Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METROLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Long-term stabilization of a heterodyne metrology interferometer down to a noise level of 20 pm over an hour

A heterodyne metrology interferometer was stabilized down to a noise level of 20 picometers (pm) as a root-mean-square (RMS) value integrated between 0.3 mHz and 1 Hz. This noise level was achieved by employing active and passive interferometer stabilization techniques. The heterodyne interferometer was built on a 50 mm square ultralow expansion glass plate in order to reduce an optical path length change caused by temperature variation. An optical configuration of the interferometer is a Mach-Zehnder interferometer with a design as symmetric as possible so that a detection signal can be insensitive to homogeneous thermal expansion of the glass plate. The heterodyne frequency is actively controlled in order to suppress residual noises caused by optical path length changes outside of the glass plate as well as phase fluctuations of the heterodyne frequency source. Our stabilization scheme is considered useful in achieving the 20 pm noise level without a stable heterodyne frequency source, as well as temperature stabilization around a whole apparatus. This interferometer can be used in precise metrology applications, such as characterization of deformation for satellite optical components against thermal exposure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical high-power nonlinearity comparison between the National Institute of Standards and Technology and the National Metrology Institute of Japan at 1480 nm

We compare the results of measurements of the nonlinearity of high-power optical fiber powermeters (OFPMs) by two national metrology institutes (NMIs): the National Institute of Standards and Technology (NIST-USA) and the National Metrology Institute of Japan/National Institute of Advanced Industrial Science and Technology (NMIJ/AIST-Japan) at a wavelength of 1480 nm. The nonlinearity and range discontinuity of a commercial OFPM were measured from 1 mW to 500 mW by use of a superposition method (both laboratories) and from 1 mW to 250 mW by use of a comparison method (NMIJ only). Measurement results showed largest differences of less than 1.6 parts in 10{sup 3}, which is within the combined expanded (k=2) uncertainty for both laboratories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cross-Cutting Metrology Tools for In Operando Characterization of Carrier Dynamics in Photovoltaic Devices (Final Technical Report)

Understanding the nature of recombination and its dependence on defects and interfaces is essential for engineering materials and contacts for higher V oc and photovoltaic (PV) efficiency. Time-resolved photoluminescence (TRPL) has conventionally been used to evaluate recombination, but not all materials are strongly emissive or otherwise suitable. Time-resolved terahertz spectroscopy is a pump – probe method that presents valuable complementary information, wherein an optical pump pulse photoexcites carriers within the absorber and the transient photoconductivity is probed with a terahertz pulse. Until now, experimental constraints have prohibited the use of terahertz probes to interrogate full device stacks, and measurements were instead made on exfoliated films or films grown on unconventional substrates. However, interfaces are critical to the behavior of photoexcited carriers in solar cells, and the substrates themselves often influence the film growth and bulk properties. Therefore, it is important to probe the behavior of PV absorbers as close as possible to their normal operating conditions. Here we have developed cross-cutting metrology that enable in operando characterization of carrier dynamics and recombination mechanisms in working PV devices. Through a combination of complementary non-contact TRTS and TRPL experiments and modeling, we have obtained key parameters including photoexcited carrier bulk lifetime and interface and back surface recombination velocities with greater precision and accuracy than can be achieved with conventional TRPL alone. By varying pulsed photoexcitation conditions, the contributions of interface and bulk recombination mechanisms can be determined. We have developed and refined this characterization approach by investigating CdTe PVs, which is a well-established technology but with significant margin for further improvements in efficiency. Results were published in Journal of Applied Physics (DOI: 10.1063/5.0064730) and Proceedings of the IEEE PVSC (DOI: 10.1109/PVSC43889.2021.9518559). After validating the approach, we have applied it to correlate recombination rates to processing conditions and material properties, including composition and defects as well as interfaces and surface treatments. Such feedback can inform processing and design choices to enable higher PV efficiency, not only for CdTe, but also CdSe x Te 1-x , CIGS, perovskites, kesterites, and future technologies. A perspective on predicting solar cell performance from terahertz spectroscopy was published in Advanced Energy Materials (DOI: 10.1002/aenm.202102776). The cross-cutting metrology tools developed here will enable determination of the locus and mechanism of performance-limiting recombination in thin film PV devices. This feedback can guide the engineering of PV devices with higher V oc and efficiency, thereby leading to reductions in levelized cost of electricity to meet the SunShot 2030 target of $0.03/kWh for utility-scale PV. Lower costs will enable rapid expansion of renewable electricity generation that is nearly free of carbon emissions. Reducing carbon emissions of the electricity sector is one of the most important solutions to climate change. The project’s specific focus on CdTe PV can benefit First Solar, the US company that is the global leader in CdTe technology, through both technology and workforce development.

14 SOLAR ENERGY↗

Dual-Image Color Normalization to Enable High-Performance Concentrating Solar Optical Metrology

Concentrating Solar Power (CSP) requires precision mirrors, and these in turn require metrology systems to measure their optical slope. In this project we studied a color-based approach to the correspondence problem, which is the association of points on an optical target with their corresponding points seen in a reflection. This is a core problem in deflectometry-based metrology, and a color solution would enable important new capabilities. We modeled color as a vector in the [R,G,B] space measured by a digital camera, and explored a dual-image approach to compensate for inevitable changes in illumination color. Through a series of experiments including color target design and dual-image setups both indoors and outdoors, we collected reference/measurement image pairs for a variety of configurations and light conditions. We then analyzed the resulting image pairs by selecting example [R,G,B] pixels in the reference image, and seeking matching [R,G,B] pixels in the measurement image. Modulating a tolerance threshold enabled us to assess both match reliability and match ambiguity, and for some configurations, orthorectification enabled us to assess match accuracy. Using direct-direct imaging, we demonstrated color correspondence achieving average match accuracy values of 0.004 h, where h is the height of the color pattern. We found that wide-area two-dimensional and linear one-dimensional color targets outperformed hybrid linear/lateral gradient targets in the cases studied. Introducing a mirror degraded performance under our current techniques, and we did not have time to evaluate whether matches could be reliably achieved despite varying light conditions. Nonetheless, our results thus far are promising.

14 SOLAR ENERGY↗

A Comprehensive Open-Source R Software For Statistical Metrology Calculations: From Uncertainty Evaluation To Risk Analysis

Whether calibrating equipment or inspecting products on the factory floor, metrology requires many complicated statistical calculations to achieve a full understanding and evaluation of measurement uncertainty and quality. In order to assist its workforce in performing these calculations in a consistent and rigorous way, the Primary Standards Lab at Sandia National Laboratories (SNL) has developed a free and open-source software package for computing various metrology calculations from uncertainty propagation to risk analysis. In addition to propagating uncertainty through a measurement model using the well-known Guide to Expression of Uncertainty in Measurement or Monte Carlo approaches, evaluating the individual Type A and Type B uncertainty components that go into the measurement model often requires other statistical methods such as analysis of variance or determining uncertainty in a fitted curve. Once the uncertainty in a measurement has been calculated, it is usually evaluated from a risk perspective to ensure the measurement is suitable for making a particular conformance decision. Finally, SNL’s software can perform all these calculations in a single application via an easy-to-use graphical interface, where the different functions are integrated so the results of one calculation can be used as inputs to another calculation.

97 MATHEMATICS AND COMPUTING↗

NASA Metrology and Calibration, 1980

The proceedings of the fourth annual NASA Metrology and Calibration Workshop are presented. This workshop covered (1) review and assessment of NASA metrology and calibration activities by NASA Headquarters, (2) results of audits by the Office of Inspector General, (3) review of a proposed NASA Equipment Management System, (4) current and planned field center activities, (5) National Bureau of Standards (NBS) calibration services for NASA, (6) review of NBS's Precision Measurement and Test Equipment Project activities, (7) NASA instrument loan pool operations at two centers, (8) mobile cart calibration systems at two centers, (9) calibration intervals and decals, (10) NASA Calibration Capabilities Catalog, and (11) development of plans and objectives for FY 1981. Several papers in this proceedings are slide presentations only.

Source record↗

Langley Research Center Metrology Program status for fiscal year 1987

The status of the Langley Research Center's metrology program for fiscal year 1987 is presented. The NASA Metrology Information System, which was operational for the entire year, provided the majority of performance data describing work analysis, turnaround time, out-of-tolerance instrument data, and other instrument service data. Calibration system development, equipment replacing and updating, status of last year's planned objectives, and Reference Standard certification requirements are described. The status of the LaRC voltage and resistance measurement assurance program and the agency-wide resistance program are reviewed. Progress on fiscal year 1987 objectives is discussed and fiscal year 1988 objectives are stated.

Kern, Frederick A.↗

Front-End Processor For Metrology-Information System

Front-end processor for NASA Metrology Information System (NMIS) is real-time relational data-base computer system designed to distribute processing for NMIS mainframe system or run as stand-alone local-area-network data-base system. System used in large calibration laboratories for work control and to maintain records of calibration, repair, costs, manpower usage, traceability, and other pertinent facts about instruments supported by laboratories. Provides enhancements to existing NASA Metrology Information System and batches upload to minimize mainframe I/O at times of heavy usage.

Muse, Walter S.↗

Endoscopic measurement using radial metrology with digital correlation

Radial metrology combines standard optical measurement techniques with a unique panoramic annular lens (PAL) system to study material properties and deformations on the inner surfaces of the cavities found, for example, inside pipes, tubes, and boreholes. A PAL profilometer using speckle metrology is analyzed and the equations obtained from the analysis are used to calibrate the PAL profilometer when it is used to profile the inner surface of a cylindrical pipe and to measure the deformation of the pipe when it is subjected to diametral compression.

Matthys, Donald R.↗

Metrology of X-ray optics utilizing shearing interferometric techniques

This paper will discuss the optical testing of extreme grazing incidence mirror systems and normal incidence high-precision mirror systems during fabrication processing of the optical substrates. The optical metrology is closely coupled with an advanced material removal process which will be discussed in terms of the optical metrology. Interferometric data will be presented of the optical surfaces. Surface roughness data will be shown and discussed.

Baker, Phillip C.↗

NASA's Metrology and Calibration program

The success of the National Aeronautics and Space Administration's scientific and engineering projects is often based on the capability and quality of the metrology and calibration programs of its field centers and facilities. A Metrology and Calibration Working Group, having representation from each of the NASA field centers and facilities, was established to develop and implement a program to provide a centralized direction and agency wide focus. A brief history of the Group is presented. The development of the Group's operating philosophy, the long term objectives, the measurement research and development program, and review of accomplishments is discussed.

Kern, Frederick A.↗

Development and implementation of the NASA Metrology and Information System

The NASA Metrology Information System (NMIS) was developed as a subsystem of the NASA Equipment Management System (NEMS) to provide a standardized technique in managing the calibration programs of its field Centers and facilities. The NMIS is a computerized data-base system providing: automatic instrument calibration recall and control, historical data including calibration and repair labor and parts costs, incoming instrument performance condition; instrument data including description, manufacturer, model and serial number, and instrument user name location. NMIS automatically provides 28 standardized calibration system performance reports on a user selected schedule. An ad hoc report generation capability is also provided. A standardized form, the Metrology Control Document, was developed for use as a calibration work order and data input document. System implementation plan is presented.

German, Earl S.↗

Laser Metrology System For A Segmented Telescope Reflector

Report describes proposed laser metrology system in far-infrared telescope with segmented primary reflector. Telescope to be flown in outer space and used to observe celestial objects. Laser metrology system mounted on structure that supported secondary telescope reflector and measures relative positions and alignments of segments of primary reflector. System used in pointing as well as in maintaining surface figure.

Lau, Kenneth H.↗

NASA metrology and calibration, 1993

Th sixteenth annual workshop of NASA's Metrology and Calibration Working Group was held April 20-22, 1993. The goals of the Working Group are to provide Agencywide standardization of individual metrology programs, where appropriate; to promote cooperation and exchange of information within NASA, with other Government agencies, and with industry; to serve as the primary Agency interface with the National Institute of Standards and Technology; and to encourage formal quality control techniques such as Measurement Assurance Programs. These proceedings contain unedited reports and presentations from the workshop and are provided for information only.

Source record↗

Metrology: Calibration and measurement processes guidelines

The guide is intended as a resource to aid engineers and systems contracts in the design, implementation, and operation of metrology, calibration, and measurement systems, and to assist NASA personnel in the uniform evaluation of such systems supplied or operated by contractors. Methodologies and techniques acceptable in fulfilling metrology quality requirements for NASA programs are outlined. The measurement process is covered from a high level through more detailed discussions of key elements within the process, Emphasis is given to the flowdown of project requirements to measurement system requirements, then through the activities that will provide measurements with defined quality. In addition, innovations and techniques for error analysis, development of statistical measurement process control, optimization of calibration recall systems, and evaluation of measurement uncertainty are presented.

Castrup, Howard T.↗

A dual purpose optical truss laser metrology system for a space-based far-IR segmented telescope: Figure maintenance and pointing control

To obtain imaging performance as for monolithic mirrors, large segmented reflectors used for astronomy must be actively aligned and pointed to extreme levels of precision. A system concept for a dual purpose optical truss laser metrology system is described which is used for both figure and alignment maintenance and telescope pointing. A two-stage figure active control approach was developed for several proposed spaceborne far infrared segmented telescopes, one of which is the 10-20 meters Large Deployable Reflector (LDR). The first active control stage, the figure initialization control system, aligns the optical elements (i.e., the primary segments, secondary and focal plane assembly) based on images obtained. The second stage, the figure maintenance control system, maintains the alignment between re-initializations using measurements provided by laser interferometers arranged in an optical truss configuration. It measures the relative positions and alignments of the telescope segments so that a controller can reposition them appropriately. The application of this optical truss for figure maintenance control is the subject of the first part of this paper. The second portion of this paper discusses the application of the optical truss to telescope pointing. Here, the laser metrology system is used to transfer pointing information from an external fine guidance sensor (FGS) to the telescope optical boresight as defined by the primary mirror, secondary mirror, and focal plane assembly. Thus, any alignment variations between the two boresights can be observed and accounted for.

Lau, Kenneth↗

Superpolishing and Precision Metrology on a Metal Mandrel and Replicated Segments for Constellation-X

We have superpolished a diamond-turned aluminum mandrel (coated with electroless Ni) to an axial roughness of 6.34 nm rms. The mandrel is made to the Astro-E secondary mirror design for the 81st shell. Precision metrology at 100 mm to submicron scales has established the power spectral density of the mandrel and ultralightweight gold coated replicated segments. Predicted image quality of a set of optimally aligned replicated segments of this and a matching primary is substantially improved as compared to the flight mirrors for Astro-E. This approach using metal mandrels, superpolishing, and replicated ultralightweight foil mirrors, may represent a cost-effective approach to meeting the 15 arcsec half-energy width and weight requirements for the Constellation-X mission. Descriptions of the polishing apparatus, the precision metrology instruments, and the surface data analysis are presented. The general methods described are applicable to precision optics for both normal incidence and grazing incidence optics.

Content, D.↗

Superpolishing and Precision Metrology on a Metal Mandrel and Replicated Segments for Constellation-X

We have superpolished a diamond-turned aluminum mandrel (coated with electroless Ni) to an axial roughness of 0.34 nm rms. The mandrel is made to the Astro-E secondary mirror design for the 81st shell. Precision metrology at 100 mm to submicron scales has established the power spectral density of the mandrel and ultralightweight gold coated replicated segments. Predicted image quality of a set of optimally aligned replicated segments of this and a matching primary is substantially improved as compared to the flight mirrors for Astro-E. This approach using metal mandrels, superpolishing, and replicated ultralightweight foil mirrors, may represent a cost-effective approach to meeting the 15 arcsec half-energy width and weight requirements for the Constellation-X mission. Descriptions of the polishing apparatus, the precision metrology instruments, and the surface data analysis are presented. The general methods described are applicable to precision optics for both normal incidence and grazing incidence optics.

Content, D.↗