Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MU2E”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Quality Assurance on a Custom SiPMs Array for the Mu2e Experiment

The Mu2e experiment at Fermilab will search for the coherent $\mu \to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, status and perspective of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $\mu \to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $\mu$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. Here, in this paper we present the calorimeter design and the latest R&D results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LLRF System for the Fermilab Muon g-2 and Mu2e Projects

The Mu2e experiment measures the conversion rate of muons into electrons and the Muon g-2 experiment measures the muon magnetic moment. Both experiments require 53 MHz batches of 8 GeV protons to be re-bunched into 150 ns, 2.5 MHz pulses for extraction to the g-2 target for Muon g-2 and to a delivery ring with a single RF cavity running at 2.36 MHz for Mu2e. The LLRF system for both experiments is implemented in a SOC FPGA board integrated into the existing 53 MHz LLRF system in a VXI crate. The tight timing requirements, the large frequency difference and the non-harmonic relationship between the two RF systems provide unique challenges to the LLRF system design to achieve the required phase alignment specifications for beam formation, transfers and beam extinction between pulses. The new LLRF system design for both projects is described and the results of the initial beam commissioning tests for the Muon g-2 experiment are presented.

43 PARTICLE ACCELERATORS↗

Calibration Trigger and Beam Monitoring for the Mu2e Experiment by Means of Decay-in-Orbit $\mu$

Over the last few decades, more evidence has come out to suggest that lepton flavor may not be conserved, making the study of charged lepton flavor violation all the more important. A promising way to observe this phenomenon is through muon conversion to electron (in the case without neutrinos produced) on Al, as will occur in the Mu2e experiment, which will run over the course of three years, beginning in 2023. A major part of the apparatus is the aluminum muon stopping target, which a beam of muons hits before releasing the products of muon interactions into the tracker and calorimeter. A muon stopped in the stopping target can undergo three different processes: nuclear capture, decay in orbit and electron conversion, the last of which makes up the E=105 MeV signal we are aiming to observe. Many muons, however, are scattered into a proton absorber around this target. Muons scattered in this way eventually get stopped in the absorber and then undergo decay-in-orbit , with ele ctron products that peak in their momentum distribution at about 50 MeV/c, giving a reference peak that can be used to calibrate the tracker momentum response. A track trigger was then developed to select events with these tracks. The muon beam used in the Mu2e experiment, however, due to the magnetic field on the beam line, is tilted slightly downward, such that more particles interact with the lower part of the tracker. For calibration purposes it is preferable to have a homogeneous distribution of electrons in the tracker volume, requiring a pre-scale factor that is dependent upon the azimuthal angle of the trajectory of closest approach of the helix to the solenoidal axis (“phi”). The factor in question was then found by running Monte Carlo simulations of the electrons produced in the muon decay in the proton absorber, overlaid with background particles. In addition to being used as means to calibrate momentum distribution, these electron tracks can be used to monitor the muon beam profile for changes over time.Here, these processes are explained in greater detail, and the result of the expected trigger performance is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Trigger Rate of High Energy Electrons in the Mu2e Experiment

aThe Mu2e Collaboration will look for Charged Lepton Flavor Violation (CLFV) decay processes, with a sensitivity goal of 10E-17. The experiment is searching for a 105 MeV electron, which will be detected using a straw tracker solenoid and a crystal calorimeter. With a goal processing time of less than 5 milliseconds per event and a target rejection greater than 100, it is critical that the trigger software is optimized for speed and performance. The trigger is responsible for parsing data from the detector and determining which events to keep. By examining the properties CLFV event helices are expected to have, a specific set of parameters, or cuts, were used to create Mu2e triggering algorithms. The following research is an investigation into the efficiency of the trigger and a calculation of the rate at which these events will be triggered. With the combined contribution of two helix reconstruction algorithms, the trigger will be expected to accept approximately on e CLFV candidate electron event per second, with a triggering rate of .86 Hz.

43 PARTICLE ACCELERATORS↗

Fabrication and installation of the Mu2e cryogenic distribution system

The muon-to-electron conversion (Mu2e) experiment at Fermilab will be used to search for the charged lepton flavor-violating conversion of muons to electrons in the field of an atomic nucleus. The Mu2e experiment is currently in the construction stage. The scope of this paper is the cryogenic distribution system and superconducting power leads for four superconducting solenoid magnets: Production Solenoid (PS), an Upstream and Downstream Transport Solenoids (TSu and TSd) and Detector Solenoid (DS). The design of the cryogenic distribution system and the fabrication of several sub-systems was reported previously. This paper reports on additional fabrication and installation progress that has been performed over the past two years. Lessons learned during fabrication and testing of the cryogenic distribution system components are described. In particular, the challenges and solutions implemented for aluminum welding are reported. A description of the process used to qualify the welding procedure and welders for welding the aluminium stabilized NbTi superconducting power leads is provided. Additionally, the progress made with regards to installing the power leads into the cryogenic Feedboxes is covered.

White, Michael J.↗

Design and Status of the Mu2e Crystal Calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour-violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The calorimeter plays an important role in providing a fast trigger filter, excellent particle identification and a seeding for track reconstruction. Its requirements are to provide an energy (timing) resolution better than 10% (0.5 ns) and a position resolution below 1 cm, for 100 MeV electrons. The calorimeter consists of two disks, each one made of 674 un-doped CsI crystals readout by two large area arrays of 2 × 3 UV-extended SiPMs of 6 × 6 mm 2 dimensions. A large scale prototype (Module-0) has been constructed and tested with an electron beam in the energy range between 60 and 120 MeV at the BTF of Frascati National Laboratories. Results demonstrated that this calorimeter satisfies the Mu2e requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e experiment: Simulation of the Production Target

The Mu2e experiment will search for coherent, neutrinoless conversion of muons to elections in an aluminum stopping target. A simulation program is used to experiment and design the production target of the Mu2e experiment. The module uses programing languages and libraries to work. The program called the Offline uses C++ as the programing language in the module. To construct the simulation, the Geant4 library constructs shapes and uses them in the simulation program, ROOT. The offline program simplifies the creation of the tube by organizing them into parameter objects and nesting them with other variables required to construct the tube-like center point, material, or if it is allowed to conflict with other solids. The parameter varies for every solid tube. The geometry file uploads the parameters by declaring and organizing the parameters in C++ using the configuration tools. The author describes the development and the future of this project.

Szewczyk, Albert↗

Mu2e Tracker Electronics - Construction of a Straw Tracker

The Mu2e experiment, currently under construction at the Fermi National Accelerator Laboratory (FNAL) in Batavia, Illinois, is a particle physics experiment designed to detect Charged Lepton Flavor Violation (CLFV) via muon-to-electron conversion, a process beyond the Standard Model (BSM). One of the primary Mu2e detectors is the Straw Tracker, whose purpose is to measure the momentum of the electron, identify the signal, and reject background. The straw tubes are being read out by a total of 20,736 preamplifiers (preamps) within 36 planes that make up the Tracker. In this presentation, the installation of electronics into the Tracker, the implementation of anti-oscillation copper clips, and the process of installing fully constructed planes into the frame will be discussed in depth.

Lynch, Alec [UC, Berkeley]↗

Mu2e Tracker Electronics - Construction of a Straw Tracker

The Mu2e experiment, located at the Fermi National Accelerator Laboratory (FNAL), also known as Fermilab, in Batavia, Illinois, is an in-progress particle physics experiment aiming to detect Charged Lepton Flavor Violation (CLFV) via the $\mu^-Al\rightarrow e^-Al$ interaction, a Beyond the Standard Model (BSM) process. One of the sections of the Mu2e experiment is the Tracker, which aims to identify the signal and reject the background while the experiment is running. A total of 20,736 Calibration (CAL) and High-Voltage (HV) preamplifiers (preamps) are being installed within 36 planes that make up the Tracker. During this process, MHz oscillations were discovered on the CAL preamps, obscuring desired signal detection in the \~kHz range. To solve this issue, copper clips are installed onto the CALs to remove the MHz oscillations. The installation of electronics into the Tracker will be discussed in depth.

Lynch, Alec Michael [UC, Berkeley; Fermilab]↗

Diagnosing Ghost Bunches with the Upstream Extinction Monitor in the Mu2e Experiment

The Mu2e experiment has a stringent requirement for extinction of the pulsed proton beam, referring to the elimination of particles between proton bunches to a relative level of 10$^-10$, which means a single out-of-time particle in the inter-pulse gaps for every 250 complete proton pulses. As the construction of the Mu2e experiment nears completion, it is crucially important to make an early measurement of the beam extinction in its current condition. Hence the upstream extinction monitor was constructed and operated to probe for problems in the proton pulse structure or a higher than expected incidence rate of out-of-time particles. The analysis in this work comes from data taken in March 2026. The long data run showed a significant presence of out-of-time particles from ghost bunches in the Delivery Ring approximately 388 ns after the centers of the main proton pulses. These are hypothesized to be the result of a combination of a RF frequency mismatch, particle space charge, and machine impedance during the rebunching sequence in the Recycler Ring, which can lead to particles leaking into adjacent buckets, but further studies and simulations are needed to confirm this

Hensley, R. [UC, Davis] (ORCID:0000000216064485)↗

Mu2e Production Target Thermal Test Project

The Mu2e experiment requires a production target that is capable of operating under extreme thermal conditions caused by an 8 GeV proton beam. This project’s objective supports the development of the Mu2e Pro- duction Target by testing the Stickman model’s thermal behavior. Angel Flores Luviano has assisted Jonathan Williams in progressing this project by contributing to the development of a Radiative Cooling Test Fixture (RCTF) that will be used to evaluate the thermal behavior of the new production target model. Engineering calculations were performed to an- alyze thermal performance and pressure drop within the cold well and wa- ter cooling circuit. These calculations also determined the optimal sizing for key components of the water system. An engineering note was made to document these calculations. CAD models of the water circuit piping, thermocouple mounting bars, and radiator chimney were developed, and prototype test rig components were fabricated using 3D printing. Future work will focus on continued RCTF development which includes control system integration, heater hardware design, and interfaces that can be scaled up to increase thermal capacity.

Flores Luviano, Angel Augusto [Unlisted, US]↗

Analysis of Slow Spill Data for the Mu2e Experiment

The execution of the Mu2e experiment requires a stable, low-intensity proton beam from the Delivery Ring to produce clean data and protect equipment. This is done by performing a “slow extraction,” which is the gradual contraction of the stable region within the accelerator’s beam pipe. The Delivery Ring is currently unable to perform slow extraction with the stability required by Mu2e. To resolve this, the FAN-C team is training machine learning models with the purpose of replacing the Delivery Ring’s current PID controllers with AI-powered controllers. Training these models requires clean, processed data from slow spills. Over the course of this project, data from previous slow spills were processed and analyzed, and the clean data, graphs, and insights gained from the process were provided to the FAN-C team to assist them in their efforts.

Osborn, Thomas [Purdue U., West Lafayette]↗

Mu2e straw tube tracker gas flow quality control

Here, we present a tracker gas flow quality control method developed for the Mu2e straw tube tracker. Using time-dependent current measurements, we quantify the onset time of ionization gain induced by an 55 F source during gas exchange, which is correlated to the gas conductance in the straw. This allows for the identification of channels with inadequate flow. This approach is broadly applicable to other gaseous detectors that require high-channel-count screening.

Flow↗

An automated QC station for the calibration of the Mu2e calorimeter readout units

The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. Here, in this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature-dependent calibration procedures for the silicon photomultiplier readout of the cosmic ray veto detector for the Mu2e experiment

The cosmic ray veto detector for the Mu2e experiment consists of scintillation bars embedded with wavelength-shifting fibers and read out by silicon photomultipliers (SiPMs). Here, in this manuscript, the calibration procedures of the SiPMs are described including corrections for the temperature dependence of their light yield. These corrections are needed as the SiPMs are not kept at a constant temperature due to the complexity and cost of implementing a cooling system on such a large detector. Rather, it was decided to monitor the temperature to allow the appropriate corrections to be made. The SiPM temperature dependence has been measured in a dedicated experiment and the calibration procedures were validated with data from production detectors awaiting installation at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance studies of the Mu2e cosmic ray veto detector

The cosmic ray veto (CRV) detector of the Mu2e experiment consists of four layers of plastic scintillation counters that surround the detector solenoid. These counters are embedded with wavelength-shifting fibers and are read out by silicon photomultipliers (SiPMs). The performance of a subset of the CRV counters was studied in a cosmic-ray test stand. Here, using data taken over a two-year period, we report the single-layer muon detection efficiency and the rate at which the light yield degrades due to the aging of the plastic scintillation counters.

Aging↗

Software Architecture and Hardware Organization in Mu2e Solenoid Field Mapping System

Herein, the Mu2e field mapping system is designed to produce high accuracy field maps of the detector solenoid used in the experiment. The data acquisition system is mobile and uses a self-propelled mapper with rotating arms equipped with 3D Hall probes. The measurements require not only accurate magnetic field readouts, but also accurate locations of all Hall probes while measuring data. The latter is accomplished by using the laser tracker to measure positions of several retroreflectors on the field mapper during data acquisition. The measurement process requires scanning the whole space inside the large solenoid and takes many hours to complete, which necessitates its full automation. The automation software includes control of the mapper, readout of Hall and NMR probes and control of a laser tracker, including prediction of retroreflector positions and execution of quality control checks. The software architecture and data acquisition hardware of the field mapping system are described, with special attention given to control of the laser tracker and its integration with the rest of the system.

3d hall probes↗