Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MOSFET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Double-Side Cooled 1.2kV, 300A SiC MOSFET Phase-leg Modules for 200 kW, > 100 kW/L Traction Inverters

The packaging of a double-side cooled 1.2 kV, 149 A SiC phase-leg modules has been reported in recent years for making 100 kW, 100 kW/L traction inverters. Each phase-leg module consists of two SiC MOSFETs, one per switch position. Six of the phase-leg modules are assembled into a segmented inverter configuration to meet the power and power density requirement. In this work, the layout of the phase-leg module was redesigned to include four of the SiC MOSFETs, two per switch position, with the aim of doubling the power to 200 kW and increasing the power density beyond 100 kW/L, but with only a 10.25% footprint increase. Key features of the packaging technology developed in the previous work were implemented in the current work, which include silver sintering for chip bonding and porous silver inter-posts for bonding device source pads to substrate. Parasitic extraction simulation showed that the four-chip module has a low parasitic inductance of 4.7 nH, like the two-chip module. Static characterization of the four-chip prototypes showed a low average on-resistance of 9 mΩ and a low average leakage current of 5 nA at Vds of 1.2 kV.

Zhang, Zichen↗

Boundary treatments in non-equilibrium Green's function (NEGF) methods for quantum transport in nano-MOSFETs

Non-equilibrium Green's function (NEGF) is a general method for modeling non-equilibrium quantum transport in open mesoscopic systems with many body scattering effects. In this paper, we present a unified treatment of quantum device boundaries in the framework of NEGF with both finite difference and finite element discretizations. Boundary treatments for both types of numerical methods, and the resulting self-energy {sigma} for the NEGF formulism, representing the dissipative effects of device contacts on the transport, are derived using auxiliary Green's functions for the exterior of the quantum devices. Numerical results with both discretization schemes for an one-dimensional nano-device and a 29 nm double gated MOSFET are provided to demonstrate the accuracy and flexibility of the proposed boundary treatments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparing smoothing techniques for extracting MOSFET threshold voltage

Measurement noise acts as a barrier to the accurate calculation of threshold voltage by derivative-based extraction methods. We examined several smoothing techniques and their effects on measurement noise in threshold voltage extracted by the linear extrapolation method and the g m /I d method. We applied these techniques on a set of SiC power MOSFET devices before and after they had undergone accelerated thermal testing. The smoothing methods examined are least-squares polynomial fitting, low-pass filtering using Butterworth and Chebyshev fillers, and differential smoothing. These methods are compared by their shift in threshold voltage compared to unsmoothed data and their standard deviation among the measurements of each device. All methods performed poorly at smoothing when extracting via the g m /I d due to the large amounts of high-magnitude subthreshold noise, mostly tending to extract threshold voltages far below the expected value. Differential smoothing provided results closest to the expected value with an absolute shift of 1.2 V on average. The smoothing methods performed better with the LE method. On a failed device, all smoothing methods except polynomial smoothing preserved the large threshold voltage anomaly for four out of five measurements. These results show that choice of smoothing method, if used must be evaluated based on the device and extraction method.

42 ENGINEERING↗

Study of the electrical conductivity at finite temperature in 2D Si- MOSFETs

We investigate the low temperature density dependent conductivity of two dimensional electron systems in zero magnetic field for sample Si-15 MOSFETs. The first purpose of this paper is to establish that the knee of the conductivity σ{sub 0} (σ{sub 0} is the T = 0.3 conductivity obtained by linear extrapolation of the curves of σ (T) for different values of electron density, n{sub s}) as a function of the carrier densities n{sub s} for T = 0.3 K, observed by Lai et al. and Limouny et al. in previous work for two different samples, is independent of temperature. The second aim is the determination of the critical density, n{sub c}, of the metal-insulator transition. Many methods are used in this investigation of n{sub c} which have been already used for other samples. The motivation behind this last study is the observation of many values of n{sub c} that have been obtained from different methods and that are slightly different. We will use in this study three methods with the intention to infer which one is more appropriate to obtain n{sub c}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phonon scattering limited performance of monolayer MoS{sub 2} and WSe{sub 2} n-MOSFET

In this paper we show the effect of electron-phonon scattering on the performance of monolayer (1L) MoS{sub 2} and WSe{sub 2} channel based n-MOSFETs. Electronic properties of the channel materials are evaluated using the local density approximation (LDA) in density functional theory (DFT). For phonon dispersion we employ the small displacement / frozen phonon calculations in DFT. Thereafter using the non-equilibrium Green’s function (NEGF) formalism, we study the effect of electron-phonon scattering and the contribution of various phonon modes on the performance of such devices. It is found that the performance of the WSe{sub 2} device is less impacted by phonon scattering, showing a ballisticity of 83% for 1L-WSe{sub 2} FET for channel length of 10 nm. Though 1L-MoS{sub 2} FET of similar dimension shows a lesser ballisticity of 75%. Also in the presence of scattering there exist a a 21–36% increase in the intrinsic delay time (τ) and a 10–18% reduction in peak transconductance (g{sub m}) for WSe{sub 2} and MoS{sub 2} devices respectively.

36 MATERIALS SCIENCE↗

Gamma response study of radiation sensitive MOSFETs for their use as gamma radiation sensor

Continuous monitoring of gamma dose is important in various fields like radiation therapy, space-related research, nuclear energy programs and high energy physics experiment facilities. The present work is focused on utilization of radiation-sensitive Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs) to monitor gamma radiation doses. Static characterization of these detectors was performed to check their expected current-voltage relationship. Threshold voltage and transconductance per unit gate to source voltage (K factor) were calculated from the experimental data. The detector was exposed to gamma radiation in both, with and without gate bias voltage conditions, and change in threshold voltage was monitored at different gamma doses. The experimental data was fitted to obtain equation for dependence of threshold voltage on gamma dose. More than ten times increase in sensitivity was observed in biased condition (+3 V) compared to the unbiased case.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electric field and temperature effects in irradiated MOSFETs

Electronic devices exposed to ionizing radiation exhibit degradation on their electrical characteristics, which may compromise the functionality of the device. Understanding the physical phenomena responsible for radiation damage, which may be specific to a particular technology, it is of extreme importance to develop methods for testing and recovering the devices. The aim of this work is to check the influence of thermal annealing processes and electric field applied during irradiation of Metal Oxide Semiconductor Field Effect Transistors (MOSFET) in total ionizing dose experiments analyzing the changes in the electrical parameters in these devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of Accelerated Stress-Tests on SiC MOSFET Precursor Parameters

Integrating SiC power MOSFETs is very attractive for advancing power electronic system performance, yet the system reliability with new devices remains in question. This work presents an overview of accelerated lifetime tests and the packaging and semiconductor failure mechanisms they excite. The experiments explained here includes High Temperature Gate Bias (HTGB), Switching Cycling, Power Cycling, and Thermal Cycling. These experiments stress different failure mechanisms, that show degradation in different device parameters including, but not limited to, threshold voltage and on-resistance. These four experiments help illustrate the spectrum between device and package degradation that can be used to design more reliable power electronic circuits.

33 ADVANCED PROPULSION SYSTEMS↗

A Multi-Metrics In Situ Aging Detector for SiC Power MOSFET Modules with Full Driver-Integration Capability

In this paper, the concept and prototype of an aging detector for silicon carbide (SiC) power metal oxide semiconductor field effect transistor (MOSFET) are proposed and described. It leverages the resonant peak values of gate-source voltage at different instants during the switching transients to decode the change of multiple aging indicators, such as the increases of on-state resistance and threshold voltage. Modeling-based analysis is conducted to support the idea. The detector can be fully integrated into gate drivers without any additional connection to the power stage and is functional during normal power stage operation. A prototype unit was built, and preliminary tests were conducted to validate the idea and the practicality of the detector.

aging↗

Area-Efficient, 600V 4H-SiC JBS Diode-Integrated MOSFETs (JBSFETs) for Power Converter Applications

This article reports the demonstration of a low-voltage (<; 600V) monolithically integrated 4H-silicon carbide (SiC) MOSFET and JBS diode (JBSFET). A singlemetal and thermal treatment process were implemented to form ohmic contacts on the n+ and p+ source regions while forming the Schottky contact on the N- SiC epitaxial layer. Different layout methodologies are discussed for fabricating an energy-efficient low-voltage JBSFET by intermittently placing the JBS diode portion in the orthogonal direction to minimize the device area, hence improving the specific ON-resistance and reducing the overall chip size by 46%. A junction termination extension (JTE)-based edge termination structure (the Hybrid-JTE) was implemented to achieve a high breakdown voltage with a very low leakage current. In addition, it was investigated that the forward characteristic of the JBSFET can be further improved by adopting Ti-based metal as the Schottky contact for the JBS diode. Device design, layout approach, fabrication, electrical characterization, and future prospects of the 4H-SiC JBSFETs are discussed in this article.

42 ENGINEERING↗

Probing the Atomic Scale Mechanisms of Time Dependent Dielectric Breakdown in Si/SiO 2 MOSFETs (June 2022)

Here we report on an atomic-scale study of trap generation in the initial/intermediate stages of time-dependent dielectric breakdown (TDDB) in high-field stressed (100) Si/SiO2 MOSFETs using two powerful analytical techniques: electrically detected magnetic resonance (EDMR) and near-zero-field magnetoresistance (NZFMR). We find the dominant EDMR-sensitive traps generated throughout the majority of the TDDB process to be silicon dangling bonds at the (100) Si/SiO2 interface (Pb0 and Pb1 centers) for both the spin-dependent recombination (SDR) and trap-assisted tunneling (SDTAT) processes. We find this generation to be linked to both changes in the calculated interface state densities as well as changes in the NZFMR spectra for recombination events at the interface, indicating a redistribution of mobile magnetic nuclei which we conclude could only be due to the redistribution of hydrogen at the interface. Additionally, we observe the generation of traps known as E’ centers in EDMR measurements at lower experimental temperatures via SDR measurements at the interface. Our work strongly suggests the involvement of a rate-limiting step in the tunneling process between the silicon dangling bonds generated at the interface and the ones generated throughout the oxide.

36 MATERIALS SCIENCE↗

Design Considerations for High-Voltage Insulated Gate Drive Power Supply for 10-kV SiC MOSFET Applied in Medium-Voltage Converter

High-performance gate drive power supply (GDPS) plays a crucial role in ensuring the reliability and safety of the gate driver for power semiconductor devices. This article focuses on the design of a high-voltage-insulated GDPS for the 10-kV silicon carbide MOSFET in medium-voltage (MV) application. Design considerations, including insulation scheme, high-voltage-insulated transformer design, and load voltage regulation scheme, are proposed. In addition, the performance of the secondary-side-regulated (SSR) GDPS and that of the primary-side-regulated (PSR) GDPS are compared for several aspects, including interwinding capacitance, load voltage regulation rate, conversion efficiency, and hardware complexity. Finally, an SSR GDPS and a PSR GDPS, with an insulation voltage of 20 kV, are built in the lab. Furthermore, the test results demonstrate that the PSR GDPS is more preferable because of lower interwinding capacitance, lower load voltage regulation rate, higher conversion efficiency, and simpler control circuit.

42 ENGINEERING↗

Response Variability in Commercial MOSFET SEE Qualification

Single-event effects (SEE) evaluation of five different part types of next generation, commercial trench MOSFETs indicates large part-to-part variation in determining a safe operating area (SOA) for drain-source voltage (V DS ) following a test campaign that exposed >50 samples per part type to heavy ions. These results suggest a determination of a SOA using small sample sizes may fail to capture the full extent of the part-to-part variability. An example method is discussed for establishing a Safe Operating Area using a one-sided statistical tolerance limit based on the number of test samples. Finally, burn-in is shown to be a critical factor in reducing part-to-part variation in part response. Implications for radiation qualification requirements are also explored.

43 PARTICLE ACCELERATORS↗

Formation of PtSi Schottky barrier MOSFETs using plasma etching

PtSi Schottky barrier (SB) MOSFETs were fabricated and their device performance was characterized. PtSi was selected instead of NiSi to form the p-type SB junction since such a configuration would be easy to fabricate through SF{sub 6} based plasma etching. The addition of He-O{sub 2} in SF{sub 6} decreases the etching rate of PtSi while the etching rate of Pt remains unchanged. The retardation in the etching rate of PtSi in He-O{sub 2}/SF{sub 6} is attributed to the formation of a metal oxide on the etched PtSi surface, as evidenced by the x-ray photoelectron spectroscopy results. Optical emission spectroscopy was conducted to establish the endpoint where the wavelength from the feed gas was traced instead of tracing the etching by-products since the by-products have little association with the plasma reaction. The I{sub DS}–V{sub DS} curves at various V{sub G}–V{sub TH} indicate that plasma etching resulted in the successful removal of the Pt on the sidewall region, with negligible damage to the S/D area.

42 ENGINEERING↗

Implantable MOSFET detectors: Evaluation of a new design

The authors have studied the performance of a new version of the implantable MOSFET detector designed for clinical use. Detectors were irradiated under 6- and 18-MV beams in water at body temperature to the calibration dose of 200 cGy/fraction for 20 daily fractions to determine their response and reproducibility. Additional measurements were performed in a solid phantom under 6-MV irradiation at room temperature to daily doses of 100, 150, 200, 250, 400 and 600 cGy/fraction. Finally, the angular dependence with respect to rotation about the detector's longitudinal axis was studied. At body temperature, the detectors were found to have an average response within {+-}3% of the calibration dose with a standard deviation of 2% or less. At room temperature, doses lower than the calibration dose led to a slight overresponse while doses higher than the calibration dose led to a slight underresponse. Angular dependence was not significant, on average within 1.2% of the mean. When used as specified by the manufacturer, these detectors should provide data useful to verify the delivered dose for external beam radiation therapy within a certain tolerance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric characteristics of a single use MOSFET dosimeter for in vivo dosimetry in proton therapy

Purpose: Entrance dose (or skin dose) is an important part of patient quality assurance in external beam radiation therapy. However, entrance dose verification in proton beam is not routinely performed. In this study, the OneDose single use MOSFET detector system for in vivo dosimetry measurement in proton therapy is investigated. Methods: Using a solid water phantom, several fundamental dosimetric characteristics of the OneDose system are studied with a proton beam: The reproducibility (consistency) of the dosimeter, the linearity with dose and dose rate, energy dependence, directional dependence, LET dependence, and fading (delay readout with time) is studied. Results: OneDose detectors show dose and dose rate linearity but exhibit pronounced energy dependence at depth and a large variation in dose response with LET. On the other hand, the detector response remain relatively constant (within 3%) at surface over a wide range of energies. There is also a slight angular dependence (about 2%) up to 60 deg. angle of incidence. However, detector orientation such that incidence along the long axis of the detector should be avoided as the proton beam will have to traverse a large amount of the copper backing. Since most in vivo dosimetry involves entrance dose measurement, the OneDose at surface appears to be well suited for such application. OneDose exhibits small intrabatch variation ({<=}2% at one SD) indicating that it is only necessary to calibration a few detectors from each batch. The interbatch variation is generally within 3%. Conclusions: The small detector size and its relatively flexible design of OneDose allow dose measurement to be performed on a curved surface or in small cavities that is otherwise difficult with the conventional diode detectors. The slight drawback in its angular dependence can be easily handled by angular dependence table. However, since OneDose is a single use detector, the intrabatch consistency must be verified before the remaining detectors from the same batch could be used for in vivo dosimetry. It is advisable that the detectors from the same batch be taken for the same application to reduce the dosimetric uncertainty. For detectors from different batches, interbatch consistency should also be verified to obtain reliable results. OneDose provides an opportunity to measure in vivo dose with proton beam within acceptable clinical criterion of {+-}(5.0%-6.5%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a cable-free system based on p-type MOSFET detectors for 'in vivo' entrance skin dose measurements in interventional radiology

Purpose: During radiological interventional procedures (RIP) the skin of a patient under examination may undergo a prolonged x-ray exposure, receiving a dose as high as 5 Gy in a single session. This paper describes the use of the OneDose{sup TM} cable-free system based on p-type MOSFET detectors to determine the entrance skin dose (ESD) at selected points during RIP. Methods: At first, some dosimetric characteristics of the detector, such as reproducibility, linearity, and fading, have been investigated using a C-arc as a source of radiation. The reference setting (RS) was: 80 kV energy, 40 cm Multiplication-Sign 40 cm field of view (FOV), current-time product of 50 mAs and source to skin distance (SSD) of 50 cm. A calibrated PMX III solid state detector was used as the reference detector and Gafchromic{sup Registered-Sign} films have been used as an independent dosimetric system to test the entire procedure. A calibration factor for the RS and correction factors as functions of tube voltage and FOV size have been determined. Results: Reproducibility ranged from 4% at low doses (around 10 cGy as measured by the reference detector) to about 1% for high doses (around 2 Gy). The system response was found to be linear with respect to both dose measured with the PMX III and tube voltage. The fading test has shown that the maximum deviation from the optimal reading conditions (3 min after a single irradiation) was 9.1% corresponding to four irradiations in one hour read 3 min after the last exposure. The calibration factor in the RS has shown that the system response at the kV energy range is about four times larger than in the MV energy range. A fifth order and fourth order polynomial functions were found to provide correction factors for tube voltage and FOV size, respectively, in measurement settings different than the RS. ESDs measured with the system after applying the proper correction factors agreed within one standard deviation (SD) with the corresponding ESDs measured with the reference detector. The ESDs measured with Gafchromic{sup Registered-Sign} films were in agreement within one SD compared to the ESDs measured using the OneDose{sup TM} system, as well. The global uncertainty associated to the OneDose{sup TM} system established in our experiments, ranged from 7% to 10%, depending on the duration of the RIP due to fading. These values are much lower than the uncertainty commonly accepted for general diagnostic practices (20%) and of about the same size of the uncertainty recommended for practices with high risk of deterministic side effects (7%). Conclusions: The OneDose{sup TM} system has shown a high sensitivity in the kV energy range and has been found capable of measuring the entrance skin dose in RIP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TCAD-Machine Learning Enabled TID Compact Model Development for Commercial SiC MOSFET

We propose a TCAD (Technology Computer Aided Design)-machine learning coupled approach that combines a TCAD tool (Charon), optimization/uncertainty quantification tool (Dakota), surrogate models, and Bayesian learning capabilities. The coupling approach is used for accurate modeling and calibration of total ionizing dose (TID) induced threshold voltage (V th ) shifts in Commercial-Off-The-Shelf (COTS) semiconductor devices and to develop physics-informed TID compact models. This versatile approach is applied to model the TID effect in an exemplar COTS 3.3 kV SiC power MOSFET (Metal-Oxide-Semiconductor Field-Effect Transistor). With the Charon-Dakota coupling, we can determine key device geometry and doping values based on device physics, which are difficult to obtain or not available for COTS devices but important for TCAD simulation; additionally, we can efficiently generate thousands of simulation results in a large parameter space, which makes it possible to develop data-driven surrogate models and perform Bayesian calibration. Utilizing the full tool-coupling approach, we achieve calibrated TCAD simulation models that accurately capture the average TID-induced V th shifts behavior with total doses and V th shifts saturation at high doses as observed in experimental data. More importantly, the calibrated TCAD simulations are obtained with determined TID model parameters (e.g., hole trap density and capture cross section) values that contain well quantified uncertainties. Furthermore, we can isolate and quantify the noises that are not captured by the TCAD models but exist in the measured data due to measurements and devices variabilities. Lastly, the calibrated surrogate models are used to develop physics-informed TID compact models. The method is generalizable to other devices and/or radiation conditions with few modifications and can provide well-determined uncertainties.

COTS↗