Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo approximation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

Monte Carlo Neutronics Analysis of the SNS STS Monolith

The neutronics analysis for the Oak Ridge National Laboratory’s Spallation Neutron Source second target station monolith conceptual design was performed entirely with the Monte Carlo method. It has been demonstrated that even though the monolith provides approximately peta-scale attenuation of the dose rates, Monte Carlo simulations are within reach of computing capabilities of relatively inexpensive Linux clusters. Several monolith configurations achieved or exceeded design requirements and provide basis for the final design.

Remec, Igor↗

Calculation of Nonlinear Thermoelectric Coefficients of InAs1-xSbx Using Monte Carlo Method

It was found that the nonlinear Peltier effect could take place and increase the cooling power density when a lightly doped thermoelectric material is under a large electrical field. This effect is due to the Seebeck coefficient enhancement from an electron distribution far from equilibrium. In the nonequilibrium transport regime, the solution of the Boltzmann transport equation in the relaxation-time approximation ceases to apply. The Monte Carlo method, on the other hand, proves to be a capable tool for simulation of semiconductor devices at small scales as well as thermoelectric effects with local nonequilibrium charge distribution. InAs1-xSb is a favorable thermoelectric material for nonlinear operation owing to its high mobility inherited from the binary compounds InSb and InAs. In this work we report simulation results on the nonlinear Peltier power of InAs1-xSb at low doping levels, at room temperature and at low temperatures. The thermoelectric power factor in nonlinear operation is compared with the maximum value that can be achieved with optimal doping in the linear transport regime.

Sadeghian, RB↗

TU-EF-304-03: 4D Monte Carlo Robustness Test for Proton Therapy

Purpose: Breathing motion and approximate dose calculation engines may increase proton range uncertainties. We address these two issues using a comprehensive 4D robustness evaluation tool based on an efficient Monte Carlo (MC) engine, which can simulate breathing with no significant increase in computation time. Methods: To assess the robustness of the treatment plan, multiple scenarios of uncertainties are simulated, taking into account the systematic and random setup errors, range uncertainties, and organ motion. Our fast MC dose engine, called MCsquare, implements optimized models on a massively-parallel computation architecture and allows us to accurately simulate a scenario in less than one minute. The deviations of the uncertainty scenarios are then reported on a DVH-band and compared to the nominal plan.The robustness evaluation tool is illustrated in a lung case by comparing three 60Gy treatment plans. First, a plan is optimized on a PTV obtained by extending the CTV with an 8mm margin, in order to take into account systematic geometrical uncertainties, like in our current practice in radiotherapy. No specific strategy is employed to correct for tumor and organ motions. The second plan involves a PTV generated from the ITV, which encompasses the tumor volume in all breathing phases. The last plan results from robust optimization performed on the ITV, with robustness parameters of 3% for tissue density and 8 mm for positioning errors. Results: The robustness test revealed that the first two plans could not properly cover the target in the presence of uncertainties. CTV-coverage (D95) in the three plans ranged respectively between 39.4–55.5Gy, 50.2–57.5Gy, and 55.1–58.6Gy. Conclusion: A realistic robustness verification tool based on a fast MC dose engine has been developed. This test is essential to assess the quality of proton therapy plan and very useful to study various planning strategies for mobile tumors. This work is partly funded by IBA (Louvain-la-Neuve, Belgium)

60 APPLIED LIFE SCIENCES↗

Imaginary time correlations and the phaseless auxiliary field quantum Monte Carlo

The phaseless Auxiliary Field Quantum Monte Carlo (AFQMC) method provides a well established approximation scheme for accurate calculations of ground state energies of many-fermions systems. Here we address the possibility of calculating imaginary time correlation functions with the phaseless AFQMC. We give a detailed description of the technique and test the quality of the results for static properties and imaginary time correlation functions against exact values for small systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Particle filtering with path sampling and an application to a bimodal ocean current model

This paper introduces a recursive particle filtering algorithm designed to filter high dimensional systems with complicated non-linear and non-Gaussian effects. The method incorporates a parallel marginalization (PMMC) step in conjunction with the hybrid Monte Carlo (HMC) scheme to improve samples generated by standard particle filters. Parallel marginalization is an efficient Markov chain Monte Carlo (MCMC) strategy that uses lower dimensional approximate marginal distributions of the target distribution to accelerate equilibration. As a validation the algorithm is tested on a 2516 dimensional, bimodal, stochastic model motivated by the Kuroshio current that runs along the Japanese coast. The results of this test indicate that the method is an attractive alternative for problems that require the generality of a particle filter but have been inaccessible due to the limitations of standard particle filtering strategies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A molecular-field approximation for quantum crystals

Ground-state properties of quantum crystals have received considerable attention from both theorists and experimentalists. The theoretical results have varied widely with the Monte Carlo calculations being the most successful. The molecular field approximation yields ground-state properties which agree closely with the Monte Carlo results. This approach evaluates the dynamical behavior of each pair of molecules in the molecular field of the other N-2 molecules. In addition to predicting ground-state properties that agree well with experiment, this approach yields data on the relative importance of interactions of different nearest neighbor pairs.

Danilowicz, R.↗

On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations

The purpose of this work was to investigate the applicability and appropriateness of Monte Carlo-derived normalized data to provide accurate estimations of patient dose from computed tomography (CT) exposures. Monte Carlo methodology and mathematical anthropomorphic phantoms were used to simulate standard patient CT examinations of the head, thorax, abdomen, and trunk performed on a multislice CT scanner. Phantoms were generated to simulate the average adult individual and two individuals with different body sizes. Normalized dose values for all radiosensitive organs and normalized effective dose values were calculated for standard axial and spiral CT examinations. Discrepancies in CT dosimetry using Monte Carlo-derived coefficients originating from the use of: (a) Conversion coefficients derived for axial CT exposures, (b) a mathematical anthropomorphic phantom of standard body size to derive conversion coefficients, and (c) data derived for a specific CT scanner to estimate patient dose from CT examinations performed on a different scanner, were separately evaluated. The percentage differences between the normalized organ dose values derived for contiguous axial scans and the corresponding values derived for spiral scans with pitch=1 and the same total scanning length were up to 10%, while the corresponding percentage differences in normalized effective dose values were less than 0.7% for all standard CT examinations. The normalized organ dose values for standard spiral CT examinations with pitch 0.5-1.5 were found to differ from the corresponding values derived for contiguous axial scans divided by the pitch, by less than 14% while the corresponding percentage differences in normalized effective dose values were less than 1% for all standard CT examinations. Normalized effective dose values for the standard contiguous axial CT examinations derived by Monte Carlo simulation were found to considerably decrease with increasing body size of the mathematical phantom used. When the body-mass index was increased from 23.0 to 32.7 kg/m{sup 2} discrepancies in patient effective dose were up to 34%. The error in estimating effective dose from a CT exposure performed on a specific CT scanner using Monte Carlo data derived for a different CT scanner was estimated to be up to 25%. A simple method was proposed and validated for the determination of scanner-specific normalized dosimetric data from data derived from Monte Carlo simulation of a specific scanner. In conclusion, computed tomography dose index (CTDI) to effective dose conversion coefficients derived by Monte Carlo simulation of axial CT scans may provide a good approximation of corresponding coefficients applicable in helical scans. However, the use of Monte Carlo conversion coefficients for the estimation of patient dose from a CT examination involves a remarkable inaccuracy when the body size of the mathematical anthropomorphic phantom used in Monte Carlo simulation differs from the body of the patient. Therefore, separate sets of Monte Carlo dosimetric CT data shall be generated for different patient body sizes. Besides calculation of different sets of Monte Carlo data for each commercially available scanner is not necessary, since scanner specific data may be derived with acceptable accuracy from the Monte Carlo data calculated for a specific scanner appropriately modified for the different CTDI{sub w}/CTDI{sub air} ratio.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast mix table construction for material discretization

An effective hybrid Monte Carlo-deterministic implementation typically requires the approximation of a continuous geometry description with a discretized piecewise-constant material field. The inherent geometry discretization error can be reduced somewhat by using material mixing, where multiple materials inside a discrete mesh voxel are homogenized. Material mixing requires the construction of a 'mix table,' which stores the volume fractions in every mixture so that multiple voxels with similar compositions can reference the same mixture. Mix table construction is a potentially expensive serial operation for large problems with many materials and voxels. We formulate an efficient algorithm to construct a sparse mix table in O(number of voxels x log number of mixtures) time. The new algorithm is implemented in ADVANTG and used to discretize continuous geometries onto a structured Cartesian grid. When applied to an end-of-life MCNP model of the High Flux Isotope Reactor with 270 distinct materials, the new method improves the material mixing time by a factor of 100 compared to a naive mix table implementation. (authors)

97 MATHEMATICS AND COMPUTING↗

Study of beyond nearest-neighbor environment and intermediate-range order in a sodium aluminosilicate geopolymer using Reverse Monte Carlo modeling

A large scale three-dimensional structural model of a geopolymer with an approximate composition of NaAlSi 2 O 6 .5.5H 2 O obtained by Reverse Monte Carlo (RMC) modeling based on experimental high-energy x-ray diffraction is presented for the first time in order to obtain information regarding beyond nearest-neighbor environment and intermediate-range order (IRO). RMC model exhibits a three-dimensional network consisting of randomly cross-linked AlO 4 and SiO 4 tetrahedral units with uniformly distributed Na atoms and H 2 O molecules. The bond angle distributions, i.e. T-O-T, O-T-O and Na-O-Na angles, are somewhat distorted with lower values compared to analogous crystal systems. The origin of the first peak in the structure factor indicating IRO is investigated using the partial structure factors; Na-Na, Si-Na, Al-Si, O-H, and H-H atom pairs are found to be the main contributors. Ring size distribution analysis demonstrates that the structure mainly involves 6-, 7- and 8-membered rings. Finally, the coherence length of these IRO characteristics is ~10.3 Å.

36 MATERIALS SCIENCE↗

Analytical Green's function of the radiative transfer radiance for the infinite medium

An analytical solution of the radiative transfer equation for the radiance caused by an isotropic source which is located in an infinitely extended medium was derived using the P{sub N} method. The results were compared with Monte Carlo simulations and excellent agreement was found. In addition, the radiance of the SP{sub N} approximation for the same geometry was derived. Comparison with Monte Carlo simulations showed that the SP{sub N} radiance, although being more exact than the radiance derived from diffusion theory, has relatively large errors in many relevant cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spin ice in a field: Quasi-phases and pseudo-transitions

Thermodynamics of a short-range model of spin ice magnets in a field is considered in the Bethe-Peierls approximation. The results obtained for [111], [100], and [011] fields agree reasonably well with the existing Monte Carlo simulations and some experiments. In this approximation, all extremely sharp field-induced anomalies are described by analytic functions of temperature and the applied field. In spite of the absence of true phase transitions, the analysis of the entropy and specific heat reliefs over the H-T plane allows discerning 'pseudo-phases' with a specific character of spin fluctuations and defining the lines of relatively sharp 'pseudo-transitions' between them.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transient behavior of drift and ionization in atmospheric pressure nitrogen discharge

The fluid models are frequently used to describe a non-thermal plasma such as a streamer discharge. The required electron transport data and rate coefficients for the fluid model are parametrized using the local field approximation (LFA) in first order models and the local-mean-energy approximation (LMEA) in second order models. We performed Monte Carlo simulations in Nitrogen gas with step changes in the E/N (reduced electric field) to study the behavior of the transport properties in the transient phase. During the transient phase of the simulation, we extract the instantaneous electron mean energy, which is different from the steady state mean electron energy, and the corresponding transport parameters and rate coefficients. Our results indicate that the mean electron energy is not a suitable parameter for mobility/drift of electrons due to big difference in momentum relaxation and energy relaxation. Furthermore, the high energy threshold rates such as ionization show a strong correlation to mean electron energy. In second order models where the energy-balance equation is solved, we suggest that it would rather be appropriate to use the local electric field to find electron drift velocity in gases such as Nitrogen and the local mean electron energy to determine the ionization and excitation rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80 to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with a residual 2.1% coefficient of variation (COV) over the 80-150-kVp energy range. Monte Carlo corrections reduced the COV to 1.4% over this energy range. All PDD measurements were in good agreement with one another except for the uncorrected PSD data, in which an over-response was observed with depth (13% at 10 cm with a 100 kVp beam), showing that beam hardening had a non-negligible effect on the PSD response. A correction based on LCT compensated very well for this effect, reducing the over-response to 3%.Conclusion: In the diagnostic energy range, PSDs show high-energy dependence, which can be corrected using spectra-weighted mass energy-absorption coefficients, showing no considerable sign of quenching between these energies. Correction factors obtained by Monte Carlo simulations confirm that the approximations made by LCT corrections are valid. Thus, PSDs could be useful for real-time dosimetry in radiology applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An improved physics-based approach for unfolding megavoltage bremsstrahlung spectra using transmission analysis

Purpose: To develop a physics-based approach to improve the accuracy and robustness of the ill-conditioned problem of unfolding megavoltage bremsstrahlung spectra from transmission data. Methods: Spectra are specified using a rigorously-benchmarked functional form. Since ion chambers are the typical detector used in transmission measurements, the energy response of a Farmer chamber is calculated using the EGSnrc Monte Carlo code, and the effect of approximating the energy response on the accuracy of the unfolded spectra is studied. A proposal is introduced to enhance spectral sensitivity by combining transmission data measured with multiple detectors of different energy response and by combining data from multiple attenuating materials. Monte Carlo methods are developed to correct for nonideal exponential attenuation (e.g., scatter effects and secondary attenuation). The performance of the proposed methods is evaluated for a diverse set of validated clinical spectra (3.5-25 MV) using analytical transmission data with simulated experimental noise. Results: The approximations commonly used in previous studies for the ion-chamber energy response lead to significant errors in the unfolded spectra. Of the configurations studied, the one with best spectral sensitivity is to measure four full transmission curves using separate low-Z and high-Z attenuators in conjunction with two detectors of different energy response (the authors propose a Farmer-type ion chamber, once with a low-Z, and once with a high-Z buildup cap material), then to feed the data simultaneously to the unfolding algorithm. Deviations from ideal exponential attenuation are as much as 1.5% for the smallest transmission signals, and the proposed methods properly correct for those deviations. The transmission data with enhanced spectral sensitivity, combined with the accurate and flexible spectral functional form, lead to robust unfolding without requiring a priori knowledge of the spectrum. Compared with the commonly-used methods, the accuracy is improved for the unfolded spectra and for the unfolded mean incident electron kinetic energy by at least factors of three and four, respectively. With simulated experimental noise and a lowest transmission of 1%, the unfolded energy fluence spectra agree with the original spectra with a normalized root-mean-square deviation, %{Delta}({psi}), of 2.3%. The unfolded mean incident electron kinetic energies agree, on average, with the original values within 1.4%. A lowest transmission of only 10% still allows unfolding with %{Delta}({psi}) of 3.3%. Conclusions: In the presence of realistic experimental noise, the proposed approach significantly improves the accuracy and robustness of the spectral unfolding problem for all therapy and MV imaging beams of clinical interest.

61 RADIATION PROTECTION AND DOSIMETRY↗

Forward and inverse uncertainty quantification using multilevel Monte Carlo algorithms for an elliptic non-local equation

Our paper considers uncertainty quantification for an elliptic nonlocal equation. In particular, it is assumed that the parameters which define the kernel in the nonlocal operator are uncertain and a priori distributed according to a probability measure. It is shown that the induced probability measure on some quantities of interest arising from functionals of the solution to the equation with random inputs is well-defined,s as is the posterior distribution on parameters given observations. As the elliptic nonlocal equation cannot be solved approximate posteriors are constructed. The multilevel Monte Carlo (MLMC) and multilevel sequential Monte Carlo (MLSMC) sampling algorithms are used for a priori and a posteriori estimation, respectively, of quantities of interest. Furthermore, these algorithms reduce the amount of work to estimate posterior expectations, for a given level of error, relative to Monte Carlo and i.i.d. sampling from the posterior at a given level of approximation of the solution of the elliptic nonlocal equation.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo methods and their analysis for Coulomb collisions in multicomponent plasmas

Highlights: •A general approach to Monte Carlo methods for multicomponent plasmas is proposed. •We show numerical tests for the two-component (electrons and ions) case. •An optimal choice of parameters for speeding up the computations is discussed. •A rigorous estimate of the error of approximation is proved. -- Abstract: A general approach to Monte Carlo methods for Coulomb collisions is proposed. Its key idea is an approximation of Landau–Fokker–Planck equations by Boltzmann equations of quasi-Maxwellian kind. It means that the total collision frequency for the corresponding Boltzmann equation does not depend on the velocities. This allows to make the simulation process very simple since the collision pairs can be chosen arbitrarily, without restriction. It is shown that this approach includes the well-known methods of Takizuka and Abe (1977) [12] and Nanbu (1997) as particular cases, and generalizes the approach of Bobylev and Nanbu (2000). The numerical scheme of this paper is simpler than the schemes by Takizuka and Abe [12] and by Nanbu. We derive it for the general case of multicomponent plasmas and show some numerical tests for the two-component (electrons and ions) case. An optimal choice of parameters for speeding up the computations is also discussed. It is also proved that the order of approximation is not worse than O(√(ε)), where ε is a parameter of approximation being equivalent to the time step Δt in earlier methods. A similar estimate is obtained for the methods of Takizuka and Abe and Nanbu.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗