Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy imaging technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Understanding Complex Magnetic Spin Textures with Simulation-Assisted Lorentz Transmission Electron Microscopy

There is an increased interest in topologically nontrivial magnetic spin textures such as skyrmions and chiral domain-wall solitons, both from a point of fundamental physics understanding as well as potential technological interest in low-power memory applications. In order to control their behavior, it is necessary to understand their complex spin texture at the nanoscale. Lorentz transmission electron microscopy (LTEM) is a suitable technique for studying these systems due to its high spatial resolution and capability to simultaneously characterize magnetic texture and microstructure. In this work, we present the application of PyLorentz, an open-source software suite that we have developed, for quantitative image analysis of Neel-type skyrmions in thin-film heterostructures. PyLorentz enhances LTEM capabilities by enabling reconstruction of magnetic induction maps from experimental images, as well as simulating LTEM images using micromagnetic simulation data. We demonstrate this for simulated Neel skyrmions as well as experimental data from [Pt/Co/W] multilayer heterostructures. Finally, we also show how simulation-assisted LTEM analysis is crucial for understanding these complex magnetic spin textures, in which the reconstructed magnetic induction map (seen in the LTEM images) differs significantly from the magnetization configuration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructure and Composition of Passivating Interfaces in Silicon Heterojunction Solar Modules Weathered in Different Climates

Sanyo/Panasonic patented silicon heterojunction with intrinsic thin layer (HIT) solar cells in the 1990's, which demonstrated world record photovoltaic (PV) efficiency around 2014 and inspired the newer generations of silicon heterojunction technology (SHJ) as well as the current world record back-contact PV cell designs. The high-quality passivation strategy, utilizing ultra-thin layers of hydrogenated amorphous silicon (a-Si:H), leads to high voltages and long carrier lifetimes, but these qualities may degrade over time as the modules operate outdoors. Here, we investigate local microstructure and composition at the interface layers of cells from HIT modules weathered in a hot, humid climate (Florida, USA) and temperate climate (Colorado, USA) for 10 years. We employ a comprehensive set of high-resolution electron microscopy imaging and spectroscopy to directly resolve structure and composition in these cells down to the nanoscale. We show features such as alignment of the In2O3 transparent conducting oxide and a-Si:H layers on the textured c-Si facets, interfacial oxidation at the a-Si:H/c-Si and In2O3/a-Si:H interfaces, and twinned c-Si resulting from epitaxial growth into the a-Si:H layer. Our results raise potential degradation mechanisms in these outdoor-weathered modules, but the root cause of electrical loss remains uncertain due to the very small changes in aged samples. This study shows that many atomic scale features at the In2O3/a-Si:H/c-Si interfaces are surprisingly robust, and the electrical losses with aging may either be attributed to other pathways or be very sensitive to the subtle chemical and microstructural features observed here.

14 SOLAR ENERGY↗

Laser‐Powder Melt Pool Solidification Dynamics and Microstructural Engineering of Ti‐5553 Microlattices

The fine geometric and topological control afforded by additive manufacturing technologies has enabled the manufacture of architected materials across length scales, and enabling tunable mechanical performance as a function of local and global design. Progress has been made to tune the mechanical response of architected materials through geometry, but understanding how the geometry and processing conditions will inform the microstructure remains a challenge due to the rapid solidification in laser powder bed fusion. This study uses in situ X-ray imaging and electron backscatter diffraction microscopy to demonstrate that the melt pool size, microstructure morphology, and elastic strain distribution is influenced by a combination of lattice geometry and laser processing conditions. These results indicate that within larger melt pools the local thermal gradients are sufficient to enable a columnar-to-equiaxed transition across the melt pool. Furthermore, the solidification mechanisms producing these microstructures are examined across the first 5 ms of melting and solidification, described via in situ high-speed X-ray imaging and mirrored via multiphysics simulation.

additive manufacturing↗

Very-High Dynamic Range, 10,000 Frames/Second Pixel Array Detector for Electron Microscopy

Precision and accuracy of quantitative scanning transmission electron microscopy (STEM) methods such as ptychography, and the mapping of electric, magnetic, and strain fields depend on the dose. Reasonable acquisition time requires high beam current and the ability to quantitatively detect both large and minute changes in signal. A new hybrid pixel array detector (PAD), the second-generation Electron Microscope Pixel Array Detector (EMPAD-G2), addresses this challenge by advancing the technology of a previous generation PAD, the EMPAD. The EMPAD-G2 images continuously at a frame-rates up to 10 kHz with a dynamic range that spans from low-noise detection of single electrons to electron beam currents exceeding 180 pA per pixel, even at electron energies of 300 keV. The EMPAD-G2 enables rapid collection of high-quality STEM data that simultaneously contain full diffraction information from unsaturated bright-field disks to usable Kikuchi bands and higher-order Laue zones. Test results from 80 to 300 keV are presented, as are first experimental results demonstrating ptychographic reconstructions, strain and polarization maps. We introduce a new information metric, the maximum usable imaging speed (MUIS), to identify when a detector becomes electron-starved, saturated or its pixel count is mismatched with the beam current.

36 MATERIALS SCIENCE↗

Ballistic-Electron-Emission Microscopy Techniques for Nanometer-scale Characterization of Interfaces

Semiconductor interface properties are among the most important phenomena in materials science and technology. The study of metal/semiconductor Schottky barrier interfaces has been the primary focus of a large research and development community for decades. Throughout the long history of interface investigation, the study of interface defect electronic properties have been seriously hindered by the fundamental experimental difficulty of probing subsurface structures. A new method, Ballistic-Electron-Emission Microscopy (BEEM), has been developed which not only enables spectroscopic probing of subsurface interface properties, but also, provides nanometer-resolution imaging capabilities. BEEM employs Scanning Tunneling Microscopy (STM) and a unique spatially localized ballistic electron spectroscopy method...

Bell, L. D.↗

Controlled-Release Microcapsules for Smart Coatings for Corrosion Applications

Corrosion is a serious problem that has enormous costs and serious safety implications. Localized corrosion, such as pitting, is very dangerous and can cause catastrophic failures. The NASA Corrosion Technology Laboratory at Kennedy Space Center is developing a smart coating based on pH-sensitive microcapsules for corrosion applications. These versatile microcapsules are designed to be incorporated into a smart coating and deliver their core content when corrosion starts. Corrosion indication was the first function incorporated into the microcapsules. Current efforts are focused on incorporating the corrosion inhibition function through the encapsulation of corrosion inhibitors into water core and oil core microcapsules. Scanning electron microscopy (SEM) images of encapsulated corrosion inhibitors are shown.

Source record↗

Deformable Mirrors Correct Optical Distortions

By combining the high sensitivity of space telescopes with revolutionary imaging technologies consisting primarily of adaptive optics, the Terrestrial Planet Finder is slated to have imaging power 100 times greater than the Hubble Space Telescope. To this end, Boston Micromachines Corporation, of Cambridge, Massachusetts, received Small Business Innovation Research (SBIR) contracts from the Jet Propulsion Laboratory for space-based adaptive optical technology. The work resulted in a microelectromechanical systems (MEMS) deformable mirror (DM) called the Kilo-DM. The company now offers a full line of MEMS DMs, which are being used in observatories across the world, in laser communication, and microscopy.

Source record↗

Temperature-Dependent Morphological Evolution during Corrosion of the Ni-20Cr Alloy in Molten Salt Revealed by Multiscale Imaging

Understanding the mechanisms leading to the degradation of alloys in molten salts at elevated temperatures is significant for developing several key energy generation and storage technologies, including concentrated solar and next-generation nuclear power plants. Specifically, the fundamental mechanisms of different types of corrosion leading to various morphological evolution characteristics for changing reaction conditions between the molten salt and alloy remain unclear. Here, in this work, the three-dimensional (3D) morphological evolution of Ni–20Cr in KCl–MgCl 2 is studied at 600 °C by combining in situ synchrotron X-ray and electron microscopy techniques. By further comparing different morphology evolution characteristics in the temperature range of 500–800 °C, the relative rates between diffusion and reaction at the salt–metal interface lead to different morphological evolution pathways, including intergranular corrosion and percolation dealloying. In this work, the temperature-dependent mechanisms of the interactions between metals and molten salts are discussed, providing insights for predicting molten salt corrosion in real-world applications.

36 MATERIALS SCIENCE↗

Improving Nb 3 Sn cavity performance using centrifugal barrel polishing

Abstract In this study we will show a new method of polishing for Nb 3 Sn cavities known as centrifugal barrel polishing (CBP). Using this method, Nb 3 Sn coated samples are polished to a surface roughness comparable to a traditional Nb cavity after electropolishing. We also investigate different methods of cleaning the Nb 3 Sn surface after CBP to remove residual abrasive particles. The polished Nb 3 Sn surface is analyzed using confocal laser microscopy, and scanning electron microscopy is used to image the surface and measure the surface roughness after polishing. Transmission electron microscopy is also used for high resolution analysis of the surface after polishing. Finally, we show that CBP can improve the performance of a Nb 3 Sn superconducting radiofrequency cavity.

43 PARTICLE ACCELERATORS↗

Near-Infrared Photon-Counting Camera for High-Sensitivity Observations

The dark current of a transferred-electron photocathode with an InGaAs absorber, responsive over the 0.9-to-1.7- micron range, must be reduced to an ultralow level suitable for low signal spectral astrophysical measurements by lowering the temperature of the sensor incorporating the cathode. However, photocathode quantum efficiency (QE) is known to reduce to zero at such low temperatures. Moreover, it has not been demonstrated that the target dark current can be reached at any temperature using existing photocathodes. Changes in the transferred-electron photocathode epistructure (with an In- GaAs absorber lattice-matched to InP and exhibiting responsivity over the 0.9- to-1.7- m range) and fabrication processes were developed and implemented that resulted in a demonstrated >13x reduction in dark current at -40 C while retaining >95% of the approximately equal to 25% saturated room-temperature QE. Further testing at lower temperature is needed to confirm a >25 C predicted reduction in cooling required to achieve an ultralow dark-current target suitable for faint spectral astronomical observations that are not otherwise possible. This reduction in dark current makes it possible to increase the integration time of the imaging sensor, thus enabling a much higher near-infrared (NIR) sensitivity than is possible with current technology. As a result, extremely faint phenomena and NIR signals emitted from distant celestial objects can be now observed and imaged (such as the dynamics of redshifting galaxies, and spectral measurements on extra-solar planets in search of water and bio-markers) that were not previously possible. In addition, the enhanced NIR sensitivity also directly benefits other NIR imaging applications, including drug and bomb detection, stand-off detection of improvised explosive devices (IED's), Raman spectroscopy and microscopy for life/physical science applications, and semiconductor product defect detection.

Jurkovic, Michael↗

Video frame prediction of microbial growth with a recurrent neural network

The recent explosion of interest and advances in machine learning technologies has opened the door to new analytical capabilities in microbiology. Using experimental data such as images or videos, machine learning, in particular deep learning with neural networks, can be harnessed to provide insights and predictions for microbial populations. This paper presents such an application in which a Recurrent Neural Network (RNN) was used to perform prediction of microbial growth for a population of two Pseudomonas aeruginosa mutants. The RNN was trained on videos that were acquired previously using fluorescence microscopy and microfluidics. Of the 20 frames that make up each video, 10 were used as inputs to the network which outputs a prediction for the next 10 frames of the video. The accuracy of the network was evaluated by comparing the predicted frames to the original frames, as well as population curves and the number and size of individual colonies extracted from these frames. Overall, the growth predictions are found to be accurate in metrics such as image comparison, colony size, and total population. Yet, limitations exist due to the scarcity of available and comparable data in the literature, indicating a need for more studies. Both the successes and challenges of our approach are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

2D IR Microscopy—Technology for Visualizing Chemical Dynamics in Heterogeneous Environments (Final Technical Report)

The primary focus of this project was the design, prototype, and demonstration of a 2D IR microscope. The start date of this project was July 15, 2016 and the project end date was July 14, 2022. In the early years of this project our team designed, prototyped, and completely integrated a homebuilt microscope head with our high-repetition rate 2D IR spectrometer. Once in place our research team focused on characterizing the 2D IR microscope and using it to investigate model systems relevant to energy technologies. As part of this process, we identified two initial chemical systems to use to further develop 2D IR imaging modalities. The first chemical system developed was a room temperature ionic liquid (RTIL) electrolyte system and the second chemical system was a mixture of carbonates and salts developed as a battery electrolyte system. The completion of this project resulted in the full characterization of chemical dynamics in a bulk RTIL system and the demonstration of 2D IR imaging across the RTIL cast as a microdroplet in silicon oil. In addition, we explored the liquid structures and dynamics of organic carbonate mixtures from the vantage point of the vibrational probe, methyl thiocyanate. By the end of the project, we had moved toward in-depth studies of the organic carbonate mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared nanoimaging and nanospectroscopy of electrochemical energy storage materials and interfaces

Electrochemical interfaces are central to the function and performance of energy storage devices. Thus, the development of new methods to characterize these interfaces, in conjunction with electrochemical performance, is essential for bridging the existing knowledge gaps and accelerating the development of energy storage technologies. Of particular need is the ability to characterize surfaces or interfaces in a non-destructive way with adequate resolution to discern individual structural and chemical building blocks. To this end, sub-diffraction-limit low-energy infrared optical probes that exploit near-field interactions within atomic force microscopy platforms, such as pseudoheterodyne nanoimaging, photothermal nanoimaging and nanospectroscopy, and nanoscale Fourier transform infrared spectroscopy, are all powerful emerging techniques. These are capable of non-destructive surface probing and imaging at nanometer resolution. This review outlines recent efforts to characterize ex situ, in situ, and operando electrode materials and electrochemical interfaces in rechargeable batteries with these advanced infrared near-field probes.

25 ENERGY STORAGE↗

Multi-modal chemical characterization of highly viscous submicrometer organic particles

Distinguishing highly viscous organic particles within complex mixtures of atmospheric aerosol and accurate descriptions of their composition, size distributions, and mixing states are challenges at the forefront of aerosol measurement science and technology. Here, we present results obtained from complementary single-particle measurement techniques employed for the in-depth characterization of highly viscous particles. In this study, we demonstrate advantages and synergy of this multi-modal particle characterization approach based on the analysis of individual viscous particles formed in the air-discharged waste produced by a common sewer pipe rehabilitation technology. Using oil immersion flow microscopy, we investigate particle size distributions and morphology of colloidal components present in field-collected aqueous waste condensates. We compare these results with corresponding measurements of viscous particles formed in drying droplets of the aerosolized discharged waste. The colloidal components and viscous particles were found to be approximately 10 µm and 0.5 µm, respectively. The aerosolized viscous particles exhibited a spherical morphology, while the colloidal particles appeared noticeably fractal, resembling fragments of a cured composite material. Chemical imaging of the viscous particles collected on substrates was performed using scanning electron microscopy and soft X-ray spectro-microscopy techniques. Through these methods, comprehensive description of these particles emerged, confirming their high solid-like viscosity, wide-ranging sizes, diverse carbon speciation with high degrees of oxygenation, and high organic volume fractions. The aerosolized viscous particles were further characterized using high-throughput single particle mass spectrometry. This technique provides real-time measurements of composition, size, and morphological metrics for large numbers of individual particles, enabling the identification of their distinct mass spectrometric signatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

"Soiling, Cleaning, and Abrasion: The Results of the Five-Year Photovoltaic Glass Coating Field Study" [Slides]

External contamination ("soiling") of the incident surface is a major limiting factor for solar technologies. A 5-year field glass coupon study was conducted to better understand external contamination and its effects; compare cleaning methods and the use of preventative coatings; and explore the abrasion resulting from cleaning to advise on accelerated abrasion testing. Test sites included the cities of Dubai (UAE), Kuwait City (Kuwait), Mesa (AZ), Mumbai (India), and Sacramento (CA). Through the 5-year cumulative study, dry brush, water spray, and wet sponge and squeegee cleaning methods were compared to no cleaning. Optical microscopy was used to obtain images, including representative color images, grayscale images for object analysis, and oblique images for coating integrity assessment. A thresholding protocol was developed to analyze and distinguish specimens using the ImageJ software. Optical performance was quantified using a spectrophotometer, including comprehensive optical characterization (transmittance, reflectance, and absorptance in addition to forward- and back-scattering). Atomic force microscopy was used to verify the abrasion damage morphology, including the width and depth of surface scratches. Analysis of the results included correlation of optical performance and particle area coverage, rank order (by coating or location), and the acceleration factor for abrasion damage. The efficacy of external cleaning was more readily distinguished from the effectiveness of antisoiling coatings. The acceleration factor for dry brush cleaning of a porous silica coating was found to be on the order of unity.

14 SOLAR ENERGY↗