Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Use of carbonyldiimidazole as a derivatization agent for the detection of pinacolyl alcohol, a forensic marker for Soman, by EI-GC–MS and LC-HRMS in official OPCW proficiency test matrices

Pinacolyl alcohol (PA), a key forensic marker for the nerve agent Soman (GD), is a particularly difficult analyte to detect by various analytical methods. In this work, we have explored the reaction between PA and 1,1'-carbonyldiimidazole (CDI) to yield pinacolyl 1H-imidazole-1-carboxylate (PIC), a product that can be conveniently detected by gas chromatography–mass spectrometry (GC–MS) and liquid chromatography-high-resolution mass spectrometry (LC-HRMS). Regarding its GC–MS profile, this new carbamate derivative of PA possesses favorable chromatographic features such as a sharp peak and a longer retention time (RT = 16.62 min) relative to PA (broad peak and short retention time, RT = 4.1 min). Additionally, the derivative can also be detected by LC-HRMS, providing an avenue for the analysis of this chemical using this technique where PA is virtually undetectable unless present in large concentrations. From a forensic science standpoint, detection of this low molecular weight alcohol signals the past or latent presence of the nerve agent Soman (GD) in a given matrix (i.e., environmental or biological). The efficiency of the protocol was tested separately in the analysis and detection of PA by EI-GC–MS and LC-HRMS when present at a 10 μg/mL in a soil matrix featured in the 44th PT and in a glycerol-rich liquid matrix featured in the 48th Official Organization for the Prohibition of Chemical Weapons (OPCW) Proficiency Test when present at a 5 μg/mL concentration. In both scenarios, PA was successfully transformed into PIC, establishing the protocol as an additional tool for the analysis of this unnatural and unique nerve agent marker by GC–MS and LC-HRMS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser Time-of-Flight Mass Spectrometry for Space

A miniature reflection time-of-flight mass spectrometer for in situ planetary surface analysis is described. The laser ablation mass spectrometer (LAMS) measures the regolith's elemental and isotopic composition without high-voltage source extraction or sample preparation. The compact size (< 2 x 10(exp 3) cubic cm) and low mass (approximately 2 kg) of LAMS, due to its fully coaxial design and two-stage reflectron, fall within the strict resource limitations of landed science missions to solar system bodies. A short-pulse laser focused to a spot with a diameter approximately 30-50 micrometers is used to obtain microscopic surface samples. Assisted by a microimager, LAMS can interactively select and analyze a range of compositional regions (with lateral motion) and with repeated pulses can access unweathered, subsurface materials. The mass resolution is calibrated to distinguish isotopic peaks at unit masses, and detection limits are on resolved to a few ppm. The design and calibration method of a prototype LAMS device is described, which include the development of preliminary relative sensitivity coefficients for major element bulk abundance measurements.

Brinckerhoff, W. B.↗

Organic Matter Composition in June 2023 and September 2023 Across the McKenzie Sub-Basin Impacted by the 2020 Holiday Farm Fire

This dataset represents results from a field study aiming to understand the variability in post-fire responses of dissolved organic matter and determine drivers of post-fire responses. Samples were collected at 58 sites within the McKenzie River Watershed (Oregon, USA) that were upstream, within, and downstream of the Holiday Farm Fire burn perimeter. The samples were collected in June 2023 and September 2023 during storm events, approximately 3 years post-fire. Samples were characterized for benezenepolycarboxylic acids (BPCA) and ultra-high resolution mass spectrometry. Dissolved organic carbon and optics (absorbance and fluorescence) data can be found in a separate data packages (https://ir.library.oregonstate.edu/concern/datasets/zc77sz60m, https://ir.library.oregonstate.edu/concern/datasets/mc87q034m). Related data from a subset of sites from 2020-2022 can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1869708 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2478546. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset contains (1) file-level metadata; (2) data dictionary; (3) data package readme; (4) metadata; (5) methods information; (6) benzene polycarboxylic acid (BPCA) concentration data; (7) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) methods; (8) folder of high resolution characterization of organic matter via 12 Tesla FTICR-MS data generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). This package contains the following file types: csv, xml, pdf.

54 ENVIRONMENTAL SCIENCES↗

Chemical characterization of microplastic particles formed in airborne waste discharged from sewer pipe repairs

Microplastic particles are of increasing environmental concern due to the widespread uncontrolled degradation of various commercial products made of plastic and their associated waste disposal. Recently, common technology used to repair sewer pipes was reported as one of the emission sources of airborne microplastics in urban areas. This research presents results of the multi-modal comprehensive chemical characterization of the microplastic particles related to waste discharged in the pipe repair process and compares particle composition with the components of uncured resin and cured plastic composite used in the process. Analysis of these materials employs complementary use of surface-enhanced Raman spectroscopy, scanning transmission X-ray spectro-microscopy, single particle mass spectrometry, and direct analysis in real-time high-resolution mass spectrometry. Further, it is shown that the composition of the relatively large (100 μm) microplastic particles resembles components of plastic material used in the process. In contrast, the composition of the smaller (micrometer and sub-micrometer) particles is significantly different, suggesting their formation from unintended polymerization of water-soluble components occurring in drying droplets of the air-discharged waste. In addition, resin material type influences the composition of released microplastic particles. Results are further discussed to guide the detection and advanced characterization of airborne microplastics in future field and laboratory studies pertaining to sewer pipe repair technology.

54 ENVIRONMENTAL SCIENCES↗

High-isospin multiplets in 𝐴=15 and 16 nuclei

Isospin quartets (T=3/2) and quintets (T=2) have been investigated for A=15 and A=16 nuclei, respectively. Data from an invariant-mass experiment, with a 17 Ne beam, were reanalyzed and the T=3/2 and T=2 states in 15 O and 16 F, associated with p+ 14 N and 2p+ 14 N exit channels respectively, were found. In some cases, γ-ray gating was used to tag on events that decay to the excited 0 + , T=1 state in 14 N rather than the ground state. With the new states, the lowest-energy 1/2 + and 5/2 + quartets for A=15 and the 0 + and 2 + quintets for A=16 are completed. In addition, members of these multiplets in 15 F and 16 Ne decaying to the p+ 14 O and 2p+ 14 O channels are reevaluated by gating on events where the 14 O fragment recoils perpendicular to beam axis in the parent reference frame. Such transverse-decay events have the best invariant-mass resolution. No evidence for deviations from a quadratic dependence of the mass on the isospin projection was found for the A=15 quartets. However for the A=16 0 + and 2 + quintets, evidence for deviations were found.

Coulomb energies↗

A satellite-borne ion mass spectrometer for the energy range 0 to 16 keV

The Ion Composition Experiment (ICE) on GEOS represents the first comprehensive attempt to measure the positive ion composition at high altitudes in the magnetosphere. Due to the heterogeneous nature of the magnetospheric plasma a novel mass spectrometer has been developed to cover the mass per charge range from H-1(+) to beyond Ba-138(+) and the energy per charge range from 0 to 16 keV/e. The ICE consists primarily of a cylindrical electrostatic analyzer followed by a curved analyzer incorporating crossed magnetic and electric fields. This combination has limited angular and energy focusing properties, but it maintains a mass resolution of about 4 over a wide range in energy and mass, sufficient for the objectives of measuring plasmas of both solar and terrestrial origin. High sensitivity and low background should allow measurements of rarer ion constituents down to flux levels of 0.01 ions/sq cm sec ster eV. A sophisticated electronics combined with powerful ground computer and telecommand systems allow for very efficient scanning of the mass-energy space.

Balsiger, H.↗

High precision electric gate for time-of-flight ion mass spectrometers

A time-of-flight mass spectrometer having a chamber with electrodes to generate an electric field in the chamber and electric gating for allowing ions with a predetermined mass and velocity into the electric field. The design uses a row of very thin parallel aligned wires that are pulsed in sequence so the ion can pass through the gap of two parallel plates, which are biased to prevent passage of the ion. This design by itself can provide a high mass resolution capability and a very precise start pulse for an ion mass spectrometer. Furthermore, the ion will only pass through the chamber if it is within a wire diameter of the first wire when it is pulsed and has the right speed so it is near all other wires when they are pulsed.

Sittler, Edward C.↗

High-resolution mapping of mass loss from highly evolved carbon stars

The molecular component of the mass outflow at high resolution was mapped with the Owens Valley Millimeter-Wave Interferometer in two well-known objects, CRL 2688 and CIT 6. Interferometric observations of a pair of carbon stars which are evolving toward the planetary nebula stage have revealed evidence of episodic, nonspherically symmetric mass loss, and may lead to a fuller understanding of shielding properties of the dust grains involved in these flows.

Ball, R.↗

Pioneer Venus Sounder Probe Neutral Gas Mass Spectrometer

A neutral gas mass spectrometer was flown to Venus as part of the Pioneer Venus Multiprobe to measure the composition of its lower atmosphere. The instrument, mounted in the Sounder Probe, was activated after the probe entered the top of the atmosphere, and it obtained data during the descent from 62 km to the surface. Atmospheric gases were sampled through a pair of microleaks, the effluent from which was pumped by a combination of ion and getter pumping. A pneumatically operated valve, controlled by the ambient atmospheric pressure, maintained the ion source pressure at a nearly constant value during descent while the atmospheric pressure varied by three orders of magnitude. A single focusing magnetic sector field mass spectrometer with mass resolution sufficient to reasonably separate argon from C3H4 at 40 amu provided the mass analysis and relative abundance measurements. A microprocessor controlled the operation of the mass spectrometer through a highly efficient peak-tip stepping routine and data compression algorithm that effected a scan of the mass spectrum from 1 to 208 amu in 64 sec while requiring an information rate of only 40 bits/sec to return the data to earth. A subscale height altitude resolution was thus obtained. Weight, size, and power requirements were minimized to be consistent with interplanetary flight contraints.

Hoffman, J. H.↗

Organic Matter Concentration and Composition in November 2021 and April 2022 from 12 Streams Impacted by the 2020 Holiday Farm Fire (v2)

This dataset represents results from a field study aiming to understand storm induced transport of pyrogenic materials to streams impacted by varying degrees of burn severity. Time series samples were collected at 5 sites within the McKenzie River Watershed (Oregon, USA) whose catchment were each completely engulfed by the 2020 Holiday Farm Fire. An additional 7 sites were sampled once during the storm. The samples were collected during storm events in November 2020, January 2021, November 2021, and April 2022. Samples were characterized for benezenepolycarboxylic acids (BPCA), ultra-high resolution mass spectrometry, dissolved organic carbon and optics (absorbance and fluorescence). Fourier-transform ion cyclotron resonance mass spectrometry (FTICR) and dissolved organic carbon data from the November 2020 (referred to as “EWEB_2020”) sampling can be found in a separate data package (doi: 10.15485/1869708). NOTE: The 2020 samples were run on FTICR-MS in two unique instances. The first run can be found in the previous data package (EWEB_2020). The second run is included in this data package. These samples were run for a second time so that the data were more directly interoperable with the other samples in this data package. We have not done any investigation into the differences/similarities between these datasets and the previously ran/published data in the other data package. This data package was originally published in November 2024. It was updated in April 2025 (v2; new and modified files). See the change history section below for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset contains (1) file-level metadata; (2) data dictionary; (3) data package readme; (4) metadata; (5) methods information; (6) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data; (7) excitation emission matrix (EEM) methods; and (8) a sub-folder with processed EEM data (9) benzene polycarboxylic acid (BPCA) concentration data; (10) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) methods; and (11) folder of high-resolution characterization of organic matter via 12 Tesla FTICR-MS generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). The EEMs sub-folder contains two additional folders; the Absorbance and Fluorescence folders which contain the processed EEMs absorbance and fluorescence data respectively. This package contains the following file types: csv, xml, pdf.

54 ENVIRONMENTAL SCIENCES↗

Analytical techniques for identification and study of organic matter in returned lunar samples

The results of geochemical research are reviewed. Emphasis is placed on the contribution of mass spectrometric data to the solution of specific structural problems. Information on the mass spectrometric behavior of compounds of geochemical interest is reviewed and currently available techniques of particular importance to geochemistry, such as gas chromatograph-mass spectrometer coupling, modern sample introduction methods, and computer application in high resolution mass spectrometry, receive particular attention.

Burlingame, A. L.↗

The heavy ion analyser PICCA for the comet Halley fly-by with Giotto

The heavy ion analyzer RPA2-PICCA is designed to identify the composition and distribution of thermal positive ions in the coma of the comet Halley. The instrument is an electrostatic analyzer which takes advantage of the large relative flyby velocity and the fact that the ions in the inner coma should have low temperatures and be predominantly singly charged. Thus, the energy/charged measurements can be directly related to the mass distribution of the ions. Mass identification will be provided in the range from 10 to 203 amu (atomic mass units) with a mass resolution of either 0.4 amu or 1 amu, dependent on the ion mass.

Korth, A.↗

Isotopes of cosmic ray elements from neon to nickel

Results obtained from a balloon exposure of a cosmic ray detector flown in 1977 are reported. The charge resolution ranged from 0.19 to 0.21 charge units between neon and nickel and the mass resolution for nuclei stopped in the emulsions ranged from 0.40 to 0.70 amu for A between 20 and 60 amu. This was enough to correctly identify almost all nuclei, but not to uniquely resolve neighboring mass peaks. Both Ne and Mg show evidence for neutron enrichment relative to the solar system abundance. Si and S are consistent with solar abundances, while Ar has no significant source abundances. P, Cl and K have essentially no primary component and the isotopic distribution observed is quite consistent with that expected from propagation. An excess of Ca-44 at the source is shown, indicating high metallicity in the source. The abundance of Fe-58 is nine percent or less, and Ni shows a one-to-one ratio for Ni-58 to 60, implying intermediate metallicity.

Waddington, C. J.↗

Spin-trap isomers in deformed, odd-odd nuclei in the light rare-earth region near $N=98$

Masses of neutron-rich, odd-odd Pm, Eu, and Tb nuclei near N = 98 were measured using the Canadian Penning Trap mass spectrometer at the Californium Rare Isotope Breeder Upgrade (CARIBU) facility. High-resolution mass measurements yielded the discovery of spin-trap isomers at N = 97 in Tb 162 , and in the N = 99 isotones of Pm 160 and Tb 164 . Furthermore, no evidence of long-lived isomers were observed at N = 95 in Eu 158 , at N = 97 in Pm 158 , nor at N = 101 in Eu 164 and Tb 166 . Here, these experimental observations are compared to results from multiquasiparticle blocking calculations.

150 ≤ A ≤ 189↗

Large mass single electron resolution detector for dark matter and neutrino elastic interaction searches

Large mass single electron resolution solid state detectors are desirable to search for low mass dark matter candidates and to measure coherent elastic neutrino nucleus scattering (CEvNS). In this paper we present results from a novel 100 g phonon-mediated Si detector with a new interface architecture. This detector gives a baseline resolution of ~ 1e - /h + pair and a leakage current on the order of 10 -16 A. This was achieved by removing the direct electrical contact between the Si crystal and the metallic electrode, and by increasing the phonon absorption efficiency of the sensors. The phonon signal amplification in the detector shows a linear increase while the signal to noise ratio improves with bias voltage, up to 240 V. This feature enables the detector to operate at a low energy threshold which is beneficial for dark matter and CEvNS like searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting low-mass perturbers in cluster lenses using curved arc bases

ABSTRACT Strong gravitationally lensed arcs produced by galaxy clusters have been observationally detected for several decades now. These strong lensing constraints provided high-fidelity mass models for cluster lenses that include substructure down to $10^{9{-}10}\, \mathrm{M}_\odot$. Optimizing lens models, where the cluster mass distribution is modelled by a smooth component and subhaloes associated with the locations of individual cluster galaxies, has enabled deriving the subhalo mass function, providing important constraints on the nature and granularity of dark matter. In this work, we explore and present a novel method to detect and measure individual perturbers (subhaloes, line-of-sight haloes, and wandering supermassive black holes) by exploiting their proximity to highly distorted lensed arcs in galaxy clusters, and by modelling the local lensing distortions with curved arc bases. This method offers the possibility of detecting individual low-mass perturber subhaloes in clusters and haloes along the line of sight down to a mass resolution of $10^8\, \mathrm{M}_\odot$. We quantify our sensitivity to low-mass perturbers ($M\sim 10^{7{-}9}\, \mathrm{M}_\odot$) in clusters (M ∼ 1014–15 M⊙), by creating realistic mock data. Using three lensed images of a background galaxy in the cluster SMACS J0723, taken by JWST, we study the retrieval of the properties of potential perturbers with masses $M=10^{7{-}9}\, \mathrm{M}_\odot$. From the derived posterior probability distributions for the perturber, we constrain its concentration, redshift, and ellipticity. By allowing us to probe lower mass substructures, the use of curved arc bases can lead to powerful constraints on the nature of dark matter as discrimination between dark matter models appears on smaller scales.

Astronomy & Astrophysics↗