Basic performance of a multilayer insulation system containing 20 to 160 layers

An experimental investigation was conducted to determine the thermal effectiveness of an aluminized Mylar-silk net insulation system containing up to 160 layers. The experimentally measured heat flux was compared with results predicted by using (1) a previously developed semi-empirical equation and (2) an effective-thermal-conductivity value. All tests were conducted at a nominal hot-boundary temperature of 294 K (530 R) with liquid hydrogen as the heat sink. The experimental results show that the insulation performed as expected and that both the semi-empirical equation and effective thermal conductivity of a small number of layers were adequate in predicting the thermal performance of a large number of layers of insulation.

Stochl, R. J.↗

Thermal performance of multilayer insulations

Experimental and analytical studies were conducted in order to extend previous knowledge of the thermal performance and gas evacuation characteristics of three selected multilayer insulation (MLI) composites. Flat plate calorimeter heat flux measurements were obtained for 20- and 80- shield specimens using three representative layer densities over boundary temperatures ranging from 39 K (70 R) to 389 K (700 R). Laboratory gas evacuation tests were performed on representative specimens of each MLI composite after initially purging them with helium, nitrogen, or argon gases. In these tests, the specimens were maintained at temperatures between 128 K (230 R) and 300 K (540 R). Based on the results of the laboratory-scale tests, a composite MLI system consisting of 112 unperforated, double-aluminized Mylar reflective shields and 113 water preconditioned silk net spacer pairs was fabricated and installed on a 1.22-m-(4-ft-) diameter calorimeter tank.

Keller, C. W.↗

Apparatus for controlling the temperature of balloon-borne equipment

A novel apparatus for controlling the temperature of balloon-borne equipment is disclosed, the apparatus serving to utilize the radiant energy emitted by the earth and its atmosphere so as to control the temperature of equipment. The apparatus comprises a housing to be carried aloft by a balloon and defining an enclosure for an instrumentation package. The enclosure includes an upper shield portion as well as a bottom window portion at the base, the bottom window facing the earth below during flight. The upper shield portion is constructed of a material such as aluminized Mylar, which serves to reflect direct sunlight.

Schach, M.↗

Steady state thermal radiometers

A radiometer is described operating in a vacuum under steady state conditions. The front element is an aluminum sheet painted on the outer side with black or other absorptive material of selected characteristics. A thermocouple is bonded to the inner side of the aluminum sheet. That is backed by highly insulative layers of glass fiber and crinkled, aluminized Mylar polyester. Those layers are backed with a sturdy, polyester sheet, and the entire lamination is laced together by nylon cords. The device is highly reliable in that it does not drift out of calibration, and is significantly inexpensive.

Loose, J. D.↗

Analytic and experimental evaluation of shadow shields and their support members for thermal control of space vehicles

The thermal performance of shadow shields, and their support struts, for the thermal protection of cryogenic propellants in a simulated deep-space environment was investigated analytically and experimentally. Very low overall heat-transfer rates were obtained when highly reflective aluminized Mylar shadow shields were used. The thermal interactions between the shields and support struts were investigated with fair to good agreement between the analysis and experimental data. The exterior surface of both fiberglass and titanium struts was coated to reduce the heat input into the test tank. The vacuum level inside the test facility strongly influenced the heat-transfer rates.

Boyle, R. J.↗

The efficient identification of relativistic particles by transition radiation

A system of transition radiation detectors has been constructed and exposed to beams of electrons and pions in the energy range of 3 to 15 GeV at SLAC. Transition radiation was generated in a variety of stacks of mylar foils (radiators), and its intensity was detected with 7 multiwire proportional chambers. The raw data demonstrate a good separation between electron and pion induced signals. A more detailed analysis shows that a very efficient identification of individual particles is possible. Typically, a detection efficiency for electrons above 90%, combined with a pion-electron discrimination ratio of .001, has been achieved. Some conclusions with respect to the design of a practical detector for relativistic particles are drawn.

Cherry, M. L.↗

Testing of flat conductor cable to Underwriters Laboratory standards UL719 and UL83

The flat conductor cable (FCC) which was tested consisted of three AWG No. 12 flat copper conductors laminated between two films of polyethylene terephthalate (Mylar) insulation with a self-extinguishing polyester adhesive. Results of the tests conducted on this cable, according to specifications, warrants the use of this FCC for electrical interconnections in a surface nonmetallic protective covering.

Loggins, R. W.↗

Status of the NASA-Lewis flat-plate collector tests with a solar simulator

Simulator test results of 15 collector types are presented. Collectors are given performance ratings according to their use for pool heating, hot water, absorption A/C or heating, and solar Rankine machines. Collectors found to be good performers in the above categories, except for pool heating, were a black nickel coated, 2 glass collector, and a black paint 2 glass collector containing a mylar honeycomb. For pool heating, a black paint, one glass collector was found to be the best performer. Collector performance parameters of 5 collector types were determined to aid in explaining the factors that govern performance. The two factors that had the greatest effect on collector performance were the collector heat loss and the coating absorptivity.

Simon, F. F.↗

Investigation of land-use spectral signatures

A technique was developed to obtain bidirectional reflectance data from natural surfaces by using a folding mirror to transfer the reflected energy from the test surface to a spectroradiometer. The folding mirror was a first surface reflector made by stretching Mylar vacuum coated with aluminum over a light weight frame. The optically folding mirror was positioned over the test surfaces with a moveable platform for both laboratory and field tests. Field tests were conducted using a tethered balloon system to position the folding mirror. A spectroradiometer was designed and built specifically for this investigation. The spectroradiometer had an angular field of view of twenty-four minutes in one axis and ten minutes in the other axis. The radiometer was capable of detecting energies in small bandwidths throughout the electromagnetic spectrum from 0.3 microns to 3.0 microns. Bidirectional reflectance data and variations in the data with source angles were obtained for Saint Augustine grass, Bermuda grass, and a black alluvium soil from the Mississippi River delta.

Hagewood, J. F.↗

Transition radiations in X-ray region

The theory of production of radiations in the transoptical region by the passage of high energy charged particles through the interface of two media is discussed. Based on the theoretical model, calculations are made for electrons of selected energy range passing through Mylar.

George, M. C.↗

Status of the NASA-Lewis flat-plate collector tests with a solar simulator

Simulator test results of 15 collector types are reported. Collectors are given performance ratings according to their use for pool heating, hot water, absorption A/C or heating and solar Rankine machines. Collectors found to be good performers in the above categories, except for pool heating, were a black nickel coated, 2 glass collector, and a black paint 2 glass collector containing a mylar honeycomb. For pool heating, a black paint, one glass collector was found to be the best performer. Collector performance parameters of 5 collector types were determined to aid in explaining the factors that govern performance. The two factors that had the greatest effect on collector performance were the collector heat loss and the coating absorptivity.

Simon, F. F.↗

Compliant wall-turbulent skin-friction reduction research

Previous compliant-wall experiments successful in reducing skin-friction drag probably have had a (unplanned) membrane resonance at a favorable frequency, amplitude, wave shape, length, and speed. The most probable drag reduction mechanism involves a direct coupling between the fluid and the moving wall when the wall natural resonance frequencies are near the fundamental turbulent burst frequency. Local skin-friction reductions of 61% were measured with mylar/PVC plastisol compliant surfaces. These reductions were observed only at certain flow conditions, indicating that changing tunnel total temperature may have altered the substrate dynamic modulus, damping, and coupled mylar tension. Apparently, the coupled membrane/substrate must be excited in compatible narrow-band natural frequency modes. An accelerated effort is required to develop practical durable compliant surfaces optimized for maximum drag reduction. Application of compliant walls to other transportation modes appears feasible with liquid flows offering the greatest skin-friction drag reduction potential.

Fischer, M. C.↗

High-resolution system for tropospheric wind and temperature profile measurements

This paper briefly describes the Jimsphere/Jimsonde system and presents some possible applications of the system. As space vehicles became larger and more sophisticated, an improved method for obtaining wind-profile data had to be found. To satisfy this need, the FPS-16 radar/Jimsphere system was developed. The Jimsphere is an aluminized mylar spherical balloon 2 m in diameter. The balloon is under superpressure and is tracked with a high-precision radar system. The development of this detailed wind-profile system was started in 1963, and the present design was established in 1964. To improve the system, a program was initiated in 1965 to obtain high-resolution temperature data simultaneously with the wind-profile data.

Camp, D. W.↗

Uniform solar cells

Solar cells used in radiation sensors can be efficiently matched by individual trimming. Strip of aluminized Mylar is used to adjust cell output to within required tolerances. Method is faster than individual selection of matched cells.

Source record↗

Testing flat-conductor cable

Report describes characteristics of type of FCC which consists of three AWG No. 12 flat copper conductors laminated between two films of polyethylene terephthalate (Mylar) insulation with self-extinguishing polyester adhesive.

Loggins, R. W.↗

Improved insulation material

Multilayer material consisting of embossed, silver-coated Mylar, nylon net, and silk net is useful for thermal-protection systems and cryogenic containers. Embossing serves two purposes: helps separate radiation barriers and controls radiant energy diffusion. Insulation requires no maintenance after installation.

Source record↗

External heater for cryogenic vessels

When used in conjunction with nitrogen purge system, external heating film increases gas temperature, thereby preventing chilling of equipment. Proposed system includes vacuum-deposited layer of gold sandwiched between two layers of Mylar, which act as carrier for film and prevent damage.

Wennagel, G. J.↗

Dewar technology study

The development of a Dewar system for handling liquid helium under weightless conditions is described. Porous plug designs for the prevention of superfluid creep out of the dewar through the vent line were evaluated. For the purpose of designing a neck to provide a transition from the cold cavity to the outside, the loads carried by the neck and equipment supports were studied. Temperature, pressure, and mass flow instrumentation for monitoring Dewar performance were also evaluated. In addition, multilayer blankets consisting of aluminized Mylar separated by Dacron net sheets were designed to insulate the pressure vessel. The dewar system is suggested for use with the star tracking telescope aboard the relativity satellite.