Asymmetric electrode ionomer for low relative humidity operation of anion exchange membrane fuel cells

The operation of fuel cells under low relative humidity (RH) conditions gives substantial cost and performance benefits. Nonetheless, it is not currently feasible to operate anion exchange membrane fuel cells (AEMFCs) at low RH conditions because current materials for membrane electrode assembly cannot provide sufficient water for the oxygen reduction reaction. In this work, we synthesized polyfluorene ionomers with different ammonium concentrations for anode and cathode to control water management. We designed several asymmetric electrodes that enable high performance under low RH conditions via not only conventional backward water diffusion (anode to cathode) but also forward diffusion (cathode to anode). The AEMFCs using optimized asymmetric electrodes exhibited high H 2 /CO 2 -free air performance (rated power density of circa 540 mW cm -2 at 90 °C under 75% (anode) and 50% RH (cathode) conditions), which is comparable to those of state-of-the-art AEMFCs under nearly water-saturated conditions. The durability of the AEMFCs is excellent, generating 0.6 A cm -2 for >900 h at 80 °C under 50% RH (cathode) conditions. This study demonstrates that high-performance and durable AEMFCs under low RH and high current generating conditions are possible.

25 ENERGY STORAGE↗

An Unsteady Actuator Line Solver to Enable Adjoint Sensitivity Studies for Wake Steering

This study demonstrates the sensitivity of wind turbine wake steering performance to blade design. An actuator line model was implemented within an unsteady adjoint solver that enables efficient execution of gradient-based optimization and sensitivity studies. After first confirming the feasibility of wake steering by controlling actuator line chord profiles and formulating a suitable objective function for wake position, a sensitivity study was conducted to determine the relative importance of chord length as a function of spanwise position on the resulting turbine wake deflection. The results presented here support the idea that blade design choices play a role in wake control. In a larger context, this study demonstrates a computational framework in which turbine and blade designs can be studied at the individual and farm-wide level to enhance wind plant controllability and manage power output.

17 WIND ENERGY↗

A Unified Protocol for CRISPR/Cas9-Mediated Gene Knockout in Tephritid Fruit Flies Led to the Recreation of White Eye and White Puparium Phenotypes in the Melon Fly

Abstract Tephritid fruit flies are among the most invasive and destructive agricultural pests worldwide. Over recent years, many studies have implemented the CRISPR/Cas9 genome-editing technology to dissect gene functions in tephritids and create new strains to facilitate their genetics, management, and control. This growing literature allows us to compare diverse strategies for delivering CRISPR/Cas9 components into tephritid embryos, optimize procedures, and advance the technology to systems outside the most thoroughly studied species within the family. Here, we revisit five years of CRISPR research in Tephritidae and propose a unified protocol for candidate gene knockout in fruit flies using CRISPR/Cas9. We demonstrated the efficiency of our protocol by disrupting the eye pigmentation gene white eye (we) in the melon fly, Zeugodacus cucurbitae (Coquillett) (Diptera: Tephritidae). High rates of somatic and germline mutagenesis were induced by microinjecting pre-assembled Cas9-sgRNA complexes through the chorion of embryos at early embryogenesis, leading to the rapid development of new mutant lines. We achieved comparable results when targeting the we orthologue in the oriental fruit fly, Bactrocera dorsalis (Hendel) (Diptera: Tephritidae), illustrating the reliability of our methods when transferred to other related species. Finally, we functionally validated the recently discovered white pupae (wp) loci in the melon fly, successfully recreating the white puparium phenotype used in suppression programs of this and other major economically important tephritids. This is the first demonstration of CRISPR-based genome-editing in the genus Zeugodacus, and we anticipate that the procedures described here will contribute to advancing genome-editing in other non-model tephritid fruit flies.

Entomology↗

Efficient Network Partitioning: Application for Decentralized State Estimation in Power Distribution Grids

Increase in the proliferation of distributed energy resources require real-time situational awareness for efficient grid operations. State estimation plays an important role for the real-time control and management of the power grid. As the sensing infrastructure grows, aggregating and handling high volumes of data at a centralized location is extremely difficult. To address this challenge, this paper first proposes a novel and efficient hier-archical spectral clustering-based network partitioning algorithm followed by a decentralized compressive sensing (DCS)-based state estimation. The applicability of the proposed network partitioning algorithm is tested on an IEEE 123-bus network, an IEEE 8,500-node system, and a 6,000+ node distribution network. The results shows that the proposed approach efficiently divides the network into multiple sub-networks with the minimum number of edge connections among the neighbors. Then, we perform DCS-based state estimation on the 6,000+ node distribution network after dividing the network into 18 optimal partitions. Simulation results show that the DCS-based state estimation recovers the system states with high accuracy and low complexity.

alternating direction method of multipliers↗

Enhanced Tensor Completion Based Approaches for State Estimation in Distribution Systems

Grid state estimation is essential for effective control and management of distribution systems. While weighted least squares has been the conventional method for state estimation, sparsity-aware methods have become popular due to their superior performance with limited data. Matrix completion and compressed sensing-based state estimation approaches exploit the underlying smoothness in the state variables. However, classic matrix completion methods do not take into account the temporal correlation of system states. Compressed sensing methods, on the other hand, require an appropriate choice of sparsifying basis that may not be easy to identify. This paper proposes a blocktensor completion based framework which uses an alternative approach to estimate voltage phasor, power injections and branch currents. This approach utilizes the temporal correlation of the system states in a tensor trace-norm minimization formulation with power flow equations as constraints. Herein, feature scaling is introduced in the problem formulation to benefit from the improved sensitivity of the tensor trace norm to the matrix columns in the scaled unfoldings of the tensor. Weighted tensor norm is utilized to exploit the structures of the different unfoldings of the state measurement tensor to improve the voltage estimation. The estimation accuracy is further improved by alternatively estimating the tensor columns and increasing the available data at each stage in the tensor completion process. The proposed methods are evaluated on the IEEE-33, 37 test systems and a 100- node test system. The proposed methods are shown to provide significant performance gains relative to the classic matrix and tensor completion based approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Versatile High-Gain Low-Noise Readout ASIC for Silicon Microstrip Tracking Detectors

This work presents Turpial, a custom-designed low- power front-end readout ASIC for microstrip silicon sensors. Implemented in 130 nm CMOS technology, the chip integrates 64 identical readout channels, each including a configurable charge-sensitive amplifier, a bipolar pulse shaper, a 32-sample 50 Msps analog memory, and a 12-bit RC-hybrid SAR ADC operating at 1 Msps. To satisfy the target power budget of 5 mW per channel, the architecture employs a time-decoupled readout scheme in which fast transient signals are first captured in the analog memory and subsequently digitized at a lower rate. Turpial supports a wide dynamic range from 1 kℎ+ to 1 Mℎ+ while maintaining low noise performance, targeting an equivalent noise charge (ENC) below 200 𝑒−including the sensor, and providing a maximum gain of 1500 mV/fC. A digital block manages slow control, data acquisition, and data serialization through dual CML 300 Mb/s serializers. In addition, an on-chip reference circuit, based on a sub-1 V bandgap reference and an integrated LDO regulator, eliminates the need for external reference circuitry. Experimental results demonstrate that both the individual building blocks and the fully integrated ASIC meet the design specifications.

Hernandez, Hugo [Stanford University] (ORCID:00000↗

ML-AMD/exa-pd

Exa-pd is a highly parallelizable workflow for constructing multi-element phase diagrams (PDs). It uses standard sampling techniques—molecular dynamics (MD) and Monte Carlo (MC)—as implemented in the LAMMPS package, to simultaneously sample multiple phases on a fine temperature–composition mesh for free-energy calculations. The workflow uses Parsl as a global controller to manage the MD/MC jobs to achieve massive parallelization with almost ideal scalability. The resulting free energies of both liquid and solid phases (including solid solutions) are then fed to CALPHAD modeling using the PYCALPHAD package for the construction of a multi-element PD.

Zhang, Feng [Ames Laboratory (AMES), Ames, IA (Uni↗

Modelling of Wastewater Heat Recovery Heat Pump Systems

Wastewater heat recovery is currently an underutilized technology that could be part of solving the climate crisis. A large portion of the heat that leaves a building in the form of wastewater is potentially recoverable for pre-heating domestic hot water or other service water systems. While there are several different approaches to wastewater heat recovery, this project focused on creating detailed, integrated building models for wastewater heat recovery heat pump systems. EnergyPlus models were developed featuring inputs and assumptions corresponding to manufacturers’ specifications, performance lab test data and feedback from engineering consultants. EnergyPlus’s supervisory control Energy Management System objects were heavily relied upon to overcome modelling challenges. The developed EnergyPlus model was integrated into U.S. Department of Energy New Construction Reference Building models for various climate zones and building types to assess potential energy use, energy cost and greenhouse gas emission reductions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fused silica optics damage from downstream intensification on laser-induced damage precursors

Management and control of damage initiation and growth on high-value National Ignition Facility (NIF) optics are critical to its operation. Cone-shaped features are currently being used on the input surfaces to arrest growth of exit surface damage by creating “shadows.” Light refracted from the walls of the cones interferes with the incident beam at the exit surface to create an intensified annulus. Significant exit surface damage was observed at the locations of these annuli. Analysis showed that this damage is consistent with a recently reported new mechanism that degrades damage resistance by dispersing damage precursors over the surface upon exposure to UV laser radiation. This has significant implications for the design and operation of high-energy and power laser systems such as the NIF.

47 OTHER INSTRUMENTATION↗

AmeriFlux US-AMS Argonne Testbed for Multiscale Observational Science (ATMOS)

This is the AmeriFlux version of the carbon flux data for the site US-AMS Argonne Testbed for Multiscale Observational Science (ATMOS). Site Description - This tower is located at Argonne National Laboratory approximately 2 km north of the Des Plaines river and 115 m NNW from the ATMOS meteorological tower. It is downwind of a seasonally wet grassland bordered by forest 40 m N of the flux tower. The area was managed by controlled burns until 2019.

McNicol, Gavin [University of Illinois at Chicago]↗

Standardizing UI/UX across accelerator labs

During February 26–28, 2025, the first-ever particle accelerator user interface/user experience (UI/UX) workshop was held at SLAC. Attendees had backgrounds ranging from software development to control systems management and human factors (HF) science. The workshop began with participants discussing the current state of UI/UX procedures and practices at their respective laboratories to share experiences and learn from one another. Additional discussions focused on how to effectively integrate UI/UX best practices into actionable goals for developers, managers, and operators when working on new or existing interfaces. The goal of the working group is to create a website that will guide developers, managers, scientists, and end users at accelerator laboratories in incorporating UI/UX best practices into software development. The working group continues to meet virtually toward this goal, and is planning a second workshop for next year.

Tran, Tiffany [SLAC]↗

Integrating System to Edge-of-Network Architecture and Management for SHINES (SEAMS) Technologies of High Penetration Grids

Consistent with the U.S. DOE’s EERE SHINES FOA objectives, the goal of this project was to enable integration from EMS to variable DER in a way that delivered visibility and opportunities for managing and controlling distributed resources using SEAMS technologies. This project implemented several SHINES technologies, which included: (1) three Stem battery systems; (2) six ConnectDER PV collars; (3) two E-Gear PV/Battery storage interfaces; and (4) eight Kitu smart inverter emulators. A Siemens Energy IP DEMS was deployed in a development environment and integrated with the SHINES technologies via OpenADR and IEEE 2030.5 protocols with documented architecture. In the case of IEEE 2030.5, a suite of technologies including a gateway, an API, software and a server from Kitu Systems (the Citadel, Convoy, Kitu Crosslink API, and Kitu Spark) were used to demonstrate that the utility could achieve visibility of distributed energy resources (DER) and control of single and multiple DER systems with a single command. The project also included a LCOE analysis of SHINES technologies compared to traditional system and circuit mitigation measures.

14 SOLAR ENERGY↗

Request for Information on Establishing a New Manufacturing Institute (DE-FOA-0002564)

Deep decarbonization of major industries such as metals manufacturing requires extensive process integration and controls to manage feedstocks, side reactions, heat, water, and waste streams. The scale of the energy and capital investment requires that process integration be validated to a high level of confidence with no bias. Industries such as steel production have very thin profit margins. Therefore, lack of confidence in process integration, product quality, and economics is a major deterrence to changes in manufacturing capital investment. Public sector investment in reconfigurable pilot testbeds and a first-of-a-kind plant would be necessary to de-risk technical and financial barriers prior to industry-wide buildout. DOE should consider a National Lab-led hub for the testbeds. Lab testbeds could be utilized in campaigns and allow multiple industrial partners to evaluate and validate technologies prior to making major capital investments.

08 HYDROGEN↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Using the power of secure Generative AI to eliminate data silos

Over time, multiple information repositories, access controls, and management practices created disparate information silos. Gaining accurate insights from lab information had become overly burdensome especially for new employees and collaborators

Purcell, Kevin↗

Peer-to-peer communication control for resilient operations of networked cyberphysical systems

This report includes two main accomplishments of the peer-to-peer communication control for resilient operation of networked microgrids project in FY24, which include a scheme for cyberattack-aware coordination of networked microgrids for supporting voltages of bulk power systems and a scheme for price signal-based operations of EV-rich networked microgrids with mixed ownership. First, the cyberattack-aware scheme enables networked microgrids to distributedly determine the amount of reactive power injection to support the voltage of bulk power system (BPS) in a fair manner. In this scheme, a risk-informed algorithm is presented to generate the peer-to- peer (P2P) communication graph with minimal risk of attack on communication links. To deal with cyberattacks on MG controllers, the resilient consensus algorithm (CA) is utilized for MG controllers to robustly estimate the total reactive power headroom, from which the MGs can accurately provide the needed amount of reactive power injection for supporting the voltage of BPS. The CA implementation and performance within the P2P communication framework are demonstrated on the IEEE 39-bus system with 6 microgrids contained in the distribution feeder under different cyberattack scenarios. Second, the price-based scheme enables the usage of the real-time price signal for the operations of electric vehicle (EV)-rich networked-microgrids with mixed ownership, in which not all the microgrids can communicate with the distribution system operator (DSO). In this scheme, a max consensus is introduced to enable the real-time price signal to be propagated from the DSO to all the microgrids, from which each microgrid controller will manage the DERs to balance the load demand and the power injection from the EV charging stations within its microgrid. Numerical results over one day with 288 slots of 5-minute intervals on the modified 123-node test feeder including 3 microgrids with high penetration of EV are presented to evaluate how the price signal affects the operations of networked microgrids under different charging strategies of the EV charging stations. The result indicates that our proposed EVCS (dis)charging strategy, which leverages the flexibility of EVs to support the grid through discharging during peak demand, proves to be a cost-effective solution that reduces operational costs while improving the social welfare of EV charging.