Japan. The same approach is then used to develop site models of ten NPP sites in the United States and corresponding ground motions that are spectrally matched to the site hazard spectra. Eight sets of three-component input motions are used in the study and are categorized on the basis of presence or absence of a near-field pulse in the seed ground motions used for spectral matching. It is found that all sites retain a definite site amplification function regardless of the input motion, provided that the seed motion is spectrally matched to the site hazard spectra. The magnitude of site amplification and frequencies at which they occur depend upon soil properties, particularly the shear wave velocity profile and the constitutive relationship (strain-dependent shear modulus reduction and hysteretic damping) of soil. Amplification of spectral acceleration in the vertical direction (up-down motion) is found to be just as much as, if not more than, the amplification in the horizontal direction. Peak shear strain is found to be about 20% larger for near-field motions compared to far-field motions whereas maximum horizontal site amplification for far-field motions is found to be consistently larger than that of near-field motions, even though the differences between the two remain within the scatter resulting from individual ground motions.

99 GENERAL AND MISCELLANEOUS↗

Characterization of free breathing patterns with 5D lung motion model

Purpose: To determine the quiet respiration breathing motion model parameters for lung cancer and nonlung cancer patients. Methods: 49 free breathing patient 4DCT image datasets (25 scans, cine mode) were collected with simultaneous quantitative spirometry. A cross-correlation registration technique was employed to track the lung tissue motion between scans. The registration results were applied to a lung motion model: X-vector=X-vector{sub 0}+{alpha}-vector{beta}-vector f, where X-vector is the position of a piece of tissue located at reference position X-vector{sub 0} during a reference breathing phase (zero tidal volume v, zero airflow f). {alpha}-vector is a parameter that characterizes the motion due to air filling (motion as a function of tidal volume v) and {beta}-vector is the parameter that accounts for the motion due to the imbalance of dynamical stress distributions during inspiration and exhalation that causes lung motion hysteresis (motion as a function of airflow f). The parameters {alpha}-vector and {beta}-vector together provide a quantitative characterization of breathing motion that inherently includes the complex hysteresis interplay. The {alpha}-vector and {beta}-vector distributions were examined for each patient to determine overall general patterns and interpatient pattern variations. Results: For 44 patients, the greatest values of |{alpha}-vector| were observed in the inferior and posterior lungs. For the rest of the patients, |{alpha}-vector| reached its maximum in the anterior lung in three patients and the lateral lung in two patients. The hysteresis motion {beta}-vector had greater variability, but for the majority of patients, |{beta}-vector| was largest in the lateral lungs. Conclusions: This is the first report of the three-dimensional breathing motion model parameters for a large cohort of patients. The model has the potential for noninvasively predicting lung motion. The majority of patients exhibited similar |{alpha}-vector| maps and the |{beta}-vector| maps showed greater interpatient variability. The motion parameter interpatient variability will inform our need for custom radiation therapy motion models. The utility of this model depends on the parameter stability over time, which is still under investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of interpolation methods for surface-based motion compensated tomographic reconstruction for cardiac angiographic C-arm data

Purpose: For interventional cardiac procedures, anatomical and functional information about the cardiac chambers is of major interest. With the technology of angiographic C-arm systems it is possible to reconstruct intraprocedural three-dimensional (3D) images from 2D rotational angiographic projection data (C-arm CT). However, 3D reconstruction of a dynamic object is a fundamental problem in C-arm CT reconstruction. The 2D projections are acquired over a scan time of several seconds, thus the projection data show different states of the heart. A standard FDK reconstruction algorithm would use all acquired data for a filtered backprojection and result in a motion-blurred image. In this approach, a motion compensated reconstruction algorithm requiring knowledge of the 3D heart motion is used. The motion is estimated from a previously presented 3D dynamic surface model. This dynamic surface model results in a sparse motion vector field (MVF) defined at control points. In order to perform a motion compensated reconstruction, a dense motion vector field is required. The dense MVF is generated by interpolation of the sparse MVF. Therefore, the influence of different motion interpolation methods on the reconstructed image quality is evaluated. Methods: Four different interpolation methods, thin-plate splines (TPS), Shepard's method, a smoothed weighting function, and a simple averaging, were evaluated. The reconstruction quality was measured on phantom data, a porcine model as well as on in vivo clinical data sets. As a quality index, the 2D overlap of the forward projected motion compensated reconstructed ventricle and the segmented 2D ventricle blood pool was quantitatively measured with the Dice similarity coefficient and the mean deviation between extracted ventricle contours. For the phantom data set, the normalized root mean square error (nRMSE) and the universal quality index (UQI) were also evaluated in 3D image space. Results: The quantitative evaluation of all experiments showed that TPS interpolation provided the best results. The quantitative results in the phantom experiments showed comparable nRMSE of Almost-Equal-To 0.047 {+-} 0.004 for the TPS and Shepard's method. Only slightly inferior results for the smoothed weighting function and the linear approach were achieved. The UQI resulted in a value of Almost-Equal-To 99% for all four interpolation methods. On clinical human data sets, the best results were clearly obtained with the TPS interpolation. The mean contour deviation between the TPS reconstruction and the standard FDK reconstruction improved in the three human cases by 1.52, 1.34, and 1.55 mm. The Dice coefficient showed less sensitivity with respect to variations in the ventricle boundary. Conclusions: In this work, the influence of different motion interpolation methods on left ventricle motion compensated tomographic reconstructions was investigated. The best quantitative reconstruction results of a phantom, a porcine, and human clinical data sets were achieved with the TPS approach. In general, the framework of motion estimation using a surface model and motion interpolation to a dense MVF provides the ability for tomographic reconstruction using a motion compensation technique.

60 APPLIED LIFE SCIENCES↗

TU-F-17A-03: An Analytical Respiratory Perturbation Model for Lung Motion Prediction

Purpose: Breathing irregularity is common, causing unreliable prediction in tumor motion for correlation-based surrogates. Both tidal volume (TV) and breathing pattern (BP=ΔVthorax/TV, where TV=ΔVthorax+ΔVabdomen) affect lung motion in anterior-posterior and superior-inferior directions. We developed a novel respiratory motion perturbation (RMP) model in analytical form to account for changes in TV and BP in motion prediction from simulation to treatment. Methods: The RMP model is an analytical function of patient-specific anatomic and physiologic parameters. It contains a base-motion trajectory d(x,y,z) derived from a 4-dimensional computed tomography (4DCT) at simulation and a perturbation term Δd(ΔTV,ΔBP) accounting for deviation at treatment from simulation. The perturbation is dependent on tumor-specific location and patient-specific anatomy. Eleven patients with simulation and treatment 4DCT images were used to assess the RMP method in motion prediction from 4DCT1 to 4DCT2, and vice versa. For each patient, ten motion trajectories of corresponding points in the lower lobes were measured in both 4DCTs: one served as the base-motion trajectory and the other as the ground truth for comparison. In total, 220 motion trajectory predictions were assessed. The motion discrepancy between two 4DCTs for each patient served as a control. An established 5D motion model was used for comparison. Results: The average absolute error of RMP model prediction in superior-inferior direction is 1.6±1.8 mm, similar to 1.7±1.6 mm from the 5D model (p=0.98). Some uncertainty is associated with limited spatial resolution (2.5mm slice thickness) and temporal resolution (10-phases). Non-corrected motion discrepancy between two 4DCTs is 2.6±2.7mm, with the maximum of ±20mm, and correction is necessary (p=0.01). Conclusion: The analytical motion model predicts lung motion with accuracy similar to the 5D model. The analytical model is based on physical relationships, requires no training, and therefore is potentially more resilient to breathing irregularities. On-going investigation introduces airflow into the RMP model for improvement. This research is in part supported by NIH (U54CA137788/132378). AY would like to thank MSKCC summer medical student research program supported by National Cancer Institute and hosted by Department of Medical Physics at MSKCC.

60 APPLIED LIFE SCIENCES↗