Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONOCHROMATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

A WISER way for simulating the performance of gratings

Soft X-ray monochromators for synchrotron radiation sources have been continuously developed over the years, improving energy resolution and stability. Great effort has been made in improving the surface quality of the optics involved, reaching values permitting diffraction-limited images. Still, one problem has not been solved, nor fully understood, yet: groove placing errors. Nowadays, these are one of the major factors responsible for resolving the power reduction of diffraction-gratings-based X-ray monochromators. Despite decades of use of gratings, there is not yet a universally established method for predicting and simulating the effect of groove placing errors on monochromator performance. This is especially important in the new scenario of high-coherent X-ray sources, i.e. diffraction-limited storage rings and free-electron lasers. To address this problem, in this article an approach based on WISER (Wavefront propagatIon Simulation codE libRary) is presented. WISER is a physical optics simulation package, also available in the user-friendly Orange Synchrotron Radiation Suite – OASYS. Even though it was originally conceived to assess the focusing performance of X-ray mirrors in the presence of height defects, it perfectly simulates the performance of a periodic (or quasi-periodic) structure like a diffraction grating. In this article, the way to use WISER and its application to a specific case, e.g. the design of a monochromator for the upgrade of a beamline at the Advanced Light Source, are shown. A simple rule for estimating how well the grooves are placed on a grating, based on calculation of the Strehl ratio, is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarized vacuum ultraviolet and X-radiation

The most intense source of polarized vacuum UV and X radiation is synchrotron radiation, which exhibits a degree of partially polarized light between about 80-100%. However, the radiation transmitted by vacuum UV monochromators can also be highly polarized. The Seya-Namioka type of monochromator can produce partially polarized radiation between 50-80%. For certain experiments it is necessary to know the degree of polarization of the radiation being used. Also, when synchrotron radiation and a monochromator are combined the polarization characteristic of both should be known in order to make full use of these polarization properties. The polarizing effect of monochromators (i.e., diffraction gratings) have been measured at the Seya angle and at grazing angles for various spectral orders. Experimental evidence is presented which shows that the reciprocity law holds for polarization by reflection where the angle of incidence and diffraction are unequal. These results are reviewed along with the techniques for measuring the degree of polarization.

Samson, J. A. R.↗

SAMRAI: A novel variably polarized angle-resolved photoemission beamline in the VUV region at UVSOR-II

A novel variably polarized angle-resolved photoemission spectroscopy beamline in the vacuum-ultraviolet (VUV) region has been installed at the UVSOR-II 750 MeV synchrotron light source. The beamline is equipped with a 3 m long APPLE-II type undulator with horizontally/vertically linear and right/left circular polarizations, a 10 m Wadsworth type monochromator covering a photon energy range of 6-43 eV, and a 200 mm radius hemispherical photoelectron analyzer with an electron lens of a {+-}18 deg. acceptance angle. Due to the low emittance of the UVSOR-II storage ring, the light source is regarded as an entrance slit, and the undulator light is directly led to a grating by two plane mirrors in the monochromator while maintaining a balance between high-energy resolution and high photon flux. The energy resolving power (h{nu}/{Delta}h{nu}) and photon flux of the monochromator are typically 1x10{sup 4} and 10{sup 12} photons/s, respectively, with a 100 {mu}m exit slit. The beamline is used for angle-resolved photoemission spectroscopy with an energy resolution of a few meV covering the UV-to-VUV energy range.

43 PARTICLE ACCELERATORS↗

Nanoradian angular stabilization of x-ray optical components

An x-ray free-electron laser oscillator (XFELO) has been recently proposed [K. Kim et al., Phys. Rev. Lett. 100, 244802 (2008)]. Angular orientation and position in space of Bragg mirrors of the XFELO optical cavity must be continuously adjusted to compensate for the instabilities and maximize the output intensity. An angular stability of about 10 nrad (rms) is required [K. Kim and Y. Shvyd'ko, Phys. Rev. ST Accel. Beams 12, 030703 (2009)]. To approach this goal, a feedback loop based on a null-detection principle was designed and used for stabilization of a high-energy-resolution x-ray monochromator ({Delta}E/E{approx_equal}4x10{sup -8}, E=23.7 keV) and a high-heat-load monochromator. Angular stability of about 13 nrad (rms) has been demonstrated for x-ray optical elements of the monochromators.

43 PARTICLE ACCELERATORS↗

The dedicated QEXAFS facility at the SLS: Performance and Scientific Opportunities

The SuperXAS beamline at the Swiss Light Source (SLS) features a permanently installed monochromator for quick scanning EXAFS (QEXAFS) spectroscopy in series with a conventional double crystal monochromator (DCM). All installed optical components like collimating and focussing mirrors can be used by both devices. The remote exchange of the monochromators is possible in less than five minutes while maintaining the beam geometry on the sample. The QEXAFS system allows fast absorption scans down to the millisecond range for the investigation of time dependent processes. Using a Si(111) channel cut crystal the energy range from 5-16 keV can be covered, with a Si(311) cut the range 9.5-30 keV. Usually a quick scanning interval of 0.1 deg. - 2 deg. in Bragg angle is selected, thus covering XANES, full EXAFS or multiple edge scans of e.g. all L-edges of a heavy element. Up to about 80 spectra per second can be collected, corresponding to a time resolution of 12.5 ms. The high intensity of the beamline even facilitates fluorescence measurements on dilute samples.

43 PARTICLE ACCELERATORS↗

Large-Area Zone Plate Fabrication with Optical Lithography

Zone plates as condenser optics for x-ray microscopes offer simple optical designs for both illumination and spectral resolution when used as a linear monochromator. However, due to the long write times for electron beam lithography, both the availability and the size of zone plates for condensers have been limited. Since the resolution provided by the linear monochromator scales almost linearly with the diameter of the zone plate, the full potential for zone plate monochromators as illumination systems for x-ray microscopes has not been achieved. For example, the 10-mm-diameter zone plate has demonstrated a spectral resolution of E/{Delta}E = 700[1], but with a 26-mm-diameter zone plate, the calculated spectral resolution is higher than E/{Delta}E = 3000. These large-area zone plates are possible to fabricate with the leading edge semiconductor lithography tools such as those available at the College of Nanoscale Science and Engineering at the University at Albany. One of the lithography tools available is the ASML TWINSCAN XT: 1950i with 37-nm resolution [2]. A single 300-mm wafer can contain more than 60 fields, each with a large area condenser, and the throughput of the tool can be more than one wafer every minute.

36 MATERIALS SCIENCE↗

A high resolution and large solid angle x-ray Raman spectroscopy end-station at the Stanford Synchrotron Radiation Lightsource

We present a new x-ray Raman spectroscopy end-station recently developed, installed, and operated at the Stanford Synchrotron Radiation Lightsource. The end-station is located at wiggler beamline 6-2 equipped with two monochromators-Si(111) and Si(311) as well as collimating and focusing optics. It consists of two multi-crystal Johann type spectrometers arranged on intersecting Rowland circles of 1 m diameter. The first one, positioned at the forward scattering angles (low-q), consists of 40 spherically bent and diced Si(110) crystals with 100 mm diameters providing about 1.9% of 4{pi} sr solid angle of detection. When operated in the (440) order in combination with the Si (311) monochromator, an overall energy resolution of 270 meV is obtained at 6462.20 eV. The second spectrometer, consisting of 14 spherically bent Si(110) crystal analyzers (not diced), is positioned at the backward scattering angles (high-q) enabling the study of non-dipole transitions. The solid angle of this spectrometer is about 0.9% of 4{pi} sr, with a combined energy resolution of 600 meV using the Si (311) monochromator. These features exceed the specifications of currently existing relevant instrumentation, opening new opportunities for the routine application of this photon-in/photon-out hard x-ray technique to emerging research in multidisciplinary scientific fields, such as energy-related sciences, material sciences, physical chemistry, etc.

43 PARTICLE ACCELERATORS↗

Characterization and calibration of compact array spectrometers in the ultraviolet spectral region

Array-based spectrometers, with their compact size, low weight, low cost, and fast measurement time, are now frequently used in place of both conventional single-channel scanning monochromators, and broadband meters. Their rapid measurement capability makes them an attractive option for routine solar UV spectral measurements, where shortterm variability in signal is a challenge. However, compactness, portability, low cost and high speed are achieved at the expense of the spectrometer's optical and electronic performance. Thus such spectrometers are more prone to measurement error from environmental changes, and more prone to other intrinsic sources of error such as stray light and detector non-linearity, which significantly affect solar UV measurements, than a scanning monochromator. The effects of stray light and non-linearity can be reduced either by improved optical and detector design or by a detailed spectrometer characterization. We present in this paper our investigation of the performance of three different commercial array spectrometers: two mini-spectrometers, and a more elaborate array spectrometer with an on-board image amplifier device. These were tested for a subset of performance parameters: their wavelength accuracy and stability, electronic linearity, responsivity linearity, stray light sensitivity, and mechanical stability and repeatability. With all three spectrometers we found that these parameters, particularly but not limited to stray light, had a significant impact on the measurement of the incoming optical radiation. This meant that, without characterization, the instruments would be unable to accurately measure the UV component of any source with significant visible radiation. We discuss various simple and low-cost solutions for improving the performance of these instruments, and providing a rigorous calibration using a straightforward set-up including optical filters and the quasi-monochromatic light from a double monochromator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time and spectrum-resolving multiphoton correlator for 300–900 nm

We demonstrate a single-photon sensitive spectrometer in the visible range, which allows us to perform time-resolved and multi-photon spectral correlation measurements at room temperature. It is based on a monochromator composed of two gratings, collimation optics, and an array of single photon avalanche diodes. The time resolution can reach 110 ps and the spectral resolution is 2 nm/pixel, limited by the design of the monochromator. This technique can easily be combined with commercial monochromators and can be useful for joint spectrum measurements of two photons emitted in the process of parametric down conversion, as well as time-resolved spectrum measurements in optical coherence tomography or medical physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase-space matching between bent Laue and flat Bragg crystals

Through phase-space analysis of Dumond diagrams for a flat Bragg crystal, a single bent Laue crystal and a monochromator consisting of double-bent Laue crystals, this work shows that it is possible to match the flat Bragg crystal to both the single-crystal and double-crystal Laue monochromators. The matched system has the advantage that the phase space of the bent crystal's output beam is much larger than that of the flat crystal, making the combined system stable. Here it is suggested that such a matched system can be used at synchrotron facilities to realize X-ray dark-field imaging, analyzer-based imaging and diffraction-enhanced imaging at beamlines using double-Laue monochromators.

36 MATERIALS SCIENCE↗

Two-stage reflective self-seeding scheme for high-repetition-rate X-ray free-electron lasers

X-ray free-electron lasers (XFELs) open a new era of X-ray based research by generating extremely intense X-ray flashes. To further improve the spectrum brightness, a self-seeding FEL scheme has been developed and demonstrated experimentally. As the next step, new-generation FELs with high repetition rates are being designed, built and commissioned around the world. A high repetition rate would significantly speed up the scientific research; however, alongside this improvement comes new challenges surrounding thermal management of the self-seeding monochromator. Here, a new configuration for self-seeding FELs is proposed, operated under a high repetition rate which can strongly suppress the thermal effects on the monochromator and provides a narrow-bandwidth FEL pulse. Three-dimension time-dependent simulations have been performed to demonstrate this idea. Finally, with this proposed configuration, high-repetition-rate XFEL facilities are able to generate narrow-bandwidth X-ray pulses without obvious thermal concern on the monochromators.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dynamic Monitoring of Grating Angle at the National Synchrotron Light Source

We present a dynamic monitoring method and monitoring system of grating angle, referred to as the Precise Angle Monitor (PAM), at U4B, a soft x-ray spherical grating monochromator (SGM) beam line at the National Synchrotron Light Source (NSLS). In an SGM, a photon energy scan is accomplished by rotating the grating angle precisely. After several decades of service, the monochromator at U4B developed instabilities that severely impacted the experimental program. Over several hours, either the spectral shape experienced distortions or the spectral peak shifted. In order to directly monitor the grating motion during scans, the optical head of a portable long trace profiler (PTLTP) was installed on U4B as the PAM. We find that the grating rotational motion is not ideal: (1) the scan steps are not smooth and there are high-frequency step angle errors; (2) there is also a low-frequency angle error; and (3) an unstable thermal expansion produces extra rotational error. Measurements of dynamic monitoring are presented, including grating rotation repeatability and thermal instability. The results illustrate the utility of dynamic monitoring of monochromator motion during actual operation.

43 PARTICLE ACCELERATORS↗

X-ray Optics for BES Light Source Facilities

Each new generation of synchrotron radiation sources has delivered an increase in average brightness 2 to 3 orders of magnitude over the previous generation. The next evolution toward diffraction-limited storage rings will deliver another 3 orders of magnitude increase. For ultrafast experiments, free electron lasers (FELs) deliver 10 orders of magnitude higher peak brightness than storage rings. Our ability to utilize these ultrabright sources, however, is limited by our ability to focus, monochromate, and manipulate these beams with X-ray optics. X-ray optics technology unfortunately lags behind source technology and limits our ability to maximally utilize even today’s X-ray sources. With ever more powerful X-ray sources on the horizon, a new generation of X-ray optics must be developed that will allow us to fully utilize these beams of unprecedented brightness. The increasing brightness of X-ray sources will enable a new generation of measurements that could have revolutionary impact across a broad area of science, if optical systems necessary for transporting and analyzing X-rays can be perfected. The high coherent flux will facilitate new science utilizing techniques in imaging, dynamics, and ultrahigh-resolution spectroscopy. For example, zone-plate-based hard X-ray microscopes are presently used to look deeply into materials, but today’s resolution and contrast are restricted by limitations of the current lithography used to manufacture nanodiffractive optics. The large penetration length, combined in principle with very high spatial resolution, is an ideal probe of hierarchically ordered mesoscale materials, if zone-plate focusing systems can be improved. Resonant inelastic X-ray scattering (RIXS) probes a wide range of excitations in materials, from charge-transfer processes to the very soft excitations that cause the collective phenomena in correlated electronic systems. However, although RIXS can probe high-energy excitations, the most exciting and potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of nanolithographic techniques for improved spatial resolution and efficiency of zone plates. Development of large, perfect single crystals of materials other than silicon for use as beam splitters, seeding monochromators, and high-resolution analyzers. Development of improved thin-film deposition methods for fabrication of multilayer Laue lenses and high-spectral-resolution multilayer gratings. Development of supports, actuator technologies, algorithms, and controls to provide fully integrated and robust adaptive X-ray optic systems. Development of fabrication processes for refractive lenses in materials other than silicon. The workshop participants also addressed two important nontechnical areas: our relationship with industry and organization of optics within the light source facilities. Optimization of activities within these two areas could have an important effect on the effectiveness and efficiency of our overall endeavor. These are crosscutting managerial issues that we identified as areas that needed further in-depth study, but they need to be coordinated above the individual facilities. Finally, an issue that cuts across many of the optics improvements listed above is routine access to beamlines that ideally are fully dedicated to optics research and/or development. The success of the BES X-ray user facilities in serving a rapidly increasing user community has led to a squeezing of beam time for vital instrumentation activities. Dedicated development beamlines could be shared with other R&D activities, such as detector programs and novel instrument development. In summary, to meet the challenges of providing the highest-quality X-ray beams for users and to fully utilize the high-brightness sources of today and those that are on the horizon, it will be critical to make strategic investments in X-ray optics R&D. This report can provide guidance and direction for effective use of investments in the field of X-ray optics and potential approaches to develop a better-coordinated program of X-ray optics development within the suite of BES synchrotron radiation facilities. Due to the importance and complexity of the field, the need for tight coordination between BES light source facilities and with industry, as well as the rapid evolution of light source capabilities, the workshop participants recommend holding similar workshops at least biannually.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scientific Upgrades at the High Flux Isotope Reactor at Oak Ridge National Laboratory

The United States Department of Energy is sponsoring a number of projects that will provide scientific upgrades to the neutron science facilities associated with the high Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory. Funding for the first upgrade project was initiated in 1996 and all presently identified upgrade projects are expected to be completed by the end of 2003. The upgrade projects include: (1) larger beam tubes, (2) a new monochromator drum for the HB-1 beam line, (3) a new HB-2 beam line system that includes one thermal guide and a new monochromator drum, (4) new instruments for the HB-2 beamline, (5) a new monochromator drum for the HB-3 beam line, (6) a supercritical hydrogen cold source system to be retrofitted into the HB-4 beam tube, (7) a 3.5 kW refrigeration system at 20 K to support the cold source and a new building to house it, (8) a new HB-4 beam line system composed of four cold neutron guides with various mirror coatings and associated shielding, (9) a number of new instruments for the cold beams including two new SANS instruments, and (10) construction of support buildings. This paper provides a short summary of these projects including their present status and schedule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Scientific Upgrades at the Oak Ridge National Laboratory High Flux Isotope Reactor

The United States Department of Energy is sponsoring a number of projects that will provide scientific upgrades to the neutron science facilities associated with the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory. Funding for the first upgrade project was initiated in 1996 and all presently identified upgrade projects are expected to be completed by the end of 2003. The upgrade projects include: (1) larger beam tubes, (2) a new monochromator drum for the HB-1 beam line, (3) a new HB-2 beam line system that includes one thermal guide and a new monochromator drum, (4) new instruments for the HB-2 beamline, (5) a new monochromator drum for the HB-3 beam line, (6) a supercritical hydrogen cold source system to be retrofitted into the HB-4 beam tube, (7) a 3.5 kW refrigeration system at 20 K to support the cold source and a new building to house it, (8) a new HB-4 beam line system composed of four cold neutron guides with various mirror coatings and associated shielding, (9) a number of new instruments for the cold beams including two new SANS instruments, and (10) construction of support buildings. This paper provides a short summary of these projects including their present status and schedule.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spectral calibration of the fluorescence telescopes of the Pierre Auger Observatory

We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. Here, we used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440 nm. Each point in a scan had approximately 2 nm FWHM out of the monochromator. Different sets of telescopes in the observatory have different optical components, and the eight telescopes measured represent two each of the four combinations of components represented in the observatory. We made an end-to-end measurement of the response from different combinations of optical components, and the monochromator setup allowed for more precise and complete measurements than our previous multi-wavelength calibrations. We find an overall uncertainty in the calibration of the spectral response of most of the telescopes of 1.5% for all wavelengths; the six oldest telescopes have larger overall uncertainties of about 2.2%. We also report changes in physics measureables due to the change in calibration, which are generally small.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical analysis of the background intensity distribution in X-ray Birefringence Imaging using synchrotron bending-magnet radiation

In the recently developed technique of X-ray Birefringence Imaging, molecular orientational order in anisotropic materials is studied by exploiting the birefringence of linearly polarized X-rays with energy close to an absorption edge of an element in the material. In the experimental setup, a vertically deflecting high-resolution double-crystal monochromator is used upstream from the sample to select the appropriate photon energy, and a horizontally deflecting X-ray polarization analyzer, consisting of a perfect single crystal with a Bragg reflection at Bragg angle of approximately 45°, is placed downstream from the sample to measure the resulting rotation of the X-ray polarization. However, if the experiment is performed on a synchrotron bending-magnet beamline, then the elliptical polarization of the X-rays out of the electron orbit plane affects the shape of the output beam. Also, because the monochromator introduces a correlation between vertical position and photon energy to the X-ray beam, the polarization analyzer does not select the entire beam, but instead selects a diagonal stripe, the slope of which depends on the Bragg angles of the monochromator and the polarization analyzer. In the present work, the final background intensity distribution is calculated analytically because the phase space sampling methods normally used in ray traces are too inefficient for this setup. X-ray Birefringence Imaging data measured at the Diamond Light Source beamline B16 agree well with the theory developed here.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗