Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Minnesota”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

State Strategies to Bring Solar to Low- and Moderate-Income Communities

This Final Technical Report describes the goals, objectives, activities, results, and accomplishments of the State Strategies to Bring Solar to Low- and Moderate-Income Communities Project, managed by the Clean Energy States Alliance. This project enabled five states (Connecticut, Minnesota, New Mexico, Oregon, and Rhode Island) and the District of Columbia to develop and implement strategies for expanding market penetration of solar PV among LMI residents and communities. The project disseminated successful strategies and lessons learned from those states to other states and stakeholders across the country.

14 SOLAR ENERGY↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prototyping a self-learning digital twin platform for personalized treatment in melanoma patients (Final Report)

We completed all the Milestones and disseminated results at the 2021 Computational Approaches for Cancer Workshop (CAFCW21) at the SuperComputing21 conference. As part of Milestone 1, we developed and implemented a prototype digital twin of metastatic melanoma patients, performed quality checks on the code and released it as open source. The work has directly driven major grant proposals by the team on computational digital twins and supporting software infrastructure, including a successful fellowship application by the PI. Work was lead by Paul Macklin (Contact PI, Indiana University), in collaboration with Ilya Shmulevich (PI, Institute for Systems Biology), Tina Hernandez-Boussard (PI, Stanford Univ.), Jeffrey Bryan (Co-I, University of Missouri), Snigdhansu Chatterjee (Co-I, University of Minnesota), and Mohammad Fallahi-Sichani (Co-I, U. of Virginia). Postdoctoral student Heber L. Rocha (Macklin lab, IU) performed intensive computational work, in collaboration with Senior Research Scientist Boris Aguilar (Shmulevich lab, ISB).

59 BASIC BIOLOGICAL SCIENCES↗

Affordable Solid Panel "Perfect Wall" System

The SPS is an innovative interpretation of the “perfect wall” concept, in which environmental control layers are located on the exterior side of the structural components, as opposed to traditional cavity insulated, stud-framed walls. The primary objective of this study is to validate the SPS technology in terms of its constructability, cost, and performance. Specifically for this project, we partnered with two affordable housing nonprofits in Minnesota—Twin Cities Habitat for Humanity and Urban Homeworks—to build five new houses using SPS walls, as well as two high-performance stud-framed comparison homes. We also reviewed cost and performance data from 13 SPS homes built prior to this project by MonoPath and Spero Environmental Builders. Reviewing the outcomes of these 20 homes total, we find promising results in terms of constructability, cost, and performance, although more structural performance data are needed before this new technology can see widespread adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interactions between molecular-scale processes and hyporheic exchange for understanding Fe-S-C cycling in riparian wetlands (Final Report)

Wetlands represent some of the most productive ecosystems on the planet and critically influence global environmental health. Specifically, wetlands promote water quality by transforming nutrients and organic compounds and sequestering metals and contaminants. Riparian wetland hyporheic zones, where toxic surface water and anoxic groundwater mix, exhibit dynamic conditions that drive steep redox gradients and promote hotspots of diverse and fluctuating microbial activity. Changes in climate, water quality, and water quantity can disturb hydrologic flow and biogeochemical processing in these environments. Understanding how sulfate loading, impacted by hydrologic flux and anthropogenic inputs, influences iron and carbon cycling in wetlands will be crucial for predicting water quality issues driven by iron mineral precipitation and sorption, such as the release of heavy metals and other toxic elements. We used a fully integrated multi-scale and multi-method approach to develop a mechanistic understanding of how hydrologic flow influences coupled iron and sulfur cycles in riparian wetlands. This entailed hydrological, geochemical, and microbial observations at two locations: an anthropogenic sulfate-impacted riparian wetland in northern Minnesota, and a low-sulfate Fe-rich riparian wetland in Tims Branch at the Savannah River Site (SRS). These sites were characterized by hydrologically dynamic conditions where the stream and wetland systems oscillated between gaining (upward flow) and losing (downward flow) conditions that recharged the system occasionally with oxidants that fueled a variety of biogeochemical reactions. Aqueous geochemical measurements of surface water, groundwater, and porewater samples were made alongside solid-phase geochemical analyses of sediment gravity cores. Bulk X-ray absorption spectroscopy at the Advanced Photon Source (APS; Argonne) interrogated the speciation and distribution of Fe and S mineral phases of the sediments. Interestingly, it was discovered that, despite strongly reducing conditions, Fe(III) compounds and a variety of intermediate valence S compounds were stable in the subsurface. Indeed, compounds like thiosulfate, S(0), and intermediate valence organosulfur compounds were more prevalent than FeS and pyrite. The composition of the sediments did change with changes in hydrologic flow, showing their reactivity in changing redox conditions. The abundance of these intermediate S compounds was likely formed as a result of anaerobic oxidation by aqueous and solid-phase Fe(III) compounds, fueling a cryptic S cycle that is driving the breakdown of organic matter in the hyporheic zone. Microbiome surveys showed a core community that seemed stable across the landscape, but changed with increasing depth into the sediment. The community composition did not seem to change dramatically with changes in season or hydrologic flow, except for some organisms that have the potential to contribute to S cycling. More work is needed to confirm their functional activity. These fine process-scale analyses were placed within a dynamic field context using physical flow parameters from surface water and groundwater level measurements. These data helped shed light on sulfur-driven biogeochemical processes in hydrologically dynamic riparian wetlands, addressing a gap in our understanding about the impacts of pollution and other anthropogenic changes on ecologically sensitive environments.

54 ENVIRONMENTAL SCIENCES↗

2021 NIRT Mini Drill (After Action Report)

During the summer and fall of 2021, several functional area drills were held that focused on exercising Consequence Management’s (CM) ability to extract and use data from RadResponder for the purpose of answering intermediate-phase questions presented as technical inject requests for information (RFI) in Sandia National Laboratories (SNL) Consequence Management Operational System (COSMOS) software. The scenario chosen was that of Northern Lights 2016 (NL16) which was a large-scale nuclear power plant (NPP) release exercise in the state of Minnesota. The NL16 data was extracted from the Radiological Assessment and Monitoring System (RAMS) event where it was created and was reformatted for implanting to a new RadResponder event. Next, the beta-version of a laboratory sample data simulator was used to generate more sample data that was injected to the event. Five “mini-drills” were devised with each prompt defined by a data-based need. For each drill, a team of assessment and NARAC scientists worked the problem using the drill prompt and the available data in RadResponder. The teams held a kickoff meeting, had several days to work the problem, and then reported their results as well as observations in a hotwash. Several areas for improvement in both the software and process were identified during the course of these drills. This report will document the process of addressing each RFI and the discovered gaps in both software capability and methodology so that they can be considered for future development and investment by the CM and NIRT programs.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Grid-Scale, Long-Term Energy Storage: Repurposing Hydrocarbon Reservoirs, Resources, and Infrastructure to Store CO 2 and Heat (Mid-Project Progress Report)

The purpose of this project is to create a viable business case for CO 2 capture, use, and storage (CCUS) by enabling grid-scale, long-term energy storage in mature hydrocarbon reservoirs and saline aquifers. Our CCUS approach, called the Earth Battery, is based on patents issued to Lawrence Livermore National Laboratory on Multi-Fluid Geo-Energy and Earth Battery Systems and to the University of Minnesota and TerraCOH, Inc. on CO 2 Plume Geothermal (CPG). Excess energy can be used to compress and store CO 2 and hot brine underground in permeable formations, including: (1) saline aquifers suitable for geologic CO 2 storage (GCS) and (2) hydrocarbon reservoirs, the focus of this project featuring a pilot test in a mature oil and natural gas (NG) field. Excess energy can come in the form of excess electricity from the grid or excess NG that does not have a market. It can also come in the form of excess heat from other sources, such as from the heat of air or CO 2 compression or from a nearby base-load power plant or solar thermal energy (STE) facility, when heat is not needed to generate electricity from those sources.

15 GEOTHERMAL ENERGY↗

Plant and shrub tissue decompositions in changing environments after six-years in a Peatland ecosystem

SPRUCE, Spruce and Peatland Responses Under Changing Environments, is a ten-year long ecosystem manipulation that tests the responses of a high-carbon peatland ecosystem to warming and elevated CO2. This experiment is located a Northern Minnesota peatland. Here we studied how plant tissue decomposition is affected by the climate treatments at SPRUCE. Six different litter types were placed into mesh bags and deployed into the peatland. The samples were then removed after six years, and we analyzed those samples in the laboratory. Analysis of these samples consisted of removing foreign growth, drying each sample, weighing each litter bag, grinding into a fine powder, and finally sending each sample off for phosphorus, carbon, and nitrogen analysis. Although we expected to observe effects of warming on decomposition rates, with faster decomposition in the warmer treatments, we only observed faster decomposition in the warmer plots in a few litter types.

54 ENVIRONMENTAL SCIENCES↗

Duluth Transit Authority Battery-Electric Bus Evaluation

Duluth Transit Authority (DTA) collaborated with the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to evaluate a fleet of seven battery-electric buses (BEBs) in revenue service in Duluth, Minnesota. The focus of the evaluation was to compare performance and cost of the BEBs to that of conventional technology buses in similar service and track progress over time. DTA enlisted the help of the Center for Transportation and the Environment (CTE) to manage the project and provide technical services with the BEB fleet and infrastructure. This report summarizes the results of the BEB evaluation and contains a combination of analyses performed by NREL and by CTE during the overall data collection period of December 2018 through February 2022.

33 ADVANCED PROPULSION SYSTEMS↗

Wall Upgrades for Energy Retrofits: A Techno-Economic Study

Homes built before 1992, when the U.S. Department of Energy’s (DOE) Building Energy Codes Program was established, represent approximately 68% of the residential building stock in the country. Up to 43% of these homes have little to no insulation in the walls and have very high air leakage rates of 10 or more air changes per hour at 50 pascals of pressure (ACH50). These issues can represent a substantial portion of unnecessary money spent on utility bills for homeowners, especially in the colder climates. There is a significant need for cost-effective, reliable retrofit methods for these homes that include air, moisture, and vapor controls which are considered best practices for high-performance new home construction. Well-tested and documented wall retrofit systems can help to achieve substantial energy savings and also improve durability, comfort, health, and resilience. In 2018, DOE’s Building Technologies Office awarded Pacific Northwest National Laboratory, Oak Ridge National Laboratory, and the University of Minnesota funding to complete a 3-year project to compare a range of residential wall retrofit systems that prioritized affordability, durability and energy savings potential. In addition to these core criteria, the ease-of-construction and the wide-scale applicability of the solutions also were considered. In this project, the research team identified, constructed, tested, simulated, and analyzed the feasibility and economics of 16 wall retrofit assemblies (14 test configurations and two baseline configurations).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gene regulatory networks controlling carbohydrate selective deconstruction pathways in fungi

The work performed at Clark University (PI, David Hibbett) was a subcomponent of the research lead by Jonathan Schilling at University of Minnesota (award number DE-SC0019427). The overall goal of this project was to address how fungi metabolize lignocellulose. Specifically, we targeted a carbohydrate-selective group of fungi known as 'brown rot' fungi that are well-aligned to be harness for bioconversion to biofuels and other products. These organisms orchestrate a two-step mechanism that initiates decomposition using oxidative radical-based chemistry and follows with enzymatic attack. We have helped characterize that this mechanism occurs in this sequence, but currently lack the fundamental regulatory information needed to harness these fungi for application. Thus, the major goal of this project was to use systems biology to create an integrated model of brown rot wood decay that couples fungal gene regulation with the metabolite feedbacks used to coordinate a two-step oxidative-hydrolytic mechanism. The research at Clark University focused on phylogenomic analyses of data produced by other project partners. Hence, the Clark component of the research was staged to initiate somewhat after that in other partner laboratories. The major Clark-based accomplishment was to advise on selection of fungal species for analyses of brown rot decay chemistry, and to interpret results in a phylogenetic context. The Clark University group also performed complementary analyses of gene families encoding plant cell wall-degrading enzymes in the the basidiomycete genus Lentinula, as well as analyses of substrate-specific gene expression and RNA editing in brown rot fungi.

59 BASIC BIOLOGICAL SCIENCES↗

Flexoelectricity and New Phenomena

It is easy to miss the scientific implications of our recent work on Triboelectricity. Everyone knows that rubbing and contact can produce static electricity; less appreciated is that the thermodynamic driver has been an open question since static electricity was first observed by Thales of Miletus around 585 BC. People think they understand it, for instance one common explanation that can still be found in the current literature is that differences in the work function drives charge transfer, often called the Volta-Helmholtz hypothesis. As summarized in 1967 by Harper, this fails to explain many experimental observations, for instance that charging can occur when two pieces of the same material are rubbed against each other. We are the first to place triboelectricity on a solid foundation rooted in quantum mechanics – the flexoelectric effect. We were able to explain a significant number of previously unexplained phenomena: 1) Bipolar tribocurrents associated with stick-slip, due to the change in sign of the strain gradients. 2) A one-third power scaling of tribocurrents with indentation force. 3) Tribocharging when two identical materials are used, these being due to local variations in the asperities so there are usually local potential differences. 4) Inhomogeneous charging of insulators, related to the statistical nature of asperities. 5) An experimentally observed reversal in the sign of charge transfer for negative and positive curvature, which is related to a change in the sign of the strain gradient. Exploiting our DOE prior funded work on flexoelectricity, we obtained semi-quantitative matching to existing experimental measurements of the surface charge in triboelectric experiments. The work has been well received in the literature. The work has been the focus of a number of popular science press articles, and also formed the basis for a Podcast for children 6-10 “The Rise and Fall of Static Man” posted in December 2019 by NPR as part of their “Wow in the World” series. I was also briefly interviewed by the Chicago PBS station in January 2020. This work are significant for a wide range of energy applications; to quote from an independent source: "Triboelectric power has plenty of potential, says Wenzhuo Wu, an assistant professor of engineering at Purdue. If the basics of static electricity are better understood, we could maximize the efficiency of wind or wave power generators, Wu says. The body's own movement could be used to power internal medical devices. Imagine being able to create a roof shaped to harness the power of a raindrop — the friction of the rain passing over the surface — to generate triboelectricity, powering the building below it." This is the start of new science, some of which we already partially understand such as the role of band bending in charge transfer. We need to understand charge transfer combining elasticity, quantum mechanics, band bending and defect states. These directly involve several of the DOE Grand Challenges: "How do we control material processes at the level of electrons? How do remarkable properties of matter emerge from complex correlations of the atomic or electronic constituents and how can we control these properties? How do we characterize and control matter away—especially very far away— from equilibrium?" I will argue that this work truly falls into the class of disruptive science; it is not just a simple extension, linear science. Not everyone will accept the approach. Since we explain far more about triboelectricity than anyone before, the preponderance of evidence supports the model. The feedback I have received is that many agree with the work, to quote: "The model makes sense, says Michael McAlpine, a professor of engineering at the University of Minnesota. "It's such a simple explanation, I was surprised I didn't put my finger on that," McAlpine says." The proposal received strong reviews. It was also publicized on the Department of Energy Web Site.

16 TIDAL AND WAVE POWER↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 1

Washington River Protection Solutions (WRPS) tested four types of chemical cartridges for use in air-purifying respirators (APR) and powered air-purifying respirators (PAPR). These tests were undertaken to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford BY-108 and BY-110 waste storage tanks. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing commonly is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge tests were conducted over two days from February 23-25, 2018, using headspace vapors from Hanford tanks BY-108 and BY-110. Headspace vapors from the BY-108 tank were fed to the PAPR respirator cartridge test stand, while vapors from the BY-110 headspace were fed to the APR respirator cartridge test stand. Both the APR and PAPR test stands were developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Two different cartridges were assessed on each tank. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed for vapors from BY-110 using the APR cartridge test stand. Multipurpose PAPR cartridges—MSA OptiFilter TL (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (3M Company, Maplewood, Minnesota)—also were assessed for vapors from BY-108 over the same two days using the PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and the samples then were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks BY-108 and BY-110 Volume 2: Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used by workers at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of APR and PAPR cartridge testing on BY-110 and BY-108 headspace vapors, respectively. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the BY-110 headspace vapors, and two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed for the BY-108 headspace vapors. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the cartridge testing of vapors from the BY-110 and BY-108 headspaces. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AX Tank Farm Exhauster Slipstream Volume 1

Washington River Protection Solutions (WRPS) conducted tests of four types of chemical cartridges for air-purifying respirators (APR) and powered air-purifying respirators (PAPR) to determine the period of time the cartridges would provide adequate performance1 for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the Hanford AX tank farm exhauster slipstream. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing a cartridge service life. Testing is applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Cartridge testing using vapors from a Hanford AX tank farm exhauster slipstream was conducted from August 25–27, 2017. Vapors from the exhauster slipstream were fed to two respirator cartridge test stands developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Four different cartridges were assessed. Multipurpose APR cartridges—SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina)—were assessed on separate days using an APR cartridge test stand. Multipurpose PAPR cartridges—MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR57 (TL2) (3M Company, Maplewood, Minnesota)—also were tested over the same two days using a separate PAPR cartridge test stand. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests of cartridges used in air-purifying respirators (APR) and powered air-purifying respirators (PAPR) commonly used at Hanford Tank Farms. The tests are conducted to determine the period of time the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. Occupational Safety and Health Administration (OSHA) Standard 29 Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life. The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. This report summarizes data analysis of PAPR cartridge testing on headspace vapors from Hanford SX-101 and SX-104 single-shell tanks. Two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota)—were assessed on each tank headspace source on separate days. These data represent the first PAPR cartridge testing under the recent WRPS program, as testing to date had been focused on APR cartridges. Volume 1 of this report documents the testing, data analysis, results, conclusions, and recommendations resulting from the PAPR testing on SX-101 and SX-104 headspace vapors. Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗